Home / Financial Firm (Unknown - Insurer) / Determination 270421

Determination 270421

Claim declined as wall damage not caused by insured storm or flood event

FirmFinancial Firm (Unknown - Insurer)
Decided2012-08-22
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed$6,908
SourceAFCA PDF

Summary

An investor claimed for internal wall damage after the January 2011 storms, and the FSP declined it as subsidence. AFCA found the decline was not justified and ordered payment of repairs and policy loss of rent, reimbursement of the engineer's report and interest, with two excesses permitted.

The storm insured event was established on the expert evidence, and the FSP did not prove that the subsidence or humidity exclusions applied.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay compensationpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 270421 Determination Page 1 of 8 Case number: 270421 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim 15 August 2012 Background 1. The Applicant holds an Investor Home and Contents policy of insurance with the Financial Services Provider (FSP) covering the insured building up to $141,200. 2. On 17 August 2011 the Applicant lodged a claim with the FSP for damage to the property. The claim was recorded as follows: “There is two walls in the house moving out (a deflection in the wall), one in the lounge and one in the entrance/ You can see that they have moved/ I think it is from moisture and rain from last year/ I have checked the roof and can‟t find any leaks at all/ These are in two separate areas of the home and are not near each oth er” (sic) 3. The FSP obtained an assessor and building inspector opinion and declined the claim on the basis the damage was not caused by an insured event. 4. The Applicant disputes the claim declinature on the basis that the flood and/or storm event damaged the property and these are insured events. Summary of Applicant’s p osition 5. The Applicant has enclosed engineering report dated 5 December 2011 from which I note the following:  There is no evidence of any „uplift of stumps‟.  The bowing in the wall is not caused by bowed timber members but rather it is the result of the gyprock cladding coming away from the wall frame.  As the damage occurred during the January 2011 storms, the damage is likely to have arisen from prolonged high humidity which has the effect of softening the gyprock walls.  This wall was also found to be load bearing. Accordingly, the combined effects of heavy rain and cyclonic winds at the time would supply enough vibration in the wall to allow it to shed the weakened gyprock material. Determination Case No: 270421 Determination Page 2 of 8  The engineer concluded the damage was the direct result of the January storms. 6. The Applicant has enclosed engineering report dated 19 December 2011 from which I note the following:  The damage was ultimately caused by high winds in the area during January 2011.  The Bureau of Meteorology recordings at Amberley and Archerfield have been obtained. The location of the insured property is between these two stations.  Gusts between 56-59km/hr over 9-10 January 2011 were recorded. Further there were gusts up to 44-96km/hr recorded on 18 January 2011. 7. The Applicant has enclosed a building report dated 1 November 2011 from which I note the following:  The usual signs of movement are not present externally or under the house.  There are no gaps between stumps and bearer.  The wall which suffered damage is a main support wall.  The builder is critical of the FSP‟s expert and states the „detachment of moldings‟ is actual ly a shadow line created by the flash of the camera.  The builder believed the FSP‟s expert report contained contradictions and he queries how a conclusion could be arrived at to state it was pre - existing damage. 8. The Applicant has enclosed the property inspection reports and statement from the property manager. The statement confirms the material contained in the property inspection reports. That is, there was never a previous mention of the walls in the lounge and dining rooms in prior inspections or regarding cracking generally. The summer of 2010-2011 was very wet and at an inspection on 8 February 2011 the walls were found to have been warped. It is not considered to be caused by the tenants or their guests. 9. The Applicant submits that the tenant noticed the bowing in the walls shortly after the January 2011 floods. The tenant reported this to the property manager and the damage was confirmed through an inspection. Further discussion with the tenant has indicated the deflections were visible in January/February 2011 but he did not see any other movements or failures elsewhere in the home. There was no recollection of water ingress but the tenant did recall there were significant storm activities over a prolonged period in January 2011. 10. The Applicant notes the basis for rejection by the FSP has been the swelling and heave of the foundations over an extended period of time. The Applicant relies on his expert reports which state the damage arose due to strong winds combined with heavy rain, storm and humidity. The policy covers storm and accordingly the Applicant contends it should be covered. Case No: 270421 Determination Page 3 of 8 11. The Applicant has reviewed the expert report provided by the FSP and states the following in relation to same:  The age of the house is incorrectly stated, the age is 36-37 years.  There were no previous structural repairs (including brickwork) and nor were ceiling repairs carried out in the property in the last 20 years. There was no prior movement in the home, brickwork repairs and/or visibly deflected ceilings in the home.  The fact that there are no defects or damage to the perimeter, brickwork/strip footings supports the argument there are no movements in the foundation strip footings or brickwork.  There are no gaps between the bearers and stumps. All the original steel tie bars are still in place.  The cornices are intact even in the areas of distorted walls.  The expert‟s confi rmation that no movement has occurred in the concrete stumps or bearers supports the Applicant‟s position.  There is no way stormwater could enter as alleged, as the brickwork foundation is surrounding that area and it is located above the building pad. The report also noted there was no sign of water entry at the time of inspection.  There is no clear reason provided for the deflection of the two internal timber wall sections in the house other than saying slow movement of the foundations. 12. It is the Applica nt‟s position that the timber posts behind the walls were subjected to significant moisture ingress and wind from storm activities directly associated with the January floods. The swelling would have occurred within a relatively short period of time and there is no evidence to support that this has caused by the movements of the foundation, footings or other load bearing components in the structure. 13. The Applicant notes the strong winds were able to general sufficient uplift pressure in split level homes with above ground floor arrangements. As a result it is possible to induce wall failures as witnessed in the insured property. 14. The Applicant seeks the cost of repairs, loss of rent and the cost of the engineer‟s report less his excess. This totals $6,908. Summary of FSP’ s position 15. The FSP has enclosed its assessor ‟s report dated 24 August 2011 from which I note the following:  The residence is high set and has brick veneer. The assessor believed it was average to poor condition with maintenance issues. Case No: 270421 Determination Page 4 of 8  The tenant stated that not long after the flood, they were moving furniture around when they noticed the bowing in the lounge room and then kitchen walls.  There was no evidence of water damage but movement was noted throughout the house with some areas being pa tched. The assessor recommended engaging an engineer. 16. The FSP has enclosed its engineer report dated 2 October 2011 from which I note the following:  There are no defects or damage observed to the perimeter brickwork as a result of building movement.  The stumps support the upper floor timber bearers. Some of the stumps did not provide support to all of the bearers and a gap existed between the bearer and the top of the stump.  In the area where movement of the elevated floor had occurred, it was observed there was limited ventilation whereby water intrusion would take some time to dry.  There was evidence of bowing to the timber framed walling of the entry/hallway. This bowing was measured to be around 30-40mm over the height of the wall on the elevated timber floor. Bowing was also noted to the living room walls as well as distortion of the ceiling cornices.  The engineer concluded that excess water penetrated the subfloor foundation soils from water run-off and subsoil saturation. The clay based soils will expand in volume when water penetration occurs. The subfloor area where movement has occurred has limited ventilation and this causes a slow response for drying of this soil material.  Typically the clay soil saturation results in heave which causes uplift on the stumps which support the floor bearers which in turn support the timber framed walls. In some cases the drying process does not return the concrete based pads to the original founding level. Furthermore, permanent deformation of the timber bearers can also occur from upward pressure of the stumps; however this was not evidence in any reasonable extent at the time of the inspection.  In relation to the timeframe of the movement, the engineer opined that the soils swelled gradually as they became saturated over the extended period of wet experienced in Queensland at this time. The swelling would not have been immediate, but would have occurred over the extended period it took for the soils to become saturated and expand. 17. The FSP has enclosed a wind scale. I note that at 51-62km/hr whole trees are in motion and there is inconvenience felt when walking against wind. The rate of 88-102km/hr is described as being seldom experienced inland with trees uprooted and considerable structural damage. 18. The FSP‟s policy provides cover for the listed events. Accordingly the Applicant has to demonstrate that the damage arose under the insured event of storm and flood. The FSP contends that the Applicant has not done so. Case No: 270421 Determination Page 5 of 8 19. The FSP notes its assessor could not locate any areas of water entry in the vicinity of the bowed walls and no other areas of the home were found to have suffered damage due to storm activity. 20. The expert engineer provided an opinion that the internal wall bowing was the result of swelling foundation soils after saturation from the January 2011 storms and floods. Further that the soils swelled gradually. 21. The FSP contends the expert opinion confirms the damage occurred from earth movement which is specifically excluded under the policy. Further, there is no evidence that the home became damaged within 72 hours of an insured event. Accordingly, the claim is excluded from cover under all sections of the policy. 22. The FSP has reviewed the engineer report provided by the Applicant and responds as follows:  The engineer stated the internal gyprock wall linings bowed due to prolonged high humidity. The policy specifically excludes damage arising from atmospheric or climatic conditions and accordingly the humidity as a cause of loss is excluded.  Based on the wind scale, th e gusts of 59km/hr were „strong‟ but not cyclonic as claimed by the Applicant‟s engineer.  In relation to the wind gusts measuring 96km/hr the FSP says that if the insured property was subject to such winds that it would be reasonable to expect that some exterior structural damage would also be evident. However, there was no exterior damage at all.  The FSP further notes that there is no information as to the direction of the winds or as to the direction the walls face. Further, no consideration of local topography and the effects of same on wind conditions over the suggested period of such winds have been provided.  If the damage indeed occurred over the suggested period of 9 days, this could not be considered a single event as defined in the policy. The policy specifically relates to a single occurrence. 23. The FSP submits that whilst the expert opinions are inconsistent as to the cause of damage, both have attributed the damage to excluded causes of loss under the policy. Accordingly, the FSP is entitled to decline the claim. Issue 24. Whether the FSP was entitled to decline the Applicant‟s claim for damage. Reasons for Determination 25. Due to the nature of the dispute, FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. Thus, this dispute has not been the subject of a Case No: 270421 Determination Page 6 of 8 FOS Recommendation and has proceeded directly to Determination. The parties have been previously advised that a Determination will be issued in this case. 26. There has been an exchange of material between each party, and I am satisfied each party has had an opportunity to reply to the issues raised. 27. I have read each party‟s submissions and materials and will only refer to the relevant submissions and materials raised. 28. The parties do not dispute that the policy provides cover for storm and flood and subsidence provided the subsidence occurs within 72 hours of a storm or flood event. 29. I consider the following policy definitions are relevant to an assessment of this matter: “incident or event A single occurrence which is not intended or expected to happen by you ... Storm A violent atmospheric disturbance, producing strong winds. It can be accompanied by rain, lightning, hail or snow.” 30. There is no particular dispute that the January 2011 flood and storm events in Queensland would fall under the policy description of „storm‟. There is also no dispute that the insured property was subject to the storm events of January 2011. 31. The issues before me for determination are - what caused the deflection of the walls and does it fall within the cover provided by the policy. 32. I have reviewed the expert evidence and in particular the engineering reports of each party. 33. It is with some interest that I note that neither the Applicant‟s engineer nor the FSP‟s engineer could find proper evidence of uplift in the stumps. It appears that the FSP ‟s engineer theorises that permanent deformation of the timber bearers can also occur from upward pressure of the stumps; however this was not evidence in any reasonable extent at the time of the inspection. 34. There is a lack of clarity within the FSP‟s engineer‟s report regarding the observable evidence on which the conclusion was based, that is the damage resulted from upward lift of the stumps. 35. In contrast, the Applicant‟s engineer and builder both stated there was no evidence of any uplift of stumps. I must say that I do find the A pplicant‟s engineer ‟ s report to be the most valuable. 36. On the basis of the evidence, I do not consider the FSP has established the cause of the wall bowing was subsidence which occurred more than 72 hours after the flood and/or storm event. Case No: 270421 Determination Page 7 of 8 37. The Applicant‟s engineer has concluded that the timber members are not bowed but rather that the gyprock cladding has come away from the wall frame. The engineer however has provided an opinion that the damage occurred during the January 2011 storms. In particular, the combined effects of heavy rain and cyclonic winds supplied sufficient vibration to allow it to shed the weakened gyprock material. Weather records have been referred to in order to support the engineer‟s conclusion. The wind scale suggests th e recorded winds would fall under the “strong wind” and “storm” wind categories. I consider that these weather events would fall under the policy definition of storm. The engineer also states that the prolonged exposure to high humidity would also have softened the gyprock wall. 38. I have considered whether the suggestion of humidity excludes the entire loss under the atmospheric exclusion. The engineer suggests the gyprock was softened, however it states that it was the heavy rain and cyclonic winds which caused the gyprock cladding to come away from the wall. It does not appear that the predominant cause of the deflection is humidity but rather high winds. Accordingly, I do not think the Wayne Tank rule would apply to exclude this entire loss. 39. I am not convinced that high winds would necessarily require external damage in order to cause internal damage. This phenomenon is frequently encountered in Victorian Storms whereby no external damage is caused but internal damage occurs (such as detaching ceilings) due to the internal pressures caused by high winds. Accordingly, I do not consider that proof of external damage is requisite to a claim for internal damage caused by high winds. 40. I have further considered the lack of information on topography and the effect this may have had on wind conditions. The only information is that the building is high set and the Applicant states that it faced prevailing winds. There is no evidence from the FSP firmly rebutting same and accordingly I must accept that the insured property was exposed to wind speeds up to 96km/hr. 41. I will now consider whether this incident falls outside of the policy definition of incident or event. The FSP has raised an argument regarding the possibility this event occurred over a nine day period and may not arise from a single event as required by its policy. 42. I have given some serious consideration to this argument. There are two potential dates listed as causing the damage, this being the storm which occurred over 9-10 January 2011 and the high winds on 18 January 2011. I note incidentally that storms may extend over several days. 43. It is foreseeable that the damage occurred during either storm event or alternatively was affected by both. However, I consider it more likely that the winds reaching 96km/hr caused the damage. There is potentially some prejudice caused to the FSP as the damage may have happened in both events. Given this, I consider it fair and reasonable to allow the FSP to charge two excesses to mitigate any prejudice caused to it. Case No: 270421 Determination Page 8 of 8 44. I have f urther considered the Applicant‟s request for reimbursement of the engineer report. The engineer report has provided crucial evidence regarding the cause of loss and accordingly I consider it appropriate for the Applicant to be reimbursed the cost of same. 45. The Applicant has also sought loss of rent and the policy does provide cover for loss of rent subject to terms and conditions. However, I am satisfied that the Applicant has not provided proper proof of the amounts and timeframes involved and accordingly I will refrain from making any order regarding quantum. Determination 46. On the basis of the available information I determine that the FSP was not entitled to decline the Applicant‟s claim. I further determine the FSP is entitled to charge the Applicant two excesses for this claim. 47. The FSP shall make payment of the repair costs, any appropriate loss of rent in accordance with the policy terms and interest from the date of claim declinature less the excess amounts. The Applicant must provide proper proof of any rental amounts he seeks reimbursement for to the FSP. 48. On the basis of the available information I determine the FSP shall reimburse the Applicant the cost of the engineer‟s report within 14 days of the Applicant‟s acceptance of this Determination.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.