Home / Financial Firm (Unknown - Insurer) / Determination 263135
Determination 263135
Denial of claim - flood exclusion (Fernvale inundation)
Summary
The applicants' home was inundated by creek overflow during the January 2011 storm, and the FSP declined the roughly $67,000 claim under the flood exclusion. AFCA accepted the hydrology evidence that floodwater caused the loss and found the exclusion applied.
Hydrology evidence established on the balance of probabilities that creek floodwater caused the damage, engaging the flood exclusion in both the accidental damage cover and general exclusions; neighbours' outcomes were not binding.
Subjects and remedies
home or building damagenatural disasterno remedy
Text of the determination
Case No: 263135 Determination Page 1 of 6
Case number: 263135
General Insurance - Domestic Insurance - Home Building & Contents –
Accidental Damage - Flood - FSP Decision - Denial of claim-Exclusion/
condition
6 June 2012
Background
1. The Applicants held a Home Building and Contents Insurance Policy (the
policy) with the Financial Services Provider (FSP).
2. The insured property in Fernvale Queensland suffered extensive damage
arising from the significant weather events experienced in Queensland (Qld)
during January 2011.
3. Upon completing its investigation into the circumstances of the loss, the FSP
proceeded to decline the claim, on the basis the damage was due to the
excluded event „Flood‟.
4. The Applicants remain dissatisfied with the FSP‟s decision to decline the
claim and are seeking complete indemnity for their loss estimated to be in
the vicinity of $67,000.
Summary of Applicants ’ position
5. The insured building was constructed 2.4m above the flood level recorded
during the 1974 floods as required by the Local Council approved plans.
6. Stormwater entered the property at approximately 11.00am on 11 January
2011. It began to rise rapidly and inundated the home up to a level of 75mm
and subsequently draining away within four hours.
7. The stormwater responsible for the loss came down a normally dry channel
from the adjacent hills. It was of such intensity that it moved two of the
Applicants‟ shipping containers full of work and farm equipment 0.5 -1km
downstream.
8. There is a major inconsistency between the outcomes of their claim when
compared to those of their neighbours residing within the area.
Determination
Case No: 263135 Determination Page 2 of 6
9. The Applicants have been responsible policyholders insured with the FSP for
many years and believe it would be reasonable for the claim to be accepted
arising from the extraordinary weather event.
Summary of FSP’s position
10. The policy provides cover for „Accidental Damage‟ that includes incidents
arising covered under specific conditions that include those caused by
„Storm, Rainwater‟ and Water Damage‟ escaping from a fixed pipe or drain,
but specifically excludes damage caused by „Flood‟.
11. The FSP maintains that the damage to the Applicants‟ home is solely due to
the actions of flood. The FSP relies upon information obtained from the
Applicants, the location of the property, a site specific hydrology report,
Insurance Council of Australia (ICA) Report, legal precedent and other
information within their files.
12. Whether there is any negligence attached to the decisions made by the local
authorities during a catastrophe is not a factor which alters the Applicants‟
entitlement under the policy.
13. Floodwater rarely acts alone and in most cases will have stormwater
intermingled with floodwater to inundate the premises. Floodwater that mixes
with stormwater and then inundates a property is still excluded from cover.
The legal principle relating to this is known as the „Wayne Tank Principle‟.
14. Further, rising stormwater that cannot drain into a watercourse because its
already in flood is also considered floodwater. It is only when stormwater
alone, independent of any floodwater, inundates premises that the FSP is
able to accept the damage as being storm damage.
15. The onus is on the Applicants to establish that they have suffered a loss
which falls within the scope of cover available to them under the policy.
However, the FSP maintains that the Applicants have not made available
any evidence to substantiate their position that the damage claimed is due to
stormwater alone. Further, the Applicants were not present at the time of
loss.
16. The FSP relies on the following policy provisions:
“Page 12 Accidental Damage Cover
We will cover your buildings or contents for any accidental loss or damage.
There are also a number of incidents we will cover under specific conditions –
these are listed on the following pages.
…
Any cover we provide is subject to exclusions. (For exclusions to this cover,
see page 31)
…
Case No: 263135 Determination Page 3 of 6
Page 31-32 Exclusions to your cover
Any cover we provide is subject to the following exclusions.
Accidental Damage Cover, Additional Cover and Strata Title Mortgagee
Protection exclusions
We will NOT cover any loss or damage as a result of, or caused by
flood
…
Page 35-36 General exclusions
We will NOT cover any loss or damage, or liability as a result of, or arising
from
flood or storm surge
…
Page 58 Glossary of words with a special meaning
flood
the covering of normally dry land by water escaping or released from the
normal confines of a watercourse or lake, whether or not it is altered or
modified. Flood also includes water escaping from the confines of any
reservoir, channel, canal or dam. ”
Issue
17. Whether the FSP was entitled to decline indemnity to the Applicants for their
claimed loss under the policy.
Reasons for decision
18. As advised to the parties, FOS has considered it appropriate to expedite the
dispute in accordance with the Operational Guidelines to the FOS Terms of
Reference. This is because of the complex nature of the issues. This dispute
has not been the subject of a FOS Recommendation and has proceeded
directly to Determination.
19. This decision has been made by a Panel consisting of an Ombudsman, a
representative with extensive experience in the insurance industry and a
representative with extensive experience in consumer claims.
20. There has been an exchange of material between the parties. Each party
therefore is aware of the issues and has had the opportunity to comment. In
these circumstances the details contained in the relevant hydrological
reports will not be recited in this determination except where considered
relevant.
21. Prior to arriving at a determination the Panel has read and considered all the
material submitted by the parties to FOS.
Case No: 263135 Determination Page 4 of 6
22. The Panel notes the parties do not dispute the following:
The Applicants held an active Home Buildings and Contents insurance
policy with the FSP at the time of loss.
The FSP provided and the Applicants received the relevant policy
documentation including the Product Disclosure Statement (PDS) and
Certificate of Insurance (COI).
The insured property sustained significant damage arising from water
inundation and which, on the balance of probabilities, came from the
channel/creek located at the rear of the insured property.
The damage occurred on 11 January 2011, at which time the
Applicants were not present at the property.
Proximate Cause for the loss
23. The Panel has been provided with hydrological evidence submitted by the W
organisation commissioned by the FSP. Further, the FSP relies upon the
information made available by the ICA through its appointed hydrology
panel. As there has been an exchange of material between the parties both
having had the opportunity to comment, information from the various reports
relied on will only be restated, where considered relevant.
Hydrologist W’s “Hydrology Report relating to the January 2011 Storm (Site
specific report) dated 1 April 2011
A watercourse Pryde Creek (PC) flows north to south through the rear of
the property. According to 1:25,000 scale of topographic mapping for the
area, Split Yard Creek (SC) and Catarrh Creek (CC) discharge in to PC
about 1km upstream of the property.
The total catchment area upstream from the property is estimated to be
20km 2 , including the catchment area feeding to a dam in the upper
reaches of SC.
This dam is used to obtain hydro-electricity during discharge to the
adjacent and much larger Wivenhoe Dam.
A majority of the catchment area draining to PC upstream of the property
bypasses the dam on the SC.
The elevation of the property is about 60m to 70m AHD.
Rainfall records obtained from Wivenhoe Dam gauge (reflective of rainfall
in the relevant area) indicates up to 340mm of rainfall within about nine
hours starting from 5.00am on 11 January and this represents a storm in
excess of a 100yr ARI.
Based on available topographic information, it is estimated that the local
stormwater catchment draining to the property does not extend past the
nearby Wivenhoe-Somerset Road.
At the front of the dwelling the height of the floor level above the ground
level is about 0.5-1m. Despite receiving local rainfall in excess of 100yr
Case No: 263135 Determination Page 5 of 6
ARI, it is unlikely that any stormwater run-off entered the house prior to
the inundation by floodwater from PC.
The floor level of the dwelling (rear) is at an elevation about 3m above the
immediate overbank area of PC. It is likely that the intense rainfall across
the upstream catchment would have created sufficient flow along PC to
cause the reported depth of flow to a peak level above the house floor
level.
The damage included the dislodgement and displacement of a steel and
wood bridge that spanned the creek between the balcony and a section of
outdoor decking constructed across the creek.
The reported and observed scale of damage at the property could not
have been caused by stormwater run-off from the immediate local
catchment draining to the property.
W is of the opinion the inundation of the property and associated damage
to items and structures was caused by overflow from the normal confines
of a watercourse i.e. PC.
24. The Panel notes that the information available in the relevant ICA Hydrology
report supports the findings and position taken by W in its report submitted to
the FSP in respect to the significant weather conditions experienced in the
Fernvale area in January 2011.
25. The Panel is persuaded the Applicants‟ loss was, on the balance of
probabilities, the result of floodwater from the creeks and more specifically
Pryde Creek which are in close proximity to the insured property.
26. In the absence of any evidence to the contrary, the Panel is not satisfied that
the Applicants have been successful in establishing that the water damage
to their property is the result of stormwater inundation.
27. As the FSP‟s policy wording also outlines that flood is an exclusion to that
defined event, the FSP is entitled to rely on the exclusion. It follows that the
Applicants‟ claim does not succee d on this occasion.
28. The Panel acknowledges the Applicants reference to the outcomes of their
neighbours‟ claims, in an attempt to establish the damage arose from
stormwater run-off. In addition to the Panel not being provided with any
probative evidence in this regard, it is satisfied that the workings and
decisions reached by other insurers are not binding and /or necessarily
relevant to the workings of the FSP and/or the provisions of the contract
relied upon.
29. Further, decisions made on individual claims in respect to other properties
insured with the same insurer, may also vary arising from the terms of the
contract, geographical position and/or construction of these properties.
30. The Panel‟s commentary in this regard is supported by the supplementary
report from W of 5 October 2011.
Case No: 263135 Determination Page 6 of 6
31. Within the supplementary report, W specifically addresses the differences
between the Applicants‟ property and a property at which the Applicants say
a claim was made.
32. W describes significant differences in the topography, the height of each
property to ground level and their respective positions in regard to Pryde
Creek and the relevant flow path.
33. Having considered these differences, W explains why a different outcome
may have resulted in that different location.
34. The Panel is sa tisfied that W‟s supplementary report confirms that each
dispute must be looked at on the basis of its own individual circumstances
and the outcome may be different even for locations in close proximity to
each other.
Accidental Damage Cover
30. The Panel note s that the Applicants‟ policy of insurance also covers
accidental loss or damage (including a number of listed events) to the
insured property, therefore considering the circumstances of the loss, prima
facie, they have a claim that falls within the cover provided by the policy.
31. Accordingly, the onus shifts to the FSP to establish that, on the balance of
probabilities, the damage was caused by circumstances which are excluded
from cover under the policy.
32. In light of the matters discussed previously, the Panel is satisfied that the
proximate cause for the Applicants‟ loss was floodwater inundation. The
Panel notes that the policy excludes cover for loss arising from flood within
the “Accidental Damage Cover” as well as the “General Exclusion”
provisions which apply to all sections of the policy.
33. Accordingly, as indemnity available under the accidental damage cover is
also subject to the above noted flood exclusions; the FSP is entitled to deny
indemnity for their loss.
Determination
34. On the basis of the available information the Panel determines that the FSP
was entitled to decline indemnity to the Applicants for the loss claimed.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.