Home / Financial Firm (Unknown - Insurer) / Determination 282911
Determination 282911
Denial of corrosion damage claim to pleasure craft transom and parts
Summary
The applicant's boat parts corroded rapidly after nearby vessels used a hull protection system, and the FSP denied the claim under its corrosion and electrolysis exclusion. AFCA found the exclusion clear and applicable, and that section 54 of the Insurance Contracts Act did not assist the applicant.
The policy expressly excludes corrosion and electrolysis regardless of cause, and the damage was gradual deterioration within that exclusion.
Issues
- Claim denial primary · not upheld
“the policy contains a clear and specific exclusion in respect of corrosion regardless of how it was caused.”
- Product terms interpretation secondary · not upheld
“You are not covered for any loss or damage caused by or resulting from... corrosion, rust, electrolysis”
Subjects and remedies
no remedy
Text of the determination
Case No: 282911 Determination Page 1 of 5
Case number: 282911
General Insurance - Domestic Insurance - Personal and Domestic Property -
Pleasure Craft - FSP Decision - Denial of Claim
5 February 2013
Background
1. This is a review of a Recommendation by the Service‟s Case Manager dated
29 November 2012. The Applicant has rejected the Recommendation and in
accordance with the Terms of Reference, the matter has been referred to me
for Determination.
2. The relevant background, summaries of the parties‟ position and issue to be
determined as set out in paragraphs 1 to 14 of the Recommendation and I
will restate same.
1. “ The Applicant held a comprehensive private pleasure craft insurance policy
with the Financial Services Provider (FSP) since 20 September 2011 for a
1995 Silverton Cruiser (the boat). The cover provided a sum insured of
$100,000 and has a $500 basic excess.
2. On 17 July 2011 the boat underwent a service, including a full mechanical
inspection, and no problems were found or sighted with the boat. On 17
November 2011 the boat overheated whilst in use and the Applicant
undertook to have the boat inspected to determine the problem.
3. A claim was lodged with the FSP around 30 November 2011 for damage
sustained to the boat due to the failure of parts which had been replaced in
the July 2011 service, through rapid corrosion.
4. The claim was denied by the FSP on the basis of gradual deterioration,
corrosion and electrolysis. The Applicant disputes the FSP‟s denial of his
claim.
Summary of Applicant’s position
5. The Applicant says the boat was moored in a pen at his yacht club in the
vicinity of other boats which were using a type of hull protection. This
protection involved the use of an electronic current and it was this process
that has created an increase in electrical activity in the immediate area.
6. The rapid deterioration of parts which had been replaced as new only 12
weeks prior to the overheating incident is attributable to this hull protection
being used by others.
7. He has taken all reasonable precautions to maintain the boat in an excellent
condition and has done everything possible to discover what he believes is
the cause of the damage.
Determination
Case No: 282911 Determination Page 2 of 5
8. His insurance policy with the FSP covers him for accidental damage and the
damage he has sustained is “accidental” as defined by the Oxford E nglish
Dictionary.
9. He seeks to have his claim accepted and paid in full.
Summary of FSP’s position
10. The FSP acknowledges the cause of the damage as most likely being
caused by the increased electrical activity in the waters surrounding the boat
emanating fr om other vessels and their owners‟ use of a particular type of
hull protection.
11. The insurance policy does not cover loss or damage caused by any gradual
deterioration, corrosion or electrolysis. Electrolysis is specifically excluded
as damage from this cause is highly destructive and can occur in a short
period of time, as evidenced by the damage to the Applicant‟s boat.
12. Whilst it sympathises with the Applicant, the insurance policy offers no cover
for the damage to the Applicant‟s boat in this instance.
13. The FSP relies on the following policy provisions of its Product Disclosure
Statement (PDS):
“ General exclusions
Like most insurance policies, there are general exclusions that
apply to all covers.
You are not covered for any loss or damage caused by or resulting
from, or the costs incurred from or of:
...
wear and tear, mould, gradual deterioration, timber rot,
delamination, vermin, corrosion, rust, electrolysis, osmosis or
marine growth; ”
(Page 21)
Issue
14. Whether the FSP is entitled to deny the Applicant‟s c laim. ”
Reasons for Decision
3. There has been a full exchange of information and each party has had the
opportunity to address the issues that have been raised. I have perused all
of the exchanged material and I have considered the parties‟ submissions
including the Applicant‟s further submission dated 10 January 2013.
4. In making her Recommendation, the Service‟s Case Manager set out her
reasons in paragraphs 17 to 31 and I will restate same:
Case No: 282911 Determination Page 3 of 5
17. The Applicant has invested a great deal of time and money in investigating
the cause of the rapid deterioration of parts he had replaced as new in July
2011. It is his belief that the damage is accidental.
18. Through the investigations he undertook, it was discovered that other boat
users in the vicinity of where his boat was moored were using a relatively
new (for the area) hull protection product. It is this product which the
Applicant believes has created parts of his boat to corrode within a 12 week
period.
19. The FSP‟s appointed assessor noted the damage to the boat as being so
severe that had the Applicant postponed any maintenance work, the boat
was in danger of sinking. He likened the extent of corrosion to that he would
expect to see from a boat that had been left in a poorly maintained condition
for a number of years.
20. The Applicant provided a detailed maintenance history of the boat and it is
apparent the damage being claimed by him is not because of a lack of
maintenance.
21. The FSP‟s appointed assessor was present during tests of the waters
surrounding where the boat was moored. These tests had been arranged by
the Applicant. The purpose of the tests was to measure the extent of
electrical activity in the water.
22. The results of those tests found that when the hull protection being utilised
by a boat east of the Applicant‟s boat was “off”, the reading was
approximately 600 milliamps. When the hull protection was “on”, the reading
was approximately 1000 milliamps. These tests supported the Applicant‟s
belief that the hull protection being used was increasing the electrical activity
in the surrounding waters of the boat and thus increasing the rate at which
items could corrode.
23. The FSP‟s assessor offered an explanation to how this hull protection could
cause rapid corrosion in his report, which says:
“... the [hull protection] system utilises a DC current which runs between
the system‟s two copper electrodes. This DC current results in the
creation of a copper ion field which disperses in the water around and
between the electrodes. As copper is a fungicide this discourages
bacterial and other growth from f orming on the vessel‟s hull.
We advise that in optimal conditions the CD current would run between
both electrodes and cause the depletion of the copper electrodes only.
However, the unit deploys a DC voltage into the water and therefore has
a very high po tential current to „stray‟ to an alternative earth. Should this
be the case, electrolytic corrosion would likely occur. Electrolytic
corrosion is a particularly aggressive and rapid form of corrosion with the
potential to cause dramatically increased rates of corrosion damage when
compared to corrosion via salt water alone. Electrolytic corrosion occurs
when stray DC current is in the presence of dissimilar metals e.g. vessel‟s
aluminium legs and is immersed in an electrolyte (salt water).”
24. I am of the opinion, based on the information supplied by both the Applicant
and the FSP, that the damage is most likely attributable to the use of this
hull protection by others, near to where the Applicant had the boat moored.
25. The FSP‟s PDS says:
“ What you are insured a gainst
Case No: 282911 Determination Page 4 of 5
Your [FSP] insurance covers your boat for loss or damage caused by any
of the following Insured Events.
Insured Event – You are covered
for:
Our Exclusions – You are not covered for the
following:
( see also General Exclusions on pages 21 - 22)
Accidental Loss or Damage
We will cover you or anyone you
entrust to use your boat for accidental
loss or damage to your boat and
contents. This includes damage
caused by fire, storm, impact, sinking
and any other event not specifically
excluded by the policy.
Loss or damage to an outboard motor when secured
to a boat or boat tender in a manner other than that
specified or recommended by the manufacturer of
the motor, boat or boat tender;
Loss or damage specifically excluded under the
other Insured Events listed in the policy.”
26. There is no time limit on this insured risk – that is, accidental loss is not
limited by one singular incident. Clearly the damage to the Applicant‟s boat
has occurred over a period of time, albeit a short period of time and would
not have been from one singular “turning on” of the hull protection of nearby
boats. I am of the opinion that a singular event would not have caused the
extent of damage described by the FSP‟s assessor.
27. I am satisfied that the damage would fall under the scope of this insured risk,
and as such, the Applicant has discharged the onus of proof he has to prove
he has suffered a loss which is covered by an insured risk.
Policy Exclusions
28. The responsibility now shifts to the FSP to prove that an exclusion applies to
the claim lodged by the Applicant.
29. It should be noted that the FSP has not attempted to suggest to the
Applicant that he has in any way contributed to the damage to the boat or
that the damage is as a result of a lack of maintenance. It has suggested the
damage is a “gradual deterioration” and I agree with this statement, again,
albeit if the graduation was only over a 12 week period.
30. The FSP says if it accepts that the damage has been caused as detailed
above, the damage to the boat is as a result of corrosion caused by
electrolysis. I am satisfied that this is how the damage to the Applicant‟s
boat has occurred.
31. I am of the opinion that the relevant exclusion is clear and unambiguous in
this regard:
“ You are not covered for any loss or damage caused by or
resulting from, or the costs incurred from or of :
...
wear and tear, mould, gradual deterioration, timber rot,
delamination, vermin, corrosion, rust, electrolysis, osmosis or
marine growth;”
(my own emphasis added) ”
Case No: 282911 Determination Page 5 of 5
5. The question at issue is whether the FSP is entitled to deny the claim on the
basis of the exclusion that is set out in paragraph 13 of the Recommendation
as stated above.
6. The FSP has relied upon an expert report from its surveyor/engineer who
inspected the vehicle and made a close examination of the damage to the
vessel‟s transom assemblies. He stated that the damage which he observed
was consistent with very aggressive corrosion. Following further
investigation, the expert expressed the opinion that the aggressive rate of
corrosion was consistent with electrolytic corrosion that can occur when
stray DC current is present. He further noted that another vessel or vessels
nearby deployed an anti-failing system that may have caused the electrolytic
corrosion. The expert recommended the instal lation of a “DC current blocker”
to negate the corrosive effect. As noted in his final submission, the Applicant
states that he has employed an electrolysis blocker and, if so, I am unable to
ascertain how the corrosion was caused.
7. One possible explanation is that the blocker used by the Applicant was
ineffectual in preventing the damage suffered.
8. I have given consideration to whether Section 54 of the Insurance Contracts
Act (1984) could assist the Applicant but I am satisfied that it does not apply
in this instance.
9. The problem facing the Applicant is that notwithstanding what caused the
corrosion, the policy contains a clear and specific exclusion in respect of
corrosion regardless of how it was caused.
10. Whilst I am sympathetic with the Applicant in his predicament, the terms of
the policy must be observed and I agree with the Service‟s Case Manager‟s
Recommendation
Determination
11. The FSP is entitled to deny the Applicant‟s claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.