Home / Financial Firm (Unknown - Insurer) / Determination 263821
Determination 263821
Denial of claim for collapsed pivot irrigator; vehicle impact not shown to have occurred in policy period
Summary
The applicant's farm irrigation pivot collapsed and he claimed it was weakened by a vehicle impact. The FSP denied the claim, and AFCA found the applicant had not shown a listed impact occurred during the policy period.
The applicant bore the onus of showing a listed event, such as impact by a vehicle, occurred during the period of insurance, and the evidence showed only a possible impact at an unknown earlier time.
Subjects and remedies
no remedy
Text of the determination
Case No: 263821 Determination Page 1 of 6
Case number: 263821
General Insurance - Small Business/Farm Insurance - Commercial Property -
FSP Decision - Denial of Claim - Impact - Onus
22 May 2012
Background
1. The Applicant holds a farm insurance policy with the Financial Services
Provider (FSP). The policy includes farm machinery cover and the relevant
policy schedule specifically listed a “50 ACRE CENTRE PIVOT IRRIGATION
UNIT” (pivot) with a sum insured of $50,000.
2. On or about 27 May 2011, the Applicant lodged a claim with the FSP for
damage to the pivot.
3. On 23 November 2011, the FSP denied the claim on the following grounds:
“At this stage, there is no evidence which confirms the cause of the collapse
and it is not sure whether the initial damage if any occurred within the policy
period. Both repairers have provided assumptions as to the cause. However,
we have no evidence of what may have impacted the irrigator, if this is a listed
event insured, and if this occurred within your period of insurance.”
4. The Applicant is no t satisfied with the FSP‟s decision, hence this dispute.
Summary of Applicant’s position
5. The Applicant relies on a report by Repairer M which partly states “Our
inspection… revealed that one of the spans…had been hit by either a
vehicle at some time or that something collided with it, possibly a tractor or
harvester in the past, and this had weakened one or more of the truss rods”.
6. The Applicant says that the pivot “had been working perfectly” five days
before it collapsed and that it collapsed on start up.
7. He suggests that it was damaged by one of the contractors‟ machines during
harvesting. The contractors may not have noticed that they had bumped it or
chose not to mention it to the Applicant.
Determination
Case No: 263821 Determination Page 2 of 6
Summary of FSP’s position
8. In its Notice of Response, the FSP says that Repairer M “has chosen to
speculate on the possibility of an impact”.
9. It also says that its loss assessor “considered that there was no evidence of
impact damage” to the pivot and that impact damage “was not su bstantiated
by the photographs of the [pivot]”.
10. In its further submission to the Financial Ombudsman Service (FOS) on 2
February 2012, it says that it has received a new report which advises that
impact is unlikely and bolt failure is probable.
11. The FSP relies on the following policy provisions contained in the Product
Disclosure Statement (PDS):
“ Cover – Listed Events
…
Impact by an aircraft, spacecraft or satellite, or anything dropped from
them.
Impact by vehicles or watercraft, at the situation.
Impact by a falling tree or part of a tree. ”
Issue
12. Whether the FSP must indemnify the Applicant for damage due to an impact
by a vehicle.
Reasons for decision
Repairer M’s Report
13. The Applicant has submitted a report from Repairer M dated 27 May 2011.
The report relevantly reads:
“Report on damaged Irrigator…
Our inspection of the collapsed 3 spans and overhang of the Reinke Centre
Pivot revealed that one of the spans, probably the end, or fourth span had
been hit by either a vehicle at some time or that something had collided with
it, possibly a tractor or harvester in the past and this had weakened one side
changing the centre of gravity and altering the structural integrity. This caused
the span to collapse pulling the other two spans down, and the overhang. The
spans collapsed in line indicating the collapse was not due to a failed
alignment component. Only a trained person would possibly notice the
change in the span. The weight of the water in a span of this length is
approximately 13 tonne. The spans sag with the weight of the water and this
sag is relaxed when the system stops watering as the water runs from the
sprinklers and drains in the spans. This sagging and relaxing of a damaged
truss rod was probably the eventual cause of the collapse. We have seen
Case No: 263821 Determination Page 3 of 6
systems damaged by cane harvesters previously and the driver claimed to not
know he had struck the system.
…
The price to complete these repairs after disassembly of the collapsed span
and overhang is $47860.00 plus GST ($52646.00 incl GST)”.
FSP’s Assessor’s Reports
14. The FSP appointed Company C to assess the damaged pivot.
15. Company C, through Assessor B, issued five reports from June 2011 to
October 2011.
First Report Dated 23 June 2011
16. Notably, the first report dated 23 June 2011 agreed with Repairer M‟s
findings and recommended that the FSP cash settle the Applicant as the
loss is covered under the terms of the policy.
17. This report relevantly reads:
“ Extent of Loss / Damage :
Inspection by ourselves and [Repairer M] indicate that one of the support
stays on one of the sections of the plant had been impacted and when the
insured began its rotation it has collapsed under its own weight. Damage to
the unit is excessive.
Whilst everything is standing and opening fully, these units are very secured,
however the slightest distortion causes them to collapse with all associated
pipes and braces then being extensively damaged.
Replacement cost of the unit of this type is in excess of $60,000.00. The
insured has obtained a quotation from [Repairer M]… to a total value o f
$47,860.00…
On that basis it would be our recommendation that the manner be finalised by
cash settlement…”
Fifth Report Dated 26 October 2011
18. The FSP instructed Company C to make further inquiries.
19. In his fifth report, Assessor B changed his findings and recommendation.
20. The report relevantly reads:
“You will recall from our previous reports that there is an allegation that the
irrigator has sustained impact from a tractor or other farm machinery causing
a weaken truss rod. This weakening has caused the span to possibly hang to
one side changing the centre of gravity and altering the structural integrity. It
is alleged this has caused the span to collapse pulling two other spans down
and the overhang.
At the time of our inspection there was no evidence of impact damage that we
could view to the irrigator. The photographs to hand do not present the
evidence as suggested.
Case No: 263821 Determination Page 4 of 6
The policy coverage for this item is shown under the farm machinery section
which is a listed events policy. There appears to be no evidence confirming
this item has been damage as a result of the impact by a vehicle or watercraft
or any other listed events in the policy.
At this time it is our recommendation that this matter be considered for decline
due to a lack of evidence of a listed event causing any damage.
If the Insured can provide some evidence to the contrary at some future point,
the matter can be reviewed at that time.”
Engineer’s Report
21. The FSP has submitted to the Financial Ombudsman Service a report by S,
a mechanical engineer, from F Engineering.
22. The report is dated 15 December 2011 and states that a site inspection was
conducted on 8 December 2011.
23. The report is 20 pages long. The Summary and Conclusion of the report
relevantly reads:
“ Summary
…
Bolt Failure:
To sheer this bolt took some force. The impression of the threads into
the side of the strut and bracket show strain. A critical strut that holds
the arching pipe in the end of the wheel support is noted. The
segment 5 tail end wheel bracing was stressed in the collapse. We
see no signs of an impact of collision in this area or on the framing,
struts or pipe to explain this possibility, but we can‟t rule it out. No
other machine was in the area at the time of the collapse we are told.
When the drive unit pulls the irrigator around the circle, it moves first
and the other segments follow, using their steering arms to guide how
far to move. There was some misalignment in the 3 and 4 segments
and the strain on the left hand side struts is greatest in this condition.
This is the side where the bolt and strut gave way.
It is possible, this bolt failed, causing the relaxation of the stress but
created a dramatic release of force that ripped back along the irrigator.
The tail section was full of water at this stage, heavy and cantilevered,
it would have swayed or dropped as the wheel support was
compromised at this same point in time.
Bending Failures:
The movement and release of the strain to other segments would
appear to be catastrophic. The forces and weight could not be
retained by the pipe sections – forming the upper truss member in
compression. The failures are mostly compression and crushing
failure. They bent at strut welds and high stress points. Some
corroded points were involved with localised thinning on the metal.
Segment 3 has large distortions and twisting moments and point7 has
crashed to the ground, as did point 15 in segment 2. The total collapse
of the segments then followed.
Case No: 263821 Determination Page 5 of 6
Conclusion
In conclusion, we find overall a series of failure occur as the result of a
structural failure in a member. The exact point of failure is suggested
in the bolt failure on the wheel support on segment 5.
We have no way of determining exactly why, but the resting unit
showed minor alignment movement in segment 3 -4 and this is a
suggested outcome. If another pipe portion had failed prior to this, and
that caused the bolt to fail, we cannot rule that out, but evidence of
that is impossible to determine.
The systematic ripple effect is evident and segment 3 has the largest
movements, pulling segment 4 over, collapsing the segment 5 wheel
and segment 2 gave into the movement and collapsed as well. The
rubber pivot ends saved the pivot segment 1 from failing.”
Analysis and Conclusion
24. The Applicant‟s expert, Repairer M, is of the opinion that “one of the spans,
probably the end, or fourth span had been hit by either a vehicle at some
time or that something had collided with it, possibly a tractor or harvester in
the past and this had weakened one side changing the centre of gravity and
altering the structural integrity”.
25. The FSP‟s loss assessor agreed with Repairer M on 23 June 2011. He wrote
that “Inspection by ourselves… indicate that one of the support stays on one
of the sections of the plant had been impacted”.
26. The Panel is not persuaded by the FSP‟s loss assessor‟s subsequent report
on 26 October 2011 which completely contradicts his earlier assessment.
27. However, the Panel notes and accepts the FSP‟s Engineer‟s statement:
“ The segment 5 tail end wheel bracing was stressed in the collapse. We see
no signs of an impact of collision in this area or on the framing, struts or pipe
to explain this possibility, but we can‟t rule it out.
…
The exact point of failure is suggested in the bolt failure on the wheel support
on segment 5. ”
28. The Applicant argues “There is no reason why the broken bolt was not (h)it
by a vehicle”.
29. Since the FSP‟s Engineer had not ruled out impact, and on the other hand
Repairer M suggested impact by a vehicle (which the FSP‟s assessor
originally agreed with), it is arguable that there is a possibility that the bolt
failed because of an earlier impact by a vehicle.
30. However, the Panel agrees with the FSP that the Applicant must show that
impact occurred during the period of insurance.
31. The FSP says “tha t the claim has been lodged just over a year after
inception of the insurance policy”. It then argues “the speculative theory
Case No: 263821 Determination Page 6 of 6
provided by the (A)pplicant‟s repairer provides for a lengthy period of time
between an initial impact and the ultimate „eventual‟ conclusion of the
subsequent chain of events”.
32. The Panel notes that Repairer M vaguely states “ hit by either a vehicle at
some time or that something had collided with it, possibly a tractor or
harvester in the past ”. The Applicant has not provided evide nce that shows
that the impact occurred during the period of insurance but contends that if
the pivot “was damaged a long time ago it would ha ve collapsed a long time
ago”.
33. The Panel accepts that five days before the collapse, the pivot was being
used and was in good working condition. However, this does not necessarily
mean that impact occurred only within those five days or during the period of
insurance.
34. It is arguable that the impact occurred outside the period of insurance.
Following Repairer M‟s reas oning, the impact could have occurred sometime
in the past, prior to policy inception and this “ weakened one side changing
the centre of gravity and altering the structural integrity ” of the pivot , until it
finally collapsed during the period of insurance.
35. Thus, while the Panel accepts that there is a possibility that some impact,
even by a vehicle, may have occurred at some time, the Panel is not
persuaded by the evidence before it that a relevant impact occurred during
the period of insurance.
Determination
36. On the basis of the available information and the above reasons, the Panel
determines that the FSP is entitled to deny the Applicant‟s claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.