Home / Financial Firm (Unknown - Insurer) / Determination 285621
Determination 285621
Denial of claim - whether the FSP has fulfilled its obligations
Summary
A homeowner claimed for storm damage to her roof and paid $9,543.42 to a repairer after the FSP denied the roof as wear, tear and design defects. The Panel found a link to faulty 1991 repairs covered by a lifetime guarantee and ordered the FSP to pay 60 per cent of the repair cost plus interest.
The FSP had not shown the 2011 water damage was unconnected to its 1991 roof repairs, so AFCA apportioned the loss under term of reference 8.2 given the applicant's long enjoyment of the roof.
Issues
- Repairs or contractors primary · upheld
“I am not satisfied that the FSP has established there is no link between the 1991 repair work and the 2011 water damage claim.”
- Claim denial secondary · upheld
“I believe it is appropriate to apportion the Applicant's cost of repairs in the sum of $9,543.42 on a 60/40 basis in favour of the Applicant.”
Subjects and remedies
home or building damagepay compensationpay interest
Text of the determination
Case No: 285621 Determination Page 1 of 9
Case number: 285621
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of Claim - Whether the FSP has Fulfilled its Obligations.
28 February 2013
Background
1. This is a review of a Recommendation by the Service’s Case Manager dated
19 December 2012. The Applicant has rejected the Recommendation and in
accordance with the Terms of Reference, the matter has been referred to me
for Determination.
2. The matter has had a very long history extending back more tha n 20 years
but the relevant background, summaries of the parties’ position and issue in
this dispute are set out in summary in paragraphs 1 to 12 of the
Recommendation. I will restate same.
“1. The Applicant holds a Home Building insurance policy with the Financial
Services Provider (FSP). On 19 March 2011 the Applicant lodged a claim with
the FSP for storm damage. The claim related to roof damage and damage to
the home’s interior.
2. The Applicant said the FSP did not properly repair the roof damage for which
she claimed in 1991. The Applicant contends this unsatisfactory repair work
contributed to her loss in 2011.
3. The FSP has accepted the claim for all internal damage that was identified as
having been caused by the storm, however it does not accept the Applicant’s
contention that faulty repair work in 1991 contributed to her loss. Instead, the
FSP said the issues relating to the roof were due to wear and tear, in addition
to lack of maintenance and a faulty building design.
Summary of Applicant’s position
4. The Applicant suffered storm damage in March 2011 which resulted in
damage to both the interior and exterior. The Applicant said the FSP had
failed to properly repair her roof after she lodged a claim in 1991 for storm
damage.
5. The Applicant said she has paid a repairer $9,543.42 to repair part of the roof
since the FSP has denied the claim.
6. The Applicant wants her home to be “restored to the original design
specifications”.
Determination
Case No: 285621 Determination Page 2 of 9
Summary of FSP’s p osition
7. The FSP arranged a building consultant to attend and report on the damage
after the Applicant lodged a claim for storm damage on 19 March 2011.
8. The FSP offered to settle the claim with respect to the damaged interior and
contents. However, the Applicant refused the offer stating that she wanted the
FSP to address the issues relating to the 1991 claim.
9. The FSP denied the claim with respect to the Applicant’s roof as the issues
concern wear, tear and deterioration in addition to an inadequate box gutt er.
The damage is not due to storm damage, nor does it have any connection
with the 1991 claim.
10. The FSP obtained two reports which concluded the water entry into the
Applicant’s home was not due to an opening created by a storm. In addition,
the Applicant had obtained a report which concurred with this.
11. The FSP relies on the following policy provisions:
“ The exclusions shown in this section apply
to all cover under your policy.
What we don’t cover
Loss, damage, injury or death arising from:
>wear, tear, rust, corrosion or deterioration
…
Maintaining and occupying your home
We don't cover loss, damage, injury or death
arising from:
>you not maintaining your home in good
repair and condition. This means your
home must be watertight, structurally
sound, secure and well maintained
…
> faulty design or workmanship that you
knew about or should have reasonably known about ”
Issue
12. Whether the FSP has fulfilled its obligations under the policy. ”
Reasons for decision
3. There has been a full exchange of information and each party has had an
opportunity to address the issues that have been raised.
4. In making his recommendation, the Service’s Case Manager set out his
reasons in paragraphs 14 to 40 and I will restate same :
Case No: 285621 Determination Page 3 of 9
“ Claim
14. On 19 March 2011, the Applicant lodged a claim with respect to storm
damage to her property. The FSP recorded that:
“Due to storms water has leaked via the roof and thru [sic] the timber
ceiling into the bedroom, hallway and two bathrooms. Damage to the
carpet in the bedroom and the wardrobe.”
Assessment
15. The FSP arranged an assessment of the damage and this was carried out on
21 March 2011. The assessor provided a report along with a number of
photographs in support. The assessor noted:
“…An inspection of the roof found that a box gutter had overflowed into
the roof space. A tiled section of the roof has numerous silicone repairs to
the tiles and cappings and timber barge boards and linings are in very
poor repair. The roof is in poor rep air…
Conclusion: The main water ingress is as a result of box gutter overflow.
This claim has minimal damage, considering the condition of the roof.”
Architect’s report
16. The Applicant arranged for an architect to carry out an inspection. The
architect produced a report on 11 September 2011 in which he referred to the
eastern gable roof and said that:
“… water entering along the south edge of the gable roof … is almost
certainly due to torn sarking below the tiles. This allows rainwater from
the tiles to run behind the fascia and gutter, into the ceiling space and
down the walls of the hallway …
Box gutter on southern section of “flat” roof; in all probability caused by
rainwater backing up and flowing under the existing metal deck roofing
and through weaknesses in the old membrane and/or membrane-gutter
joints. This is aggravated by frequent blockages in the gutter and
downpipe outlet from leaves and other eucalypt “debris” seriously
hindering the water flow.
We do not believe that this problem can ever be resolved while the box
gutters are retained. Indeed, we hold the view that when the storm repair
was carried out, particularly with the introduction of metaldeck [sic], the
box gutters should have been eliminated.”
17. The report concluded that:
“There i s little doubt that most of the problems stem from the approach
taken for the original repair work, whereby metal deck roofing was fixed
over the damaged membrane without proper regard for correct falls and
elimination of the box gutters. Notwithstanding the problems this has
caused over the past 20 years, we believe there is a fairly simple solution
that will once again make the home comfortable and watertight.”
Case No: 285621 Determination Page 4 of 9
Building Consultant’s report
18. The FSP arranged for a business consultant to inspect the property. The
building consultant had the benefit of viewing both the assessor’s and the
architect’s reports.
19. The building consultant’s report dated 23 September 2011 included a number
of photographs in support. The report noted:
“This dwelling was the subject of a report by me 19 years ago for
recurring rainwater ingress into the dwelling subsequent to [the FSP]
approved repairs arising from storm caused damage that occurred on
January 21 1991. I confirm that I have read this report.”
20. The report indicated the Applicant is contending there are recurring water
ingress issues which have arisen from the FSP’s roof repairs effected
following the 1991 storm damage claim. However, the building consultant
disagreed with the Applicant’s assertion that water intrusion was a recurring
problem, after having inspected the various rooms in the home.
21. The building consultant made the following conclusions on the concrete tile
roof above:
Bedroom 3 – Poor workmanship, albeit minor. Ridge cap bedding
devoid of weep holes. Internal construction vulnerable to rainwater
ingress via the porous bedding. Defect presumably relates to the roof
repairs undertaken by an [FSP] contractor following the 1991 storm
event. Roof defect has not caused any resultant damage to bedroom 3
because at the time of inspection the bedroom exhibited no evidence of
water damage.
Hallway – Rainwater ingress onto ceiling is due to natural wear and tear
considerations. Roof defect is unrelated to the roof repairs undertaken
by the FSP’s contracto r following the 1991 storm event.
22. The report also made the following conclusions on the metal roof cover
above:
Bathroom – Rainwater ingress is due to breakdown from natural wear
and tear of the silicone sealant at skylight/metal roof cover interface.
Roof defect unrelated to roof repairs undertaken by FSP’s contractor
following 1991 storm event.
Bedroom 4 – The under-pitched roof cover is not the primary cause of
rainwater ingress into the bedroom, the box gutter is the culprit.
Ensuite – The roof is under-pitched but there is no indication of
rainwater ingress into the ensuite.
Policy exclusion
23. The FSP is relying on a policy exclusion of wear, tear and deterioration to
deny the claim. The FSP is also relying on a failure to maintain the property
a long with a faulty building design. The FSP has referred to the assessor’s
report, in addition to the building consultant’s report in support of its position to
deny liability for the claim.
Case No: 285621 Determination Page 5 of 9
1991 storm damage
24. The Applicant contends that the FSP’s contr actor did not properly repair the
storm damage her home suffered in 1991 and this failure contributed to the
damage incurred as a result of storm damage in March 2011, twenty years
later.
25. The Applicant has provided considerable comment on this issue in her
submissions to the Service. She has addressed the various comments made
by the building consultant and the assessor. In addition, she has provided
photographs to illustrate some comments.
26. The Applicant referred to the building consultant’s report dated 6 April 1992
and contends the comments made in that report undermine the building
consultant’s report dated 23 September 2011. I note in this respect the
building consultant said in his most recent report that he had read his earlier
report. Therefo re, he was aware of his previous comments and the Applicant’s
ongoing concerns about the previous repair work. He has addressed these in
his report.
27. While the Applicant has provided detailed comment on this particular issue,
this needs to be supported by evidence which corroborates those comments.
In this respect, the Applicant obtained an architect’s report which provides an
outline of the problems in addition to proposed solutions.
28. The report states that there appears to be two locations where water is
penetrating the Applicant’s home. One location is the eastern gable roof
where the penetration “is almost certainly due to torn sarking below the tiles”.
The other location is the box gutter on the southern section of the “flat” roof.
29. The architect said that the water penetration is:
“… in all probability caused by rainwater backing up and flowing under
the existing metal deck roofing and through weaknesses in the old
membrane and/or membrane gutter joints. This is aggravated by frequent
blockages in the gutter and downpipe outlet from leaves and other
eucalypt “debris” seriously hindering the water flow.”
30. The architect also said that he did not believe the problem concerning water
penetration could be resolved while the box gutters are retained. He
suggested alternatives to box gutters, in addition to other modifications which
he believed are necessary to rectify the problem.
31. The architect concluded there was:
“…little doubt that most of the problems stem from the approach taken for
the original repair work, whereby metal deck roofing was fixed over the
damaged membrane without proper regard for correct falls and
elimination of the box gutters.”
Whether there is a link to the 1991 claim
32. However, these matters essentially concern design defects instead of
rectification of damage resulting from an event for which the policy responds.
The architect’s report does not support the Applicant’s assertions that the
repair work from the 1991 claim is responsible for the Applicant’s loss in 2011.
Case No: 285621 Determination Page 6 of 9
33. In addition, the building consultant had the benefit of considering the
architect’s report and he was also involved in the 1991 claim as well as the
2011 claim. He had also reviewed his 1992 report. The building consultant
provided a comprehensive report which itemised the damage to each affected
room within the Applicant’s home. The building consultant’s report clearly
concludes there is no link between the 1991 repair work and the 2011 water
damage claim.
34. Overall, the information before the Service is insufficient to link the water
damage of 2011 with the 1991 claim where the Applicant said that the FSP
failed to properly repair the damage which occurred on that occasion.
35. Further, the 1991 claim occurred twenty years prior to the 2011 claim and
therefore a number of other factors would have impacted on the Applicant’s
home during subsequent years. A home requires ongoing maintenance in
order to ensure it remains watertight. There are too many intervening years
between the two claims to link the current claim with the 1991 claim.
36. In addition, I note the Applicant completed a customer survey form seven
years ago in November 2005, after the FSP had finalised her 2003 claim. This
form recorded the Applicant’s high level of satisfaction with the FSP.
37. The Applicant commented as follows:
“Damage exacerbated by previous very unsatisfactory storm damage
repair … early 1990’s.
Claim not satisfied to repair surface damage with original problems
unsolved [sic].
Negotiations re repairs being retrospective & included fixing problems
due 1 st repairs by unsatisfactory tradesman in early 1990’s.
Repairs carried out to owner’s satisfaction & very satisfied with this
builder’s & [FSP’s] response. Thank you.”
38. This would suggest the issue relating to the 1991 repair work had been
resolved to the Applicant’s satisfaction and was no longer an issue.
Settlement offer in relation to 2011 claim
39. The FSP outlined in its Notice of Response those items for which it had made
a settlement offer in relation to the 2011 claim. These matters included:
carpet; wardrobe, wall damage, electrical restoration; damaged wooden
ceilings.
Conclusion
40. The FSP has provided sufficient evidence in support of its position that the
water damage in relation to the 2011 claim has not resulted from an insured
event, such as a storm. The information provided to the Service, including that
of the architect’s report, confirmed the damage resulted from a combination of
factors such as wear, tear and deterioration. Other contributing factors include
a faulty building design and lack of maintenance. ”
Case No: 285621 Determination Page 7 of 9
5. I have read all the exchanged information and I have considered the parties’
submissions including the Applicant’s further submission dated 18 January
2013. I have been assisted by the photographs and diagrams submitted by
the Applicant and the FSP.
6. I agree with the Case Manager’s reasoning in paragraphs 14 to 31 but I have
taken a different view in respect of the link between the work undertaken by
the Applicant in April 2012 and the work carried out by the FSP’s builder in
respect of the 1991 claim. The Service’s Case Manager accepted that the
Applicant’s architect’s report and the buildings consultant’s report expressed
the view that there was no link between the 1991 repair work and the 2011
water damage claim.
7. Whilst I accept that the case is unduly complicated by the events of the
intervening years, I am not satisfied that the FSP has established there is no
link between the 1991 repair work and the 2011 water damage claim.
8. I accept that the establishing of that link is critical to the outcome of this
Determination.
9. Both the Applicant’s architect and the FSP’s building consultant clearly
attribute the continued water penetration problem that has been addressed
by the Applicant’s 2012 repair work was caused by problems with the box
gutter on the southern section of “flat” roof. Rain water backup and
blockages caused by leaves and debris from neighbouring eucalyptus were
the cause of water penetration.
10. T he Applicant’s architect stated :
“We do not believe that this problem can ever be resolved while the box
gutters are retained. Indeed we hold the view that when the storm repair was
carried out, particularly with the introduction of metal deck, the box gutters
should have been eliminated.
While it may be possible to strip the roof of all material and lay a new
membrane there would always be doubt in effectively jointing the material in
such a confined and complex area. Such a roof would retain the inherent
danger of box gutters and ongoing damage of the membrane by falling tree
branches.
We consider that the safest and most practical solution is to lay a new metal
deck over the south section of the “flat” roof, eliminating the box gutter
completely. The existing metal deck could be removed, or retained, and be
covered with new “Longline” colorbond decking, fixed in single lengths
between the southern edges/eaves and the junction with the gable roof..
“Longline” can be fixed very effectively at 1 degree pitch, as shown on the
attached drawing (03115-02). This will not affect the ceiling/roof structure and
will only have a minor effect on the external junctions.
While the drawings shows modifications to the eaves of the gable roof to cater
for the single pitch, accurate set-out and careful detailing of the gutter and
flashings may prove that it is not necessary.
It will be necessary to provide a special ridge batten at the top of the 1 degree
pitch and modify the highlight still on the eastern side of the west gable tot
Case No: 285621 Determination Page 8 of 9
provide a new barge flashing for the new metal roof. Neither of these
requirements are difficult to construct and must be done to maintain the
integrity of the system.”
11. Most significantly, the architect concluded:
“There is little doubt that most of the problems stem from the approach taken
for the original repair work, whereby metal deck roofing was fixed over the
damaged membrane without proper regard for correct falls and elimination of
the box gutters. Notwithstanding the problems this has caused over the past
20 years, we believe there is a fairly simple solution that will once again make
the home comfortable and watertight.”
12. I have interpreted the architect’s reference to “original repair work, whereby
metal deck roofing was fixed over the damaged membrane without proper
regard for correct faults and elimination of box gutters......” to refer to the
repair work carried out in 1991. In my view the architect has linked the
continuing problem to that original repair work carried out by the FSP’s
builder more than 20 years ago.
13. As noted by the Applicant that work was carried out under a life time
guarantee under the terms of the policy with the FSP at that time. Thus, I am
satisfied that there is a link between the defects resolved by the recent repair
work which is subject of this claim and the work carried out in 1991.
14. I am reassured in that finding by the comments of the FSP’s building
consultant in his report dated 23 September 2011 a t item 2.4 where he’d
said:
... “the under pitched roof cover is and not the primary cause of rain water
ingress into the bedroom, the box gutter is the culprit. ”
15. Notwithstanding the establishment of the necessary link referred to above it
remains that the Applicant has had the benefit of the roof for more than 20
years. In those circumstances, I believe it is appropriate to apply term of
reference 8.2 in making my determination.
“ Dispute resolution criteria:
Subject to paragraph 8.1, when deciding a Disputer and whether a remedy
should be provided in accordance with paragraph 9, FOS will do what in its
opinion is fair in all the circumstances, having regard to each of the following:
a) Legal principles;
b) Applicable industry codes or guidance as to practice;
c) Good industry practice; and
d) Previous relevant decisions of FOS or a Predecessor Scheme (although
FOS will not be bound by these).”
16. Having considered the matter I believe it is appropriate to apportion the
Applicant’s cost of repairs in the sum of $9,543 .42 on a 60/40 basis in favour
of the Applicant. Thus, the Applicant is entitled to recover the sum of
$5,726.05.
Case No: 285621 Determination Page 9 of 9
Determination
17. The FSP is to pay the Applicant a sum of $5,726.05 in settlement of its
liability under the claim.
18. The FSP is to pay interest on the amount so determined at the statutory rate
from 12 April 2012 until the date of settlement.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.