Storm damage to garage retaining wall denied as gradual deterioration or faulty workmanship
Text of the determination
Case No: 264676 Determination Page 1 of 11
Case number: 264676
General Insurance - Domestic Insurance - Home Building - Storm - FSP
Decision - Denial of claim - Gradual deterioration - Faulty workmanship -
Section 46 of the Insurance Contracts Act 1984
29 August 2012
Background
1. The Applicant held a home building and contents insurance policy with the
Financial Services Provider (FSP) which was in force at the time of the loss.
The policy covered for accidental damage.
2. On 11 January 2011, the Applicant lodged a claim for storm damage to
garage walls following the severe weather events in Queensland.
3. The FSP denied the claim on the basis the damage was caused by lack of
maintenance and gradual deterioration, which are excluded from cover
under the policy.
4. The Applicant disagrees with this decision and argues the damage was
caused by the severe storms during the period of December 2010 – January
2011. He wants his claim paid in full.
Summary of Applicant’s position
5. In disputing the declinature of his claim, the Applicant has sought the
assistance of a legal representative. For the sake of clarity and brevity, both
the Applicant and his legal representative will be referred to as “the
Applicant” for the purpose of this Determination.
6. Between December 2010 – January 2011, Brisbane suffered constant and
heavy rains. About 4 January 2011, he realised water was seeping through
cracks in the garage walls and there were water puddles throughout the
floor.
7. In 10 years living in the property, he has never had problems of water
coming into the garage through the retaining walls.
8. The policy provides cover for storm, rainwater and wind. While these terms
are not defined in the policy, an ordinary reasonable consumer would
Determination
Case No: 264676 Determination Page 2 of 11
interpret them as including the severe Queensland weather events which
damaged his property.
9. The FSP’s loss assessor (N) inspected the damage, after which the FSP
rejected the claim on the basis of a pre-existing defect or lack of
waterproofing in the retaining wall.
10. At review, the FSP appointed engineers M to assess the damage. M, without
inspecting or going near the wall, said the damage was due to a pre-existing
defect. He showed M a structural inspection report done at the time the
house was bought, but M still said the damage was a maintenance issue.
11. The FSP declined the claim on the basis that damage was the result of a
defect or lack of maintenance. Section 46 of the Insurance Contracts Act
1984 (the Act) provides protection to consumers who were unaware of any
fault or defect when the insurance contract was entered into. In those cases,
the insurer cannot refuse a claim.
12. He was not aware of any damage to the garage walls before the claim
because there was no noticeable leak before the events in December 2010 –
January 2011.
13. There was nothing to alert him to inspect the garage walls and doors.
Furthermore, the garage was in satisfactory state following storm damage
which was paid by the FSP in 2004. At the time there was no obvious
cracking in the walls or floor of the garage.
14. He has provided a structural report done at the time he bought the house.
This report shows there were no pre -existing defects or lack of maintenance
in the property at the time it was purchased.
15. Further, he acted at all times as a reasonable person would. When he
bought the property, he made sure that the property was structurally sound.
He has taken all necessary steps to maintain the property; the FSP cannot
allege he failed to do this.
16. Under section 35 of the Act, the FSP has an obligation to clearly inform an
insured in writing whether the effect of a provision excludes cover. The
Corporations Act 2011 also requires “clear, concise and effective” disclosure.
The FSP relies on an exclusion it alleges was clearly communicated to him.
17. He first obtained insurance with the FSP through intermediary C in 2001. He
did not receive a copy of the Product Disclosure Statement (PDS) or an
explanation of any potential exclusions at the time he entered into the
contract. He assumed he had ordinary insurance cover.
18. He received the PDS well after the contract was agreed to.
19. Consequently, the FSP has not complied with its responsibilities under
section 35 of the Act to clearly inform him of the exclusion. Further, the
relevant exclusions were not drawn to the attention of the Applicant.
Case No: 264676 Determination Page 3 of 11
20. In February 2004, there were hea vy storms and they damaged other
retaining walls around the house. He lodged a claim and this was paid out,
allowing him to replace the retaining walls.
21. He relied on this misrepresentation by conduct to his detriment, to mean that
the policy covered him in the event of retaining walls suffering storm
damage. If he had not been induced to stay with the FSP, his property would
have been covered for the damage suffered.
22. The FSP should pay for its misrepresentation which has left him without
cover for this damage. The damages for this misrepresentation are equal to
the value of the damage to his garage.
23. Under the General Insurance Code of Practice, an insurer is required to be
open, fair and honest in their dealings with their customers. He feels the FSP
has fallen short of that standard and his claim was not handled in a fair,
transparent and timely manner.
Summary of FSP’s position
24. N first reported that the garage retaining wall had no waterproofing
membrane or it had been compromised. The FSP then denied the claim on
the basis of gradual deterioration, wear or tear and faulty design, which are
not covered under the policy.
25. At review it organised for M to assess the damage. M reported that the
cause of damage was the wall’s waterproofing which has gradually
deteriorated over approximately 30 years and now allows water to pass
through.
26. M said the rectification work to the retaining wall is a maintenance issue,
which is not covered under the policy. Accordingly, it confirmed the denial of
the claim.
27. It disagrees th at there are many inconsistencies in M’s report. The
information M has provided is consistent with the Applicant’s structural report
of 2001 and the conclusions are drawn based on M’s expertise.
28. The PDS must be read in conjunction with the insurance schedule to
understand the applicable cover. There is no alternative “ordinary insurance
cover”.
29. An insurance contract is an annually renewable contract. The FSP has sent
multiple copies of the PDS to the Applicant and he has acknowledged
receipt of these, prior to the damage being noticed.
30. Even if section 35 of the Act operated and standard cover were applicable,
gradual deterioration would not be covered and wear and tear would be
excluded from cover.
Case No: 264676 Determination Page 4 of 11
31. Section 46 of the Act does not provide protection against gradual or
progressive deterioration. Either way, it is not relying on a condition the
property had before the contract was entered into.
32. With regard to the previous claim paid in 2004, it notes that all claims are
assessed in regard to the contract, its circumstances and issues. The
Applicant’s argument that it is a misrepresentation by conduct is not valid.
33. The FSP relies on the following policy provisions:
“ Accidental Damage cover
If you have chosen Accidental damage Home Insurance, we will cover
your buildings or contents for any accidental loss or damage.
There are also a number of incidents we will cover under specific conditions.
There are listed on pages 17 to 20.
If you make a claim, you must pay any excesses that apply - you will only
need to pay this amount once.
Any cover we provide is subject to exclusions.
Incident cover provided under specific conditions
...
Storm,
rainwater or
wind
B UILDINGS
C ONTENTS
Under Accidental Damage, we will cover your buildings or
contents for loss or damage as a result of storm, rainwater
or wind.
...
We will NOT COVER
water entering your buildings
– because of a structural defect, faulty design or faulty
workmanship when your buildings were constructed
...
Exclusions to your cover
Any cover we provide is subject to the following exclusions.
Listed
Events,
Accidental
Damage,
Additional
cover and
Strata Title
Mortgagee
Protection
exclusions
We will NOT COVER any loss or damage as a result of, or
caused by
erosion, rust, corrosion, gradual deterioration,
depreciation , wear or tear
a defect in an item, structural defects, or faulty
workmanship or design
water entering your buildings
– because of a structural defect, faulty design or faulty
workmanship when your buildings were constructed . ”
Issues
34. Whether the FSP complied with its obligation under section 35 of the Act to
clearly inform the Applicant of the flood exclusion.
Case No: 264676 Determination Page 5 of 11
35. Whether the FSP, when it accepted a similar claim in 2004, represented to
the Applicant that it would cover any storm damage to retaining walls.
36. Whether the FSP is entitled to refuse the Applicant’s claim under the basis
the damage is due to gradual deterioration or pre-existing defect.
Reasons for decision
37. As advised to the parties, due to the nature of the dispute and the amount
claimed, the Financial Ombudsman Service (FOS) has considered it
appropriate to expedite the dispute to Determination in accordance with the
Operational Guidelines to the FOS Terms of Reference.
38. I am satisfied a full exchange of information has taken place between the
parties and each party has had the opportunity to address the issues raised.
39. I have reviewed the submissions of the parties and observe there is no
dispute that the garage walls and floor were water damaged. I will now
address each of the issues that have arisen between the parties.
Whether the FSP complied with its obligation under section 35 of the Act to
clearly inform the Applicant of the flood exclusion
40. The Applicant alleges he first obtained insurance cover through C and that at
that time he did not receive a PDS. He also says the FSP did not alert him to
the applicable exclusions. As such, he says standard cover should apply and
the FSP should pay for the claimed damage.
41. The FSP notes the Applicant has acknowledged having received the PDS
and that this PDS clearly informs the Applicant of the exclusions for gradual
deterioration, wear or tear, structural defects or faulty workmanship. It also
notes that standard cover excludes wear and tear and does not cover
gradual deterioration.
42. I note that the FSP is allowed under section 69 of the Act to provide
information in writing within 14 days after the day the contract was entered
into. I note the Applicant has conceded to having received the PDS.
43. Accordingly, I am satisfied on that basis that the Applicant was clearly
informed of the terms and conditions of the policy in compliance with section
35 of the Act. I note it is not an insurer’s obligation to alert potential
customers to specific exclusions that may or may not apply to their specific
needs.
Whether the FSP, when it accepted a similar claim in 2004, represented to the
Applicant that it would cover any storm damage to retaining walls
44. The Applicant contends he had a similar claim for storm damage to other
retaining walls paid by the FSP in 2004. He alleges that he has taken this to
Case No: 264676 Determination Page 6 of 11
mean that he would be cover for similar damage like in the instance of his
current claim.
45. He also says that he has been prejudiced in his ability to seek alternative
cover. He would have done so, had it been clarified that this type of damage
was excluded.
46. The FSP argues that each claim is decided on its issues, contractual terms
and circumstances.
47. I note that the Applicant has not provided any details of the circumstances of
his claim in 2004. I have found no evidence or basis to support an argument
in which when a claim is paid, all similar claims should be paid.
48. Unless it can be established the circumstances were exactly the same, I am
not convinced that the payment of a claim amounts to implying that all similar
types of claim will be paid. Each event that leads to a claim has different
circumstances, issues and different terms and conditions applied.
49. Accordingly, I am satisfied the FSP did not represent to the Applicant that his
current claim or similar claims for damage to retaining walls would be
covered.
Whether the FSP is entitled to refuse the Applicant’s claim under the basis the
damage is due to gradual deterioration or pre-existing defect
50. In these circumstances, the insured has the onus to establish on the balance
of probabilities that the claim falls within the definition of an insured event;
this is known as a prima facie claim. Once this is established, the onus then
shifts to the insurer to establish the application of any exclusion on which it
relies to deny or limit the claim.
51. The Applicant has alleged that the damage to the garage was caused by
severe storms. He argues that in the 10 years living in the property, he never
had issues of water seeping through walls in the garage and that a report
from 2001 indicates the garage did not have pre-existing defects.
52. The FSP argues that the damage was caused due to the garage retaining
wall’s membrane gradually deteriorating which has allowed water to pass
through. It contends this has likely happened because of the age of the
dwelling (30 years).
53. To support its position, the FSP has provided a report by loss assessor N
and engineers M. N’s report says in summary the following:
The house is approximately 30 years old.
The Applicant has lived at the house for the last 10 years and has
maintained the property and surroundings in good condition.
A puddle of water was on the concrete slab to the corner of the garage.
Paint has blistered and is falling off the block walls.
Case No: 264676 Determination Page 7 of 11
There is small cracking to the mortar, extending 1m to the right corner
of the back wall.
The garage acts as a retaining wall to the rear and to a pathway to the
right side of the garage.
Lime residue was noted to the exposed brickwork of the right side of
the garage, to the same level and pitch as the pathway.
Cracks were observed to the concrete slab, which indicates structural
movement over a long period of time.
Moisture readings to the rear wall were 22.9% at inspection time.
The damage to the rear wall has been caused as a result of water
seepage through the garage wall following a long period of rain. This
was caused due to no waterproofing or compromised waterproofing to
the retaining walls.
The cracking to the slab indicates structural movement.
The damage to walls and floors would not be short term water related
damage. The damage was due to an issue of building defect.
54. M’s report says in summary the following:
The building is a split level brick veneer dwelling. The garage is built
within the subfloor.
The perimeter walls of the garage act as retaining walls.
The northern wall shows progressive moisture ingress with paint
bubbling, peeling and blistering off the block surface. Salty staining and
residue (efflorescence) was observed on the block work suggesting
that ingress was continual and long term.
There is some minor hairline cracking within the mortar joints of the
northern wall. These are not considered structurally adverse.
The western wall has indication of moisture ingress with efflorescence
on the face of the brick work.
The concrete slab is a t raditional “slab on ground” built as an infill after
the construction of the garage walls. It does not have control joints.
The concrete slab cracking is running in both longitudinal and lateral
directions varying in width. No other sign of damage has been
observed. The suggested heave and undulation are not recognised.
In the external area, the northern and western walls have adjacent
concrete footpaths in excellent condition. Appropriate drainage has
been installed within the footpath. There is no evidence of cracking or
subsidence within the footpaths.
Visual inspection shows that failure within the waterproofing membrane
has occurred. The membrane is critical in the prevention of moisture
ingress through the porous masonry construction. In this case it has
either deteriorated or was applied incorrectly at the time of construction.
Case No: 264676 Determination Page 8 of 11
The installation of effective subsoil drainage behind a retaining wall
ensures that hydrostatic pressure is managed. Considering the
excellent sealed and drained footpath surfaces above the retaining
walls, water content within the retained soil must have permeated
within surrounding soil over time and not from above soil saturation
subsequent to the rain event.
Further, if moisture content of the retained soil increased rapidly due to
severe rainfall, then subsidence within the retain soil would occur,
causing cracking within the footpath slabs. This has not occurred.
The cause of damage to the perimeter walls is pre-existing defects
relating to deficiencies in retaining water proofing and drainage, which
has occurred progressively over time and not due to a single rain event.
The cracking to the northern wall is not structurally defining. The wall is
uncompromised and sound.
The damage to the concrete slab is superficial cracking most likely due
to plastic shrinkage cracking or lack of construction joints. However, the
visible cracks are superficial shrinkage cracks which are likely to be
caused due to poor construction practice and not a rain event.
The damage to the garage slab is not considered related to the event
as is viewed as a pre-existing construction defect.
It is accepted the severity and intensity of the moisture ingress may
have been exacerbated by the rain event, but it is not the cause.
55. In response to M’s report, th e Applicant has raised a series of
inconsistencies but has not presented any evidence to support these
allegations. Among the inconsistencies alleged, I consider the following of
most relevance:
There is no conclusive proof of deterioration or incorrect application of
a waterproofing membrane. The report prior to purchase of the house
shows there was no structural damage. Further, the water seepage has
only occurred after the severe rain events.
The cracking on the concrete slab and retaining walls is not s uperficial.
The upheaval on the concrete slab is clearly visible.
The house is located at a height and built on a slope. The topography
does not permit for water to be retained but rather drain away down the
slope. Every time water permeates through the soil, it has to be from a
rain event.
56. The FSP sought to respond to each of the Applicant’s concerns by referring
the Applicant’s letter to M. With regard to the main inconsistencies I’ve
noted, M replied the following:
The report obtained in 2001 is a standard building inspection report.
The minor cracking within the retaining wall is not considered structural
damage and would not be noted in that report.
Case No: 264676 Determination Page 9 of 11
The retaining wall at present is not structurally deficient, only has a
deficient waterproofing membrane system. The fact that seepage only
occurs after rain events confirms the deficiencies of the membrane.
The Australian Standard AS 2870.1 Residential Slabs & Footings is
used as a reference for identification of crack severity and size. As
such, cracking observed in the concrete slab is superficial and non
detrimental to the structure.
With reference to the Guide to Standards & Tolerances 2007 , a floor
level is considered defective if it departs more than 40mm. This is not
present in the concrete slab in question and therefore is not considered
an upheaval defect.
Moisture within the soil is ever present in differing moderation and
content. Regardless of topographic factors, surface water will saturate
into subsurface and permeate.
Levels of water content will change due to dry periods or rain. The
fluctuations in moisture content are causes of subsidence and
movement.
The moisture ingress is indicative of progressive issues relating to the
moisture containment behind the wall and deficiencies in the
waterproofing membrane.
57. I note the Applicant has noted other inconsistencies in relation to M’s report.
However, without any expert evidence to support his position, I am not
convinced that the Applicant’s concerns are valid.
58. In the absence of evidence to the contrary, I am satisfied the expert
evidence available strongly indicates that the damage was caused by either
gradual deterioration or faulty workmanship, both of which are excluded
under the policy.
Section 46 of the Insurance Contracts Act 1984
59. Section 46 of the Act provides that if a claim is made in respect of a loss that
occurred in whole or in part as a result of a defect or imperfection in a thing
and the insured was not aware of the defect or a reasonable person in the
circumstances could not be expected to have been aware of the defect or
imperfection, the insurer may not rely on an exclusion clause that refers to
the condition of the thing before the contract was entered into.
60. The Applicant contends that, since he purchased the house, he has done
everything reasonable to maintain it in good condition.
61. The Applicant alleges he did not know there could have been a defective
waterproofing membrane and he relies on a report he obtained when he first
purchased the house in 2001. This report says of the ga rage “Car
Accommodation – No Visible Defect”.
Case No: 264676 Determination Page 10 of 11
62. The Applicant relies on section 46 of the Act to say that he was not aware of
the defect prior to entering into the contract of insurance and for that reason
the FSP should not be able to rely on the exclusion clause.
63. The FSP alleges that section 46 of the Act does not apply to damage arising
from gradual deterioration. The FSP has quoted Greg Nelson v The Hollard
Insurance Company Pty Ltd [2010] NSWSC 199 (Nelson v Hollard) to
support its position.
64. The report the Applicant relies on says “This report has been prepared solely
from the visual inspection of the property concerned without the removal of
external or internal linings, roofing, flooring and soil.”
65. In my view, the Applicant would not have known of a potential waterproofing
membrane issue from reading the report he relies on.
66. Considering the damage would not have been readily visible unless a hole
was opened in the wall, I accept the Applicant or a reasonable person could
not be expected to have been aware of any potential issues of the
waterproofing membrane at the time the contract was entered into.
67. As noted in Nelson v Hollard, sub-section 46(2) of the Act only applies to
exclusions that have a temporal aspect. That is, it only applies to a clause
that makes reference to a defect or imperfection that existed before an
insurance contract was entered into. It does not apply to exclusion clauses
that seek to exclude liability for defects generally.
68. The FSP alleges that the damage was caused by gradual dete rioration. The
policy exclusion for gradual deterioration has a general application and the
Applicant ’ s lack of knowledge of gradual deterioration would not assist him in
that case.
69. However, M’s report, on which the FSP has based its denial of the claim,
says that gradual deterioration could have been caused by the waterproofing
membrane failing over time (gradual deterioration) or the incorrect
application of the waterproofing membrane leading to failure over time (faulty
workmanship).
70. The policy exclusio n for faulty workmanship has a temporal aspect (“We will
not cover ... water entering your buildings ... because of a structural defect,
faulty design or faulty workmanship when your buildings were constructed )
[emphasis added].
71. In this case, section 46 of the Act would respond if it can be determined that
the cause of damage was solely due to faulty workmanship. In such case it
could be argued that, due to the temporal aspect of the exclusion, the
Applicant receives the protection of section 46 and his claim should be paid.
72. That said, I am not satisfied that the evidence before me is sufficient to
establish on the balance of probabilities that faulty workmanship was the
sole cause of damage.
Case No: 264676 Determination Page 11 of 11
73. Further, it is unlikely that the faulty installation of a waterproofing membrane
would be the sole cause of damage approximately 30 years after being
installed. Had faulty workmanship been the sole cause of damage, the
damage would have occurred much earlier.
74. It is my view that the circumstances of the loss and the timing of the damage
are more consistent with damage due to gradual deterioration, which is more
likely to occur after a protracted period of time.
75. Even if I were to consider that gradual deterioration operated concurrently
with faulty workmanship to cause the damage, the claim would still be
defeated under the Wayne Tank principle (where a loss has two or more
proximate causes, and at least one of them is excluded from cover, the
insurer is not liable to indemnify).
76. For the reasons mentioned, I am satisfied tha t the FSP is entitled to deny the
claim.
Determination
77. On the basis of the available information, I determine that:
The FSP complied with its obligation under section 35 of the Act to
clearly inform the Applicant of the flood exclusion.
The FSP did not represent to the Applicant that it would cover any
damage to retaining walls.
78. Further, I determine the FSP is entitled to refuse the Applicant’s claim under
the terms and conditions of the policy.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.