Home / Financial Firm (Unknown - Insurer) / Determination 262292

Determination 262292

Denial of claim - flood exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2012-06-29
ProductGeneral Insurance · Strata
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$7,834
SourceAFCA PDF

Summary

The Body Corporate claimed $7,833.67 for water damage to common areas of a strata complex during January 2011 floods, and the FSP declined the claim under the flood exclusion. AFCA found the inundation was floodwater from the Brisbane River backing up through stormwater drains and that the FSP was entitled to deny the claim.

Water backing up from a river in flood is floodwater, and the fact that sandbags were breached does not change its character under the policy.

Issues

Subjects and remedies

natural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 262292 Determination Page 1 of 5 Case number: 262292 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim-Exclusion/ condition 27 June 2012 Background The Applicant is the Body Corporate for a multilevel apartment complex (the property) insured with the Financial Service Provider (FSP) under a Residential Strata Insurance Plan (the Policy). The Applicant lodged a claim for water damage to the car park, foyer and other common areas of the property that occurred between 12 and 13 January 2011, following the significant weather events experienced in Queensland (Qld) during January 2011. The FSP on concluding its investigation into the circumstances of the loss declined the claim o n the basis the damage was due to the event „Flood‟, which is specifically excluded under the policy. The Applicant seeks indemnity under the Policy and claim $7,833.67 for the damage. Summary of Applicant’s position There was substantial damage at the property through no fault of the Body Corporate or Owners. Following warning of potential flooding in the area, the caretaker arranged for the building to be sand bagged, lifts taken to the top floor and locked, power to be shut down and all vehicles and other items removed from the garage. At 0400 hours on 13 January 2011, two tenants securing the property noted 6cm of water had entered the foyer, with nearly 2 feet of water outside the building and in the garage. The water receded on 14 January 2011, after which it was discovered that the car park, foyer and other common areas had suffered damage. The Applicant submits that the water that damaged the property “ did not come directly from the drains, but was secondary water that breached the sandbagged walls ” securing the doorways to the property, and should be covered by the Policy. Determination Case No: 262292 Determination Page 2 of 5 Summary of FSP’s position The FSP states that it is entitled to deny the Applicant ‟ s claim on the basis that the proximate cause of the water inundation was flood. The FSP does not deny that water may have breached the sandbags but maintains that the purpose of the sandbags was merely to mitigate the damage caused by the inundation, the cause of which would still be considered flood. The FSP relies on the Assessor‟s report, the hydrology report commissioned by the Insurance Council of Australia (ICA Report) and a site specific hydrology report (Site Report) dated 17 January 2012. The FSP relies on the following policy provisions: “ What you are covered for Policy 1 – Insured Property The Policy is designed to cover you for accidental loss or damage to your insured property (building and common area contents) that occurs during the period of insurance ” ... “ Exclusions – What we do not insure 1. We will not pay for loss or damage: a. Caused by Flood.” “ General definitions – the meaning of some words ... Flood Means when water that is normally contained in a Water Catchment System increases because of rainfall or snow melt (whether in the immediate region or elsewhere) or is deliberately released by an authority, and the water overflows onto land that is not normally covered by water.” Issues 2. Whether the FSP is entitled to deny the Applicant ‟ s claim. Reasons for decision 3. As advised to the parties, FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. This is because of the complex nature of the issues. This dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination by an Ombudsman. Case No: 262292 Determination Page 3 of 5 4. There has been an exchange of material between the parties. Each party therefore is aware of the issues and has had the opportunity comment. In these circumstances the details contained in the relevant hydrological reports will not be recited in this determination except where considered relevant. Cover under the Policy 5. It is an accepted principle of general insurance law that an insured bears the onus to establish, on the balance of probabilities, that they have suffered a loss caused by an event or incident to which the policy responds. Once so established, the onus shifts to the insurer to prove that a policy exclusion applies. 6. The Applicant does not dispute that they were provided with a Policy Disclosure Statement (PDS) which informed them of the applicable policy terms. 7. I have reviewed the PDS and note that the policy provides cover for accidental damage. According to its ordinary meaning, „accidental‟ means „happening by chance or accident, or unexpectedly” (Macquarie Dictionary). I also note that the policy excludes damage caused by flood, which is clearly defined in the policy. 8. It is not in dispute that the Applicant ‟ s property was inundated with water as a result of a significant weather event that affected much of Queensland in early 2011. 9. Nor is it in dispute that damage caused by flood water is not covered by the Policy. What is in dispute is whether the water that inundated the property was flood water. Proximate cause of the inundation 14. The FSP relies on its Assessor‟s report, the ICA Report and the Site Report to establish that the property was inundated by flood water. 15. I have considered the following relevant facts :  The property is located 0.36km from the Brisbane River.  The property was inundated at about 0100am on 13 January 2011, although the exact time is unknown.  The property was inundated to a depth of 0.35m abo ve ground level in the car park.  The foyer, which has a floor level of 0.15m above the surrounding ground level, was inundated to a depth of 6cm.  By mid morning on 12 January 2012, the building manager observed water surcharging out of stormwater inlet pits on either side of Sydney Street. Case No: 262292 Determination Page 4 of 5  About 2000 hours on 12 January 2011, water was seen at the end of the property. Sydney Street was completely inundated at this time.  By 0400 hours on 13 January 2011, 6cm of inundation was observed in the foyer. The water level outside the property was higher. The sandbags at the entrances to the building had prevented more water from entering the foyer. 10. The Site report provides the following relevant information:  Based on the recorded hourly rainfall at Bowen Hills Alert, 3.0km northwest of the property, no significant rainfall was recorded after about 1700 on 11 January 2011.  Peak stormwater runoff from the surrounding catchment area would have occurred within 30 minutes after the peak rainfall.  The recorded local rainfall in the vicinity of the property was not particularly severe for short durations. For durations up to 12 hours, the recorded rainfalls had the average recurrence intervals (ARI) of less than 1 year. The ARI for 24 – 72 hour storms was between 1 and 2 years. Higher peak rainfall intensities are regularly experienced in Brisbane.  According to the Brisbane City Council Floodwise report, the ground levels at the property range from 2.4 m AHD to 2.7m AHD with a 100 year ARI flood level of 2.5m AHD.  Based on debris marks and topographic data, the peak water level in the vicinity of the property was approximately 2.9m AHD.  Based on the observed depth of inundation, the car park at the property would have been inundated above floor level at approximately 0100 hours on 13 January 2011 by floodwater from the Brisbane River. The report concludes:  The initial and peak inundation of the property was caused by floodwater from the Brisbane River flowing back up along the underground stormwater drainage networks in the vicinity of the property. 11. I have also considered the following conclusions contained in the ICA Report:  “ Rain ceased in the Brisbane City area around 1800 hours on Tuesday 11 January, some 24-30 hours before flood levels in the Brisbane River peaked... As the floodwave passed downstream along the Brisbane river, backwater flooding occurred up the tributary creeks... Flooding along the mainstream on the Brisbane River and along the lower tributaries was principally caused by releases from Wivenhoe Dam (dam releas e flooding).”  “...Any area that was inundated after 1800 hours on Tuesday (11 January) will have been water flow inundation .” Case No: 262292 Determination Page 5 of 5 12. I have considered all the evidence and am satisfied that: a. There was insufficient rainfall in the vicinity of the property on 12 January 2011 and 13 January 2011 to cause storm water runoff inundation. b. Inundation was first observed at the property more than 36 hours after the peak rainfall in the area had occurred. c. The building manager‟s observation that water was surcharging out of stormwater inlet pits on either side of Sydney Street on 12 January 2011 supports the hydrology evidence that there was backwater flooding from the Brisbane River, flowing back up along the underground drainage networks. d. The peak river levels noted on the hydrograph contained in the Site report corresponds with the peak water level marks observed in the vicinity of the property. e. The thick mud in the garage and driveway after the water receded is indicative of flood water inundating the property. f. The conclusions reached in the Site Report are consistent with the findings contained in the ICA Report. 13. Based on the evidence, I am satisfied on the balance of probabilities that the proximate cause of the inundation was floodwater from the Brisbane River flowing back up along the underground stormwater drainage networks in the vicinity of the property. 14. The fact that the water breached the sandbag barriers to enter the property does not change the fact that the water was flood water, according to the terms of the Policy. 15. I am therefore satisfied that the resultant damage is excluded from cover. Determination 16. On the basis of the available information I determine that the FSP is entitled to deny the Applicant ‟ s claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.