Claim denial for collapsed farm power pole (corrosion exclusion)

FirmFinancial Firm (Unknown - Insurer)
Decided2012-05-31
ProductGeneral Insurance · Business / commercial
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$32,152
SourceAFCA PDF

Summary

A farmer claimed $32,152.26 for repairs after a storm collapsed a steel power pole. The FSP denied it for corrosion, and AFCA accepted the expert evidence that corrosion was the proximate cause.

The proximate cause of the collapse was corrosion, which is specifically excluded, and the storm winds alone would not have caused the failure.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 259905 Determination Page 1 of 4 Case number: 259905 General Insurance - Small Business/Farm Insurance - Commercial Property - FSP Decision - Denial of claim-Exclusion/ condition 30 May 2012 Background 1. The Applicant holds a farm insurance policy underwritten by the Financial Services Provider (FSP). The relevant period of insurance operated for twelve months beginning from 5 January 2011. 2. On 4 February 2011, one of the steel poles on the Applicant ’s property collapsed resulting in power failure. There was a storm in the area at the time. Based on this, the Applicant lodged a claim for the cost of repairs to the power pole totalling $32,152.26. 3. The FSP denied the claim on the basis the power pole collapsed due to corrosion. The Applicant has disputed this. Summary of Applicant ’s position 4. In summary, the Applicant disputes the FSP’s decision on the following bases:  There was superficial rusting of the steel supports for the power pole. Otherwise, the poles were structurally strong and sound.  There were extremely strong winds experienced at the time of the loss.  He maintained the power poles to an appropriate standard at all times. Further, the poles were subject to a safety inspection by the power company every 12 months.  The FSP’s expert is unclear as to whether the standards applicable at the time of the pole’s construction would have withstood winds of up to 61km/hr, which was the speed of the winds at the relevant time of loss.  He is without electricity. He does not require power poles but rather requires electricity, which is covered under the policy. 5. Accordingly, the Applicant maintains he is entitled to be indemnified for the cost of repairs to the power pole. Determination Case No: 259905 Determination Page 2 of 4 Summary of FSP’s position 6. The FSP relies on its expert’ s report and the following policy provisions to deny the claim: “ Section A - Home Cover … Defined Events Cover We will pay for loss or damage at the Address caused by the following Defined Events: … 8. Storm or rainwater … … What you are not insured for … 2. loss or damage to your property caused by: a. … f. wear, tear, rust, corrosion, …” Issues 7. Whether the FSP is entitled to deny the Applicant ’s claim. Reasons for decision 8. Due to the amount in dispute, the matter has been referred to an Ombudsman for Determination in line with the Operational Guidelines to the Service’s Terms of Reference . This dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination 9. I am satisfied that a full exchange of information has take n place between each party and that each party has had the opportunity to address any issues raised. 10. The FSP is seeking to rely on an exclusion clause and therefore has the burden of establishing that it applies on the balance of probabilities. 11. The substantive issue in dispute i s the cause of the power pole’s collapse. In determining the issue of causation, the courts have stated the proximate cause of the damage must be established. This is generally done by determining the dominant or effective ca uses of the loss. 12. The FSP is relying on an expert report dated 24 March 2010 that contained the following relevant remarks in this regard: Case No: 259905 Determination Page 3 of 4  The poles inspected were consistent with the structural details provided on a drawing prepared by the State Electricity Commission (SEC) of Victoria dated 1983.  The drawing shows the top of the footings were to be finished 100mm above ground level with 25mm fall away from the structure. The power pole on the Applicant’s property had the top of the footing buried approximately 100mm below ground level.  The remaining base section of the steel structure was still fixed to the top of the footing. This remaining steelwork was significantly corroded. It was also apparent that fall had not been provided to the top of the footing as required by the SEC drawings.  The actual power pole structure also showed signs of corrosion at its base where the failure occurred. It appeared two of the three vertical pipe sections had failed with minimal deformation at the base, whilst the base of the third pipe section exhibited significant deformation.  The Applicant had advised that when the powerline support structure failed, two of the vertical pipes had broken and he cut the third pipe (which had deformed significantly as a result o f the pole failing).  The design wind load is not nominated on the design drawings but design codes and practices at the time would likely require a design to withstand wind load much higher than 61km/hr.  It is likely that either the powerline support struc tures and footings were not originally constructed as per the SEC drawing or fill had been placed on top of the footings after construction as part of the operations of the grape block.  As a result of the base structure being below ground, corrosion of the steelwork at and below ground has occurred. This has resulted in a reduction in the structural capacity of the rusted sections.  Similarly to the failed power pole, the top of footings and bottom of steelwork for the remaining power poles were found to be located below ground level. Significant corrosion of the steelwork is evident at the base of the pole. 13. Based on this, the expert concluded as follows: “Based on our inspection and desktop assessment, it appears the failure of the powerline support structure has likely been caused by significant corrosion of the structural elements at the base of the power pole, reducing the structural capacity of the pole such that the wind loads imposed by the storm event on the 4 th of February 2011 caused the structure to fail and collapse. This corrosion is largely contributable to moisture becoming trapped due to poor drainage at the top of the footing/base of steelwork. It is evident that the remaining powerline support structures have also undergone significant corrosion at the base and as such it is recommended that these power poles be removed immediately to prevent structural failure.” Case No: 259905 Determination Page 4 of 4 14. The FSP noted the expert is employed by a specialist engineering and technical consulting company. In these circumstances, I accept t he FSP’s expert was appropriately qualified to examine and report on the likely cause of the power pole collapse. In addition, I consider his comments are consistent with the photographs supplied which showed evidence of corrosion. 15. The Applicant has stated he maintained the poles and that the power company inspected them annually. However, the Applicant has not specifically described the type of maintenance he undertook or how regular he did so. In addition, there is nothing to indicate the nature of the inspections undertaken by the power company, namely whether it was extensive or thorough enough to identify the corrosion that was evident in the expert’s inspection. 16. Although I agree that there were strong winds at the time of the loss, it appears evident that these winds alone would not have caused the power pole’s collapse given this type of incident was isolated to the poles on the Applicant ’s property. 17. I note the FSP’s expert’s opinion regarding the cause of damage is uncontested by any other expert. The expert is of the opinion the failure of the power pole is due to the corrosion. 18. Given this, I accept that on the balance of probabilities, the proximate cause of the power pole’s collapse was due to corrosion. 19. The Applicant has also submitted that his claim is for loss of electricity. However, I note this loss of electricity was a direct result of the power pole’s collapse. Further, it is the cost of repairs to this power pole that will result in the restoration of his electricity. 20. As such, I accept the issues are the same, in that the Applicant must satisfy the damage to the power pole, which resulted in the loss of electricity, was proximately caused by an insured event. For the reasons outlined, I have accepted the FSP’s contention that the proximate ca use of the Applicant’s loss is corrosion, which is specifically excluded under the policy. Determination 21. On the basis of the available information I determine the FSP is entitled to deny the claim as the Applicant’s loss was caused by an event excluded under his policy.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.