Home / Financial Firm (Unknown - Insurer) / Determination 270911
Determination 270911
Leaking garage roof declined as wear and tear or faulty construction
Summary
The applicant claimed for replacement of a leaking garage roof, which the insurer declined as caused by wear and tear or faulty installation. AFCA found the insurer entitled to deny the claim, having paid $239 for internal water damage.
The applicant bears the onus to prove an insured event such as escaped gutter water or rain, and the evidence showed the leak was likely caused by the roof's construction and sweating from a second sheet of iron, which the policy excludes.
Subjects and remedies
no remedy
Text of the determination
Case No: 270911 Determination Page 1 of 5
Case number: 270911
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Claim amount
28 February 2013
Background
1. This is a review of a Recommendation by the Service’s Case Manager dated
17 January 2013. The Applicant has rejected the Recommendation and in
accordance with the Terms of Reference, this matter has been referred to
me for Determination.
2. The relevant background, summaries of the parties’ position and issue to be
determined are set out in paragraphs 1 to 12 and I will restate same:
“1. The Applicant’s home was insured with the Financial Services Provider (FSP)
under a home policy.
2. He claimed for water damage to his garage on 3 February 2011.
3. The FSP accepted liability for the internal damage to the garage but otherwise
declined liability for the external damage (ie. the leak in the garage roof) on
the basis that it was the result of wear and tear and/or a structural defect.
4. The Applicant believes he is entitled to indemnity for the replacement of the
garage roof.
Summary of Applicant’s position
5. The assessor who prepared the report relied on by the FSP (“IC”) did not
inspect the garage. The garage was inspected by a person named “S”.
6. The neighbour’s rusted gutter had been leaking for “the past few years”,
causing damage to the layer of insulation between the two layers of
corrugated iron sheets.
7. The declined the claim because of his poor command of English.
Summary of FSP’s position
8. The garage leak is due to a construction defect and not an insured event. Its
assessor and roof specialist have reported that the garage’s roof sheets were
not properly installed and were the cause of the leak.
Determination
Case No: 270911 Determination Page 2 of 5
9. The construction of the garage roof promoted “a sweating reaction”, resulting
in salt residue and rusting of the roof sheets.
10. It has not declined the Applicant’s claim on the basis he has language
difficulties.
11. Although the FSP has referred to a number of policy provisions in its
submissions, it appears principally rely on the following provisions for
purposes of the dispute:
“ General exclusions applicable to your policy
You are not covered under any section of this policy for damage, loss or
liability caused by, arising from or involving any of the following:
…
Water entering your home:
as a result of your failure to perform adequate maintenance on your
home, or a structural defect, or faulty design or workmanship,
…
Wear and tear, lack of maintenance or inherent defect.
Rust, corrosion… and other signs of failure to keep your home in good
order and repair.
…
Structural defects or faulty workmanship…”
Issue
12. Whether the Applicant is entitled to indemnity for the damage to his garage
roof. ”
Reasons for decision
3. There has been a full exchange of information and each party has had the
opportunity to address the issues that have been raised.
4. I have read all of the exchanged information and I have considered the
parties’ submissions including the Applicant’s further submission dated 28
January 2013.
5. In making his Recommendation, the Service’s Case Manager set out his
reasons in paragraphs 14 to 25 of the Recommendation and I will restate
same:
“14. I have considered the following policy provisions in addition to the provisions
referred to by the FSP in its submissions:
“Home Insurance – What IS covered
Escape of liquid from the following.
Case No: 270911 Determination Page 3 of 5
Any… gutter or guttering…
…
Storm, hail or rainwater ”
15. There is no dispute that the Applicant’s garage had sustained water damage.
The FSP accepted liability for the internal damage and had paid the Applicant
$239 (net of the policy’s $300 excess) for such damage.
16. The issue in dispute is whether the Applicant is entitled to indemnity for the
leaking garage roof.
17. He believes he is entitled to indemnity because the neighbour’s rusted gutter
had been leaking for “the past few years”, causi ng damage to the layer of
insulation between the two layers of corrugated iron sheets.
18. The FSP maintains that the roof was defective as a result of wear and tear
and improper installation.
19. I have carefully reviewed the material exchanged and am satisfied that the
FSP is not responsible for the cost of rectifying the leaking roof.
20. According to the material exchanged:
The Applicant’s garage roof is constructed of two layers of corrugated
iron sheets, with one layer sitting on top of the other.
The Applicant explained:
i. The garage’s asbestos roof was replaced with a single layer of
iron roof sheets in 1989.
ii. However, this proved to be too hot during summer so a layer of
insulation was added together with a second layer of iron roof
sheets a few years later.
The F SP’s builder was of the opinion that:
i. The roof sheets were incorrectly installed and were the cause
of the leak.
ii. The placing of a layer of iron roof sheets on top of another layer
of iron roof sheets “will cause sweating reaction resulting in salt
residue and rusting of roof sheets”.
iii. The properties on either side of the garage did not contribute
the garage leak.
21. I am mindful that the policy covers damage caused by water escaping gutters
as well as rainwater damage. In this regard, the Applicant has provided a roof
replacement quote which suggests that the garage roof was damaged “via
adjoining building box gutter leakage”.
22. However, neither the roofer who prepared the quote nor the Applicant
provided any reasonable explanation or evidence showing:
The nature of the damage allegedly caused to the garage roof by the
neighbour’s gutter leak.
Case No: 270911 Determination Page 4 of 5
How rainwater escaping from the neighbouring leaking gutter could
damage to the garage roof given that a roof is meant, and should
ordinarily be able to cope with water.
Why the entire roof warranted replacement when water purportedly
escaping the neighbour’s gutter is unlikely to have influence over the
entire garage roof.
23. In any case, the evidence before me is reasonably consistent with a view that
the leak in the garage roof as well as the water damage to the insulation layer
was likely due to long term deterioration of the roof structure which was likely
caused by the manner in which the roof was constructed.
24. Whilst the FSP’s has not strictly shown that the roof’s construct ion was not in
accordance with the manufacturer’s requirements (as it claims), I nonetheless
find it unusual for a garage roof to be constructed with two layers of
corrugated iron sheets with a layer of insulation sandwiched between the two
layers of iron sheets.
25. On the balance of probabilities, I am satisfied on the evidence that FSP has
established the operation of the policy provisions that purport to exclude loss
or damage caused by wear and tear, and faulty construction. ”
6. In my opinion the Service’s Ca se Manager has properly considered the
relevant matters and I agree with his reasoning and his recommended
outcome. I add the following further comments.
7. The Applicant is charged with responsibility of proving that his home has
been damaged by an insured event. The only relevant event under this
policy is the escape of liquid from any gutter or guttering or storm, hail or rain
water as referred to in paragraph 14 of the Recommendation.
8. The FSP relies upon reports from its assessor and also its builder (B).
9. The builder stated in his report dated 12 November:
“ Our inspection of flat corrugated iron roof to Garage has found existing
corrugated roof to Garage has been covered over with a second sheet of
corrugated iron. This will cause a sweating reaction resulting in salt residue
and rusting of roof sheets
Salt residue to underside of metal roof sheets and side walls of Garage
internally. In our opinion damage has been caused by incorrect installation of
metal roof sheets / flashings and are not in accordance with manufacturers
specifications.
It is further to our opinion damage problem and resulted damage are a
construction fault to be addressed to by Insured.
It is also our opinion property each side of Garage is not contributing to
problem or resulted damage Insured is experiencing. ”
10. A further report was supplied by B on 9 January 2012 confirming its advice
that the roof sheeting had not been installed in compliance with the
manufacturer ’ s recommendations.
Case No: 270911 Determination Page 5 of 5
11. The Applicant disagrees with the insured’s expert but save for providing
some further photographs of the alleged damage he has not provided any
cogent evidence to support his opinion that the damage is caused by water
flowing from his neighbours guttering.
12. I note with approval the Service’s Case Manager’s o pinion that a well
constructed roof should nevertheless cope with discharge of water. The far
more likely cause of the problem to the roof is the sweating reaction caused
to the roof by the emplacement of a second sheet of corrugated iron as
referred to in B’s report dated 12 November 2011.
13. I am not satisfied the Applicant has established the damage to his roof was
caused by an event covered under the terms of the policy.
Determination
14. The FSP is entitled to deny the claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.