Denial of claim (storm damage)

FirmFinancial Firm (Unknown - Insurer)
Decided2013-03-27
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$87,000
SourceAFCA PDF

Summary

The applicant claimed $87,000 for storm damage to a garage, balcony and house after a February 2011 storm. AFCA found the FSP entitled to deny the balance of the claim after it had accepted repairs to a bedroom ceiling.

Expert evidence showed the damage resulted from long-term roof maintenance, deterioration and faulty workmanship rather than the storm, engaging the policy exclusions.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 286534 Determination Page 1 of 8 Case number: 286534 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim 26 March 2013 Background 1. The Applicant held an insurance policy with the Financial Services Provider (FSP) for an eighty year old residential property. The relevant period of insurance operated for twelve months beginning from 11 March 2010. During this period, the building was insured for a sum up to $1,800,000 and contents for $400,000. The majority of claims were subject to a $500 excess. 2. The Applicant completed a claim form on 11 May 2011 for damage that occurred on 4 February 2011 following a severe storm. The following description was provided: “Water damage & tree damage (tree fell onto garage) to garage structure and minor damage to contents in garage.” 3. The Applicant included a quotation with the claim form in the sum of $87,000. The scope of works included storm damage to the garage, balcony/carport and main building. 4. Upon engaging an engineer (E) and a roof plumbing & tiling expert (RC) to review the claim, the FSP decided to accept the cost of repairs to the internal damage to the ceiling within bedroom 2 but deny the balance. The Applicant has disputed this decision. Summary of Applicant ’s position 5. The Applicant is represented by his broker. For the sake of convenience, reference to the Applicant will include his broker. 6. Although there were some maintenance issues with the property, the storms of February 2011 were of such severity that it was inevitable that his property would sustain water damage. In this regard, he relies on the following:  The Bureau of Meteorology records which show approximately 112.6mm of rain fell within a 3 day period (4 to 7 February 2011).  A report from a structural and civil engineer (SE). Determination Case No: 286534 Determination Page 2 of 8  The fact the property had not sustained damage in the preceding two years. 7. Given this, the Applicant submits the FSP should account for the damage that would have inevitably been caused by the storm. Summary of FSP’s position 8. The FSP relies on the expert evidence of E and RC as well as the following policy provisions to maintain its position: “ General Exclusions These apply to the whole Policy Unless otherwise stated in the Insurance Schedule, this Policy does not cover: 1. loss of or damage to Your property which is caused by: (a) wear, tear, rust, corrosion or gradual deterioration (b) mechanical breakdown, electrical breakdown, faulty workmanship, inherent defect, omission or design.” Issue 9. Whether the FSP is able to rely on the relevant exclusion cla uses to deny the balance of the Applicant’s claim. Reasons for Decision 10. As advised by the parties, due to the amount in dispute, the matter has been referred to the Panel for Determination in line with the Operational Guidelines to the Service’s Terms of R eference. This dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination. 11. This decision has been made by a Panel consisting of an Ombudsman, a representative with extensive experience in the insurance industry and a representative with extensive experience in consumer claims. 12. The FSP is seeking to rely on an exclusion clause and therefore has the burden of establishing on the balance of probabilities that it applies. Expert Evidence 13. Both parties have relied upon expert evidence to substantiate their position. The FSP has relied upon E and RC whereas the Applicant has provided a report from SE. Case No: 286534 Determination Page 3 of 8 14. E was engaged to inspect and report on the first floor balcony and rear garage; it provided a report dated 11 June 2011 that contained photographs in support and the following of relevance (headings have been placed for convenience): Balcony  The damaged balcony is the flat top of a carport that stands over the side driveway. This area has been tiled with ceramic tiles set out in a basket weave pattern with mortar jointing.  The balcony is a square area approximately 3m by 3m. The tiled area is a flat plane that slopes gently to a drain in the rear. The tiles were of a glazed ceramic type. The whole tiled area however had been covered by a white plasticised material later found to be “Gripset” Liquid Rubber Membrane.  The membrane extended up the walls surrounding the tiled area but much of this had been peeled off. It is quite obvious this membrane had been applied many years ago.  This membrane has been used on an area that is walked over despite the manufacturers of “Gripset” warning parties against this. In addition, it was not meant to be used over glass or a glazed surface.  The reason for the use of the membrane was due to the joints between the tiles showing signs of distress, with efflorescence oozing from them. This indicates the substrate under the tiles has broken down and the waterproofing measures undertaken to the tiled area has been compromised. This would not have occurred from a single storm, particularly not a storm on 4 February 2011.  The ceiling under the balcony was both damp and stained, indicating that a lot of water has flowed onto and through this ceiling for a long period of time. Garage  The garage is a massive brick structure with a pitched terracotta roof. A corner of a parapet around the roof is leaning over and may fall. The insured claimed this was impacted by a tree in the storm on 4 February 2011. If a branch had been large enough to cause this damage, then it is reasonable to presume this would have damaged the adjacent fence. However, this was not the case.  The ceiling has been damaged and is sagging as though it has been affected by water over a period of time. The hole in the corner looks as though it has been cut, presumably to let water out.  The roof drains into a box gutter behind the parapet. There is no doubt that various storms would have overwhelmed the gutter, allowing water to flow into the ceiling.  The garage appears to be suffering from neglect. Ivy is also growing inside the garage. Case No: 286534 Determination Page 4 of 8  The parapet has been damaged but it is unlikely this was caused by a single event of storm. The brickwork below this corner appears to be free of cracks but there is a lot of vegetation around there. It is possible repeated impact from branches may have affected these bricks. 15. Following this, E concluded the following: “Neither the damage to the tiled balcony nor the garage have been caused by a single storm event – certainly not the storm on 4 February 2011. Both areas of damage show long- term characteristics.” 16. RC provided a report dated 27 June 2011. The report was to address the rainwater ingress into the house, in particular the front and second bedroom, the carport and the garage. In furtherance of this, he conducted an inspection of the roof. 17. The Panel does not propose to repeat all of RC’s findings in the body of the Determination since this has been exchanged with the Applicant. It is sufficient to reiterate his relevant conclusions regarding these issues: “ Point 1 Rainwater leakage that has occurred into the front bedroom of the house is the result of leaking from a chimney Lear Gutter. The chimney Lear Gutter is in an advanced state of deterioration with extensive rust hols evidence and as such, all leakage is due entirely to a longstanding roof maintenance issue. Point 2 Rainwater leakage is occurring into a second bedroom to the southern side of the house again around the site of a chimney installation. Rainwater is leaking from the second chimney due to faulty workmanship that sees the replacement of the original Lear gutter with a new gutter. The workmanship involved with the installation of the new gutter is obviously NOT(original emphasis) the work of a qualified or experienced plumber and presents as the work of a complete amateur unlicensed person and the resultant water ingress, is entirely attributable to faulty non-compliant workmanship issues. Point 3 Rainwater leakage that is occurring from the ceramic tile balcony of the carport is the result of a combination of badly rusted box gutters, box gutter also has NO (original emphasis) effective overflow system and also, significant deterioration to the waterproofing membrane installed atop the ceramic tile balcony. All rainwater ingress that is causing damage to the ceiling of the carport presents as a obvious roof maintenance issues – NOT (original emphasis) storm created. Point 4 Rainwater leakage that is occurring into the garage is again the result of faulty workmanship in regard to leakage from the box gutter and in the case of damage to the metal hanging flashing this has been caused by the growth of Case No: 286534 Determination Page 5 of 8 a tree within the brick parapet wall of the garage, which should not have been allowed to have occurred. Point 5 No storm damage or storm created openings to the roof My inspection of the entire roof to this house, the garage and the ceramic tile balcony to the carport found NO (original emphasis) evidence of any storm damage of (sic) storm created openings of any kind. To the contrary, this house lacks appropriate maintenance works to the roof for a considerable period of time. It is this lack of proper maintenance and the faulty w orks that have cause (sic) the leakage issues to this property.” 18. SE’s report of 28 September 2011 contained the following:  Two areas adjacent to the chimneys in the bedrooms exhibited water damage through the plaster in the ceiling. This is obviously associated with a leak in the roof cladding.  A similar problem with a leaking roof has occurred in the north-east corner of the garage.  The balcony over the existing carport has exhibited damage to the ceiling from excessive water leakage. A visual inspection revealed the balcony inadequately graded and the applied waterproofing compound having broken down. The application of this membrane occurred after the storm according to the owner. Further, the owner stated the balcony floor had been submerged in 75-100mm of water. 19. Based on the above, SE concluded that: “Whilst it is probable that the damage has been an ongoing maintenance problem with roof leakage, the storm in February 2011 has exacerbated the problem. Roof guttering and downpipes would not be able to accommodate for storms of significant magnitude and as a result flooding and/or excessive water leakage has occurred. The amount of damage directly caused by the storm damage is difficult to quantify at this point in time, but some extent of damage, to the ce iling has been caused by the storm.” 20. The FSP provided SE ’s report to E who responded in an email dated 11 January 2012 with the following: “... I see no broad area of disagreement between what I said in my Report and what [E] has said. I note that our original instructions ... did not include the main roof of the house. As a consequence, I did not pay particular attention to the roof or the interior of the house. ... From what I can see, the gutters of the house appear to be at least a metre or more from the external walls and the gutters and downpipes appeared to be in reasonable order. Even if they overflowed I would not expect that water would run onto the ceilings of the house. It is possible that a massive rain event like that which occurred on 4 February 2011 may have overwhelmed flashings and allowed water to flow inside. I do not think that this is likely mainly because this house appears to have been very well built in an era and location where things like the roof drainage were properly designed and built. Case No: 286534 Determination Page 6 of 8 There have been plenty of heavy rain events since the 1930s and 40s so the chances of the 4 February storm sending water to a ceiling are not very high. On the other hand, a leak in the roof cladding (ie a cracked tile), could allow water to flow in. As you know however, I was not required to access the roof so I cannot comment on whether there are any cracked tiles. [SE] attributes the damage he saw to ongoing maintenance, exacerbated by the storm. I do not think it is at all possible to quantify damage by one cause or the other. Therefore, for reasons given above, I would attribute all of it to ongoing maintenance problems – subject to another inspection.” Consideration of the evidence 21. The substantive argument presented by the Applicant is that regardless of the condition of the property, the storm event of 4 February 2011 was significant enough to have resulted in some damage. However, the expert evidence does not appear to support this. 22. In particular, both reports to the FSP highlight numerous iss ues that appear to explain the cause and source of the water ingress to various parts of the property. The Panel will expand on this. Bedroom 1 23. According to both RC and SE, the water ingress to the house was localised to bedrooms 1 and 2. As the FSP has accepted the internal repair cost to bedroom 2, the Panel will limit its review to bedroom 1. 24. In regard to the water ingress to bedroom 1, RC identified that this was due to the Lear gutter being extensively rusted with rust holes evident. E, by its own admission in its email dated 11 January 2012, did not pay particular attention to the roof or interior of the house. This is not surprising given RC would have been more appropriately placed to opine about this issue. 25. Accordingly, despite E indicating that it was possible for storms to have resulted in water ingress (although he considered this unlikely), the Panel prefers to rely upon RC’s opinion as it was based on a visual inspection and investigation regarding the cause of this water ingress. 26. RC’s explanat ion of the cause of the ingress is supported by photographs and is reasonable and plausible. In addition, SE’s report does not dispute these findings. In particular, it is unclear if SE actually inspected the roof as his report is silent on his observations in this regard. For instance, although he comments on there being a leak in the roof, he does not expand on how this leak occurred. 27. Given this, the Panel accepts RC’s evidence about the source of the water ingress into bedroom 1. In particular, the Panel accepts that the proximate cause of the leakage to this area would be wear, tear and rust as opposed to the storm. This is based on the fact it is reasonable to accept that if the Lear gutter was in good, serviceable condition, it is unlikely water would have penetrated this part of the home. Case No: 286534 Determination Page 7 of 8 28. Although SE has provided a broad conclusion stating that the magnitude of rainfall would have exacerbated and caused resultant flooding, the Panel is not persuaded by this given he has not considered whether a properly installed Lear gutter would have avoided the water ingress. In the Panel’s view, having considered the extensive deterioration and holes as evident in the photographs, it is more probable than not that this was the cause of the ingress, not the storm. 29. The FSP is therefore entitled to deny this aspect of the Applicant’s claim. Carport Balcony 30. In regard to the carport balcony, the Panel is particularly persuaded by E’s evidence in this regard. E has provided a plausible explanation as to how a balcony appropriately waterproofed could have this ability compromised and why this is unlikely to have occurred from the storm. In support of his conclusion, he referred to the leakage in the ceiling as being evident that this was occurring for a long period of time. 31. SE’s evidence has not refuted this analysis. Instead, it provides some corroboration to E’s conclusion given he identified excessive leakage and inadequate grading. 32. RC also provided further support to E’s position and expanded on this by identifying that the box gutter has no overflow system, which is a vital omission. 33. In the light of all of this, the Panel is persuaded that the damage to the carport balcony was due to gradual deterioration and/or faulty workmanship. Accordingly, the FSP is entitled to rely on the exclusion clauses associated with those causes to deny this aspect of the Applicant’s claim. Garage 34. The Panel is persuaded by RC’s evidence in this regard, particularly given the following issues he identified:  The inappropriate tree growth causing the hanging flashing, which was installed as the waterproofing agent to a box gutter, being compromised.  The inappropriate use of a nail through the box gutter.  The box gutters being in an advanced state of deterioration and containing no overflow system. 35. This was supported, to an extent, by E as he believed the issues identified in the garage were long term rather than caused by one event. SE’s report also appeared to provide some support to the fact that a leak in the roof cladding occurred although he was not specific as to how the leak occurred. 36. Although SE, in his broad conclusion, stated that the roof guttering and downpipes would not have been able to accommodate the storm, it is Case No: 286534 Determination Page 8 of 8 unclear whether he arrived at this conclusion having taken into consideration the above three issues identified by RC. In this regard, the Panel prefers RC’s evidence given he has specifically identified the extent of the faulty workmanship and deteriorated issues which, on the face of them, readily lead to the conclusion that these factors were the cause of the loss, not the storm. 37. Accordingly, the Panel accepts the FSP is entitled to deny liability for this aspect of the Applicant’s loss. Determination 38. On the basis of the available information the Panel determines the FSP is entitled to deny the balance of the Applicant’s claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.