Home / Financial Firm (Unknown - Insurer) / Determination 264004

Determination 264004

Denial of claim

FirmFinancial Firm (Unknown - Insurer)
Decided2012-08-23
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's storm claim for internal ceiling and wall damage was denied under the wear, tear, gradual deterioration and defective workmanship exclusions. AFCA found the roof sheeting's poor condition and prior similar water entry showed the damage was not caused by a single storm, and determined the FSP is entitled to deny the claim.

Where a prima facie storm claim is established, the insurer may rely on the general exclusions for gradual deterioration and maintenance failures if the evidence shows those caused the damage.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 264004 Determination Page 1 of 8 Case number: 264004 General Insurance - Domestic Insurance - Home Building - Storm - FSP Decision - Denial of claim - Exclusion / condition 21 August 2012 Background 1. The Applicant held a home building insurance policy with the Financial Service Provider (FSP), which was in force at the time of the loss. The policy covered for defined insured events. 2. On 7 January 2011, the Applicant lodged a claim for storm damage to the internal walls and ceiling linings of the kitchen, lounge and dining areas of his house. 3. The FSP denied the claim on the basis that the cause of damage was due to wear and tear, gradual deterioration and defects in design and workmanship, all of which are excluded under the policy. 4. The Applicant disagrees with this decision and argues that the damage was caused by storm. He wants his claim paid in full. Summary of Applicant’s position 5. He had noticed water entering through the ceiling only on two previous occasions. Those two times, the downpipes were covered with floodwaters and the amount of water that entered the house was significant. 6. The cracks in the plaster ceiling prior to the last downpour were only hairline cracks along the joints, now they are large and visible. 7. The contractors that put the insulation in the roof told him it was in good condition save for the gutters. These contractors removed, put back in place and re-screwed the roofing iron down. 8. The FSP’s building expert ( S) says his house was built in 1965 and that the pitch of the roof is too low according to manufacturer standards applicable since 1963. 9. However, S has only estimated the year of built, the property could have been built before the standards change. Further, had the roof pitch not been Determination Case No: 264004 Determination Page 2 of 8 right, it would not have been approved by the city council. If the FSP was concerned about this, he questions why it offered insurance in the first place. 10. There have been many storms since he bought the property in 2008 but there had been no water entering the house. His main residence and his other house have the same type of roof and have had no water entering the building. He wants the FSP to repair the damage to his property. Summary of FSP’s position 11. Its loss assessor (C) engaged S to report on the cause of damage. At the time of the FSP’s response the Applicant had not provided any expert evidence to support his position that the damage was caused by a storm event. 12. It disagrees that there was allegedly no failure to rectify the external defects to the roof just because the internal water damage had not been evident prior to the storm event. 13. On the contrary, S confirmed that the external roof covering was in a poor and deteriorated condition prior to the storm and had been like that for an extended period of time. 14. It has been clearly established that the damage was not caused by storm but by wear and tear, defects in design and workmanship, gradual deterioration and maintenance issues, which are excluded from cover under the policy. 15. With regard to section 46 of the Insurance Contract Act 1984 (the Act), the FSP contends that said section of the Act does not provide any protection to the Applicant. This section applies only to “defects” whereas in the claim both defect and maintenance related issues caused the damage. 16. Upon purchase of the policy, the Applicant informed the FSP that the property in question was built in 1970. The FSP recorded and relied on this information when providing insurance cover. 17. A property title search has been obtained which supports its position that the property was built between 1970 and 1974. The FSP is entitled to rely upon the building standards in force at the time of the property’s construction. 18. It is not the FSP’s responsibility to carry out pre-insurance application inspections of all properties it insures. 19. The FSP relies on the following policy provisions: “ 2. General exclusions. We do not insure you for any loss or damage that is caused by or arises from:  defects in design, structure, materials or workmanship  wear and tear, gradual deterioration, or fading Case No: 264004 Determination Page 3 of 8  rust, corrosion, oxidisation, mould, mildew or atmospheric conditions  failure to keep the property insured in good condition ... 3.4 Residential Home and Contents Insurance insured events. We will insure your building and contents at the site against loss or damage caused by the following events if they occur during your period of insurance. Storm We will cover Loss or damage caused by storm, including cyclone, hail, wind, snow or rain. We won’t cover  loss or damage caused by or resulting from: – gradual deterioration from rain – rain entering the buildings because of poor maintenance, or where windows, doors or openings are not closed ... 8.4 How we settle your claim. We will not pay a claim for an event when:  the claim is excluded by specific policy exclusions or by any of the general exclusions listed on page 13 ” . Issue 20. Whether the FSP is entitled to deny the Applicant’s claim under the terms and conditions of the policy. Reasons for decision 21. As advised to the parties, due to the nature of the dispute and the amount claimed, the Financial Ombudsman Service (FOS) has considered it appropriate to expedite the dispute to Determination in accordance with the Operational Guidelines to the FOS Terms of Reference. 22. I am satisfied a full exchange of information has taken place between the parties and each party has had the opportunity to address the issues raised. 23. I have reviewed the parties’ submissions and observe there is no dispute that internal walls and ceilings are water damaged. The central issue in dispute is whether the cause of damage is covered under the policy. 24. In these circumstances, the insured has the onus to establish on the balance of probabilities that the claim falls within the definition of an insured event; this is known as a prima facie claim. Case No: 264004 Determination Page 4 of 8 25. Once that is established, the onus then shifts to the insurer to establish the application of any exclusion on which it relies to deny or limit the claim. 26. The Applicant argues the damage was caused by storm and this is corroborated by the water damage to the internal walls and ceiling. He contends that this has only happened after the storm event of 6 January 2011. The FSP does not dispute there was a storm on that date. 27. In the light of the information provided and considering there is no dispute that a storm occurred on the alleged date of the loss , I am satisfied that the Applicant has established a prima facie claim for storm damage. 28. With regard to the application of an exclusion, the FSP says that the cause of damage was wear and tear, gradual deterioration, defects in design and workmanship and maintenance related issues. 29. The Applicant says no internal damage had occurred in the past which could have made him aware of any issues with the roof. He also says that the roof pitch adhered to building standards for the time the house was built; otherwise, the city council would not have approved the construction. 30. To support its position, the FSP has provided a report from S, which says in summary the following:  The property is a freestanding, elevated split level, fibrous cement sheet, corrugated metal roofed building constructed on a timber bearer and joist floor. It is situated at a height similar to the street frontage.  The property is approximately 45 years old and is in fair condition for its age.  The Applicant indicated that water entry has occurred before but that the crack damage has become more pronounced after each entry.  Guttering on the kitchen side of the home appeared extremely rusted and deteriorated.  The plaster ceilings in the kitchen and lounge room were in poor condition with visible cracks along the joints of the sheets. The paint was also in poor condition and was blistered and peeling away from the ceiling sheets over their entire surface.  Water stains were visible on the eastern wall of the kitchen where the lower section of the split level residence abuts the higher level.  The external roof area has galvanised corrugated metal roof sheets rolled over the ridge of the roof in one continuous length. The metal roof cover is generally not in a good condition.  Approximately 20% of the roof sheets had side laps that were not fitting tightly to the adjacent sheet.  Approximately 10% of the roof had securing screws and nails that were not tightly fixed to the top side of the roof sheets to provide a watertight seal. Case No: 264004 Determination Page 5 of 8  Approximately 50% of the roof flashings that seal the area where the lower section of the split level residence abuts the higher level were not tightly secured to the roof sheets to provide a weatherproof seal.  Approximately 10% of the roof had surface corrosion. Parts of the corroded areas were significant, particularly around the lead flashed toilet vent pipe.  This has resulted in holes in the roof sheet surface which has allowed water to penetrate into the roof void and deposit on the fibrous cement eave lining of the residence.  S considers that this area is not the cause of water ingress into the kitchen and dining room areas.  Corrosion was also evident in the quad gutter around the perimeter of the residence but this is not the source of the water ingress into the kitchen/dining room area either.  The recorded roof pitch is 2.3 degrees. This does not comply with the manufacturer’s minimum pitch requirement of 5 degrees for corrugated roof sheets which has been applicable since 1963. The roof sheets are estimated to have been installed aro und 1965.  S considers the low roof pitch has allowed water to pond on the roof surface. The water has then tracked over the side laps of the sheets and into the roof void, eventually depositing on the ceiling lining of the kitchen/dining room.  This is considered a defective building work and its repair would be a maintenance related issue.  Wind driven rain has also been able to enter under the metal flashings along the eastern wall of the residence where the lower section of the split level residence abuts the higher level and eventually track down the kitchen wall from behind the plaster cornice. This is also a maintenance related issue.  Water has been entering through the roof sheet side laps and under the metal flashings over an extended period of time. The internal damage is not the result of a single storm event. 31. To support his position, the Applicant has provided an expert report from building inspector K. K in summary says the following:  There is evidence to support the conclusion that wate r has entered the roof cavity from the roof gutter and vent pipe flashing.  K is unable to determine the exact source of water causing damage to the ceiling without removing the roof sheeting and insulation.  There is significant damage and distortion of the ceiling lining consistent with water damage, particularly to the centre of the building.  There is damage to the ceiling and wall linings in the toilet room directly under the vent pipe. Case No: 264004 Determination Page 6 of 8  A downpipe diverts water from the roof to the footpath. During the flood event, this downpipe was covered by floodwater at the footpath. This may have blocked the downpipe, causing water to back up and overflow from the gutter into the eaves lining and transfer to the internal ceiling.  The ceiling lining is at a similar level to the eaves lining.  There are several holes in the roof sheet and the sealant has deteriorated between the flashing and the roof sheet. There is no seal to the flashing around the vent pipe. A significant amount of water could enter the roof eaves lining and roof cavity from this area.  The roof sheets appear to be adequately fixed to the battens in order to prevent water penetration from water flowing over the corrugations. However, there are some fixings missing which would allow minimal water entry. 32. Both K and S have provided photographs which show the damage to the ceiling and the state in which the roof sheets are. 33. Based on the evidence and reports available, I accept the roof sheeting was in a poor condition and this has greatly contributed to the claimed damage. 34. The Applicant has mentioned that the only times he observed water entering the property was when the downpipes were blocked and that this was the case during the storm event that caused the loss. 35. The Applicant considers that the effect of water blocking the downpipes and stormwater not being able to drain from the gutters would have caused the water to overflow onto the roof and caused the damage. 36. S has not addressed the Applicant’s concern in their report. K says that it is possible for water to back up during a storm and overflow from the gutter into the eaves lining and transfer to the internal ceiling, if the downpipe is blocked. 37. Although I accept the possibility of this occurring, I am not satisfied that there is sufficient evidence to show that the damage was caused by a single storm event and not by a defect in design or workmanship. 38. Further, I note the Applicant had previous acknowledge of this happening twice in the past. I am of the view that this would have made it evident that the damage was a result of maintenance issue of the roof sheeting and/or the rainwater draining system. 39. As to the roof pitch, the parties argue that the fact its pitch does not adjust to the manufacturer’s standards of 1963 may or may not be relevant depending on the year the house was built. 40. The Applicant has argued that the house could have been built before 1963. The FSP has argued that the house could have been built in 1965 (as per Case No: 264004 Determination Page 7 of 8 S’s estimation) or as per the information relied on by the Applicant an d a title search document, somewhere between 1970 – 1974. 41. The FSP has provided a title search document, which is presumably for the house subject of the dispute. The document shows the Applicant as the owner and a mortgage coinciding with the indicated year of purchase. 42. This document shows the title was created in 1974 and may shed some light about the time the property was built. However, the Applicant has indicated that he owns another property in the area. I am not privy to the details of that property or if there is a mortgage on it. 43. Without further clarification as to the link between the title search document and the property in question, I am unable to accept that this establishes on the balance of probabilities the year when the house was built and I do not base this Determination on a failure to comply with building regulations. 44. I note that it is not an insurer’s responsibility to carry out pre-insurance inspections. Instead, it is an insured ’s responsibility to keep their property in a good condition if they wish to seek insurance cover. 45. I note the Applicant has provided information regarding how the state government has approved his application to the disaster relief appeal. 46. Regrettably, the Applicant has not clarified what was the information he provided that made the state government overturn its initial decision and approve his application. 47. Further, even if this information had been provided, I note that a decision on the approval or denial of a claim is strictly based on the terms and conditions of the relevant insurance policy. The criteria may differ from those employed by the government to approve their applications. In essence there is no connection between a decision by the Appeals management and this dispute with the FSP. 48. As to the application of section 46 of the Act, I am not satisfied it applies to this dispute as the FSP’s exclusion clause does not include a temporal aspect which could potentially make the exclusion inapplicable if the Applicant had not been aware of the roof pitch defect at the moment of getting into the contract of insurance. 49. Based on the available information and considering the Applicant had knowledge of this type of damage (water entering the inside of the property) occurring in two previous occasions, I am satisfied that the cause of damage would be gradual deterioration, wear and tear, defect in design and workmanship and maintenance related issues to the roof sheeting. Case No: 264004 Determination Page 8 of 8 Determination 50. On the basis of the available information, I determine that the FSP is entitled to d eny the Applicant’s claim under the terms and conditions of the policy .

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.