Text of the determination
Case No: 264500 Determination Page 1 of 12
Case number: 264500
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of Claim - Exclusion/Condition
19 June 2012
Background
1. The Applicant held a home and contents policy with the FSP for many years
with the FSP confirming the policy covering the claimed event was incepted
on 23 January 2011 and was current at the time of loss.
2. On 24 March 2011 the Applicant contacted the FSP to report rainwater/storm
damage to the insured property as having occurred on 8 February 2011.
3. The FSP appointed an Assessor, P, to confirm the cause and extent of
damage. The Applicant paid the applicable policy excess on being advised
his claim had been accepted.
4. The FSP says the Applicant was advised wear and tear, deterioration, faulty
design and workmanship issues were not covered. The Applicant denies
being told this information until after he submitted a quotation from a builder
he had arranged to effect repairs.
5. After a number of builders, building experts, quotations for repairs and
complaints made by the Applicant, the FSP officially declined all
maintenance, wear and tear and structural defect issues with the property. It
advised the Applicant to attend to these issues at his own cost and it would
then attend to the relevant rainwater damage to the property, which they
accepted.
6. The Applicant disputes this decision saying the FSP‟s own experts informed
him and provided reports indicating some aspects of the building failed due
to the storm of 8 February 2011 and not as a result of any maintenance,
wear and tear or structural defect issues.
Summary of Applicant’s position
7. The Applicant says his residential property suffered significant rainwater
damage during a storm in February/March 2011. He reported the matter to
Determination
Case No: 264500 Determination Page 2 of 12
the FSP and made the property available for inspection by the FSP‟s
assessors/experts.
8. After numerous inspections by the FSP‟s appointed builders and experts, the
Applicant was informed the FSP would pay for the cost to repair the resultant
rainwater damage however there were a number of maintenance related
issues which required the Applicant‟s attention.
9. The Applicant disputed the rainwater entering his premises through any
other means other than openings created by the storm he had reported to
the FSP.
10. The Applicant is seeking to have his property restored to a position it was
prior to the storm of 8 February 2011 which he says had no leaks and no
rainwater damage.
Summary of FSP’s position
11. The FSP received advice of the Applicant‟s storm damage claim on 24
March 2011 and appointed an Assessor to inspect the damage.
12. As a result of the expert reports received, the FSP advised the Applicant of
the maintenance related issues at the Applican t‟s property. The FSP advised
the Applicant to have the maintenance issues fixed and at that time, they
would authorise the repairs for the resultant rainwater damage.
13. The FSP referred the matter to further experts after the Applicant advised it
that there were no issues with the property prior to the storms and he firmly
believed the damage was all storm related.
14. The FSP upheld its decision after receiving further expert advice. It believes
the Applicant‟s property is in need of maintenance related repairs to prevent
further damage and to enable it to affect the relevant rainwater damage
repairs.
15. The FSP relies on the following policy provisions in accordance with its
Product Disclosure Statement (PDS):
“ What we cover – insured events ...
You are covered for damage or loss to your home building occurring
during the period of cover and caused by the following events: ...
Storm and rainwater including stormwater runoff from areas surrounding the
site, or water escaping from any water main, drain, pipe, street gutter,
guttering or surface.
Storm means violent wind (including a cyclone or tornado),
thunderstorm or a heavy fall of rain, snow or hail.
...
You are not covered for: ...
Case No: 264500 Determination Page 3 of 12
Damage or loss caused by water seeping into or otherwise entering your
building due to:
a defect or fault in the design, structure or construction of your building
where you could reasonably be expected to be aware of the defect or fault,
building alterations, renovations or additions ... ”
(Pages 8-13)
“ What we do not cover – general exclusions
You are not covered under any section of the policy for damage, loss,
cost or liability caused by or arising from or involving: ...
an unreasonable failure to properly maintain or repair your building,
wear and tear, rust, deterioration or corrosion,
mechanical, structural, electrical, electronic or other failure or breakdown,
other than as provided for under „Damage to electric motors‟ on page 22,
... ”
(Page 14)
“ What we will pay – new for old
...
Repairing your building
When we establish that your home building can be properly repaired, we will
decide to:
repair it, or
pay the cost of repairing it.
When we repair your building, we will use new materials.
We will make reasonable endeavours to match materials. Where this does not
achieve an exact match, materials that in our opinion match the damaged or
lost materials as near as reasonably practicable will be used. We will not pay
to replace undamaged materials or any undamaged part of them to achieve a
match.
...
Damage to fixed wall or floor coverings
When we repair or replace damage to fixed wall, ceiling or floor coverings:
we also repair or replace undamaged coverings if this is reasonably
required to achieve a match with the repair or replacement of the damaged
area,
the repair or replacement is limited to the room, passageway, stairwell
or functional area where the damage occurred.
Fixed wall and floor coverings are items such as tiles, floating floors, fixed
cupboards and shelving.”
(Pages 17-18)
Case No: 264500 Determination Page 4 of 12
Issue
16. Whether the FSP is required to indemnify the Applicant for the cost of
structural repairs as described by the Applicant.
Reasons for decision
17. Due to the nature of the dispute, FOS has considered it appropriate to
expedite the dispute in accordance with the Operational Guidelines to the
FOS Terms of Reference. This dispute has not been the subject of a FOS
Recommendation and has proceeded directly to Determination.
18. I am satisfied that a full exchange of information has taken place between
each party and that each party has had the opportunity to address any
issues raised.
19. The Applicant says he and his wife have been loyal customers of the FSP for
many years. They have a number of policies with the FSP and have never
made any at fault claims. The property the subject of this claim was built by
the Applicant‟s builder in circa 2001.
20. During the night of a storm in February 2011, the Applicant was awoken by
the sound of banging on his balcony. He went outside and saw a glass panel
of the stairwell hanging off and he removed this glass panel to safety, inside
the house.
21. The Applicant says his home suffered various areas of rainwater damage
which he believed had been caused as a direct result of storms in
February/March. Prior to this time there had been no leaks or damage from
rainwater or storm.
22. The Applicant says after contacting the FSP to report the claim, it appointed
P to inspect the damage and was advised by P the damage sighted was all
storm related. The FSP subsequent to P‟s attendance advised the Applicant
his claim was accepted and he would need to pay his policy excess to
enable repairs to be effected. The Applicant paid the excess as he was keen
to have repairs effected as soon as possible to prevent further damage
occurring in the ensuing winter months.
23. The Applicant s ays he was not advised the alleged “cause” of the rainwater
entering his home would not be covered by the FSP until after he submitted
a quotation from a local builder who he intended to use as they provided a
different building material which would limit future rainwater entry. He says
the FSP informed him there were wear/tear/maintenance issues which
allowed rainwater to enter the property and he would have to attend to these
repairs prior to the rainwater damage being repaired.
24. The Applicant disputed the cause of the water entry as alleged by the FSP
and the FSP appointed another builder, J, to provide an expert opinion on
the cause of damage. The Applicant says J did not get onto the roof of the
Case No: 264500 Determination Page 5 of 12
property despite advising the Applicant a possible cause of the rainwater
entry was due to box gutters and drainage gutters.
25. The Applicant offered to show J a copy of the certificate showing
waterproofing for the deck area of his property was completed at the time of
building the property however J advised him it was not necessary.
26. The Applicant says he was informed by the FSP they would be arranging
another assessment by A. During A‟s attendance he told the Applicant his
company was only able to conduct tests to and inspection of the deck leaks.
He was able to located several leaks coming from the deck however was
unable to detect the cause of a leak in a guest bedroom.
27. The Applicant appointed an independent builder, N, to inspect and report on
his findings of the extent and cause of damage. It was N‟s opinion the
damage he sighted was caused by storm and without further destructive
investigation, causes for some of the leaks, could not be accurately
determined.
28. The Applicant says the FSP has alleged “possible” causes of the damage
and relied on these to deny his claim for repairs to the deck. N has provided
alternative possible causes for the damage which indicate storm damage
only and as such, the Applicant believes he has a valid claim.
29. The FSP appointed another expert, S, to re-assess the damage and cause.
S provided a series of photographs to support his findings. The Applicant
says these findings again refer to possible causes and allege maintenance
issues on others where his builder clearly advised there was no fault.
30. The FSP after reviewing the reports received from their appointed experts
and the Applicant‟s expert, agreed to cover damage to the stairwell/railing,
which they had previously denied. The Applicant says the FSP continued to
deny the structural repairs, in particular the repairs required to the deck
waterproof membrane, on the basis of possible causes advised to it by their
experts.
31. The Applicant indicates the initial assessments and quotations for repairs
arranged by the FSP were done around March 2011. The Applicant
arranged his quotation in May 2011. He did not hear from the FSP until he
called it in July 2011 to query the claim. At this point, the further
assessments were arranged both by the FSP and the Applicant. The
Applicant received the first denial letter in August 2011, approximately 6
months after the storm event.
32. Throughout this time and since lodging his original dispute with the FSP, the
Applicant says he and his wife have had buckets scattered around their
house to catch any rainwater leaks from further rains. There is also a strong
smell of mildew and the Applicant believes their health is being affected by
the current unrepaired condition of their home.
Case No: 264500 Determination Page 6 of 12
33. The Applicant has also raised a number of concerns regarding the apparent
lack of communication from the FSP unless initiated by him, their backdating
of letters to him and their general lack of customer service.
34. The FSP confirms receipt of a claim notification from the Applicant on 24
March 2011 relevant to a storm event of 8 February 2011 and early March
2011. The FSP says it advised the Applicant wear, tear, maintenance, faulty
workmanship was a policy exclusion and not covered under the policy during
a telephone discussion with the Applicant on 25 March 2011.
35. The FSP appointed P to assess the damage. He provided a number of
photographs of the affected areas and a scope of works for the required
storm damage related repairs. The scope of works did not include repairs to
ceilings in the bedroom/study, living areas and bathroom ensuite, wall
damage to the bathroom/ensuite and external s tructures.
36. P included painting of ceilings in the garage, bedrooms 1, 2 and 3, a bar
area, den, family room and external ceilings to patio areas at the southern
end of the property, as requiring repairs. Quotations for this work were
obtained from two bui lding contractors for $9,967.76 (D) and $8,701.75 (T).
The quotations were dated 9 May 2011 and 4 May 2011 respectively.
37. The FSP agrees the Applicant contacted it on 19 April 2011 expressing his
desire to use a different type of building material and it requested the
Applicant to forward the quotation. The quotation from B was dated 3 May
2011 and forwarded to the FSP on 25 May 2011. The quoted amount was
$89,100.
38. The Applicant also indicated at this time floor tiles for the deck were no
longer available and suggested all tiles would require replacing to match
style, size and appearance.
39. The FSP received a call from the Applicant on 7 June 2011 querying the
progress of the claim. The FSP informed the Applicant another assessment
was required due to the discrepancy in quotations. The FSP file notes
indicate the quote from the Applicant‟s builder included the replacement of
tiles which had not been identified as being damaged.
40. The FSP appointed J on 9 July 2011. J‟s report is dated 15 July 2011 and
concluded some rainwater had entered through design faults/faulty
workmanship, possible roof design issue, gutter overflows, storm system
being unable to cope with the storm event, failure of waterproofing to the
tiled balconies (deck), movement in the stair stringer and other areas of
damage having an “unknown” cause. J also provided a series of
photographs.
41. The FSP appointed A on 2 August 2011 to attend to determine the cause of
the leaks to the deck area. A‟s report was received on 5 August 2011 and
concluded grout had broken away and tiles had broken in the tiled deck area
due to water damage, water leaking to the membrane is overflowing and
passing through weak points to the ceiling below and a further leak to a
Case No: 264500 Determination Page 7 of 12
bedroom could not be determined, however A offered an opinion on this
leak. A suggested the leak was from the balcony/deck area, tracking to roof
insulation which becomes waterlogged which in turn leaks through to the
ceiling.
42. In his report, A suggested investigation was needed to confirm this leak to
the bedroom and to the study.
43. The findings were advised to the Applicant on 11 August 2011 when he
called to follow up on the claim. A letter was sent to the Applicant on 17
August 2011 (dated 11 August 2011) formally declining part of his claim as
detailed in the assessment reports received.
44. The FSP received a complaint from the Applicant on 30 August 2011 and an
internal dispute was recorded. A review by the FSP‟s IDR process resulted
in the FSP maintaining its stance on repairs with the exception of accepting
cover for the stairway/balustrade.
45. The Applicant was still not satisfied with the FSP‟s position and after
contacting the FSP on 23 September 2011 the FSP appointed an expert, S,
to attend to provide another report. S was appointed on the same day to
attend urgently.
46. S‟s report dated 5 October 2011 provided a comprehensive inspection and
concluded the majority of damage claimed had been as a result of rain water
entering through either design faults, inadequate guttering/drainage items,
normal wear and tear, occurring over a period of time or the failure/absence
of waterproofing (deck). In addition, he added some damage had been
exacerbated by the storm event. He also provided a series of photographs, a
scope of works for “claim” related damage and a scope of works for
“maintenance” repairs.
47. Based on this report the FSP maintained its previous decision and provided
a copy of S‟s report and scopes of work, requesting the Applicant attend to
the maintenance related repairs. The letter to the Applicant is dated 16
January 2012.
48. There is no dispute that the Applicant has suffered extensive rainwater
damage to several internal and external areas of his home. The dispute
relates to the cause of the rainwater entry and whether the cause or causes,
as the case may be, relate to storm/rainwater damage, and one event or
over a period of time.
49. The onus of proof rests on the applicant to establish that, on the balance of
probabilities, he has suffered a loss caused by an insured event. Once the
applicant has established that the loss was caused by an insured event
under his policy, the onus then shifts to the FSP to show that, on the balance
of probabilities, the loss falls within an exclusion of the policy.
Case No: 264500 Determination Page 8 of 12
50. I am satisfied the Applicant has shown he has suffered a loss caused by an
insured event, namely storm, in this instance. His expert advice provided by
N shows N‟s opinion as being the cause of damage as storm.
51. I am not satisfied the FSP has adequately demonstrated the damage has
been caused by an excluded event under the policy. Its expert evidence is
ambiguous, incomplete and contradictory and I find it difficult to support the
FSP‟s decision based on its expert evidence.
52. Of concern is the absence in any of the expert evidence provided by both the
Applicant and FSP, of any definitive cause of water entry via the deck. The
FSP expert, S, whose report the FSP appear to have relied upon in their final
decision, with respect to the deck, says:
“ I am of the opinion that the failure to install intermediate movement joints at
the appropriate locations has caused the floor tiles of the balcony to crack.
Therefore I consider this to be defective building work.
I also observed skirting tiles beneath some of the door and window openings
leading out on to the balcony. However no skirting tiles were observed to the
balcony floor and wall junctions. The use of skirting tiles to the floor and wall
junctions of a balcony is usually utilised to conceal the presence of the
waterproofing to the floor and wall junction.
I observed that the tiled floor and wall junctions to the balcony were sealed
with flexible sealant.
I am also of the opinion that the water ingress and damage to the ceiling and
wall linings to the master bedroom, sauna, guest bedrooms one and two, the
downstairs family room and the underside of the balcony is due to the failure
or absence of the waterproofing system to the balcony. As ceramic tiles are
considered water resistant and not waterproof this has allowed moisture to
penetrate through the tiles and grout to the balcony floor substrate. This in
turn has resulted in water breaching the waterproofing system and allowed
the same to seep through the substrate, enter the ceiling cavity and eventually
deposit on the ceilings and walls below.
Therefore I consider this to be defective building work and not the result of the
storm event.”
53. Whilst this opinion describes how water can seep through floor tiles and
grout given the nature of their design/materials, and confirms a waterproof
membrane must be installed beneath the tiles to prevent water ingress, it
has not confirmed whether the waterproof membrane exists or has failed. If
the membrane has failed, there is no explanation provided as to how this has
occurred and therefore, the FSP has not proven, on the balance of
probabilities, the membrane has not been damaged as a result of the storm
event and subsequently failed.
54. The Applicant‟s expert, N, agrees there is some minor cracking to tiles and
grout in this area, something all experts have commented on. However N
indicates grout is a pervious material and will therefore always allow water
in, necessitating a waterproof membrane under the tiled area. This opinion
appears to echo that of S. N also says that:
Case No: 264500 Determination Page 9 of 12
“This would not compromise the efficiency of the waterproofing as th e
membrane operates separately to the tiles and grout. ..........
I believe in this situation where an extreme deluge of water and high winds
occurred, the decking box gutter could have overflowed, and water was forced
(by wind) between the balcony and floor joists, where it is then capable of
tracking along a floor joist or framework to appear at different location(sic).
There are many possibilities however that may be contributing to the leaks,
which have to be investigated. Basically the ceiling plaster will need to be
removed to determine the true problem (other possibilities include, sliding
door window jambs on the above floor, or through the wall connections or
through the roof- although I saw no evidence of roof damage).”
55. One issue the experts have agreed on is to determine the exact cause of the
damage emanating from the deck would involve destructive investigation.
This should show the exact cause of the leak and show whether a
waterproof membrane was in place, if it has failed and the cause of the
failure.
56. It should be noted this loss occurred in February 2011 and therefore any
inspection at this point should take into account additional rainfall
experienced in the region since that time which could have contributed to
any deterioration already present, whether maintenance related or caused
by the storm event.
57. Other contradictions as expressed by the FSP‟s expert S include the
inadequacy of box gutters, guttering and drainage in other areas of the
house. Despite this comment, S summarises
“ Summary ...
I am of the opinion the damage in the study and built-in cupboard is primarily
due to the absence of an overflow to the box gutter, however this has been
exacerbated by the storm event experienced in the region at the time.
I am of the opinion the damage to the ceiling around the speakers in the
upstairs entertainment room is due to the incorrect installation of the capping
to the box gutter. It is also my opinion that this has been exacerbated by the
storm event experienced in the region at the time. ”
58. From this opinion, it could be said, had the storm not occurred, the damage
may not have occurred. The Applicant‟s view is no damage similar to what
he is now claiming has ever occurred at the property in the past. This is
supported by his expert‟s comments:
“... And, as mentioned earlier- it is unlikely that all the problems surfaced
simultaneously – without a common cause (i.e. severe storm). ...”
59. To support this view further, it has been well documented that the Melbourne
area underwent unusually heavy rainfall periods throughout 2010,
culminating in severe storms in February/March 2011, the most significant of
which occurred on 8 February 2011 . I find it difficult to accept the FSP‟s
stance that the rain has entered the Applicant‟s property during the F ebruary
2011 storm due to structural defects, wear and tear, faulty design etc. If this
Case No: 264500 Determination Page 10 of 12
was the case, why was rainwater entry not evident at the property during the
preceding months of heavy rainfall, throughout 2010?
60. Another area of concern is the FSP‟s e xpert advice regarding a leaking
window where S advises flashing is absent. In the Applicant‟s expert opinion,
N advises he could see no obvious areas of concern with flashing or with the
window installation, which had been alleged by J in his report.
61. Photographs provided by the FSP experts show the resultant damage and
photographs provided by S show guttering referred to in his report. I have
carefully considered all the photographs and I am of the opinion that the
rainwater damage described is recent.
62. S has provided only one photograph of evidence of cracked floor tiles and
grouting to the deck area, whilst more extensive photographs provided by J
do not clearly identify any cracks or tiles or grout, in the same area.
63. There have been a number of areas of damage where the cause has not
been identified, rather experts have relied upon possible causes only.
64. It should be remembered the Applicant‟s expert attended the site sometime
between 30 August 2011 and 16 September 2011, in excess of 6 months
after the storm event and after significant further rainfall was experienced in
the region. The FSP‟s expert S attended the property on 30 September
2011, almost 8 months after the storm event.
65. I am satisfied the FSP has accepted the damage to the stairway and
balustrade as storm related damage and has agreed to repair this area.
66. I believe further investigation needs to be undertaken in order to finally
determine the cause of the water entry.
67. I believe it only fair in the circumstances that both the Applicant and FSP
contribute equally to the costs associated with determining the exact cause
and an expert agreeable to both parties be used to facilitate this exercise.
68. After the completion of this exercise, I believe it is only fair that should it be
found the waterproofing membrane shows evidence of damage, then such
damage would be attributed to the storms, and due to the time elapsed since
the storm event. In those circumstances the FSP should attend to the repair,
or if necessary, the replacement of that waterproofing membrane and shall
bear all of the costs of the investigation. All subsequent damage to effect
repairs/investigation to the deck, should also be borne by the FSP.
69. If, on the other hand, there is no waterproofing membrane in place or it can
be proven on the balance of probabilities the membrane has deteriorated
through a cause excluded by the policy, then the costs of the replacement of
the membrane and subsequent damage to effect repairs/investigation to the
deck, must be borne by the Applicant.
Case No: 264500 Determination Page 11 of 12
70. With respect to subsequent damage to the deck, it is noted tiles may need to
be replaced if damaged through the investigation process.
71. The Applicant has advised replacement tiles matching existing tiles are no
longer available, in which case, in accordance with Pages 17-18 of the
FSP‟s PDS, the FSP should replace all floor tiles to the “functional area
where the damage occurred”.
72. The same attitude must be applied to other contentious issues, namely leaks
through or around windows, given the contradictory evidence provided by
the experts.
Determination
73. I determine the area of the dwelling on which the water entry has occurred
relevant to the decking, must be investigated, by destructive or other means,
in order that the exact cause of the water ingress can be determined. The
Applicant and the FSP shall be initially equally responsible for the costs of
the investigation and need to agree on the contractor engaged to conduct
this investigation.
74. In the event the waterproofing membrane is confirmed as being damaged by
storm, I determine the FSP shall meet the costs of repairs or replacement of
the membrane and all subsequent repair costs to reinstate the deck and
other property due to investigative works/damage and shall meet the
investigation costs in full.
75. If upon examination it is determined the waterproofing membrane has failed
for a reason excluded under the policy, the Applicant shall meet the costs of
the investigation and the costs associated with installing a new membrane.
76. I determine further investigation needs to be undertaken with respect to
leaks around windows to again prove without doubt the cause of the water
ingress. I determine that the Applicant and the FSP shall be initially equally
responsible for the costs of the investigation and need to agree on the
contractor engaged to conduct this investigation.
77. In the event the cause of the damage is found to be caused by storm or
another insured event, I determine the FSP shall meet the costs of repairs or
replacement of the affected areas, and shall meet the investigation costs in
full.
78. If upon examination it is determined the damage has been caused by a
reason excluded under the policy, the Applicant shall meet the costs of the
investigation and the costs associated with rectifying the cause.
Case No: 264500 Determination Page 12 of 12
79. In all cases, once all causes have been rectified and repaired to the
Applicant and FSP‟s satisfaction, the FSP will effect repairs to all areas of
rainwater damage and the stairway/balustrade, as previously accepted.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.