Home / Financial Firm (Unknown - Insurer) / Determination 293628

Determination 293628

Denial of sewerage overflow claim (exclusion)

FirmFinancial Firm (Unknown - Insurer)
Decided2013-06-06
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

An elderly man whose English is not his first language claimed under his home policy for sewage overflow damage. The FSP denied the claim citing tree-root and faulty-workmanship exclusions. AFCA found the tree-root exclusion unproven, and after new plumber evidence found the FSP had not established the workmanship exclusion, so it ordered the FSP to indemnify the loss.

Once the insured establishes a claim under the policy, the insurer bears the onus of proving that an exclusion applies, and it did not discharge that onus on the evidence.

Issues

Subjects and remedies

elderly or capacityhome or building damagelanguage or cultural barrierpay claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 293628 Determination Page 1 of 7 Case number: 293628 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim - Exclusion/Condition 07 May 2013 Background 1. This is a Determination following the rejection of a Recommendation by the Applicant. 2. A dispute has arisen between the Applicant and the Financial Services Provider, with whom the Applicant held a Home Building and Contents Insurance policy. 3. The dispute relates to the failure by the FSP to meet a claim lodged by the Applicant following an overflow of sewerage from the shower waste outlet and the toilet at the Applicant’s home on 8 January 2012. 4. Full details of the dispute are set out in the Recommendation of 12 February 2013. In essence, the Case Manager who made the Recommendation commented that as two independent experts had identified issues with the workmanship and design of the plumbing syst em at the Applicant’s home, the onus rested with the Applicant to provide evidence to rebut their findings. 5. In the absence of any material provided by the Applicant to rebut the findings, the Recommendation was that the FSP was not required to indemnify the Applicant for the loss. 6. Since the Recommendation, the Applicant has made a further submission (prepared by his son), and more importantly, has supplied an opinion of JRB plumbing. 7. The additional submission and the report by JRB, have been exchanged with the FSP which, however, has not made any further submission. 8. In the circumstances, I am satisfied that the additional submission and the opinion of JRB, are significant. In the circumstances, I have reached a conclusion different to that of the Case Manager, because of the additional material which has now been lodged by the Applicant. 9. I think it most convenient if I set out the Recommendation in full. I shall then make additional comments. Determination Case No: 293628 Determination Page 2 of 7 “1. The Applicant held a home building and contents insurance policy with the Financial Services Provider (FSP) from 30 April 2008 and the policy was current at the time of the loss. 2. The Applicant lodged a claim with the FSP for damage sustained to the lower level of the property as a result overflow of sewerage from the shower waste outlet and the toilet on 8 January 2012. 3. The FSP denied the Applicant’s claim on the grounds that the loss was not caused by a defined event specified in the policy and that it was caused by tree roots and faulty workmanship (of the plumbing system) which are excluded by the policy. 4. The Applicant expects the FSP to accept the claim. Summary of Applicant’s position 5. The Applicant is unhappy the FSP refused to initially lodge the claim and referred him on to the water company (W). 6. He says the damage was not caused by tree roots. 7. There were no tree roots in the sewerage pipes within the property. 8. He disputes the findings of the specialist appointed by W and the loss assessor (C). 9. The Applicant believes the FSP should honour the claim under the policy. Summary of FSP’s position 10. The FSP relies on the expert findings of C and W. 11. The Applicants have not established that the claim was caused by an insured event listed under the policy. 12. The FSP maintains denial of the claim and relies on the following policy provisions: “ Insured event – You are covered for loss or damage to your home caused by ... Bursting, Leaking, discharge or overflow of water or liquids from pipes ... toilets ... drainage and sewerage systems ay your home…….You are not covered for los s or damage caused by an inadequate drainage systems ... at your home. ... Our exclusions (see also General Exclusions, ...) You are not covered for ... Case No: 293628 Determination Page 3 of 7 Loss or damage caused by: ...  an inadequate drainage system. ... What you are not covered for ... You are not covered for any loss or damage caused by or resulting from: ...  inherent defects, structural faults, faulty workmanship or faulty design.  ...  tree roots, tree felling or tree lopping on the site;” Issue 13. Whether the FSP is entitled to deny liability for the Applicant’s claim. Reasons for Recommendation 14. I am satisfied that a full exchange of information has taken place between the parties and that each party has had the opportunity to address any issues raised. 15. The onus of proof rests on the Applicant to establish that, on the balance of probabilities, he has suffered a loss caused by an insured risk. Once the Applicant has established that the loss was caused by a risk insured under the policy, the onus then shifts to the FSP to show that, on the balance of probabilities, the loss falls within an exclusion clause in the policy. 16. The Applicant does not dispute receiving the policy documents and in the circumstances, I am satisfied the FSP has fulfilled its obligations in informing him of the terms and conditions of the policy. 17. The Applicant’s property sustained damage as a result of the overflow of liquid from a toilet/sewerage system and thereby I am satisfied that the Applicant has established a valid claim under the policy. 18. The onus now rests with the FSP to prove its exclusions upon which it wishes to rely. 19. A letter from W dated 3 February 2012 explains the cause of the loss as below: “The blockage and overflow of the sewer line was beyond the reasonable control of [W] within our normal maintenance procedures and could not have been predicted or prevented. On this occasion rampant tree roots broke and invaded [W]’s Sewer system, these roots caused a blockage and in turn surcharge occurred. Case No: 293628 Determination Page 4 of 7 ... This consideration is based in part on private plumbing on the property meeting plumbing standards. An inspection has revealed the surcharge gully serving the property is not set to a compliant plumbing standard and appears to have been raised to the path level. The purpose of the gully is to act as a relief valve and if set to the correct level should allow any surcharge to occur externally when these events occur unfortunately due to the non-complaint private plumbing [W] cannot make consideration of claimed uninsured loss” 20. Subsequent to the lodgement of the claim, the FSP appointed C to investigate the circumstances surrounding the loss and his report dated 18 April 2012 states: “On the morning of 8 January 2012 at approximately 6:00am the Insured discovered sewerage had inundated the lower level of their home due to the overflowing of the toilet and waste outlet of the shower situated on the lower level of their home. The Insured then notified [W] of the incident, who arranged a restoration company to attend to carry out cleaning. The [Applicant] has advised us that there has been ongoing issues at the property since they brought it new 40 years ago, which has required them carry out multiple modifications/upgrades as backing up/overflows is a common occurrence. However they state it has previously been limited to the surge outlet ... However [W] denies that any maintenance works were being carried out at the time and states the blockage was solely caused by the actions of tree roots and that maintenance works were carried out post inundation to help clear the blockage. ... Approximately three years ago the [Applicant] has laid a concrete slab to the rear section of the property around where the surge outlet is positioned. The [Applicant] states that the original pipe work was used and only the top fixture was replaced. Upon inspection we note that a lip has been also added around this point which will increase the head height and resistance of overflow. We have measured the height of this outlet as well as the waste outlet in the shower recess and toilet and note that the height at the top of the surge outlet is equal to the internal waste outlet, however with the addition of this raze concrete lip this has made the internal waste outlet now the lowest point. We therefore agree that the new surge point is non-compliant with the Building Code of Australia and would be classed as faulty workmanship.” (sic) 21. The FSP initially declined the Applicant’s claim on the grounds that the policy excludes cover for claims caused by tree roots. 22. It appears the tree roots had gr own within W’s main sewer pipes and there is no evidence this has extended into pipes within the Applicant’s property referred to as “the site” in the policy wording. Case No: 293628 Determination Page 5 of 7 23. Therefore, I am satisfied the FSP has not established that the claim as caused by the tree roots at the site and therefore is prevented from relying on this exclusion. 24. However, the investigations by W and C revealed the private plumbing work carried out by the Applicant around the area of dispute did not meet the Australian Building Standards. 25. The Applicant says: “ The report by [C] grossly inaccurate. It claims that Multiple modifications and upgrades had to be carried out. He was told that because every time there was a problem with a blockage [W] would insist that we had to call a plummer to ascertain what the problem was before they came out The whole clay line from the toilet in question to near the [W] line was replace with a plastic one. It is a straight piece of pipe no joints. This was done so on the next occasion out household plumming was in good order. Three old clay pipe was in excellent order but we changed it to make sure there was not problem with out plumming. The question of a raise lip on the surge outlet was done at the [W] suggestion to eliminate rainwater entering same it is only about a one inch raise the report tries to make out that this has now causing sewerage to come out of toilet waste by raising the level. On previous occasions sewerage has come out of this surgeoutlet without going inside. Since the concrete floor was replaced in the yard with replace the old one at the same level a new 1 metre grille crate was added to the front door of downstairs area. He conveniently left this out of the report because this crate which joins the surge outlet pipe is approximately 4 inches lower than the surge outlet level so the sewerage should escape from there even before the top of the Surge outlet.”(sic) 26. Based on the above, it appears the issue with W’s sewerage system has been ongoing. However, the Applicant assures that this is the first time the sewerage waste had over flowed inside the property. There had been previous instances where this had occurred outside the property. 27. Since two independent experts have identified issues with the workmanship and design of the plumbing system the onus rests on the Applicant to provide evidence to rebut these findings. 28. I have discussed this claim with the Applicant’s son (representative) affording him an opportunity to provide independent expert evidence to support his view. 29. However he has indicated that the Applicant is not in a position to finance such an investigation and in the circumstances I can only rely upon the expert evidence present before me. 30. In the absence any further evidence to rebut the findings of the FSP, I am satisfied that on the balance of probabilities, the loss was caused by inadequate drainage system and the faulty design and workmanship of the plumbing. 31. The FSP is therefore entitled to rely on its exclusion and deny liability for the claim. Case No: 293628 Determination Page 6 of 7 Recommendation 32. On the basis of the available information, I recommend that the FSP is not required to indemnify the Applicant for the loss. ” Additional Comments 10. I note that in this matter, we are dealing with a claim by an elderly man for whom English is not his first language and I have noted the extraordinary difficulty which the Applicant encountered, in having a claim lodged in the first place. I acknowledge the FSP has subsequently apologised for its actions in this regard, and that as a result of an earlier IDR decision, the claim, in proper form, has been accepted by the FSP for consideration. Nevertheless, it is concerning when one considers that the Applicant has paid his premium but was unable to lodge a claim except by the internet (with which he was not familiar) or by te lephone. 11. On the face of it, there does appear to be some substance to the suggestion made by the Applicant and his son, that the reaction of the FSP was to attempt to sheet home responsibility for this claim to the water carrier “W”. Although not relevant to my consideration of the matter, I note also that W has denied liability for the claim. 12. I agree with the Case Manager who commented that the initial response of the FSP, notably to deny liability for the claim on the basis that the damage had been caused by tree roots, was inappropriate as the influence of the tree roots was not on the Applicant’s property. 13. However, the Case Manager was of the opinion that the investigations revealed that the private plumbing work commissioned by the Applicant did not meet Australian Building Standards. 14. To this, the Applicant makes two points. First, he claims that the raised lip on the surge outlet was carried out at the suggestion of W. Importantly, whilst there had been previous issues occasioned by the maintenance work carried out by W, on no previous occasions had sewerage gone inside. Notwithstanding the raised lip on the surged outlet, the excess had flowed from that outlet. Further, he has pointed out that the effective outlet is some four inches lower than the surge outlet level. 15. Nevertheless, as set out earlier, the Case Manager was, in my opinion, correctly of the opinion that in the absence of any expert evidence from the Applicant, there was sufficient evidence for her to be satisfied that the FSP had met the onus of establishing that it was entitled to rely upon the exclusion for “ inherent defects, structural faults, faulty workmanship or faulty des ign”. 16. The report now supplied by JRB plumbing does appear to address the issue which caused concern for the Case Ma nager. In essence, although JRB ’s report is brief, it does exhibit a diagram of the sanitary drainage on the Case No: 293628 Determination Page 7 of 7 property and the writer of the report makes the point that the drainage was the same as in the diagram except that old clay pipes had been replaced with new PVC in some places. 17. On the basis of this report which the FSP has not responded to, it is very hard to see how the claim that the loss for damage had been caused by either an inherent defect, structural fault, or faulty workmanship or faulty design, can be sustained. 18. I leave aside the question as to whether the changes had, in any event, been recommended by W. This may be a point which the FSP wishes to explore. 19. On the basis of the additional material now submitted by the Applicant, I am of the conclusion that the FSP has not satisfied the onus of establishing that the claim may be denied on any of the bases above. Determination 20. I determine the FSP is required to indemnify the Applicant for his loss.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.