Home / Financial Firm (Unknown - Insurer) / Determination 280177

Determination 280177

Claim denial - rainwater seepage, faulty workmanship and wear exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2013-02-08
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded$2,700
Non-financial loss—
Amount claimed$48,500
SourceAFCA PDF

Summary

Water seepage damaged the applicants' home slab and external walls, and the FSP denied most of the claim under policy exclusions. AFCA ordered the render repair to one metre above the foundation and $2,700 for footings, with s57 interest.

Once a prima facie accidental loss is shown the insurer must prove an exclusion, and only the footing repairs, not the works rectifying seepage, fall within cover.

Issues

Subjects and remedies

home or building damagepay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 280177 Determination Page 1 of 10 Case number: 280177 General Insurance – Domestic Insurance – Home Building Insurance – Stormwater damage – Extent of cover – S57 Insurance Contracts Act 1984 22 January 2013 Background 1. The Applicants insured their home building under a Home Building Insurance Policy against accidental loss or damage for $262,500 with a $300 policy excess. The house was built in about 2005 and reported by a loss assessor to having been maintained in good condition. 2. On 3 March 2012, the Applicants reported that the concrete slab of their house had been inundated with moisture which spread through the house damaging carpets and the external rendering of the house. 3. The Applicants submitted a claim for:  Damage to the carpets;  Repairs and re-rendering the external walls at a cost of $26,000; and  Repairs to the concrete slab at a cost of $22,500. 4. The Financial Services Provider (FSP) accepted the claim for the damage to the carpets and offered to cash settle the claim for repairs to the external walls for the amount of $2,090 which was rejected by the Applicants. 5. The FSP denied liability for the cost of repairs to the concrete slab on the ground that the policy excludes loss or damage caused by rainwater seeping, percolating or otherwise penetrating into the insured premises. 6. The Applicants dispute the FSP’s decision and contend the damage caused to their house is covered under the terms of their policy. Summary of Applicants ’ Position 7. On or about 2 March 2012, a flooring contractor visited their home to install timber flooring over the concrete slab. When the contractor began to remove the carpet he found moisture in the floor of two rear bedrooms. There was Determination Case No: 280177 Determination Page 2 of 10 water staining along the walls which was assumed to have been caused by watering large pot plants situated along the exterior of the walls. 8. On 3 March 2012, the contractor proceeded to remove carpet from three front rooms and found the same dampness problem. Realising there was a dampness problem throughout their house he would not proceed with the installation of the timber flooring until the dampness problem was rectified. 9. The Applicants submitted a claim on the FSP for the damage caused by water seeping through the slab of the house from all sides. The FSP denied their claim. 10. A plumbing test was carried out which confirmed that water was not escaping from any downpipes or sewerage pipes. 11. On or about 11 May 2012, the FSP informed the Applicants that it would accept the claim for the damage to the carpets and repair a crack in a wall. The Applicants informed the FSP that there were cracks in the render in all of the exterior walls around the house. 12. The FSP rejected their claim for the cost of rendering their house but accepted the claim for repairing a crack in one of the walls and offered a cash settlement of $2,090. They rejected the offer based on the fact that water had damaged and caused cracking to all exterior walls. 13. They engaged a building services company, ‘JH’, who had carrie d out a pre- purchase inspection of their house, to carry out another inspection. JH confirmed that the crocodile cracks were new and had appeared in the lower section of the walls due to water penetration and that the cracks were not present at the time of the pre-purchase inspection. 14. The Applicants contend that the FSP should accept their claim for repairs to the walls because the cracking was caused by rainwater seeping into the concrete slab. The cost of repairs to the walls is $22,500. 15. Further, the Applicants submit that the rainwater that had been entering the concrete slab had to be stopped. A waterproofing contractor, ‘MP’, dug trenches on three sides of the house and found cracks in the concrete slab where water was entering. MP ensured that the cracks in the slab were sealed and that water cannot enter the slab any more. The cost of repairs was $26,000. 16. The Applicants contend that the FSP should pay their claim because the loss or damage was accidental. The Applicants were also not aware of the water seepage problem until March 2012. 17. The FSP has offered to have only one minor pre-existing crack repaired rather than having the water caused cracks repaired, even though, by accepting the damage to the carpets, it accepted that water entering the building caused the entire problem. Case No: 280177 Determination Page 3 of 10 18. The water caused cracks are almost entirely around the house approximately one metre from the ground whereas the pre-existing cracks are minor of a few centre metres each. 19. The FSP contends that there is clear evidence of insufficient drainage. The Applicants submit that if they were aware of this problem they would not have purchased the house in the first instance. 20. The Applicants submit that the FSP should pay for:  the repair work they paid for in sealing the footings which were cracked due to rainwater seeping, the cost of repairs was $22,500;  the cost of repairing the cracks that have appeared in the render of the external walls where rainwater has been seeping, the cost of repairs is $26,000. The crocodile cracking around the house needs to be repaired and the render restored to its original pre -condition damage. Summary of FSP’s Position 21. In response to the Applicants’ claim, the FSP arranged for an assessing firm to inspect and report on the cause of the moisture and to provide additional information on the excessive water flow from the neighbouring property. The assessor appointed an engineer and a qualified plumber to address these issues. 22. A structural engineer, ‘RH’, confirmed the moisture affecting the Applicants’ house was coming from the neighbouring property and that there was no drainage around the house which allowed water to seep under the concrete slab. The plumber, ‘LT’, also checked and clarified that the Applicants’ house pipes were not leaking. 23. The FSP confirms that as a result of the ongoing drainage issues, the Applicants have since undertaken extensive landscaping work to divert the flow of water and waterproof the slab to try and stop the problem occurring in the future. 24. The policy of insurance covers accidental loss or damage but excludes storm, rainwater or run-off entering the house caused by:  ‘rainwater seeping, percolating or otherwise penetrating into the Residence as a result of structural defects or faulty design or faulty workmanship in the Residence. This does not apply if You were unaware of and a reasonable person in the circumstances could not be expected to have been aware of the defect, faulty design or faulty work or workmanship;’ 25. During the FSP’s review, the Applicants satisfied it th at they were unaware of the problem and it was not until the carpets were removed that they became aware of the issue. In response the FSP agreed to pay for the cost of the carpets to be replaced. Case No: 280177 Determination Page 4 of 10 External Rendered Walls 26. In respect to the damage to the external rendered walls, the FSP, as a gesture of goodwill, despite the initial original building inspection confirming pre-existing render cracks, agreed to reimburse the Applicants for the cost of repairs for the amount of $2,090. 27. The Applicants declined this offer as the render damage continued to spread and they had obtained a quote for the amount of $26,000 for a complete re- render. 28. The Applicants’ builder inspector reported:  new cracking was confirmed to all elevations up to approximately one metre in height due to water penetration through the masonry wall line;  a moisture reading on all areas adjacent to the new cracking has recorded a positive result for high moisture;  the cause of the high readings is due to water leaks, penetration from both seepage and absorption through new cracking in the external masonry walls. 29. The FSP appointed structural engineer reported on 27 June 2012:  the external walls have very little areas of defects that would warrant the complete removal of the render and reinstatement;  expansion joints in the building, particularly in the south/west corner, are experiencing minor ground movement due to climatic conditions of water moisture content within the soil, such that the joint has a separation of the sealant material approximately a class 1 separation crack (minor);  it is evident that the render showing the spider web cracking is due to the fact the render has been installed possibly by spray and the material used contains a degree of saline salt that affects the cementatious product within the applied material;  this type of rendered wall should be sealed against moisture inclusion. This factor has not occurred in the Applicants’ walls and it is a requirement for good practice for protection of the surface. 30. The FSP contends:  there is confirmed pre-existing cracking/delamination to the home;  there is additional work such as brick mortar gaps that was required to be attended to;  there is no need for the complete removal and reinstatement of the render; Case No: 280177 Determination Page 5 of 10  there is confirmed pre-existing evidence of ground movement due to climatic change and moisture;  there is evidence that the ‘Gold Coast Sand’ may have been insufficient;  the applicants have confirmed by phone that the crack it had agreed to pay for was evident prior to purchasing the home; and  there is clear evidence of insufficient drainage. 31. The FSP has relied upon the following policy exclusions to deny liability:  Faulty workmanship including any inherent defect, defective design or manufacture – this applied to the insufficient drainage and insufficient quality of sand;  Lack of maintenance – this applies to the repair of the pre-existing cracking and maintenance of the exterior of the home;  Wear and tear, depreciation, corrosion or mildew – the current render is in excess of 7 years old and require attention. 32. Therefore, indemnity was declined on the basis of the above exclusions but as a gesture of goodwill, the FSP will continue to offer the Applicants the amount of $2,090. Repairs to Concrete Footings 33. The Applicants also submitted a claim for the FSP to pay the amount of $22,500 for sealing the footings which were cracked due to rainwater seeping. 34. The Scope of Works (SOW) for the entire project included extensive landscaping work to divert the flow of water and waterproof the slab to address the water ingress problem. The contractor has confirmed that main SOW was to waterproof the concrete slab which is the major component costing $18,500. 35. The FSP submits that this additional work is not covered under the terms and conditions of the policy. 36. The policy of insurance limits the amount of cover to rebuild the insured property or repair the damage portion to a condition that is the same as before it was damaged but no better nor more extensive than its condition when new. 37. The FSP relies on the following policy/contract provisions: ‘4. Home Building – Accidental Loss or Damage Cover 4.1 Our commitment We will cover You for Accidental Loss or Damage to Your Home Building as defined in 4.2, unless it is excluded elsewhere in The Policy. The Accidental Loss or Damage must happen during the Period of Cover and at the address shown in the Schedule. ... Case No: 280177 Determination Page 6 of 10 6. What is not covered by The Policy We will not cover You or Your Family for Loss or Damage nor will We cover You or Your Family for any claim against You or Your Family arising from: ... 6.10 Faulty workmanship faulty workmanship including any inherent defect, defective design or manufacture. ... 6.15 Lack of maintenance lack of maintenance that could reasonably be expected to protect the Residence, Your Home Contents and Your Personal Property. ... 6.25 Storm, Rainwater, Run-off and Flood entering Your Residence Storm, Rainwater, Run-off and Flood entering Your Residence caused by:  rainwater seeping, percolating or otherwise penetrating into the Residence as a result of structural defects or faulty design or faulty workmanship in the Residence. This does not apply if You were unaware of and a reasonable person in the circumstances could not be expected to have been aware of the defect, faulty design or faulty work or workmanship;  ...’ 6.34 Wear and tear Depreciation, we ar, tear rust, deterioration, corrosion or mildew.’ Issues 38. Whether the FSP can rely on the policy exclusions relied upon to deny liability for the Applicants’ claim. Reasons for Decision 39. Due to the nature of the dispute, the FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. Thus, this dispute has not been subject to a FOS Recommendation and has proceeded directly to Determination. The parties have been previously advised that a Determination will be issued in this case. 40. The onus of proof is on the Applicants to establish, on the balance of probabilities, that they have suffered a loss caused by a risk insured against. Once the Applicants have established that the loss was prima facie caused by a risk insured against, the onus shifts to the FSP to show, on the balance of probabilities, that the loss falls within an exclusion in the contract of insurance. 41. There has been an exchange of material which the parties rely on. Each party has had access to the material on which the other party bases its case. As a Case No: 280177 Determination Page 7 of 10 consequence it is not necessary to go into all of this material other than when relevant. 42. The Applicants’ policy of insurance insures their home building against accidental loss or damage. Their home was damaged by water inundation, therefore, prima facie, they have a claim that falls within the policy cover. 43. Accordingly, the onus shifts to the FSP to establish that, on the balance of probabilities, the damage to the Applicants home was caused by an exclusion under the policy. External Rendered Walls 44. In or about early 2012, the Applicants noticed moisture and mould build-up within sections of their home. The Applicants engaged a water leak contractor to investigate the cause of water ingress. The contractor, ‘LT’, reported on 6 March 2012: ‘Several rooms showing signs of dampness in floor slab mainly in around external walls and efforesence is apparent on slab up to about 300-400 mm in from walls. The ground all around the house was very wet and the block is cut with retaining walls on two sides. Extensive hairline cracking in render on the lower sections of all walls.’ 45. Before the Applicants purchased the insured property in 2010 they engaged a building consultant, JH, to carry out a pre-purchase inspection. JH reported on 13 March 2010 that the brickwork/masonry was good to fair and there was ‘cracking – delamination to render’. 46. On 7 June 2012, JH carried out a follow up inspection of the property. In his report dated 13 June 2012, JH stated, in part:  his original report noted three areas of stress cracks to masonry rendered walls; Additional Problems  evidence of new cracking to wall areas, generally to nearly all wall elevation areas from foundation line up to approx. 1.0 metre in height including discolouration of wall finishes;  the form of cracking and discolouration is normally due to water penetration through masonry wall line;  moisture meter readings recorded positive high moisture readings;  the cause of the high readings is due to water leak penetration from both seepage and absorption;  the house flooring also recorded positive high moisture readings. 47. The FSP’s loss assessor reported on 24 May 2012: Case No: 280177 Determination Page 8 of 10  The adjacent property downhill from the Applicants recently had rectification works carried out by the QBSA under the building warranty. A natural spring had been found to be causing seepage into the floor slab of the building;  Extensive drainage works were carried out;  Confirmation of a spring on site also involved an inspection of the wall cavities of the Applicants’ home which revealed water ponding in the wall cavity under the damp proof course (DPC) line;  Water entering the wall cavity would be through seepage up through the slab;  There was also spider web cracks across the lower sections of the walls;  The loss assessor researched the cause of the damage to the rendered walls and noted that spider web cracks is the result of thermal movement and/or shrinkage of the cement render against the inner brick wall;  Given the high moisture content of the brick skin caused by rising damp in the walls this would exacerbate the expansion of the two materials as the render heats up and cools down at differing rates to the internal brick wall;  It was the loss assessor’s and engineer’s opinion that the cracking to the external wall render is a direct result of rising damp caused by seepage from water flowing under the floor slab from natural springs. 48. I find that this is accidental loss or damage and falls within the cover provided by the policy. 49. One of the grounds relied upon by the FSP is denying indemnity to the Applicants relates to rainwater seeping, percolating or otherwise penetrating into the residence as a result of structural defects or faulty design or faulty workmanship in the residence. 50. The FSP has not submitted any evidence that, on the balance of probabilities, the Applicants’ house suffered faulty defects, faulty design or faulty workmanship. 51. The exclusion relied upon by the FSP also provides that the exclusion does not apply if the Applicants were unaware of and a reasonable person in the circumstances could not be expected to have been aware of the defect, faulty design or faulty work or workmanship. 52. The FSP accepted the claim for damage to the carpets caused by the water seeping through the concrete slab because it accepted the Applicants were unaware of the water seeping into their home. Case No: 280177 Determination Page 9 of 10 53. I find that this decision by the FSP also applies to the damage to the external render of the house. 54. The building inspection report of 13 March 2010 stated that there was cracking and delamination to areas of the rendering. The building inspector, JH confirmed in June 2012 that there were minor cracks in three areas of the masonry rendered walls. 55. Further, JH confirmed that the evidence of new cracking was generally nearly to all wall elevation areas from the foundation line up to approximately 1.0 metre in height including discolouration of wall finishes. 56. The Applicants have submitted a claim of $26,000 for the re-rendering of all the ext ernal walls. I note that the FSP’s engineer reported that complete removal of the render and reinstatement is not warranted. Further, building inspector JH reported that the damage to the rendered walls was limited to one metre above the foundation line. 57. Therefore, I find that the FSP liability for the damaged to the rendered wall from water seepage is limited to removing, replacing and repainting the render, as per the quotation provided to the Applicants from AW, to one metre from the foundation line. 58. The FSP has also relied upon the policy exclusions in respect to:  Lack of maintenance;  Wear and tear to deny indemnity to the Applicants. 59. The FSP has not submitted any evidence to support reliance of these policy exclusions. Repairs to concrete footings 60. The Applicants have submitted a claim for $22,500, including GST, to carry out works to prevent further water damage to their home. However, the quotation includes works pertaining to: (i) repairing horizontal cracks in the footings on three sides of the house; (ii) construction of drainage trenches and piping, and plumbing works; (iii) water proofing the concrete slab; and (iv) landscaping. 61. The Applicants policy of insurance covers accidental loss or damage. Therefore, the only work that falls within the policy cover is item (i). Case No: 280177 Determination Page 10 of 10 62. Items (ii), (iii), and (iv) are works to rectify the water seepage problem and do not fall within the terms and conditions of the policy. 63. The contractor, MP, has informed the FSP that the total cost to complete works (ii), (iii), and (iv) was $19,800 including GST. Therefore, the cost of repairing the cracked footings was $2,700. Determination 64. Accordingly, I determine that:  the FSP is to indemnify the Applicants for the cost of repairing, re- rendering and re-painting the external walls to a height of one metre above the foundation line, and  to pay the Applicants the amount of $2,700 for the cost of repairing the damaged footings. 65. Further, I determine the FSP is liable to pay interest under section 57 of the Insurance Contracts Act 1984 at the rate prescribed in the Insurance Contracts Act Regulations for the period from 16 July 2012, the date of the FSP’s IDR decision letter, to the date of settlement of this determination. 66. For the assistance of the parties, the prescribed interest rate appropriate to this determination is 6.0%.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.