Home / Financial Firm (Unknown - Insurer) / Determination 278037

Determination 278037

Denial of storm-related building damage claim for rental property

FirmFinancial Firm (Unknown - Insurer)
Decided2013-06-04
ProductGeneral Insurance · Landlord
OutcomeFor the complainant in part
Amount awarded$38,025
Non-financial loss—
Amount claimed$46,190
SourceAFCA PDF

Summary

Landlords claimed storm-related cracking damage to a rental house after the insurer denied the claim. AFCA found the denial unjustified, apportioned 70% of the repair cost and loss of rent to the insurer, and ordered $3,000 for loss of sale value plus interest.

The storm-driven water inundation was the proximate cause of the soil movement and cracking, so the soil movement and tree exclusions did not defeat the claim, subject to apportionment for other contributing factors.

Issues

Subjects and remedies

home or building damagepay claimpay compensationpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 278037 Determination Page 1 of 22 Case number: 278037 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim 28 May 2013 Background 1. The Applicants held a landlords insurance policy with the Financial Services Provider (FSP) from 31 March 2006 and the policy was current at the time of damage. The policy provided landlord tenant protection for the building for its current replacement value and loss of rent, subject to terms and conditions of its Product Disclosure Statement (PDS). 2. The Applicants contacted the FSP between 12 January 2010 and 14 January 2010 to advise that severe cracking had occurred to the walls of the property. The Applicants did not provide a cause of damage at this time and was investigating same with local council due to an apparent collapse of a drain in a laneway next to the insured property. 3. The FSP appointed experts to attend and inspect the property to confirm the cause and extent of damage. The Applicants also sought an expert opinion. The FSP denied the Applic ants‟ claim for several reasons including the Applicants failure to prove that the damage had been caused by an insured event, pre-existing cracking to the building, the actions of trees, wear and tear, soil movement and subsidence. 4. The Applicants dispute the denial of the claim on the basis that the proximate cause of the damage was storm water run-off. The Applicants were also dissatisfied that the FSP failed to respond to telephone and written requests to action the claim. Summary of Applicants’ position 5. The Applicants are represented. For the sake of clarity and brevity, the Panel will refer hereafter to the Applicants and their representative as “the Applicants”. 6. The Applicants contacted the FSP immediately they became aware of a problem at their property, which was when they received advice from their tenants that there was severe cracking to the property. Determination Case No: 278037 Determination Page 2 of 22 7. When reporting the loss, they were not aware of the cause of the damage, however suspected the damage may be attributable to recent heavy rain storms and possibly the failure of nearby water mains. 8. They arranged for relevant water authorities and local council to inspect drains etc in the area to see if any of these contributed to the damage. 9. A quotation for repairs was obtained for an amount of $36,190. This quotation did not include additional cracking to the south wall of the property and a quotation was not obtained. The Applicants estimate the costs to repair this wall to be in the vicinity of $10,000. 10. The property could not be tenanted during the claims process due to the extent of damage and as such, the property remained untenanted until 1 August 2011. The tenants vacated the property at the request of the FSP‟s assessor. 11. Whilst there were some minor cracks to the property which they had repaired over the years, the cracks which appeared at the beginning of 2010 were much larger and had not been present before. 12. Trees which had been removed from the property, on the advice of the FSP‟s assessor, were not large ; in fact one tree near where the majority of damage to the building has occurred was only a sapling. 13. The Applicants seek to have their claim accepted and payment made of the cost of repairs as estimated ($46,190) plus two years loss of rent. In the alternative, as the Applicants have since so ld the property, they seek the difference between the received sale amount and the expected sale amount, had the property been in a sound condition/repaired, plus the loss of rent claim. Summary of FSP’s position 14. The FSP says the Applicants reported the claim on 14 January 2010 advising that there appeared to be severe cracking to walls at the property. At this time the Applicants indicated the damage may be relevant to local storm water or sewer drains and the Applicants were to investigate further with the local council. 15. It appointed experts, including an assessor, to inspect and report on the cause and extent of damage. Based on the information provided by its experts it denied the Applicants‟ claim on the grounds that the footings of the house were inadequate and the existence of trees near the house had contributed to the damage noticed. 16. Further investigations as to the cause of the damage were undertaken by the FSP via its experts, on receipt of the Applicants‟ dispute regarding the denial of their claim. This further investigation resulted in a number of causes being identified as having contributed to the damage. One of these causes was Case No: 278037 Determination Page 3 of 22 identified as being defects in the hydraulic services located at the rear extension area of the southern end of the Applicants‟ house which resulted in some minor damage to the bathroom and laundry area. 17. It maintained its denial of the claim for the majority of items, however did offer a settlement for the damage to the bathroom and laundry area for an amount of $3,964.38. 18. The Applicants submitted their own expert report dated 25 July 2011 which was received by the FSP on 13 November 2011. The report was considered, however the decision to deny the Applicants‟ claim was upheld. 19. The FSP relies on the following policy provisions of its Product Disclosure Statement (PDS): “ What we cover – insured events This section describes under the headings: Yes – the insured events you are covered for, No – the conditions and exclusions that specifically apply to particular insured events. Yes No You are covered for damage or loss occurring during the period of cover and caused by the following events to: when your landlord building is insured, to that landlord building, ... You are not covered for: ... ... Storm and rainwater including stormwater runoff from areas surrounding the site, or water escaping from any water main, drain, pipe, street gutter, guttering or surface. Storm means violent wind (including a cyclone or tornado), thunderstorm or a heavy fall of rain, snow or hail. The cost of cleaning or clearing debris from any pool or spa. Damage or loss caused by water seeping into or otherwise entering your landlord building due to: a defect or fault in the design, structure or construction of your landlord building where you could reasonably be expected to be aware of the defect or fault, building alterations, renovations or additions. Damage or loss caused by dust where your landlord building has not been otherwise damaged by storm.” (Pages 12 to 17) “ What we do not cover – general exclusions Case No: 278037 Determination Page 4 of 22 You are not covered under any section of the policy for damage, loss, cost or liability caused by or arising from or involving: an unreasonable failure to properly maintain or repair your insured property, wear and tear, rust, deterioration or corrosion, ... soil movement or settlement, subsidence or landslide unless caused by the insured event of earthquake, ... The actions of trees, plants or their roots,” (Page 18) “ We pay for loss of rent We will pay for the loss of rent incurred by you while your landlord building is being rebuilt or repaired if: your landlord building has been damaged or lost by an insured event, and we agree your landlord building is no longer habitable, and your tenant was paying rent due under a current rental agreement with you for at least four consecutive weeks preceding the date the damage or loss occurred. ... Our payment will be actual loss of rent incurred by you during the reasonable period up to 12 months required to repair or rebuild your landlord building or to restore access to your landlord building and it is otherwise habitable.” (Pages 28 to 29) Issues 20. Whether the FSP is entitled to deny the Applicants‟ building damage claim other than the part it has settled. 21. Whe ther the FSP is entitled to deny the Applicants‟ loss of rent claim in its entirety. 22. Whether the Applicants are entitled to compensation. Reasons for decision 23. As advised to the parties, FOS has considered it appropriate to refer this dispute directly to a Panel in accordance with the Operational Guidelines to the FOS Terms of Reference. This dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination. Case No: 278037 Determination Page 5 of 22 24. This decision has been made by a Panel consisting of an Ombudsman and two Panel members with extensive experience in insurance industry matters and consumer claims. 25. The Panel is satisfied there has been a full exchange of material between the parties and that each party has had the opportunity of clarifying the issues that arise from the material. Property 26. The insured property is a residential dwelling comprising a single storey solid brick, iron roofed construction supported on concrete strip footings. The property is of the Victorian period. The property‟s frontal aspec t faces roughly east. There is a right of way (laneway) to the southern aspect of the property. 27. It is agreed by all parties, that the predominant damage the subject of this claim, is to the centre of the southern side of the dwelling. 28. It is also agreed by the parties that there was some pre-existing cracking to the property which had previously been repaired. The Applicants say this cracking was minor compared to the cracks seen in February 2010. 29. The Applicants owned the property for approximately 17 years prior to the lodgement of the claim and had rented out the property for a period of time. The property was tenanted at the time of the appearance of the large cracks, the subject of the Applicants‟ claim. The claim 30. The FSP says that when the Applicants reported the damage to their property, no cause was identified. File notes indicate the Applicants ‟ advice was: “IO WAS CONT ACTED BY THE AGENTS THAT THERE APPEARS TO BE SEVERE CRACKING OF BRICK WALLS ON THE PROPERTIES EXTERIOR WALLALONG ONE SIDE IO HAS INSPECTED THE BUILDING AND HAS NOTICED IN A LANEWAY NEXT TO THE BUILDING THE STORM WATER OR SEWER DRAIN APPEARS TO BE COLLAPSING AS HE HAS NOTICED BLUESTONE PAVERS IN LANE HAVE MOVED APPROX 300MM FROM THE MAN HOLE COVER AND THIS MAY HAVE SOMETHING TO DO WITH THE PROBLEM OF HIS BRICK WALLS CRACKING IO IS CONTACTING LOCAL COUNCIL TO ARRANGE INSPECTION.” (sic) 31. The FSP says the Applicants were advised that the claim was under consideration until such time a cause of the damage could be identified and that it would assist in this regard by appointing an assessor. 32. The FSP arranged for the assessor CS to inspect the property to determine the cause and extent of damage. CS attended the property on 10 February 2010. CS provided the following summary of his findings: Case No: 278037 Determination Page 6 of 22 “OB SERVATIONS. PERIOD SOLID BRICK HOUSE. SOIL IN THIS AREA WOULD BE H- HIGHLY REACTIVE. EXTENSIVE CRACKING AND SUBSIDENCE TO THE RIGHT SIDE OF THE HOUSE. EVIDANCE OF EXTENSIVE PREVIOUS FILLING OF SOME OF THE SAME CRACKS AND EASING OF DOORS & WINDOWS. TREES ON SITE - YES. 1 MATURE TREE GROWING WITHIN 600MM OF THE BACK LEFT CORNER OF BEDROOM 2 WHERE MUCH OF THE CRACKING HAS OCCURED. 2X LARGE TREES WITHIN 3-4M OF THE BACK LEFT CORNER OF THE HOUSE. DOWN PIPES DISCHARGE ONTO THE COBBLE STONES OF THE SIDE LANEWAY. SEWER PIPES ARE AT THE BACK LEFT OF THE HOUSE AND ARE IN EARTHENWARE.” [sic] 33. Upon CS ‟s advice, the FSP then appointed a geotechnical expert, SG, to attend to conduct an inspection and soil testing. SG‟s report contained the following comment on the findings: “ 7.0 COMMENT The laboratory derived soil moisture contents of the silty clay show some variation between boreholes, with borehole 1 being considerably higher than borehole 2. Borehole 1 which was conducted adjacent to the central southern wall of the dwelling is considered to have a slightly higher than normal soil moisture content. Borehole 2 which was conducted as a control adjacent to the front of the dwelling had a soil moisture content that was within a normal range. The relatively poor site drainage and earthenware pipes may be a factor in the elevated soil moisture contents. The concrete strip footings supporting the dwelling have a founding depth of 400mm and depth of concrete of 200mm, which is considerably less than the minimum 1000mm founding depth and 600mm depth of concrete as stipulated by Australian Standards. These footings would lack rigidity and unable to properly withstand volumetric shrinking and swelling of the highly reactive high plasticity silty clay as soil moisture contents fluctuate. The excessive soil moisture contents encountered in borehole 1 would have resulted in relative swelling of these clays. It is possible that there is a sewer / drainage easement in the adjoining laneway which is undermining the undersized footings.” 34. The FSP reviewed SG‟s report on 11 March 2010 and informed the Applicants that the claim was not one for acceptance. The file note of this date says: “11 MARCH 2010 SOIL REPORT REVIEWED. CLAIM DECISION IS NOT FOR ACCEPTANCE. Case No: 278037 Determination Page 7 of 22 REASON FOR CLAIM DECISION: 1. UNDER SIZED FOOTINGS NOT ABLE TO WITHSTAND SOIL MOVEMENT ON THIS HIGHLY REACTIVE CLAY SITE. 2. DRAINAGE ISSUES ON SITE AFFECTING SOIL CONDITIONS. 3. TREES IN CLOSE PROXIMITY TO HOUSE AFFECTING SOIL CONDITIONS. 4. EVIDANCE OF PREVIOUS CRACKING AND REPAIRS BY MR IO TO WALLS, DOORS AND WINDOWS. MR IO HAS BEEN ADVISED OF THE CLAIM DECISION AND APPEAL PROCESS.” [sic] 35. The Applicants requested a formal denial letter from the FSP on at least two separate occasions in June 2010 and a denial letter was sent by the FSP on 15 June 2010. The letter detailed the findings of CS and SG and provided the following reason for denying the Applicants ‟ claim: “After a thorough review of all the information regarding your claim, [the FSP] is satisfied that at this stage you have not been able to substantiate that the damage to the building has been caused by an insured event. Further [the FSP] has undertaken all reasonable endeavors to assist with determining the cause of the damages, and at this stage have not been able to confirm that the damages are as a result of an insured event. As a result, you have not substantiated that you are covered for this damage under any section of the policy. We note that a report from [local water authority] has been requested; we advise that should this report be provided then we will be in a position to give further consideration to your claim.” [sic] 36. On receipt of the formal denial letter, the Applicants provided advice to the FSP in July 2010 that they had spoken with the local water authority, YV, who had suggested that there had been storm water run-off from a sewer pit. A report from YV was still awaited at that time. The Applicants requested the FSP reconsider its decision on their claim based on this information. 37. The FSP agreed to further investigate the claim and appointed AL to conduct leak detection tests at the property to verify the information provided by the Applicants. These tests were conducted on 6 August 2010. AL advised: “ RESULTS AND FINDINGS AT THE TIME OF TEST: The property has 3 down pipes. Two discharge to a laneway and the other to the rear south side runs about 1 meter then it is either blocked or does not go anywhere (capped off) it is made from Vic Clay. The sewer line is also made of Vic clay and has a major dropage just before the inspection point, approx. 500mm back to the insured sewer line. The sewer shaft also has another connection point that runs under the slab of the insured bathroom/laundry and fees up to 3 to 4 other houses heading north. On this line there are cracks at 6.5m from the boundary inspection point (shaft) of the insured and other racks and small misalignments. Domestic water tested up ok at time of tests.” [sic] 38. At some point after receiving the AL report, the FSP decided to appoint a forensic/structural e ngineer, FM to also inspect and report on the Applicants‟ Case No: 278037 Determination Page 8 of 22 property. FM attended the property on 12 October 2010 and provided the following summary of his findings: “ 8.0 Discussion The distress to this house falls within the moderate to severe categories 3 and 4 in accordance with AS2870. The damage to this house is not recent, and has most likely been occurring for many years. Previous repairs to the walls were very evident externally due to colour differences in the render finish. Significant previous movement within the house was also evident due to doorways being significantly „out of square‟, yet the damage around these doorways was minimal. The strip footings were identified as being only 300 mm deep. If the brick walls were articulated i.e. „ Articul ated full masonry‟ construction, then, for a Class H site, the footings would be required to be 1000 mm deep in accordance with a „standard design‟ to section 3 of AS2870. They would also need to be fully „gridded‟. However, for „ Full Masonry ‟ construction , a „ Design by Engineering Principles ‟ would be required in accordance with section 4 of AS2870. This would require an even stiffer footing system. The pattern and locations of internal and external wall distress were typical of differential foundation movements. There are various possible cause(s) of these differential moisture content changes, which have resulted in the foundation movements, including the following:- (i) Seasonal changes in soil moisture contents (ii) The relatively low rainfall (drought conditions) in Melbourne in recent years. (iii) The affects trees (sic) located in close proximity to the house (in particular, the tree which was removed from the garden bed outside the southern side of the living room). The tree roots may be causing soil drying settlements to occur, and locally amplifying the seasonal changes in soil moisture contents. (iv) Poor site drainage (v) Poor storm water drainage (3 down pipes discharge direction to ROW). (vi) The location of unpaved areas immediately adjacent the house (vii) Defective / leaking plumbing services. The most significant damage to the original section of the house has occurred in the regions of the house closest to the removed tree. In the writer‟s opinion, this indicates this tree removed from outside the living room has been a major contributing cause to the damage which has occurred in recent years. Relatively minor damage has occurred to the rear extension, however this damage includes a 5 mm approximate wide horizontal crack to the SW corner of the extension. In the writer‟ s opinion, the large tree Case No: 278037 Determination Page 9 of 22 removed from near the SW corner of the building is likely to have contributed significantly to this crack. The only defects identified in the hydraulic services are located at the southern end of the house (extension area), where there is relatively minimal building damage. The comments below are made in relation these defects:- i. In the writer‟s opinion, these defects have not contributed to the damage to the original section of the house. ii. In the writer‟s opinion, these defects may have contributed to some (likely minor) extent to the relatively minor damage to the rear extension (bathroom and laundry). In summary, this is an old house, with a grossly inadequate footing system for a high reactive clay soils. The house has brittle finishes externally and internally, and is sensitive to minor foundation movements. The property has been poorly maintained with respect to AS2870 Appendix B (and the CSIRO publication BTF18). In particular, trees have been located within the subject property too close to the house, the site drainage is poor, and the storm water drainage has not been adequately maintained. Even if the site maintenance is improved in accordance with AS2870 Appendix B, the house may continue to perform poorly due to the inadequa te footing system.” 39. On receipt of both of these reports, the FSP denied the Applicants‟ claim for a number of reasons. The Applicants disputed the findings of AL and FM and commissioned their own expert report from an engineer, BR who provided the following summary of his findings: “ CONCLUSION: I think in all probability the ground had dried out in underneath the foundations, that a torrential rain got into the foundations, softened the clay that was beneath the concrete, softening it to the extent it was incapable of offering support and thereafter the building settled into it and the most obvious rapid failure that is picked up on a large scale has then occurred. The continuum has been the small amounts of bouncing up and down; mailing up in this case as a bit of correction creeps in cracking the walls and making them look ugly.” 40. The Applicants forwarded BR‟s report to the FSP for further consideration however, the FSP did not accept the evidence provided by BR. In fact, in some instances the FSP opined that BR reported the opinion of FM. As such, the FSP continued to maintain its decision to deny the Applicants‟ claim. Consideration of the evidence 41. The onus of proof rests on the Applicants to establish that, on the balance of probabilities, they have suffered a loss caused by an insured event. Once the Applicants have established that the loss was caused by an event insured under their policy, the onus then shifts to the FSP to show that, on the balance of probabilities, the loss falls within an exclusion clause in the policy. Case No: 278037 Determination Page 10 of 22 42. The Applicants say that the report it commissioned from BR indicates that the most probable cause of the severe cracking they are claiming for, and which resulted in the property becoming uninhabitable, was storm water runoff. They say they have therefore proven they have a valid claim under their insurance policy with the FSP. 43. The FSP notes that BR did not inspect the property until approximately 18 months after the reported event. It also says that two of its experts, CS and FM agreed that the damage to the property was pre-existing and that FM and another expert, SG, both found that the presence of trees close to the house had caused damage to the house. It also says that BR agrees that the trees referred to by FM and SG were too close to the house in accordance with the relevant Australian Standard. 44. The FSP relies on the advice of its experts and denied the Applicants‟ claim based on its experts‟ reports. It says there are several causes of the damage, namely:  a failure to properly maintain or repair the insured property;  wear, tear and deterioration;  structural or other failure or breakdown;  soil movement and settlement; and  the actions of trees. All of these causes are excluded from the policy. 45. The Panel has reviewed the findings of all the experts. The Panel acknowledges that CS and SG inspected the property within two months of the damage being reported to the FSP; FM inspected the property within nine months of the damage being reported to the FSP; BR inspected the property approximately 18 months after the damage was reported to the FSP. 46. The Panel notes that with respect to the type of soil that the Applicants‟ property has been constructed upon, SG indicates the type as being Class H. BR has made no comment on the soil type. FM q uestions SG‟s assessment of the soil type indicating that he would classify the soil as Class P due to “abnormal soil moisture conditions caused the tree” [sic]. FM later suggests that a geological survey indicates the property is likely to have a Class H soil type and acknowledges that this was confirmed by SG‟s investigation. 47. Given that both SG and FM attended the property after trees were removed, and SG‟s report is based on findings of the soil tests he conducted, the Panel is satisfied that SG‟s opinio n on the class of soil is more reliable. 48. The Panel will address each cause of damage identified by the experts separately. Case No: 278037 Determination Page 11 of 22 Soil movement and settlement 49. The PDS clearly excludes soil movement and settlement. However in this instance the Panel notes that the FSP is relying on several other probable causes of the damage, as detailed above. There is no dispute between the parties that the soil has in fact moved which has caused the damage to the Applicants‟ property. What is in dispute is the cause of that soil movement. Failure to properly maintain or repair the insured property 50. In FM‟s report, he says in relation to the maintenance of the Applicants‟ property: “... The house has brittle finishes externally and internally, and is sensitive to minor foundation movements. The property has been poorly maintained with respect to AS2870 Appendix B (and the CSIRO publication BTF18). In particular, trees have been located within the subject property too close to the house, the site drainage is poor, and the storm water drainage has not been adequately maintained. Even if the site maintenance is improved in accordance with AS2870 Appendix B, the house may continue to perform poorly due to the inadequate footing system.” 51. FM does not detail why the site drainage is poor or in what way the storm water drainage would be required to be maintained, or even who would be responsible for this, i.e. local council, YV or the Applicants. Trees in the vicinity are discussed further in this Determination. 52. The Panel has not been provided with a copy of Australian Standard 2870 (AS2870) Appendix B or the CSIRO publication BTF18. As such, the Panel has not been afforded the ability to assess FM‟s comments in relation to maintenance of the site and its relevance to the Applicants‟ property . Additionally, FM has not specified what actions or inactions of the Applicants are relevant to these publications. 53. Of particular concern to the Panel is the relevance of these publications to the Applicants‟ property given the construction of the propert y occurred in excess of 100 years prior to the damage being noted. There is no information contained in the material as to when these publications came into being and whether or not they applied to the Applicants‟ property during their ownership of it. 54. The Panel is therefore not satisfied that there is enough evidence to support FM‟s opinion in this regard. Wear, tear and deterioration 55. The FSP has included in its denial of the Applicants‟ claim, the exclusion contained within its PDS regarding wear, tear and depreciation. The only relevant comments made by the experts in this regard is reference to the drought experienced in Victoria in the preceding 15 or so years prior to the claim being made, pre-existing cracks which have been previously repaired and doo rways being significantly „out of square‟. Case No: 278037 Determination Page 12 of 22 56. FM noted and photographed cracks within the property which appear to have been repaired previously. The Applicants agree that minor cracking had appeared and it had been repaired and that they are not claiming for these minor cracks. The Panel therefore accepts that there was some minor cracking at the property prior to the discovery of the larger cracks, the subject of the Applicants‟ claim. 57. The FSP and its experts however have not provided any link to how these existing minor cracks have caused or contributed to the larger cracks now evident at the Applicants‟ property. As the Applicants‟ claim relates to the larger more severe cracks at the property, the Panel is not satisfied that the pre-existing cracks have contributed to the current claim. The Panel is therefore not satisfied that this exclusion applies in this instance. Structural or other failure or breakdown 58. FM has suggested that the footings of the Applicants‟ property are inadequate given the soil type in the area. FM relies on AS2870 in respect to the correct type of footings required. He says: “The strip footings were identified as being only 300 mm deep. If the brick walls were articulated i.e. „ Articulated full masonry‟ construction, then, for a Class H site, the footings would be required to be 1000 mm deep in accordance with a „standard design‟ to section 3 of AS2870. They would also need to be fully „gridded‟. However, for „ Full Masonry ‟ construction, a „ Design by Engineering Principles ‟ would be req uired in accordance with section 4 of AS2870. This would require an even stiffer footing system.” 59. Again, reference is made to AS2870 and again, there is no supporting material to confirm how this standard relates to the Applicants‟ property or to substanti ate FM‟s comments. 60. The Panel is again concerned that FM has made no reference as to when this standard came into existence. In response, BR in his report commented in relation to AS2870: “... using Australian Standard 2870 as the guideline but note never a pplicable with this construction as it was built well before the document was even though of.” [sic] 61. The Panel is therefore satisfied that despite the construction of the footings at the Applicants‟ property and whether or not they meet current Australian Standards, the Standards referred to were not relevant at the time the property was constructed. 62. Of note, the Panel refers to the exclusion relevant to rainwater seeping into a property, as detailed in the PDS, which reads: “ You are not covered for ... Damage or loss caused by water seeping into or otherwise entering your landlord building due to: Case No: 278037 Determination Page 13 of 22 a defect or fault in the design, structure or construction of your landlord building where you could reasonably be expected to be aware of the defect or f ault ...” 63. In this instance, the Panel is satisfied that the Applicants could not reasonably have been expected to be aware of the footings being inadequate, given that at the time the building was constructed, there were no relevant standards or codes that would have applied. Accordingly, the Panel is of the opinion that this exclusion cannot be applied in this instance. The actions of trees 64. CS has indicated the presence of two “large” trees at the rear of the Applicants‟ property and a “mature” tree within 600mm of where the majority of damage has occurred. CS is the only expert who has inspected the property who sighted the trees and in fact advised the Applicants to remove them. The Applicants did remove the trees on CS‟s advice. In a file note within the FSP‟s material dated 8 November 2010 CE refers to the “mature” tree as a “small tree”. 65. FM makes reference to the trees after having reviewed aerial photographs of the Applicants‟ property which he retrieved via an online website. He refers to the trees as being “significant”. Based on the aerial photographs he discovered, he sought an amendment by SG to SG‟s report in relation to the presence of trees and the effect this would have on the Applicants‟ property, which SG provided. 66. BR also made comment on the possible effect trees in the vicinity of the Applicants‟ property may have had in relation to the cause of the damage to the property. 67. Unfortunately, none of the experts have provided any information on the actual size of the trees referred to, either in height or diameter of their trunks. Whilst CS and FM have attributed much of the damage at the Applicants‟ property to these trees, they have not provided details of the type of trees, root systems, root activities or how this can or would affect the soil or property. 68. In contrast, the Applicants have provided a photograph of a tree stump which remains at the Applicants‟ property after the removal of the tree. The tree stump depicted in the Applicants‟ photograph, in the Panel‟s opinion, does not represent a stump of a “large” or “significant” tree. 69. BR has acknowledged that based on where he was advised trees existed at the property prior to his inspection and prior to their removal, that the tree referred to by the FSP as being a contributor to the damage, was too close to the property. BR referred to this tree as “small”. His opinion on the impact this tree had on the damage is: “I was further informed that allegations were levelled against the small tree tucked into the corner behind the second bedroom. I think it was highly unlikely that a tree of that size, irrespective of how close, would have been Case No: 278037 Determination Page 14 of 22 able to cause the damage that is attributed, particularly as you get a lot further towards the back of the property. Remembering that this event occurred over a year and a half ago and therefore is somewhat difficult to be 100% certain as to total cause and total effect. However, I think it does get down to two causes and two effects; the first one being the reasonably small tree, it contributes to some local drying out in the ground and I would emphasise the word „local‟. I believe the major cause and effect of tree drying in this property and all around it are in fact the rather large trees focused along the lane on the other side of it, relatively speaking, and thereafter to a lesser extent in the zone under consideration, the trees in the rear of our own property. There can be no doubt that over the 15 years of drought that we have currently been through that the trees did have effect and did cause drying out, local consolidation and settlement. The major problem occurs is where they have actually dried out the ground in underneath and have not in fact initiated collapse of the building above as it is stiff and rigid but with time will eventually fail. However, the major trigger to such failure is that the air voids beneath the footings get filled with water from a very strong rain event and they in turn soften the soil locally down below the 140 shear vein measurement as picked up, i.e. the interface between the water and the clay becomes one of acute wetness and therefore even though the clays now tend to swell, they lose all bearing capacity as they are so wet, initiating collapse and movement. I believe this is far more likely the cause and effect situation, but it requires localised drying out of the ground directly in under the footings and thereafter water coming down the wall, most likely in this case as the footpath, paving etc. is not likely to allow it to flood against the building and thereafter the ground softens and the building collapse locally. The reason I believe this to be a high probability is that the [SG] investigation under the footing probe picked up a damp soil, very close to the dry soil attributed to the tree in behind the building. As a consequence you cannot have it both ways. The tree will eventually consume the excess moisture and gradually you will get equilibrium building up, i.e. leaks and trees go together; terminate one or the other and you get differential movement which we are now seeing in terms of reversed cracking and closure of some of the cracks relative to the information as given in the photographs by others. ... The tree had a very small effect in causing drying out in underneath and the storm that followed saturated the soil to an extent where it lost shear capacity, the wall moved and thereafter readjusted, both upwards and downwards. This we believe, to be the highest probability, based on past experience in this area.” 70. Whilst BR acknowledges that the “small” tree clo sest to the area of the significant damage to the Applicants‟ residence could have contributed to some localised drying out of the soil, he relies on the soil report from SG which indicates there is damp soil near the dry soil. The FSP‟s experts say this w as caused by the subject tree. BR notes “you cannot have it both ways”. The Panel is of the opinion that BR‟s report provides more insight into the effects of trees at the Applicants‟ property than the FSP‟s experts. Case No: 278037 Determination Page 15 of 22 71. BR also acknowledges that the subject tree was not at the site at the time of his inspection and that his inspection was conducted some 18 months after the event was reported, so he could not be 100% sure of the actual cause and effect. 72. The FSP argues that its experts attended at the property initially within two months of the damage having occurred and again only nine months after the damage occurred. Unfortunately, CS has failed to provide any pertinent information in relation to the trees and in fact advised the Applicants to remove them, which occurred prior to any further assessment of the property by any of the other experts. 73. Nevertheless BR did accept that the trees would have had some effect although to a lesser extent in the area under consideration. Storm water runoff/overflowing of water mains/sewer etc 74. BR in his report attributes the cause and effect of the damage to the Applicants‟ property as being rel ated to torrential rain which got into the foundations of the Applicants‟ property , causing the failure of the of the support and ultimately the large cracking to the walls. He also acknowledges that there were some failings in mains water structures in the vicinity, however has not sourced any significant effect from these failures to the cause of damage. 75. In contrast, FM has provided the following opinion in relation to storm water runoff and mains water structures: “[FM] disagrees the damage to the [Applicants‟] property has been caused by leakages from the storm water and sewer drainage services for the following reasons:- 1. The only known defects in the storm water drainage and hydraulic services are as follows:- b. A crack in the earthenware sewer water drain below the house in [Applicants‟ neighbour‟s property] (refer SK1) c. The storm water drain from down pipe located in SW corner of house (bathroom) is either blocked or „capped off‟. The above defects are located at the southern end of the house, where there is relatively small amount of distress compared to the remainder of the house. [FM] agrees that these defects may be contributed to some (likely minor) extent the (relatively minor) distress to the rear extension (i.e. bathroom and laundry), however, we do not believe they would be contributing to the distress to the original section of the house. ... It is [FM]‟s understanding that the laneway did not „collapse‟, however that, upon local excavations carried out by [YV], a void was found below the ground surface with water. The letter from [YV] to [local council] dated 5 May 2010 states:- „Although subsidence was not evident on th e surface a void was found with water following excavation of the area‟ Case No: 278037 Determination Page 16 of 22 There is no evidence that the foundations of [the Applicants‟ property] have been „undermined‟ .” 76. It is interesting that two experts can have such vastly differing opinions with respect to the effect of storm water runoff. FM, for example, explains that an old pit, identified by YV to be apparently redundant, could be retaining water entering the pit via redundant and unplugged drains or ground water. He makes no mention of this pit retaining water from any storm or rainwater event and in fact, remains silent on this issue. 77. It would appear that FM was very focussed on the trees at the property and the effect they have had in contributing to the damage to the Applicants‟ property. The Panel is not satisfied that FM has properly considered the extent of the heavy rainfall experienced in the Applicants‟ area during November/December 2009. Proximate cause 78. The policy covers the event of storm and rainwater, including rainwater runoff. The evidence provided by the Applicants in their submissions and by their expert BR, is that the heavy rainfall experienced in November and December 2009 has caused the soil under the footings of the property to essentially fail. The FSP does not dispute that water has inundated the property and gone into the soil under the footings of the property. 79. A review of the exclusions indicates that the policy does not cover any loss or damage as a result of or caused by soil movement and settlement. The Panel must therefore consider whether the proximate cause of the loss is the soil movement or the heavy rainfall. 80. The Panel is satisfied that it is incorrect to look at the most immediate cause when considering the proximate cause of damage; instead, one looks to the “quality of the connection between [the] cause and the injury”. The correct test for proximate cause is that it should be the “active, efficient cause that sets in motion a train of events without intervention of any independent force”. 81. On reviewing the issues, it is suggested that the soil movement has not occurred independently. Further, the property damage occurred temporally proximate to the heavy rainfall. 82. The Panel cannot accept that the soil movement should be considered an independently occurring consecutive or concurrent cause of loss to the rainfall. This is because the soil movement is a result of the rainfall and is a result conditional on this event. It is doubtful that the damage viewed, would have occurred but for this heavy rainfall. 83. The exclusion has therefore not been made out, because it is not damage which is the result of or caused by soil movement and settlement in and of itself. The damage has arisen due to the water inundation which then Case No: 278037 Determination Page 17 of 22 resulted in the volumetric changes to the soil and subsequent cracking to the walls of the property. 84. The Panel further notes it is the policy‟s cl ear intention to cover damage arising from storm water inundation. Accordingly, the commercial intention of the policy, should extend to damage caused by stormwater which results in soil movement rather than soil movement acting naturally and gradually without any single causal event. 85. In any event the FSP in its letter of 4 March 2011 accepted and made a settlement of the claim in the amount of $3,964.38. It therefore follows that it accepted a prima facie claim and has the onus of establishing those parts of the claim for which its policy does not provide cover. 86. Although a claim has been established, it appears that there were other contributing factors in the loss, including some contribution from the effect of the trees. Further, there is evidence of previous movement as evidenced by repair to a number of older cracks, although said by the Applicants to be small cracks. 87. Although there were other contributing factors, the Panel is persuaded that the cause of the majority of the damage was the storms as claimed by the Applicants. However, in the Panel‟s view it is appropriate to consider an apportionment of the total cost of repairs relative to the extent of storm damage and the other damage. The extent to which the storm damage or the other causes contributed to loss is unclear from the available evidence and given the loss occurred some three years ago and the house has since been sold, more probative evidence in that regard is not available. 88. In these circumstances the Panel is inclined to rely on its mandate to do what is fair in all the circumstances, The Panel therefore determines that it is fair that the FSP bear the cost of 70% of the damage claimed and the Applicants bear 30% of the loss. 89. There is little evidence as to the exact cost of rectification, although the Applicants have provided a quote for underpinning at $36,190. They also estimate that the cost of internal repairs would be in the order of $10,000 and although not supported by any expert evidence, this appears not unreasonable. The total thus claimed is $46,190, of which the FSP is to contribute 70%. 90. Therefore, the Panel determines that the FSP is to pay the Applicants an amount of $32,333, less any sum already paid (noting its previous offer of settlement for $3,964.38) in settlement of damage to the house. Loss of Rent 91. The Applicants seek to have loss of rent paid from the time their tenants vacated the property on the advice of the FSP‟s assessor (15 February 2010) to the time the property was re-let (1 August 2011). Case No: 278037 Determination Page 18 of 22 92. The FSP says the fact the Applicants were able to re-let the property with apparently no rectification or repair work being completed to the property, indicates that the property was in fact liveable. 93. The Panel notes comments made by the FSP in file notes indicating on 3 May 2011, the FSP claims to have no information or knowledge of when the tenant vacated. This is contrary to FM‟s report dated 12 November 2010 which indicates FM spoke with the tenant who advised they moved out of the property on 14 February 2010 on the advice of the „inspector‟. 94. Conversely, the Panel is mindful that the Applicants are required to take reasonable steps to mitigate their loss, despite the dispute with the FSP. Mitigation in this instance could be the repair and/or reletting of the property. However, as is now known, the Applicants ultimately sold the property in its distressed state. 95. Nevertheless, even if the Applicants had undertaken remedial action, the house would likely be un-tenantable for a period of time while repairs were being carried out. On that basis the Panel is again inclined to do what is fair in all the circumstances and is of the view that a period of up to 3 months would be required to undertake and complete the required works, including underpinning, repairs, repainting etc. 96. Given the approach applied on the damage claim, the FSP is required to pay 70% of the rental for that period. The evidence provided indicates that rental of $1,282 per month was appropriate. Therefore the FSP is required to pay an amount of $2,692.20, being 70% of the rental for a three month period. Other matters 97. The Panel also notes concerns raised by the Applicants in respect to FM‟s request of SG to “amend” SG‟s report. These ame ndments related to the incorrect reference to bore holes and a request that SG make comment on trees and their impact in the vicinity of the damage being claimed. 98. The FSP advised that SG physically re-attended the site at the request of FM and then amended the report. However, from the emails provided by the FSP between FM and SG, the Panel can detect no such inference that a reinspection was conducted by SG. 99. The Panel is also somewhat concerned that an expert tasked by the FSP has requested another expert to amend a report. The question was not asked of SG to clarify information, rather a request was made to alter SG‟s original report. 100. The Panel is satisfied that the Applicants‟ concerns in this regard are well founded and the Panel is therefore not satisfied that the second report from SG, especially in relation to the trees at the site, can be considered relevant to the issues in dispute, given that report was clearly influenced by another expert‟s request. Case No: 278037 Determination Page 19 of 22 Whether the FSP has acted in a manner which delayed the resolution of this matter 101. The Panel has reviewed the material and developed the following timeline of events:  Claim lodged by Applicants on or around 13 January 2010.  The FSP‟s CS attended the property on 10 February 2010 to assess the damage.  SG was appointed by the FSP to expertly comment on the property on 15 February 2010.  SG‟s report is dated 9 March 2010.  CS contacted the Applicants and verbally advised them that the FSP‟s decision is to deny their claim on 11 March 2010.  The Applicants sent an email to the FSP requesting a written response regarding the denial of the claim on 6 June 2010.  The Applicants seek a formal response to their claim on 9 June 2010.  The FSP forwarded a written denial of the claim on 15 June 2010.  The Applicants wrote to the FSP requesting a review of the decision on 7 July 2010.  The matter was considered through the FSP‟s Internal Disputes Resolution (IDR) process and was passed back to the claims area for further investigation on 19 July 2010. A letter was sent to the Applicants advising them of this on the same day.  AL conducted leak detection tests at the Applicants property on 6 August 2010.  FM inspected the property on 10 October 2010.  CS reviews the reports from AL and FM on 29 November 2011 and advises Applicants on the same day that there is no claim/no cover.  Formal denial letter requested by Applicants on 29 November 2011.  FSP file sent to its administration area for a formal denial letter to be sent on 18 December 2010.  Applicants contact FSP on 6 January 2011 and were advised that part of the damage may be accepted and a scope of works is being arranged for relevant repairs.  File allocated to assessor on 2 February 2011 to create a scope of works based on FM report.  The Applicants forwarded a letter to the FSP on 4 February 2011 disputing the findings of FM and questioned amendments made by SG to his original report.  Matter reviewed by FSP and letter sent to Applicants advising of outcome of that review on 4 March 2011. Case No: 278037 Determination Page 20 of 22  Applicants request a further review of decision in writing on 10 March 2011.  The FSP maintained its decision through its IDR department on 14 April 2011.  A review of loss of rent claim made by FSP on 3 May 2011 and details of claim requested from Applicants as there was no information located by the FSP at this time as to when the tenants moved out.  The Applicants provided a report from their expert, BR, on 13 November 2011. The report was dated 25 July 2011 and the delay in it being provided to the FSP was due to the Applicants‟ solicitor being on leave between July and November 2011. 102. The Panel accepts that the FSP is entitled to conduct enquiries in relation to the full circumstances surrounding the Applicants‟ claim. The Panel also acknowledges and accepts that during times of catastrophic weather events the resources of any FSP are stretched to cope with the unusually high influx of new claims and the additional demands of policyholders who have been displaced from their usual residences. 103. The storm events in Melbourne during November and December 2009 and which the Applicants‟ rely on as having caused the damage to their property, certainly falls into this category. It is therefore reasonable to accept that some delays would occur during the claims handling process. 104. However, The Panel is of the opinion that unnecessary delays have been caused by the FSP, particularly in providing the Applicants with formal denial letters and responding to the Applicants‟ concerns. In addition there appears to have been an unacceptable delay between assessments completed by AL and FM and the FSP has not provided any reason for these delays. 105. In its letter to the Applicants on 14 April 2011 the FSP acknowledged that it had failed to meet the Applicants‟ expectation with respect to its handling of the claim and it had breached its own Customer Charter and the General Insurance Code of Practice. 106. Accordingly, the Panel is satisfied that unacceptable delays have been present during the process of this claim and most of those delays were caused by the FSP. Compensation 107. The Panel has given consideration to another aspect of the matter which is of concern. FOS Terms of Reference “ 9.3 Other compensation a) Subject to paragraph 9.3 c) and paragraph 9.7, FOS may decide that the Financial Services Provider compensate the Applicant for Case No: 278037 Determination Page 21 of 22 consequential financial loss or damage up to a maximum amount of $3,000 per claim made in the Dispute. b) Subject to paragraph 9.3 c) and paragraph 9.7, FOS may decide that the Financial Services Provider compensate the Applicant for non- financial loss but only where: (i) an unusual degree or extent of physical inconvenience, time taken to resolve the situation or interference with the Applicant‟s expectation of enjoyment or peace of mind has occurred; or (ii) in the case of a Dispute pertaining to an individual‟s privacy rights - injury has occurred to the Applicant‟s feelings or humiliation has been suffered by the Applicant. The maximum amount of compensation for non-financial loss will be $3,000 per claim made in the Dispute. ” 108. The Applicants seek to be reimbursed for the amount they have lost on the sale of the property due to the unrepaired damage reducing the value of the home. In an effort to support their loss, they have provided a letter from their real estate agent which says: “There is no doubt in my mind that the condition of the building, namely the structural damage that was plainly evident to the southern most and adjoining walls had a negative impact on sale price of this property. This fact is illustrated to me best by looking at the feedback provided by my follow up calls of the 52 inspections we had by buyers over a four week period. Only two buyers were prepared to exchange contracts at a maximum of $450,000, all the rest had said that it was „too much work‟. The following recent sales analysis provide a strong indication of 2 bedroom properties in [Applicants‟ suburb] with a land size of between 100m2 and 150m2. ([Applicants‟ property] is 135m2 approximately). The median price per square meter for these properties is $4385. Multiply this by the land of [the Applicants‟ property] and you have a price guide of close to $600,000. this is what [the Applicants‟ property] would have achieved in this market if it were a sound, undamaged construction .. .” 109. The FSP says it is not liable for this amount. Whilst the FSP remains satisfied that its decision to deny the Applicants‟ claim is correct, it says that should FOS find in favour of the Applicants, its liability is limited to the cost of repairing the damage to the building. Additionally, it says FOS is only able to award a maximum of $3,000 in accordance with 9.3 a) of the TOR. 110. The Panel is of the view that the FSP is correct in assessing its liability to be limited to the cost of repairs to the Applica nts‟ building. In addition, whilst the Applicants‟ real estate agent has confirmed that the property sold for a good deal less than what he believes could have been realised had the property been in a sound condition, the Panel has not been provided with e nough information to accept that the total difference in the price is relative to the condition of the property. 111. The Panel is aware that there are a number of factors which affect the sale of a property, the condition of the property being one such factor. The Panel Case No: 278037 Determination Page 22 of 22 is satisfied that the repairs required to rectify the damage as claimed by the Applicants‟ would have been significant enough to contribute to a loss in sale price. 112. For the reasons detailed above, the Panel is of the opinion that the FSP should have authorised the relevant repairs for which it is liable. As it did not, it cannot now rely on reducing its liability to the cost of repairs only, given that the Applicants would on the balance of probabilities have suffered some loss of value on the sale of the property, given the unrepaired damage present. 113. In the Panel‟s opinion the FSP has failed to authorise the repairs to the Applicants‟ property and as the Applicants decided to sell the property “as is”, the Panel is satisfied that some loss on the sale price would have been attributed to the condition of the property due to repairs no being authorised. 114. The Panel therefore considers that the FSP should further compensate the Applicants by payment of the sum of $3,000 under this heading. Determination 115. On the basis of the available information the Panel determines that the FSP was not entitled to deny the Applicants‟ claim. 116. The FSP is to pay the Applicants an amount of $32,333 in respect of the damage to the building. 117. The FSP is also required to pay the Applicants an amount of $2,692.20 in respect of loss of rent. 118. The FSP is entitled to deduct from the amount payable any settlement amount already paid, together with any excess which may be payable under the terms of the policy. 119. The Panel further determines the FSP should pay interest on both the cost of repairs and loss of rent sums from the date the insurer denied the claim verbally (11 March 2010) to the date when this Determination is satisfied in accordance with Section 57 of the Insurance Contracts Act 1984 (Cth). 120. The Panel also determines that the Applicants are entitled to compensation for the loss of value on the sale of the property for the amount of $3,000.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.