Home / Financial Firm (Unknown - Insurer) / Determination 246453

Determination 246453

Retaining wall collapse claim denied under landslide and subsidence exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2011-11-21
ProductGeneral Insurance · Business / commercial
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$20,000
SourceAFCA PDF

Summary

A retaining wall at a commercial property collapsed after heavy rain and the FSP denied the repair claim. AFCA found the expert evidence showed the collapse was caused by landslip or subsidence, which the policy excludes.

The policy covers storm and rainwater damage but excludes damage caused by landslide, mudslide or subsidence, and the expert evidence established that exclusion applied.

Issues

Subjects and remedies

natural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 246453 Determination Page 1 of 4 Case number: 246453 General Insurance - Business Insurance – Commercial Property – FSP ’s Decision - Denial of claim 21 November 2011 Background 1. The Applicant incepted a commercial insurance policy with the Financial Services Provider (FSP) on 1 December 2007. The policy was issued in the name of his family trust and it covered buildings, glass, rental income and liability for a leased property that he owned. 2. On 6 January 2011, a claim was lodged under the policy following the collapse of a retaining wall at the property site. It was reported the wall collapsed following a storm event. 3. Following investigations into the circumstances of the loss which included reports from consulting engineers, the FSP denied the claim as the policy excluded damage caused by erosion, mudslide, rock slide or subsidence under the insured event of storm. 4. The Applicant has referred this matter to the Service seeking indemnity under the policy for the repair of the retaining wall. Summary of Applicant ’s Position 5. The policy covers storm damage to buildings and structures at the site. 6. The retaining wall is a structure that has been in place for 26 years. The retaining wall holds an embankment to stop subsidence which has worked very well. 7. Following unseasonal rainfall in December 2010/January 2011, water coming off the embankment has channelled down one section of the wall undermining it and causing it to collapse. The mounded dirt wall then fell on top of the collapsed wall. 8. Workers returning to the site after the holiday break discovered the collapsed wall under the debris. As such the wall would have had to have collapsed first to allow the mound of dirt behind to subside on top of it. Determination Case No: 246453 Determination Page 2 of 4 9. Quotes to repair the wall range between $19,000 to $35,000. A $20,000 settlement would be acceptable. Summary of FSP’s Position 10. The Applicant provided a brief report from a consulting engineer (MJR) who advised that approximately 35 metres of retaining wall failed due to very heavy storms. MJR noted over 200mm of rainfall caused unstable soil conditions and the amount of runoff coming from the site confirmed the backfill was saturated. 11. The Applicant obtained another engineer’s report (BR) in which it was stated the failure of the wall was likely due to a combination of:  Overland flow off the railway reserve resulting in backfill to wall;  Compaction of backfill behind wall;  Construction of the existing wall. 12. Its own appointed engineer (EM) noted excessive rainfall had caused the existing soil above the wall to lose cohesio n. This then subsided over the retaining wall in conjunction with the stormwater flowing from upstream lots. 13. In this instance, the soil being saturated would have swelled to the point of producing forward movement. Thus the embankment subsided over the wa ll, causing it to fail. Alternatively the soil behind the wall was so saturated that it swelled and produced the forward movement that caused the wall to collapse in turn allowing the embankment to subside. 14. Regardless, both scenarios involve the movement of soil i.e. landslide and/or movement, both of which are excluded by the policy. 15. The FSP relies on the following policy provisions: “ 1 COVER We will pay for loss or damage to the insured property occurring at the location during the period of insurance which is caused by an Insured Event, however any indemnity will be subject to the limit of indemnity or sum insured , the excess and the terms of the policy . … 4 INSURED EVENTS Loss or damage to the insured property described in the certificate caused by: … 7 storm, hail, wind and water including rainwater or snow. PROVIDED THAT that this does not included damage : … b) caused by erosion, landslide, mudslide, rock slide or subsidence; ” Case No: 246453 Determination Page 3 of 4 Issue 16. Whether the Applicant’s claim for the repair of the retaining wall is covered under the terms and conditions of the policy. Reasons for Decision 17. FOS has considered it is appropriate to expedite the dispute in accordance with clause 8.6 of the FOS Terms of Reference. This is because of the issue in dispute and substantive quantum involved. This dispute has not been subject of a FOS Recommendation and has proceeded directly to Determination. 18. This decision has been made by a Panel consisting of an Ombudsman, an industry representative and a consumer representative. 19. There has been an exchange of material between the parties. It therefore is not intended to recite details of the various reports in this Determination except where considered relevant. 20. The Applicant is claiming for the reinstatement of a retaining wall that collapsed as a result of a storm event. No one was present to see the wall collapse. However he says the wall collapsed first which allowed the embankment to subside onto the collapsed retaining wall. The Applicant has based this on staff who worked at the premises finding debris under the dirt. 21. The FSP has relied upon the evidence of its loss adjuster and the attending consulting engineers who inspected the site and reported on the cause of the damage. The reports considered included those from the Applicant’s engineers. The Panel has considered the information from the various reports. 22. The Applicant’s policy covers loss or damage caused by storm and rainwater “ provided that this does not include damage caused by …landslide, mudslide… or subsidence .” 23. The loss ad juster reported “ A 35 – 40.0m length of the retaining wall has been pushed over as a result of a landslide ” and “The landslide itself was caused by a long spell of wet weather that saturated and loosed the soil to a stage where it collapsed and pushed the retaining wall over.” 24. MJR reported “ Approximately 35 metres of retaining wall has failed due to very heavy storms… Failure appeared by variation in soil moisture content”. 25. EM concluded “ The extreme rainfall has saturated the existing red clay soil to a point where there was no cohesion of the soil. This is conjunction (sic) with stormwater flowing over the wall has forced the embankment to subside over the retaining wall.” 26. BR reported: “The site backs onto a Qld Railway reserve and water from the reserve ha s resulted in a slip in the earthworks behind the existing wall. This slip in turn has resulted in the failure of the crib block wall.” Case No: 246453 Determination Page 4 of 4 27. The Applicant has argued that the retaining wall collapsed first based on debris being found under the dirt. However, regardless of this, the expert reports are sufficient to support the argument that landslip and/or subsidence was the cause of the collapse of the retaining wall. 28. Based on the available evidence the Panel is satisfied the damage was caused by an event that was excluded by the policy. Determination 29. On the basis of the available information, the Panel determines the FSP was entitled to deny the Applicant’s claim for the repair of the retaining wall.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.