Home / Financial Firm (Unknown - Insurer) / Determination 255292
Determination 255292
Denial of building foundation movement claim as soil movement, shrinkage and tree exclusions
Summary
The applicant's claim for storm-related foundation and building damage was declined as subsidence, shrinkage and wear. AFCA found the exclusions were not made out and, applying fairness, ordered the FSP to pay 50 per cent of storm-related repair costs and the geotechnical report costs.
The FSP did not establish that subsidence alone was the proximate cause, so under Terms of Reference 8.2 a fair apportionment of 50 per cent was applied.
Subjects and remedies
home or building damagenatural disasterpay claimreassess claim
Text of the determination
Case No: 255292 Determination Page 1 of 9
Case number: 255292
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of claim-Exclusion/ condition – Terms of Reference 8.2
22 May 2012
Background
1. The Applicant holds a Home Insurance policy with the Financial Services
Provider (FSP). The policy covers the insured building up to $232,250
subject to an excess of $100.
2. On 28 February 2011 the Applicant lodged a claim for damage to the
building. The FSP sent various experts to assess the property.
3. The FSP declined the claim on the basis the damage arose over several
years and was the result of normal expansion/shrinkage of the soil.
4. The Applicant disputes the FSP‟s declinature on the basis the damage arose
from a significant storm event in Victoria which caused the foundation soil to
become soft due to an increase in the water content.
Summary of Applicant’s position
5. The Applicant relies on her geotechnical report dated 3 July 2011. I note the
following from this report:
The site is CLASS S-M.
Groundwater was not encountered at the test pit/bore hole1 during
investigation.
There are fresh cracks on the rear wall, laundry side wall, kitchen
ceiling and also old cracks on the concrete paved ground between the
outside laundry windows and carport had opened up recently.
The owner reported that those fresh cracks occurred during or after the
heavy rainfall.
The expert believes heavy rainfall was a major contribution to those
cracking and footing sinking.
Soil profile shows down to 2000mm is deep silt overlaying silty clay.
The dwelling footing is sitting on silt.
Determination
Case No: 255292 Determination Page 2 of 9
Under normal weather conditions the silt has enough bearing capacity
to support the footing but after heavy rainfall the water infiltrates the
ground and interacts with silt beneath the footing to decrease bearing
capability.
The expert proposed underpinning founded 2300mm deep below the
existing ground level onto stiff silty clay.
6. The locale of the insured property was subject to a 1 in 100 year storm on 4
February 2011. Approximately 2 weeks after these heavy rains, the home
began to sink and massive cracking occurred.
7. The cracking to the home had not occurred over 2 years as suggested by
the FSP‟s building consultant. The Applicant submits the expert reports from
the building assessor and her geotechnical engineer confirm the cracking
was recent. The Applicant has never stated that it has occurred over two
years. The home has previously had no cracking and withstood rains after
the 9 year drought broke.
8. The Applicant contends that her geotechnical engineer‟s opinion should be
preferred given he took soil samples and is mo re qualified than the FSP‟s
building consultant.
9. The Applicant notes a goodwill offer from the FSP was to pay 50% of the
building assessor‟s total costing for repairs in the sum of $4,676.65. This
offer did not include external repairs and the Applicant did not view this
quote prior to contacting the Service.
10. The Applicant seeks a determination the FSP accept the claim and pay all
repair costs.
Summary of FSP’s position
11. The FSP relies on the following policy terms and conditions:
“Storm
You are covered for loss or damage as a result of storm.
You are not covered for storm damage to:
- The building or contents where the water, wind or hail has entered the
building through an opening not created by the storm.
....
THE POLICY DOESN‟T COVER EVERYTHING
General exclusions – apply to the overall policy
“Unless included in additional cover, we will not cover loss, damage or legal
liability caused by:
- Wear and tear and lack of maintenance, including rust, corrosion,
deterioration....
...
- Actions of trees, plants or their roots;
Case No: 255292 Determination Page 3 of 9
...
- Erosion or earth movement including shrinkage;
- Subsidence and landslide, unless it happens immediately following an
earthquake or explosion;”
Terms of Reference
8.2 Dispute resolution criteria
Subject to paragraph 8.1, when deciding a Dispute and whether a remedy
should be provided in accordance with paragraph 9, FOS will do what in its
opinion is fair in all the circumstances, having regard to each of the following:
a) legal principles;
b) applicable industry codes or guidance as to practice;
c) good industry practice; and
d) previous relevant decisions of FOS or a Predecessor Scheme (although
FOS will not be bound by these).
12. The FSP relies on a report from a building assessor dated 24 March 2011
from which I note the following:
The Applicant explained that the cracks started to appear in the walls
over the last couple of weeks.
There were multiple cracks in the walls and ceiling throughout the
house.
The damage is due to the house moving from excess water on the
ground around the house.
13. The FSP relies on a report from a building consultant dated 26 May 2011
from which I note the following:
The Applicant informed the building consultant damage had been
ongoing for two years and that her father had been maintaining the
cracks.
The subfloor area was constructed on concrete strip footings and
concrete piers supporting the bearer and joist floor frame. The subfloor
area was quite moist at the time of the inspection.
The subfloor ground level was lower than the soil and turf around the
perimeter of the eastern and northern elevations of the residence.
There was no evidence of any surface water drainage to remove water
away from the subfloor footing area.
The reactive clay foundation on which the residence was constructed
moves as a result in moisture content fluctuations. This has caused
cracking throughout the home.
The region was exposed to prolonged drought with recent increased
rains causing general resultant swelling of the soil/foundations.
The building consultant concluded the cracking and movement to the
building is a result of ground movement under and around the concrete
footings over time.
Case No: 255292 Determination Page 4 of 9
The air vents to the subfloor are inadequate to ventilate and dry out the
subfloor area.
14. The FSP relies on a geotechnical report dated 21 October 2011, from which
I note the following:
The FSP‟s geotechnical expert has read each report and n otes his
opinion is not based on any site investigation on the subject property.
The FSP‟s geotechnical expert generally agrees with the building
consultant‟s report that the building distress is likely to have been
caused by soil movements caused by moisture variations. However,
there are no conclusions regarding the extent to which the drought and
rainfall events are likely to have contributed to the movement and
distress of the building.
The geotechnical expert is particularly critical of the Applicant‟s
geotechnical expert for the following reasons:
- The dual soil classification of S-M is not possible given S means
slightly reactive and M is moderately reactive. There is no
allowance under the Australia Standards for such a dual
classification.
- The area has two distinct soil profiles which is derived from
alluvial (river) deposits and would best be classified as M. The
other profile is generally Class H. If the Applicant‟s Geotechnical
report is correct it suggests the site is located within alluvial
deposits. Further, the geological map shows that the site is
located on the border between the two geologies mentioned. It is
therefore possible that sections of the site may be susceptible to
Class H soil reactivity.
- A building suffering distress from moisture level variations in the
soil is not consistent with a Class S.
- The Applicant‟s report indicates the soil as moist at the surface
and then dry-moist at depth. This is not consistent with the
movement distress being caused by saturation of the foundation
soils as a result of rain.
- The description of silt as medium dense is incorrect, silt is a
cohesive soil and such a classification only relates to sand soil.
- The conclusion that movement in the building is likely the result of
softening of the founding soils due to rain is unlikely to be correct.
It is a common misconception that the natural soil beneath a
footing will wet up to the extent that it will deform beneath the load
from the domestic dwelling. The loads from such buildings are low
and are unlikely to cause even a silty soil to fail in its bearing
capacity.
- The recommendations for underpinning are disagreed with as it
will cause disturbance to the existing footings and encourage
differential movement.
Case No: 255292 Determination Page 5 of 9
It is likely the damage to the building has been caused by deep seated
drying related shrinkage type settlements of the underlying clay soils.
The soil drying is likely to have been caused by the drying action of
trees and shrubs surrounding the subject building as indicated on the
current satellite imagery. It is also likely that the re lative seasonal
dryness over recent years may have contributed to the movement and
distress.
It is recommended that the findings of the report are confirmed by a site
specific geotechnical investigation.
15. The FSP submits that its geotechnical engineer has pointed out many
inconsistencies with the Applicant‟s geotechnical engineer‟s report. It does
appear the insured building is located on a Class H soil type which is a
highly reactive soil type. The FSP‟s expert also noted that the actions of
nearby trees and shrubs are likely to have caused shrinkage of the
underlying clay soils.
16. The building consultant‟s report indicates that the cracks have been ongoing
for 2 years which would indicate an issue which required ongoing
investigation.
17. The Applicant has failed to demonstrate an insured event occurred that is
covered by the policy or that the damage was caused by a single event.
18. The policy excludes wear, tear, lack of maintenance, gradual loss of any
kind, erosion and earth movement including shrinkage subsidence and
landslide and the action of trees.
19. The FSP contends the expert reports demonstrate the exclusion applies and
it was entitled to decline the claim.
Issues
20. Whether the FSP was entitled to decline the claim.
Reasons for Decision
21. There has been an exchange of material between each party, and I am
satisfied each party has had an opportunity to reply to the issues raised.
22. I have read each party‟s submissions and materials and will only refer to the
relevant submissions and materials raised.
23. The parties do not dispute the following:
The Applicant had a valid policy covering the relevant period of
damage.
Case No: 255292 Determination Page 6 of 9
There was a severe storm event on 4 February 2011.
The policy covers the insured event of storm.
The Applicant lodged a claim for damage 2 -3 weeks after the storm as
she had noted moisture in the home and cracking.
The Applicant‟s claim relates to both external and internal damage.
24. First, I note that there are inconsistencies in the expert reports provided to
the Service regarding precisely what the Applica nt informed them. The
majority of the reports have indicated a 2 week timeframe between the rain
and the appearance of cracking throughout the home. It is further noted that
there is at least one expert that specifically indicates the cracks appear to be
r ecent. The only report which deviates from this is the building consultant‟s
report which states it was a 2 year period and the Applicant‟s father was
patching the cracks during this time. This is information the Applicant
disputes she provided to the building consultant. I believe that there has
been some miscommunication between the Applicant and the building
consultant which has led to the consultant recording it as 2 years rather than
2 weeks. This is particularly so given the consistent period of 2 weeks
recorded everywhere else.
25. I accept the cracking was only 2 weeks old and accordingly I do not consider
the damage arose from wear, tear and failure to maintain the property.
26. I will now review whether the damage arises from subsidence or the actions
of tree roots, as both causes of damage are excluded under the policy.
27. I note that both the building assessor and the Applicant‟s geotechnical
engineer provided an opinion the damage was due to movement resulting
from excess water around the home. The geotechnical engineer has stated
the soil type had decreased bearing capacity as a result of rainfall and
indicated the rainfall was a major contributing factor to the cracking and
footing sinking.
28. The building consultant indic ated the subfloor area was “quite moist” and the
subfloor was lower than the ground level around the perimeter of the eastern
and northern elevations of the residence. The consultant indicated the
residence was constructed on reactive clay and the foundations have moved
as a result of moisture content variations.
29. The FSP‟s geotechnical engineer indicated the soil was likely to be highly
reactive class of soil. Further, the geotechnical engineer provided a finding
that the likely cause of movement is caused by deep seated drying related to
shrinkage settlement of the underlying clay soil. The drying is likely to be
caused by the drying actions of trees.
30. The expert opinions provided are somewhat varied. It appears that a ll of the
experts have agreed that the founding soil is reactive and will move in
response to moisture content. The Applicant‟s geotechnical engineer has
indicated that the storm/rain event would have been a large contributing
factor to the movement. The building consultant only indicates moisture
content would have affected movement. The FSP‟s geotechnical engineer is
Case No: 255292 Determination Page 7 of 9
the only party which indicates the movement is the result of drying actions of
tree roots and shrinkage (indicative of a dry soil).
31. I prefer the experts who have actually inspected the property and note the
FSP‟s geotechnical expert strongly recommended it perform a site inspection
to confirm its findings.
32. Whilst I note the strong criticisms of the Applicant‟s geotechnical expert, the
FSP‟s geotechnical expert does in fact confir m the highly reactive soil on
which the property is founded. I have considered the FSP‟s geotechnical
engineer‟s opinion that a single story building carries a low load and is
unlikely to cause even a silty soil to fail in its bearing capacity. However, the
lack of a physical inspection means that the FSP‟s expert has not confirmed
the load bearing arrangement of the property. Further, I have concerns that
the FSP‟s expert has not discussed the effect of the rain and/or the increase
in the moisture content to this reactive soil on the foundations in its findings.
It is also unclear whether the satellite pictures of the trees are in fact current
at the time of the report. Expert evidence as to earth movement and the
influence of tree and vegetation requires a physical inspection and the
conduct of soil tests.
33. Based on the evidence before me, I accept that the property sits on a
reactive soil type which is silty and that the foundation soil will react to
moisture content variations resulting in building movement. Further, that the
soil received an increase in moisture during the severe storm event which
likely resulted in foundation movement.
34. The final question before me is whether the movement of the foundations is
excluded by the policy.
35. For reasons stated above, the evidence before me is insufficient to
demonstrate the exclusion for the drying actions of trees.
36. The exclusion wording states that the policy excludes damage “caused by”
subsidence and landslide. There is no definition within the policy of
subsidence and according the plain English meaning shall be applied. The
Macquarie Dictionary defines subsidence as follows:
“Subside
verb ( i ) ( subsided , subsiding ) 1. to sink to a low or lower level.
2. to become quiet, less violent, or less active; abate: the laughter subsided.
3. to sink or fall to the bottom; settle, as lees; precipitate. [Latin subsīdere settle
down]
– subsidence / / ( say suhb'suydns), / /
( say 'subsuhduhns), noun”
37. Accordingly, subsidence of the soil would be a settlement or sinking of the
soil. There is a suggestion from the evidence that the soil has been subject
to some movement but it is unclear whether this was upheave or settlement.
Case No: 255292 Determination Page 8 of 9
38. The secondary issue is whether the loss or damage has resulted from
subsidence alone as the proximate cause. The expert evidence indicates it is
the increase of moisture from the rain event which has affected the soil, not
the soil merely settling in isolation.
39. I have considered whether the principle from Wayne Tank and Pump Co Ltd
v Employers Liability Assurance Corporation Ltd [1974] QB 57 should apply
in this circumstance. The „Wayne Tank‟ principle states that:
“If a loss has two or more proximate or effective causes and at least one
cause is excluded from cover the insurer is not liable.”
40. I note the construction of the exclusion wording requires the loss to be
caused directly by subsidence. This is indicative that there must be a direct
causational link between the loss and the excluded event.
41. Based on the evidence, it does not appear that the damage occurred from
subsidence alone. Rather the subsidence was a consequence of the rainfall
event. Accordingly, I do not consider that there are two concurrent causes of
loss or that the loss arose solely from subsidence. Given this, I do not think
the Wayne Tank rule applies as the subsidence occurred as a consequence
of the insured event of storm and not concurrently with the storm event.
42. Given this, the FSP has not established that the loss was caused directly by
subsidence alone and consequently the exclusion has not been made out.
43. I do consider that some subsidence has likely occurred once the soil
commenced drying out. In my opinion it is appropriate to involve Terms of
Reference 8.2 and derive a remedy that is fair in all the circumstances.
Accordingly, it is fair in all the circumstances to apportion the loss 50% to the
Applicant.
44. I note the Applicant has raised concerns over the scope of works but not
provided her own quotation.
45. I also note the Applicant has expended monies to obtain an expert report
detailing the cause of the damage to the home. Further, I have relied on this
report to some degree to make a finding in this matter.
Determination
46. On the basis of the available information I determine the following should
occur within 14 days of the Applicant accepting this Determination:
(a) The Applicant may obtain quotations for the repair works and
provide same to the FSP.
(b) The Applicant will provide the FSP with an opportunity to arrange a
physical assessment of the property in order to determine a scope
of repair works.
Case No: 255292 Determination Page 9 of 9
(c) Once the FSP is in receipt of the Applicant‟s repair quotation(s) and
any assessment report, the FSP will calculate the cost of repairs
arising from the storm event.
(d) The FSP make payment of 50% of the whole of the repair costs
arising from the storm event within 14 days of receiving any repair
quotation(s) and assessment report.
47. The FSP will make payment of the Applicant‟s geotechnical report costs
once the Applicant provides proof of payment for same.
.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.