Determination 285652

Underpinning and structural repairs denied under earth movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2013-03-28
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$26,000
SourceAFCA PDF

Summary

The applicant's claim for about $26,000 of underpinning and structural repairs to cracked hallway walls was denied under the earth movement exclusion; the FSP had paid $3,700 for cosmetic damage. AFCA found the FSP was entitled to deny the structural repairs and ordered nothing further.

Under the Wayne Tank concurrent-cause principle, the excluded earth movement prevailed over a possible leaking pipe, so the structural repair claim was excluded.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 285652 Determination Page 1 of 6 Case number: 285652 General Insurance - Domestic Insurance - Home Building – FSP’s decision – Claim amount 28 March 2013 Background 1. The Applicant is insured with the Financial Services Provider (FSP) under a home building insurance policy that provides accidental damage or loss cover. The relevant period of insurance is 28 May 2011 to 28 May 2012. 2. On 9 June 2011 the Applicant contacted the FSP. He advised he had arranged underpinning to be carried out at the property due to cracking occurring to internal walls. During the underpinning process water was discovered under the property. 3. The FSP arranged for a builder to attend the site and provide a report. However the builder was unable to report on the cause of damage. The FSP appointed an external loss adjuster (YDR) and consulting engineer (MP) to attend the property and report on the cause of the problems experienced at the Applicant’s property. 4. When the YDR and MP attended the property they found that underpinning works had been completed. YDR noted wall cracks were primarily within the central hallway. Nevertheless, both YDR and MP believed the cause of damage was related to earth movement, even though a pipe that was servicing the bathroom was said to be leaking. 5. The Applicant sought indemnity under the policy for the cost of underpinning and associated repair but the FSP has denied the claim as the policy excludes damage caused by earth movement. 6. The Applicant disagreed with the FSP’s decision and sough t review of its decision through the FSP’s internal dispute resolution process (IDR). 7. The FSP deemed there was a possibility the leaking pipe may have contributed to cosmetic damage and has paid $3,700 being a 50% contribution to cosmetic repairs. 8. The Applicant says he has expended approximately $26,000 in costs relating to underpinning and rectification works as he considered this work was required. Determination Case No: 285652 Determination Page 2 of 6 Summary of Applicant’s position 9. The Applicant says he arranged underpinning of strip footings due to internal cracking to walls. During the underpinning process a large amount of moisture was found and the plumber detected a crack in a pipe. 10. He says he has lodged a legitimate claim and the FSP is going out of its way to reject the claim. 11. The Applicant says the FSP has appointed people for the purpose of disproving the cause of damage was the leaking pipe. 12. He says the FSP has only offered to pay $3,700 out of an approximate cost of $26,000. Summary of FSP’s position 13. The FSP submits the damage to the Applicant’s property is from “ movement of earth” which is a cause specifically excluded by the policy. 14. It says it has reached this conclusion based on the obtained expert reports from YR and MP. 15. The FSP says that although the Applicant says he has had independent professionals observe his property who have conflicting views to its opinions, this has not been substantiated. 16. The FSP says in recognition that YDR indicated it was possible a leaking sewer pipe has contributed to soil heave at the rear of the property it has made a payment of $3,700 as a contribution towards damage it believes would have been only cosmetic had the underpinning not taken place. 17. The FSP relies on the following policy provisions: “ Accidental Damage cover We will cover your buildings or contents for any accidental loss or damage. There are also a number of incidents we will cover under specific conditions – these are listed on the following pages. If you make a claim, you will need to pay any excesses that apply – you will only need to pay this amount once. Any cover we provide is subject to exclusions. For exclusions to this cover, see page 31. ... Exclusion to your cover Any cover we provide is subject to the following exclusions. We will NOT cover any loss or damage as a result of, or caused by  Settling, shrinkage or any earth movement ” Case No: 285652 Determination Page 3 of 6 Issues 18. Whether the FSP was entitled to refuse to indemnify the Applicant for the full cost of underpinning and associated repairs. Reasons for decision 19. FOS has considered it is appropriate to expedite the dispute in accordance with clause 8.6 of the FOS Terms of Reference. This is because of the issues in dispute. This dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination. 20. There has been an exchange of material between the parties and I have considered carefully all the material and arguments. It therefore is not intended to recite all the details of the material exchanged in this Determination except where considered relevant. 21. The Applicant has accidental loss cover to the building as well as cover for insured events under specific conditions; one of which is “ water or liquid damage ” . Nonetheless, any events covered by the policy are subject to exclusions as set out in the policy. 22. The courts have determined that in order to decide whether the damage is covered by the policy, the proximate cause of the damage must be established. The proximate cause is not necessarily an occurrence which is last in the point of time but rather the dominant factor in the damage. 23. It is also well established law ( Wayne Tank and Pump Co. Ltd v Employers’ Liability Assurance Corp. Ltd. [1973] 3 AII E.R. 825) that where there are two effective causes of a loss, one of which is excluded and one which is included in an insurance policy, the excluded clause operates to over-ride the included clause and defeats the claim. 24. The Applicant says it has never been clarified as to why there is a massive amount of moisture under the foundations. He says it is not possible to come from natural causes and has to have come from a leaking pipe or sewer. He needs the cause of the moisture solved. 25. He says he does not expect the FSP to cover the whole amount of the claim. He also understands old houses crack from time to time from natural causes but this is not what has happened in this circumstance. 26. The Applicant provided a building report (BB) following inspection of the property on 23 August 2012. This was exchanged with the FSP and it provided copies to YDR and MP for their opinions. 27. In BB’s report he concluded: “Soil beneath the wet are a floor was saturated from the fractured sewer riser. This has caused foundation work to settle at the bathroom passage area and Case No: 285652 Determination Page 4 of 6 made masonry walling. To the lounge rotate longitudinally with its length and fractured passage arch. Masonry hall walls have been subject to ground movement.” 28. In BB ’s report there is reference to earthquakes having occurred in the region in 1954 and 2010. However, there is nothing to suggest the hallway damage is earthquake related. 29. The FSP maintained its position that the damage resulted from earth movement in light of the further opinions from YDR and MP in response to BB’s report . 30. I have analysed the material including the various reports submitted for consideration. 31. The claim relates to damage caused to hallway walls. It is asserted the cracking has been caused by excessive moisture in the soil. Investigative work was undertaken to establish the cause of moisture. The Applicant had underpinning works completed before the FSP’s experts had the opportunity to comment. YDR and MP did not believe it was necessary for this work to have been undertaken. 32. According to the MP no underfloor leakage was discovered and the fractured waste pipe is some distance away from the dwelling’s hallway and also downhill from it. This pipe was repaired. 33. YDR was satisfied based on the available evidence the loss was due to soil movement but indicated to the FSP that if it wished to give any benefit of doubt to the Applicant that the leaking sewer pipe may have slightly contributed to the observed damage. 34. At the same time I have noted the evidence as to rainfall recorded in the YDR reports. There was a significant spike in rainfall shortly before the severe cracks developed, and for the years thereafter, rainfall was much higher than average. 35. The FSP offered the sum of $3,700 being the cost of cosmetic damage less the policy excess of $100 on the basis that the leak in the sewer pipe may have contributed to damage. 36. I noted in BB’s report he stated: “The owner said he called in a plumber with CCTV drain camera to inspect the pipework and found a crack in the pipework beneath the bathroom floor and the sewer riser was also found damaged at the bottom elbow that drained the bath, shower and hand basin to the soakage pit. 37. Whereas the plumber reported: 1. The external elbow feeding downstream of IO (A) adjacent the veranda wall penetration was noted to be completely broken. 2. The grease trap PVC collar was noted to be slightly cracked. Case No: 285652 Determination Page 5 of 6 3. No leakage was able to be recorded for the bathroom floor filling with water.… 38. It would appear BB has made his report on information given to him by the Applicant rather th an relying on the evidence of the plumber’s report that establishes what leakages there were at the property. 39. The FSP gave the Applicant some benefit of the doubt that a fractured sewer may have contributed to some cosmetic damage. 40. The Applicant needs to establish he has suffered a loss covered by the policy. He may have an insurable item under “water or liquid damage” on page 14 of the policy, as the Applicant maintains that a principal objective is to identify the source of the leak. 41. YDR and MP’s report suggest the hallway cracking has occurred from earth movement which is excluded by the policy. 42. BB’s report also makes mention that “Masonry hall walls have been subject to ground movement”. I accept “ground movement” falls within the terminology to describe earth movement. The policy excludes damage caused by “settling, shrinkage or any earth movement”. It follows that any damage arising from ground movement is excluded from cover provided by the policy. 43. I am satisfied the dominant factor for the loss was earth movement and a leaking pipe may have been a factor and , if it is, it is an event covered by the policy. I am also satisfied that in these circumstances the doctrine of two proximate causes apply. I refer to the Wayne Tank principle set out in paragraph 23 above. 44. I am satisfied the loss has been caused by an event excluded by the policy and the exclusion prevails over the leaking pipe event. Although a leaking pipe may have contributed to cosmetic damage, that was a concurrent interdependent cause of the damage and the Wayne Tank principle applies. 45. On the balance of probabilities, I am not satisfied the damage and all claimed repairs were caused by an event covered by the policy but by an event excluded by the policy. 46. The Applicant’s position is made muc h more difficult by reason of the fact that he went ahead with the works before affording the FSP an opportunity to respond to the claim. Determination 47. On the basis of the available information I determine the FSP was entitled to deny the claimed cost of structural repairs. 48. I note the offer of $3,700 for cosmetic damage. Case No: 285652 Determination Page 6 of 6 49. The material available to me does not permit me to determine if the Applicant has a claim pursuant to “Water Damage” on page 14 of the policy, whilst I note that experts have commented that the damage is greater in the wet area.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.