Home / Financial Firm (Unknown - Insurer) / Determination 257495
Determination 257495
Claim denial - balcony water damage attributed to defects, workmanship and wear and tear
Summary
The insured claimed storm damage to a balcony and the FSP denied the claim for defects, poor workmanship and wear and tear. The panel, reviewing a Recommendation, found the FSP entitled to deny because no storm event was established.
The insured had to prove an insured storm event caused the damage, and the rainfall records and the FSP's expert evidence showed the damage arose from workmanship and defects rather than a storm.
Subjects and remedies
home or building damageno remedy
Text of the determination
Case No: 257495 Determination Page 1 of 5
Case number: 257495
General Insurance - Domestic Insurance - Home Building - Denial of Claim -
Wear & Tear - Building Defect - Storm
27 September 2012
Background
1. This is a review of a Recommendation by the Service’s Case Manager dated
18 July 2012, in favour of the Financial Services Provider (FSP). The
Applicant has rejected the Recommendation and in accordance with the
Terms of Reference this matter has been referred to me for Determination.
2. The relevant background, summaries of the parties position and issue in
dispute have been briefly set out in paragraphs 1 to 8 of the
Recommendation and in the interest of clarity and completeness I will repeat
same.
3. The Applicant held a home building and contents insurance policy with the
FSP which was current at the time of the loss.
4. The Applicant lodged a claim for water damage to a balcony at his home
following a storm on 14 July 2011.
5. The FSP denied the claim on the grounds that the damage was caused by a
combination of building defects, poor workmanship and wear and tear.
Summary of Applicant’s p osition
6. The Applicant says the damage was caused by a storm.
7. As such, he says he should be afforded cover under the terms of the policy.
Summary of FSP’ s position
8. The FSP says the damage was caused by a number of factors including
wear and tear, building defects and poor workmanship.
Determination
Case No: 257495 Determination Page 2 of 5
9. The FSP relies on the following policy provisions contained within the
Product Disclosure Statement:
“ We do not insure you for any loss or damage that is caused by or arises
from:
Defects in design, structure, materials or workmanship
...
wear and tear, gradual deterioration, or fading ”
Issue
10. Whether the FSP is entitled to deny the Applicant’s claim.
Reasons for Decision
11. There has been an exchange of information and each party has had the
opportunity to address the issues that have been raised. I have read all of
the exchanged material and I have considered the parties submissions
including the FSP’s further submission dated 30 August 2012 and the
Applicant’s further submissions dated 16 August 2012 and 30 August 2012.
In passing I note that the Applicant has not provided any fresh information in
respect of the matter in dispute.
12. In making her Re commendation the Service’s Case Manager set out her
reasons in paragraphs 11 to 17 and again, in the interest of clarity and
completeness I will restate those reasons.
11. Only once an insured event has been established does the onus transfer
to the FSP to show on the balance of probabilities that the loss claimed falls
within one or more exclusions of the policy.
12. Following lodgement of the claim, the FSP appointed an assessor to
attend the Applicant’s property and report on the extent and cause of the
damage. The assessor in turn appointed a building consultant to attend the
property to accurately determine the cause of the water damage. The building
consultant concluded:
“This balcony has recently been covered by a[n] installation of concrete.
It is my professional opinion that the installation of this concrete is NOT
appropriate as it is NOT addressing the underlying issue that is either
damage to the waterproofing membrane installed under the ceramic tiles or
most likely the complete absence of any appropriate membrane. There is
also the issue of an inappropriate substrate.
Rainwater ingress that is occurring into the retreat is emanating from the site
of a non-compliant Vee gutter that is installed behind a front parapet wall.
I found that rainwater ingress has three separate causal effects, firstly there
is overflow from the inadequate noncompliant Vee gutter installation,
secondly there is penetrations occurring around an electrical fitting that
penetrates the Vee gutter that has never been supplied the appropriate
Case No: 257495 Determination Page 3 of 5
plumbing flashing – and thirdly there is damage to the vital sarking due to
electrical works that is allowing leakage into the ceiling cavity.
All three of these installations are in very close proximity to one another and
in all likelihood all three are allowing rainwater ingress to occur, however it
would manifest as a single leakage site within the retreat. All retreat leakage
is due to faulty workmanship and non-compliant plumbing works.
Rainwater ingress that has caused damage to the ceiling of the master
bedroom is the result of the “blown in” ceiling insulation lodging between the
lapping rows of sarking. This insulation is absorbing rainwater that
penetrates under the tiles onto the sarking creating a leakage issue.
Leakage due to installation shortfall.
...
My inspection of the entire roof to this house failed to find any evidence of
any storm damage or storm created openings. To the contrary all rainwater
ingress can be attributed to faulty workmanship issues dating from the time
original house installation. The only exception to this is the application of
concrete over the original front balcony substrate which is in my professional
opinion a totally inappropriate repair attempt.”
13. The Applicant has provided an inspection report from a home buyer’s
service. This report detailed:
“This owner...has consulted our company to conduct an independent
building inspection report on the property to assess and comment on the
condition of the balcony above the front entrance to the dwelling.
...
THE FRONT BALCONY AREA:
...
Evidence of a water proof membrane was visible where the balcony paving
runs into the concealed metal guttering along the north side of the balcony.
...
The extent of damage that has occurred to the front balcony structure in my
opinion has been caused by excessive rainfall in a short space of time in
which the existing concealed metal guttering could not cope with.”
14. I note that the Applicant’s expert does not comment on the issues raised
by the FSP’s expert in relation to the defective sarking, inappropriate
application of concrete to the balcony area, non-compliant guttering or blown
in insulation concerns but addresses only the issue of the waterproofing
membrane to an area of the balcony. As such, I have no reason to doubt the
additional concerns raised by the FSP’s expert in relation to poor
workmanship, building defect and wear and tear.
15. I have had the opportunity of reviewing the rainfall data from the Bureau of
Meteorology (BOM) for the date of loss. On 14 July 2011, the BOM records
show that a total of 0.6mm of rain fell and the wind speed for the day are
described as “Calm”. This, in my opinion, does not constitute storm
conditions.
16. I am therefore of the opinion that the water damage has been occurring
over a period of time rather as a direct result of one storm.
Case No: 257495 Determination Page 4 of 5
17. As previously detailed, the onus lies first and foremost with the Applicant
to demonstrate that the insured event of storm has caused damage to his
property. As I am satisfied that there was no storm event on the date of loss,
the Applicant’s claim must fail.”
13. In summary, the Case Manager considered the expert reports provided by
the Applicant and by the FSP and concluded that the FSP’s report (“C”) was
more persuasive than the report provided by the Applicant’s expert (“PO”).
14. The Applicant’s expert PO expressed the opinion that damage was caused
to the front balcony structure as a result of excessive rainfall in a short space
of time in which existing concealed metal guttering could not cope with the
down poor. He also expressed the opinion that a water proof membrane had
been compromised or was inadequate causing leakage of water onto the
balcony and the underside of the exposed section of the structural flooring
beneath the balcony.
15. By contras t the Applicant’s expert C delivered a comprehensive report noting
that the water leakage was attributed either to damage to the water proof
membrane or perhaps, the absence of an appropriate membrane installation.
Further, the expert C expressed the opinion that the rainwater ingress had
three separate causal effects, firstly, overflow from the inadequate gutter
installation two secondly because of inappropriate plumbing flashing and
thirdly, because damage to the vital sarking in respect of the electrical works
allowed leakage into the ceiling cavity.
16. The Applicant has pinned his case to the fourth aspect of C’s report in
respect of the existence of the waterproof membrane. The Applicant ’s expert
stated that he was satisfied that there was a membrane where as the FSP’s
expert C believed there may not have been a membrane but that if there was
a membrane it had been compromised and allowed leakage.
17. As noted above the FSP’s expert C did not confine his opinion to the
existence or breakdown of the water membrane but rather to the
combination of the three factors referred to above.
18. Having carefully considered the matter I am of the opinion that the resolution
of the conflict between the experts is to be decided in favour of the FSP’s
expert C. His report in my view is more cogent in dealing with the matters at
issue.
19. Furthermore, I agree with the Case Manager in stating that the Applicant
must demonstrate that an insured event caused damage. There is no
evidence of any heavy down poor at or about the time of the reporting of the
damage and quite apart from the expert evidence the Applicant has failed to
establish that any damage was caused by an insured event. As noted above
if there was a down poor of water the damage was caused by the
combination of factors relied upon by the expert C and the FSP is entitled to
deny the claim.
Case No: 257495 Determination Page 5 of 5
Determination
20. The FSP was entitled to deny the Applicant’s claim.