Claim denial - seepage, inherent defects and faulty workmanship exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2012-01-16
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

An owner-builder claimed water damage to a newly built basement, attributing it to an open sliding door during a storm. AFCA preferred the insurer's engineer over the applicant's non-independent engineer, found the damage was caused by seepage and building defects, and held the section 46 defect exception unavailable, so no indemnity was owed.

Once the insured establishes a prima facie loss, the insurer must prove an exclusion applies, and the seepage, inherent defect and faulty workmanship exclusions were established on the balance of probabilities.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 247473 Determination Page 1 of 6 Case number: 247473 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim 16 January 2012 Background 1. The Applicant held a home building and contents insurance policy with the Financial Services Provider (FSP) from 15 April 2010 and the policy was current at the time of the loss. 2. The Applicant lodged a claim with the FSP for water damage sustained to the flooring of the basement. 3. On 7 December 2010 he informed the broker the damage was caused as a result of a burst pipe in the bathroom. 4. However, on 30 December 2010, he informed the broker the damage was caused as a result of a storm and subsequent water entry into the property. 5. The FSP denied the Applicant’s claim on the grounds that the policy excludes cover for a claim arising from seepage, faulty workmanship, inherent defects, etc. 6. The Applicant is of the view the damage to the property was caused by storm water entering the property via an open door and expects the claim to be accepted by the FSP. Summary of Applicant’s position 7. The Applicant believes the loss occurred as a result of his son-in-law accidentally leaving the sliding door to the subject room open during a storm event. 8. The Applicant rejects the FSP’s findings and presents a repor t from his engineer (B) and expects the FSP to honour the claim. Determination Case No: 247473 Determination Page 2 of 6 Summary of FSP’s position 9. Subsequent to the lodgement of the claim, the FSP appointed a loss assessor, leak detection service (A) and an engineer (M) to investigate the circumstances surrounding the loss and to identify the cause of the loss. 10. The FSP relies on M’s findings which suggest the water entry to the dwelling was the result of significant defects to the property. 11. The FSP sa ys the Applicant’s opinion that the front entry door was left open during the storm event remains unsubstantiated. 12. The FSP relies on the following policy provisions: “This Policy does not cover: ... (b) loss or damage resulting from or caused by: ...  water seeping through the wall or floor, other than escaping from a gutter, drain, tank, pipe, water-bed or other apparatus designed to store or carry any liquid located on or outside the home site; ...  inherent defects, structural defects, faulty workmanship or faulty design; ...  any consequential loss other than that specifically provided by this Policy;” 13. The FSP maintains denial of the claim on the grounds the damage was caused by the above factors which are excluded under the policy. Issue 14. Whether the FSP is entitled to deny the Applicant’s claim. Reasons for decision 15. Due to the nature of this dispute, FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. This dispute has not bee n the subject of a FOS Recommendation and has proceeded directly to Determination. 16. I am satisfied that a full exchange of information has taken place between each party and that each party has had the opportunity to address any issues raised. Case No: 247473 Determination Page 3 of 6 17. The onus of proof rests on the Applicant to establish that, on the balance of probabilities, he has suffered a loss caused by an insured risk. Once the Applicant has established that the loss was caused by a risk insured under his policy, the onus then shifts to the FSP to show that, on the balance of probabilities, the loss falls within an exclusion clause in the policy. 18. The importance of the wording above must be emphasised. It is for the Applicant to establish his case on the balance of probabilities. The subsequent evidence to which I refer must be considered in that light. 19. The Applicant was the owner/builder of the insured property and the property sustained water damage in December 2010. 20. The Applicant initially notified the cause of damage as a burst pipe and t hen three weeks later amended the cause of loss to storm/rain water entry into the property via an open sliding door. I do not think anything turns on this changed position. The Applicant has provided an adequate explanation for it. 21. The issue remains whether the storm/rain water entered the property via the sliding door to the basement or as a result of other causes as highlighted by M, in what can be described as a very thorough report. 22. A attended the Applicant’s property and identified the following: “The subfloor inspection to PVC stormwater lines which are all fed under house and with water released through lines no leaks to pipes were found. Subfloor dirt was found to be wet and all down pipe fed holes to under house in brickwork are open. Also holes in brickwork found throughout and to windows sills, also noted was open drain holes from balcony into cellar which is next to lower level room. Water egress to lower level room is from vent holes, holes in brickwork where downpipes feed through, holes in brickwork window sill and no drainage pipe from balcony. House is near completion and spray tests to these areas showed water egress to under subfloor.”(sic) 23. M attended the Applicant’s property in May 2011, approximately five months after the loss and highlights the following as the cause of water of entry into the property:  Seepage through the northern wall of the subject basement rooms;  Incorrect grading of the concrete paving along the north side of the subject room;  Ponding due to incorrect grading of the paving against the subject wall;  Inadequate application of a waterproof membrane on the buried face of the wall;  Absence of caulking at the paving to the north wall interface allowing surface rainwater run-off from the incorrectly graded paving to flo w down the buried face of the wall and contribute to saturation of the soil external to the subject room; Case No: 247473 Determination Page 4 of 6  Suspected inadequate/incorrectly laid AG drain beneath the path which appears to have been laid in fill and therefore could be ineffective;  Insufficient set down of the subject door threshold;  Suspect open brick perp wall vents which were retrospectively sealed by the Applicant including a movement joint presumably to prevent water damage to the subject timbering flooring;  Soil build-up against the rear/western wall causing excessive dampness into the room in the absence of waterproof membrane and suspected inadequate AG drain (if it exists);  Incorrect grading of the paving along the south side of the house and absence of caulking at the paving to brick wall interface;  A suspect AG drain beneath the southern path;  Inadequate caulking and sealing of movement joints and penetrations through external walls;  Bridged attempted brick wall movement joints;  Excessively high paving shedding rainwater run-off directly into brickwork open perps; and  Inadequate drainage provision at the front of the property to address seepage from the front yard. 24. Further M rejects the Applicant’s view that the damage was caused by an open door as below: “Any traces of moisture from this December 2010 event - particularly noting the summer months, would have disappeared within merely a few days or possibly up to a week. The [M] report, however, confirms not only excessively high moisture readings of the timber floor more than four months later but moisture readings in the north wall plaster well above the floor off the scale noting that the wall could not have been affected by rainwater through the door opening. Similar off the scale readings were also noted and taken of the basement floor slab in areas well away from the subject doorway and again some four months after the alleged event. Having regard to the above, it is the Writer’s firm opinion that damage of the magnitude of alleged damage being claimed from alleged rainwater entry through the sliding door (without any date or details of wind direction/rainfall etc.) is completely untenable and unable to be substantiated” 25. The Applicant’s appointed engineer B reported: “As outlin ed above the amount of water that could potentially be entering the rumpus room floors or walls is minute and every point outlined within the report has been developed with speculation and no substantial evidence. The owner has clearly mitigated any risk of water damage and ingress of moisture within this room with a number of measures as outlined above, this building has clearly been built within all design requirements and relevant standards, there has been no evidence that the builder has not met any of these standards. Case No: 247473 Determination Page 5 of 6 In conclusion the list of issues outlined in the [M] report could potentially have minor effect on a house over a long period of time but this building is only 6 months old and the amount of water/moisture that could have potentially entered this room over this short period of time would not have been substantially enough to cause the magnitude of damage that has happened to this flooring (sic).” 26. B confirms that during the construction there were a number of inspections by a licensed building inspector, the Applicant has over 30 years of experience in the construction industry and that he too witnessed the works by regular inspections. 27. The two reports from B are expressed in argumentative terms and in the form of a response to the original (and subsequently the second) report of M. They do not appear to be independent. Had an entirely independent engineer provided a report on behalf of the Applicant, this may well have assisted his position. 28. Due to B’s close involvement in the constructio n process, I am unable to accept his findings as independent and unbiased. Furthermore, I find that he has rejected the findings of M but has not identified the cause of loss and how the subject room sustained such extensive damage. 29. Faced with the divergence between the reports of M and B, I do not consider that the Applicant has overcome the onus referred to in paragraph 17 above. 30. I am not satisfied the sliding door being left open is capable of causing such damage. I am of the opinion that high moisture readings approximately five months after the loss indicate ongoing water seepage issues at the property. 31. The Applicant might have had recourse under Section 46 of the Insurance Contracts Act 1984 (the Act), if it can be established that he was unawa re of the building defects prior to the inception of the insurance contract. 32. Section 46 of the Act provides that if a claim is made in respect of a loss that occurred in whole or in part as a result of a defect or imperfection in a thing and the insured was not aware of the defect or a reasonable person in the circumstances could not be expected to have been aware of the defect or imperfection the insurer may not rely on an exclusion clause that refers to the condition of the thing before the contract was e ntered into. 33. However, based on the fact that the Applicant was the owner/builder of the recently built property (which appears to be near completion), I am satisfied the Applicant must have been reasonably aware of the condition of the property and therefore, he will not be entitled for recourse under Section 46 of the Act. 34. Based on the above, I am satisfied the damage to the Applicant’s property was caused by seepage, inherent building defects and faulty workmanship and therefore, the FSP is entitled to rely on its exclusions. Case No: 247473 Determination Page 6 of 6 Determination 35. On the basis of the available information, I determine the FSP is not required to indemnify the Applicant.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.