Home / Financial Firm (Unknown - Insurer) / Determination 296936

Determination 296936

Building damage claim denied under subsidence, earth movement and settling exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2013-04-26
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's home garage and bedroom were damaged and the FSP denied the claim as subsidence and settling after a 2005 burst pipe. AFCA found the FSP had not proved the exclusion and ordered reimbursement of actual repair costs on receipts.

The FSP bore the burden of proving the exclusion, and the soil testing evidence favoured damage from the insured leaking pipe event over drying or settlement.

Issues

Subjects and remedies

home or building damagepay claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 296936 Determination Page 1 of 11 Case number: 296936 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim - Policy Exclusion - Subsidence, Earth Movement, Normal Settling 09 April 2013 Background 1. The Applicant holds a home building insurance policy with the Financial Services Provider (FSP). 2. On 16 April 2009, the Applicant lodged a claim with the FSP for damage to the building allegedly due to water inundation on 26 November 2005 caused by a burst irrigation water pipe that runs along the front of the house. 3. The FSP’s assessor inspected the property and noted ―significant subsidence of the northern end of the double garage which forms part of the main roof structure [of the home]‖ and ―consequenti al cosmetic damage to walls, a window and ceiling of the double garage‖. 4. The FSP obtained expert opinion from M Engineers. In a report dated 31 July 2009, M Engineers concluded that ―it is more likely that this more recent onset of foundation soil settlement has been caused by seasonal and environmental moisture demand on the clay foundation‖. 5. On 4 September 2009, the FSP denied the claim. 6. In the beginning of 2011, the Applicant decided to proceed with repairing the damage at his own cost in conjunction with extensions planned for the opposite end of the house. The house was inundated in February 2011 due to heavy rain and his plan to repair was interrupted. According to the Applicant, he then organised ―a thorough investigation‖ of the cause of damage ―to ensure any future construction would not likely to move‖ again. 7. Geotechnical Engineer H of XYZ Testing Services inspected the property. His report dated April 2012 concluded that the ―reduction in bearing strength in this location‖ ―was possibly caused through the flooding of the site in 2005‖. 8. As Engineer H’s opinion differed from M Engineers’ opinion, the Applicant sought a review of the FSP’s denial of his claim in 2009. 9. The FSP organised another inspection of the property by F Engineers. F Enginee rs’ report dated 4 June 2012 concluded that ―the previous burst of Determination Case No: 296936 Determination Page 2 of 11 the irrigation water pipe has not caused, or contributed to, the observed distress in the subject residence‖. The foundation movement was result of several factors, namely, (a) deep soil drying due to tree root desiccation of clay foundations; (b) seasonal changes in soil moisture contents, amplified by nearby trees; (c) highly reactive clay soils; (d) poor site drainage; and (e) inadequate footing size. 10. In its Internal Dispute Resolution letter dated 2 August 2012, the FSP maintained the denial of the claim. Summary of Applicant’s position 11. The Applicant relies on the report by Engineer H of XYZ Testing Services which is discussed below. 12. He says that Engineer H’s investigation included excavating five large holes at various locations, examining the footings, examining the foundations and looking for root intrusions. On the other hand, the FSP’s engineers only took a look, did not take any samples and did not dig any holes. 13. He seeks the FSP’s ―fair contribution‖ to the reconstruction of the damaged garage/bedroom area of the house. Summary of FSP’s position 14. The FSP says it is entitled to deny the claim based on the reports by F Engineers and M Engineers which are discussed below. 15. It says that the alleged flooding occurred in 2005, yet the claim was only made by the Applicant after three and a half years. The FSP has suffered prejudice by the Applicant’s delay in submitting the claim within the period required by the policy. 16. The FSP relies on the following policy provisions contained on pages 20 and 34 of the Product Disclosure Statement (PDS): ― The following exclusions apply to every section of Part A – Home Cover Part A – Home Cover does not cover: ... 3. Loss or damage to your property caused by: .. b. erosion, landslide, subsidence or earth movement (other than earthquake): c. normal settling, shrinkage or expansion in buildings or foundations, walls and pavements; ... Case No: 296936 Determination Page 3 of 11 What you must do after loss, damage or accident ... Advise us of the claim as soon as possible and then supply us with full written details by completing our claim form. You or someone acting on your behalf must complete a claim form within 30 days of an occurrence, if you do not, we may reduce the amount we pay if the delay causes increased costs or prevents us investigating the claim.‖ Issue 17. Whether the FSP is entitled to deny the claim. Reasons for decision 18. Due to the nature of the dispute, the FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. Thus, this dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination. The parties have been previously advised that a Determination will be issued in this case. Delay in lodging claim 19. The policy states that the insured ―must complete a claim form within 30 days of an occurrence‖. 20. The Applicant lodged a claim after more than three years from the leaking pipe event. He gave the following explanation: ―After this [November 2005] flooding had occurred I was aware of the fact that an internal wall of our garage had moved but I had not realized that the corner of the garage slab had subsided and caused this. Our house is a tilt slab type construction and as such has solid concrete walls that are tied together at the top of each panel and as the slab subsided in this corner it had pulled the wall over. It was only after discussing this with a family friend in 2008 who is a building inspector that the connection was made between the flooding of the garage corner area [in 2005] and the slab movement that I hadn’t realized had occurred that had in turn caused the internal wall to move or break away. My building inspector friend recommended I claim it on my insurance as taking legal action against the water authority could be very expensive‖. 21. I accept the Applicant’s explanation. In my opin ion, the policy condition of completing a claim form within 30 days of an occurrence should not be applied unreasonably. If for example, the insured witnesses his ceiling leak during a heavy rain, the insured is expected to report the damage or loss within 30 days from the rain event. However, if subsidence or movement in the building occurs, the policy condition should not be strictly applied Case No: 296936 Determination Page 4 of 11 because subsidence/movement is not something that an ordinary person easily or immediately notices. Cause of damage 22. The parties have submitted expert reports in support of their respective positions. I note the following. M Engineers’ 2009 reports 23. M Engineers inspected the property on 29 May 2009 and issued two reports. 24. M Engineers’ first report dated 20 July 200 9 concludes as follows: ― SUMMARY OF OPINION In the writer’s opinion, based on the available information, it is possible that inundation of the site in late 2005 due to a burst water main could have contributed to an increased degree of footing movement at the home's eastern end. Consequently, the onset of damage over the years after the leak may bear a relationship to the leaking pipe. Before any final decision is made on policy coverage and/or repair approach, we recommend further investigation into the actual foundation soil conditions at the site. Soil samples could be recovered, or Council records could be searched.‖ 25. A second report dated 31 July 2009 was issued by M Engineers. This relevantly reads: ―After preparing ou r earlier report, our office contacted [Applicant], initially to obtain his consent to searching the ... Council's archives for information regarding soil testing at the site. [The Applicant] was able to find the footing report prepared for the insured dwelling's construction, which was prepared in January 1990 by [X], and forwarded his copy of the report to our office. With reference to the attached copy of the soil borelog contained within that report, it can be seen that the foundation soil profile at the sample location comprised approximately 250mm depth of clayey silt/silty clay, over silty clay extending to a depth of at least 3 metres below the site surface. The soil profile was classified as "Class H" in accordance with Australian Standard AS2870.1 — 1998. In other words, the foundation soil profile at the site comprises almost entirely silty clay of medium to high reactivity and bearing strength. The soil profile identified in the borelog does not indicate the presence of any collapsible silty soils at all, let alone in the area where the home's footings would be bearing. In light of this information, and given that the home's footing beams are bearing within the silty clay soil, it is the writer's opinion that any inundation of the site by the leaking water supply pipe would have caused a heaving movement beneath the building footings, rather than a settlement movement or subsidence. This heaving movement would have occurred relatively shortly after the site was inundated — that is, within a week or two of the inundation. The fact that the house reportedly did not appear to suffer any movement until some years after the water supply pipe leak indicates that the leak did not Case No: 296936 Determination Page 5 of 11 have a significant influence on the moisture content of reactive clay foundation soil beneath the home. In other words, because the site inundation did not cause a heaving movement at around the time the inundation occurred, the current settlement movement (which is related to the clay soil becoming drier) cannot be the result of the inundation causing the clay to initially become wet. In the writer's opinion, based on this foundation soil information, it appears more likely that the gradual onset of foundation settlement beneath the home's garage end has occurred because the ongoing drying influence of seasonal evaporation from the foundation and the moisture demand of trees and shrubs growing around the home's garage end has caused the foundation soil to dry out and shrink, leading to settlement of the home's footings. The difference in performance between the garage end of the house and the western end may be explained by differences in the soil profile's reactivity across the house area, or by the more recent influence of trees and shrubs growing around the home's western end as compared to the earlier influence of the more mature trees growing around the home's western end. ‖ Engineer H/XYZ Testing Services ’ report 26. Engineer H of XYZ Testing Services issued a report dated April 2012 that relevantly reads: 3 FIELDWORK The geotechnical investigation was conducted on the 21 st March, 2012 and involved the excavation of 4 test pits to expose the footings to depths of between 1.0 and 1.2 metres. Dynamic Cone Penetrometer (DCP) tests were conducted with the results reported on the engineering logs. Disturbed samples of the material were also obtained for subsequent laboratory testing. Test pits 1 and 2 are located in the region of the most settlement (rear garage comer) with TP3 at the southwestern end and TP4 at the front of the garage. The footing exposures indicated that the edge beams of the raft slab are founded in either Silty Clayey Sand fill material or Silty Sandy Clay at depths of 400 and 440mm below the surface with approximately 100mm the recess for the tilt panels for a total depth of 500 to 540mm from lop of slab to base of footing. The field investigation was conducted by a technician, who logged the subsurface profile and conducted the testing program. The borehole logs are included in the Appendix with their location shown on the attached drawing. 4 RESULTS ... 5 DISCUSSION It should be noted that the founding conditions (moisture content, strength etc) at the time of construction are not known to [XYZ Testing Services]. This can make it difficult to be definitive in the cause of failure as these can be caused by changes in conditions. The failure and movement in the building appears to be due to the settlement/consolidation of the rear corner of the garage which has in turn Case No: 296936 Determination Page 6 of 11 applied rotational movement and stresses on the building. This has resulted in cracks opening up between the panels and around window/door frames along with the alignment of the roof tiles changing. Cracking in buildings can generally be attributed to either one or a combination of 3 factors. They are moisture change in the soil creating shrinkage or heaving, insufficient footings for the structure and soil conditions, or insufficient strength in the soil (bearing/shear failure). A site classification was conducted by ... in 1989 which classified the site as Class H in accordance with AS2870.1 — 1988. Based on this classification and the standard at the time, the depth of edge beams for an articulated full masonry structure were recommended to be 800mm whilst for an articulated masonry veneer structure the beam depth should be 500mm. The client forwarded a copy of the footing designs which shows the beam depth below the tilt panel to be 525mm with a total depth (from top of slab to base of footing) of 625mm (100mm recess for the panels). As mentioned in Section 3 the total depth of footing was between 500 and 540mm. It has been suggested that the cause of cracking is due to the drought or a drying of the subsurface profile. It is [XYZ Testing Services’] opinion, that if the drought/drying of the subsurface profile was the main cause of cracking, it would be evident throughout the entire building, and not just in one corner of the garage. This is further backed up by the large gum trees at the southwestem end close to the building. There are several tree roots under the footings, and the material was noticeably drier in this area (TP3). As such, it would be expected that the soil in this area would shrink and potentially cause damage to the building. This is not the case indicating that the footings have withstood any seasonal/drying movement. The laboratory tests indicate that the material at the site is of medium to high plasticity. The material in TPs 3 and 4 is lower than TPs 1 & 2. Based on the laboratory tests and soil profile it has been estimated that the site has a seasonal surface movement value ys of 60mm. Taking into account the presence of the tree approximately 5 metres away from the garage, this increases the potential surface movement to 85mm. For this amount of settlement to occur the clay material would need to be very dry. Then if it wet up again, it would swell, causing some the slab to lift again. The material at the site is considered moist with the moisture content being just under the plastic limit. This further indicates that drying of the soil has not caused the cracking of the structure. In regards to the footings, the field investigation indicated that they had a total depth of between 500 and 540mm. This is slightly less than the design of 625mm. However, the general performance of the footings over the main building footprint indicate that they are performing satisfactorily. The only concern is the rear corner of the garage. The DCP tests indicated that at the time of the investigation the founding material had an allowable bearing pressure in excess of 100kPa. Differential movement in the structure may also be caused by insufficient initial strength in the Clayey Sand fill which may have consolidated/settled over time. Conversely, if the Clayey Sand material is dry at the time of construction but with suitable strength (as noted the conditions at time of construction were unknown by [XYZ Testing Services]) an increase in moisture content may cause a reduction in strength and subsequent consolidation/settlement. Additionally, if there was a soft spot immediately beneath the footings in the Case No: 296936 Determination Page 7 of 11 corner of the garage at the time of construction, it is expected that consolidation//settlement and subsequent cracking would occur within a relatively short time of loading/construction which is not the case. 6 CONCLUSION As mentioned previously it is difficult to be definitive to the cause of failure as the initial conditions are not known to [XYZ Testing Services]. However, based on the results of this investigation and the mode of failure with it being restricted to the rear corner of the garage, the most likely cause is a reduction in bearing strength in this location. This was possibly caused through the flooding of the site in 2005 with the water softening the immediate founding material, particularly the Clayey Sand fill which caused settlement of the rear corner of the garage.‖ F Engineers’ report 27. In response to the above, the FSP organised another inspection by F Engineers who then issued a report dated 4 June 2012. The report relevantly states: ―5.0 Discussion Distress has occurred throughout the residence, however, there is significantly more internal and external distress towards the NE region of the house. This observation is consistent with the floor levels survey, which indicates movement has generally occurred in the NE and SW regions of the house, however, the greatest movement has occurred towards the NE corner. The damage with respect to internal plasterboard lined walls generally falls within the damage Categories 2 and 3 in accordance with Table Cl of AS2870-1996. The damage with respect to the external precast panel walls is limited to Categories 1 and 2 in accordance with Table C l of AS2870-1996. The distress to this house does not appear to be recent, and in [F Engineers’] opinion, movement and distress to this house has been occurring for many years. [F Engineers] has reviewed the Geological Survey Maps for the subject region (1:100,000 series), which indicates the site is located in the province of Quaternary aged 'Wooden Formation" sedimentary deposits. The soils at this site are expected to be highly reactive i.e. Class H type soils in accordance with AS2870 without considering the effect of the trees existing in the subject property. The results of geotechnical investigations carried out by ... in 1989 and [XYZ Testing Services] in 2012 confirmed this soil reactivity. However, due to abnormal moisture conditions expected to have been caused by the presence of trees in close proximity, the subject site is expected to be classified as "P" soils (Problematic) in accordance with AS2870-1996. Highly reactive clay soils have significant volumetric changes with relative changes in moisture content, i.e. if moisture content increases, the clay soils will swell, and if moisture content decreases, then the clay soils will shrink. According to AS2870, seasonal changes in moisture content of the foundation material can cause up to 60mm movement at the surface (ys) in this type of soils over the design life of the building. Furthermore, the presence of large Case No: 296936 Determination Page 8 of 11 trees in the close proximity of the foundation in the subject building can exacerbate the seasonal changes in moisture content and cause up to 84mm movement at the surface of the soil ("modified" ys) over the design life of the building taking into the consideration of the distance and height of trees and soil class factor (Note, this theoretical estimation of expected movements at the subject site is also discussed and confirmed in the [XYZ Testing Services] report). The greatest actual movement measured at this site (relative fall of approx. 100 mm) coincides with these theoretical movement estimates within approximately 15% margin. The locations and pattern of the wall and ceiling cracks observed in the subject residence is typical of distress caused by differential foundation movements in this type of soils. In this case, the distress pattern and the floor level survey indicates that there have mostly likely been relative settlements of the NE and SW regions of the house. In F Engineers’ op inion, the observed distortion of the raft slab footing has been most likely caused by changes in the moisture contents of the foundations zone soils due to the combined effects of following factors:- 1) Soil drying due to tree root desiccation of clay foundations at NE and SW corners inducing soil shrinkage with subsequent settlements of concrete slab in these locations, combined with relatively low rainfall (drought conditions) in Victoria in recent years prior to 2011 2) Seasonal changes in soil moisture contents, which are amplified by nearby trees 3) Highly reactive clay soils at this site 4) Drainage within site is considered to be poor 5) The footings are significantly undersized compared to current standards. The footing probes carried out by [XYZ Testing Services] indicate that the existing concrete edge beams were between 500- 540mm deep, with an overall founding depth of 400-440mm. AS2870- 1996 Residential Slabs and Footing Code requires the edge beam far an equivalent construction of 'masonry veneer' for a house constructed on class H soils to be minimum 700mm deep by 300mm wide. [F Engineers] further notes that the relevant standard at the time of the construction (AS2870-1988) had the same requirement. 6) Possible leak in sewer pipe or water pipe in bathroom under concrete slab – However, a hydraulic investigation would be required to confirm this possible cause. There are significant trees located in relatively close proximity to the subject building. These trees do not meet the recommendations in AS2870, Appendix B (refer Appendix D of this report). Clause B2.3 (c) recommends individual trees should not be located closer to the building than their mature height. This distance increases by a factor of 1.5 by multiple trees. For example, the approximately 10-15m high trees located in the NE section of the subject property should be located at least 15-22m away from the NE corner of the building (whereas they are located within 5-6m). [F Engineers] reviewed the report compiled by [XYZ Testing Services] dated April 2012. This report relates to distress to the NE region of the subject residence in particular. This report opines the previous inundation caused by the burst irrigation pipe in the front yard was a primary cause of the observed distress and movement of the NE region of the residence. Case No: 296936 Determination Page 9 of 11 However, as previously discussed, if the moisture content increased in the clay soils as a result of the inundation caused by previously burst irrigation pipe in the front yard, the soils would be expected to swell (rather than shrink), resulting in local heave. This would be expected to have caused relative heave in the NE region of the house, whereas relative settlement was identified at the subject residence. The observed contours indicate the falls in the floor is relatively uniform towards to the NE and SW regions of the house. [F Engineers’] opinion with respect to the contribution of the previous burst water pipe to the distress differs from [XYZ Testing Services] report, which opines that this is the primary cause of the building distress, for the following reasons: a) If a large volume of the water had flowed under the house and locally saturated the clay soils to the extent that their bearing capacity was significantly reduced, then local settlements of the slab would have occurred. However, in [F Engineers'] opinion, this has not occurred because the falls in the floor are relatively uniform and local settlements at the slab edges were not identified in [F Engineers'] levels survey. b) If local saturation and settlement had occurred as a result of the soil bearing capacity failure, the distress to the structure would have occurred in a relatively short period of time. However, it is stated that the distress to the NE region of the residence, including the garage and bedroom 2, was first noticed approximately 6 months after the Event, and gradually increased over time. c) The levels survey contour diagrams are very consistent with damage to the building occurring as a result of long term drying of the soils due to tree drying influences. [F Engineers] notes that the observed greater movement and distress in the NE region of the building compared to the SW region is likely due to the existence of the 'group' of trees in the NE section of the subject property. d) The [XYZ Testing Services] report stated that "the most likely cause is a reduction in bearing strength in this location. This was possibly caused through the flooding of the site in 2005 with the water softening the immediate founding material, particularly the Clayey Sand Fill which caused settlement of the rear corner of the garage." However, [F Engineers] notes that the [XYZ Testing Services] bore-log indicates that the NE corner of the garage slab (TP1), where the greatest settlement was identified, is founded on Silty Sandy CLAY layer, not Clayey Sand Fill. The floor levels where Clayey Sand Fill was identified (TP2) do not indicate a greater relative settlement at this location. Rather, they indicate the fall in the slab is constant and uniform towards to the NE corner of the garage. [F Engineers] notes that the depth of soil testing carried out by [XYZ Testing Services] was only between 1.0 m to 1.2 m. Soil drying from trees can extend to several metres. It is currently accepted that this depth could be up to 1. 5 times the Hs according to AS2870 (the design depth of suction change). H, is 4.0 m in the Mildura region (semi-arid), hence soil drying from trees could extend to 6.0 m (if the CLAY soil extended to this depth). Although the depth of clay is not known at this site, [F Engineers] expects that the moisture conditions of the founding soils have been affected by the nearby trees to depths well in excess of the testing carried out at this site. Therefore, the results of the soil moisture content testing (carried out at 0.5 m and 1.0 m Case No: 296936 Determination Page 10 of 11 depths) should not be interpreted to determine the likely cause(s) of building movement.‖ Analysis 28. I have carefully examined the expert reports submitted by the parties. 29. It is noted that the author of the report issued by M Engineers is P who has the qualifications ―BE(Hons), LL.B, MIEAust, CPEng‖ written next to his name. 30. XYZ Technical Services’ report was prepared by H, a Senior Geotechnical Engineer. 31. F Engineers’ report was prepared by S ―Senior Forensic/Structural Engineer‖ and reviewed by R ―Technical Manager‖. 32. I accept that H and S are qualified to give an opinion on the cause of damage. 33. H’s and S’s opinions contradict each other. However, I give more weight to H’s opinion because H issued a detailed opinion after conducti ng the necessary soil tests. 34. Notably, M Engineers suggested in its first report that soil tests be conducted. As correctly pointed out by the Applicant, neither M Engineers nor F Engineers conducted soil tests. 35. Thus, I am persuaded by XYZ Testing Servic es’/H’s opinion that drought did not cause the cracking thus: ―It has been suggested that the cause of cracking is due to the drought or a drying of the subsurface profile. It is [XYZ Testing Services’] opinion, that if the drought/drying of the subsurface profile was the main cause of cracking, it would be evident throughout the entire building, and not just in one corner of the garage. This is further backed up by the large gum trees at the southwestern end close to the building. There are several tree roots under the footings, and the material was noticeably drier in this area (TP3). As such, it would be expected that the soil in this area would shrink and potentially cause damage to the building. This is not the case indicating that the footings have wit hstood any seasonal/drying movement.‖ 36. I am also persuaded by XYZ Testing Services’/H’s opinion that: ―Cracking in buildings can generally be attributed to either one or a combination of 3 factors. They are moisture change in the soil creating shrinkage or heaving, insufficient footings for the structure and soil conditions, or insufficient strength in the soil (bearing/shear failure). ... (B)ased on the results of this investigation and the mode of failure with it being restricted to the rear corner of the garage, the most likely cause is a reduction in bearing strength in this location. This was possibly caused through the flooding of the site in 2005 with the water softening the immediate Case No: 296936 Determination Page 11 of 11 founding material, particularly the Clayey Sand fill which caused settlement of the rear corner of the garage.‖ 37. In my view, on the balance of probabilities, the damage to the insured property occurred due to the insured event of bursting or leaking pipes. Further, I note that the FSP carries the burden of proving the app lication of the exclusion relied upon on the balance of probabilities. In my opinion it has not carried the burden of proof. Determination 38. On the basis of the available information and for the above reasons, I determine that the FSP is not entitled to deny the claim and must reimburse the Applicant for actual costs incurred in repairing the garage and bedroom upon presentation of receipts/tax invoices.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.