Home / Financial Firm (Unknown - Insurer) / Determination 242780

Determination 242780

Insurer partly declined flood-related water damage claim under flood exclusion, attributing damage above 300mm to creek flood

FirmFinancial Firm (Unknown - Insurer)
Decided2012-01-09
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed$275,000
SourceAFCA PDF

Summary

The complainant's flood-damage claim was partly declined by the insurer, which relied on a flood exclusion for water above 300mm. AFCA found the insurer liable for stormwater damage except the second level of the main residence, and directed reassessment and settlement with interest.

Under an accidental damage policy the insurer bears the onus of proving an exclusion, and the hydrology evidence did not establish that flood water caused the inundation above 300mm.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay interestreassess claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 242780 Determination Page 1 of 12 Case number: 242780 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim 23 December 2011 Background 1. The Applicant holds a Home Insurance Policy with the Financial Services Provider (FSP). The policy includes building and contents cover for loss arising from accidental damage. 2. On 10 January 2011 the Applicant‟s premises were inundated with water during severe weather events experienced in the region causing extensive damage to the insured premise. The Applicant contacted the FSP and lodged a claim seeking indemnity under the policy for her loss. 3. The Financial Services Provider (FSP) partially accepted the claim on the grounds that the home had been inundated up to 300mm by stormwater run-off prior to flood water inundation. However, it denied the balance of the claim on the ground that the loss was as a result of the flood from a nearby creek and as such was excluded from cover under the policy. 4. The Applicant disputes the partial declinature on the basis that the water all came from the street, rose rapidly in minutes and flowed from the opposite direction of the creek. Summary of Applicant’s Position 5. The Applicant submits that the whole damage was caused by major stormwater run-off and was nothing to do with the creek overflowing behind her property. 6. The Applicant states that around 12.30am on Monday 10 January a surge of water came through the town of Esk rushing through the higher part of the town down to the Applicant‟s property which is at th e base of the mountain. The water volume was significant to knock down fencing and trees on the property and flooded the flat under the Applicant‟s home and filling up to the ceiling which came through the Applicant‟s floorboards and soaked her carpets. 7. The Applicant describes the event as occurring in a 3 minute period. The SES and Police were outside the home telling her to evacuate. The Applicant evacuated her elderly parents out and waded through the water which was then “crotch deep” (later described a s 900mm). The vehicles could not leave as the Determination Case No: 242780 Determination Page 2 of 12 road was then cut off and the Applicant looked back towards the house and could see water rising very quickly. The Applicant was greatly surprised by the quick rise in the water. 8. The Applicant went back to the property just over one hour later and the water had dropped fast, leaving behind debris. 9. The Applicant has taken video footage of the water which ran down the roadside out the front of the property and not from behind the property in the direction of the creek. The Applicant notes the creek/river is up but the Applicant states that at the time of evacuation the creek had not reached the top of the embankment. 10. The Applicant further contends that another FSP‟s hydrologist opined this incident was „flash flood‟. 11. The Applicant has provided several quotations for the repairs to the three homes and the lost/damaged contents. The Panel notes the most recent quotation dated 31 January 2011 to fix the footings and stairs is in the sum of $47,650 inclusive of GST. Further, the observations of the builder were as follows:  The builder has inspected the property prior to the flooding (for alteration works) and since the flooding.  The builder states the stumps supporting the house have subsided up to 200mm from original height.  The house is under extreme structural strain and it has become a safety issue for people at the residence.  The property is progressively deteriorating and the builder opines this is the result of the January floods. 12. The Applicant has calculated her loss as $75,000 to contents and $200,000 to the 3 homes on the property. Summary of FSP’s Position 13. The FSP relies on the following policy terms and conditions: “Accidental Da mage Cover If you have chosen Accidental Damage Home Insurance, we will cover your buildings or contents for any accidental loss or damage. There are also a number of incidents we will cover under specific conditions. These are listed on pages 17 to 20. If you make a claim, you must pay any excesses that apply – you will only need to pay this amount once. Any cover we provide is subject to exclusions. ... Case No: 242780 Determination Page 3 of 12 We will cover your buildings or contents for loss or damage as a result of storm, rainwater or wind. We will not cover loss or damage caused by a named cyclone within 48 hours of the start date of your policy, unless • you took out your insurance with us immediately after another insurance policy covering the same buildings or contents expired, without a break in cover • you took out your insurance with us immediately after the risk passed to you as purchaser of your buildings • you took out your insurance with us immediately after you signed a lease contract for your buildings. We will not cover • swimmin g pool covers, including – solar covers and plastic liners • water entering your buildings – through an opening made for any building, renovation or repair work – because of a structural defect, faulty design or faulty workmanship when your buildings were constructed • free -standing fences made of corrugated fibrous material that do not have a supporting frame, unless – they have been installed and constructed according to the manufacturer‟s specifications • free -standing gates, fences or walls that are made of timber and are more than 15 years old. ... We will cover your buildings or contents for loss or damage caused by water or liquid. We will also cover the cost of finding where the water or liquid escaped from, including the cost of repairing any damage that occurs while looking for the cause. We will not cover your buildings or contents for loss or damage caused by • flood • landslide or subsidence, unless – we agree to cover the incident as described under „Landslide or subsidence‟ • water entering your buildings – through an opening made for any building, renovation or repair work – because of a structural defect, faulty design or faulty workmanship when your buildings were constructed. We will not cover the cost of repairing the item that caused the escape of water or liquid. ... Exclusions to your cover Any cover we provide is subject to the following exclusions. We will NOT cover any loss or damage as a result of, or caused by ... – Flood ... General Exclusions We will NOT cover any loss or damage, or liability as a result of, or arising from – Flood or storm surge. Case No: 242780 Determination Page 4 of 12 ... Glossary of words with a special meaning Accidental loss or damage Damage to, loss or destruction of the buildings that make up your home, or your contents and valuable items, when it is caused by an unintentional act, or an unforeseen and uncontrollable incident. ... flood the covering of normally dry land by water escaping or released from the normal confines of a watercourse or lake, whether or not it is altered or modified. Flood also includes water escaping from the confines of any reservoir channel, canal or dam.” 14. The FSP relies on a hydrologist report which states as follows:  The Applicant‟s property is located in the upper Brisbane sub - catchment which extends from the headwaters along the Great Dividing Range in the West, Brisbane and Jimna Ranges in the North and the D‟Aguilar Range through a wide valley surrounding the Brisbane River to Wivenhoe Dam. The catchment is dominated by woodlands, open forest and relative high energy gradient streams.  The property is close to Sandy Creek which is a tributary of Esk Creek. These streams have small upstream catchments less than 100km2 and form part of the Wivenhoe Dam Catchment.  The Applicant‟s property is owner occupied within a rural re sidential area consisting of [a (sic)] two single story homes constructed on posts. One house has had a separate residence constructed underneath it at ground level.  The hydrologist has obtained the following information from the Applicant: – Intense rainfall began on the morning of 10 January 2011. During the rainfall the run-off was flowing from the local area into the low gully on the property. – The Applicant recalled the water had reached ankle deep on her property when she was approached by SES and local police to evacuate the premises. However in the 3 minutes or so of the evacuation the water rose from ankle to waist deep. – 2 hours later the Applicant returned to find the water had receded but that it had inundated the lower ground floor unit completely, over the floor in one of the houses by approximately 400mm and over the floor in the other house where the ground floor unit is located by several centimetres. The water had left debris of vegetative damage that suggested flow had been towards the gully and creek. The Applicant stated the cause of the inundation was run-off from the south-east due to prolonged intense rainfall on 10 January 2011. Case No: 242780 Determination Page 5 of 12 – The Applicant supplied the video footage of the inundation.  The Applicant‟s property is located on a natural gully that is not recognised as a watercourse on any available geographic maps but would have been part of a relic channel formed by Sandy Creek. The property‟s land slopes down in elevation towards the north-east. The base of the gully passing directly through the backyard of the property and descends in elevation towards the north-west where it intersects with Sandy Creek approximately 150 meters from the property.  The gully on the property functions as a local drainage network that directs run-off into Sandy Creek. Sandy Creek itself has an incised channel with banks that are at least 1 meter above the base of the gully on the property.  The water level marks were observed within both stilted houses. The house had marks indicating over-floor inundation depths of approximately 400mm whilst the higher house had marks that were roughly 100mm over the floor. These marks corresponded with each other roughly, indicating a relatively stationary, leve l peak water surface. The water level marks observed in the raised houses would have been sufficient to fully submerge the ground level unit and as a result it has been demolished.  Sandy Creek showed signs of high velocity flows that exceeded the capacity of the channel at all locations to the north, east and west of the property. Debris observed in other locations around the town of Esk confirms that Sandy Creek overflowed, inundating overbank areas.  The daily rainfall gauge data obtained from the nearby gauge at Esk recorded an accumulation of approximately 130mm, 150mm and 40mm on 9-11 January 2011. The hydrologist notes the peak rainfall intensity would have been sufficient to overwhelm the local drainage system.  The local catchment of the gully on the A pplicant‟s property would have been no greater than 1km2 to the south-west.  From the topographical and rainfall data available it is likely that run-off and overland flow derived from high intensity rainfall on the 10 January 2011, inundated the property to a depth sufficient to inundate the ground floor unit.  The depth required to sustain damage to the two elevated houses at the property would ultimately be caused by overflow from Sandy Creek which eventually inundated a significant portion of the town of Esk.  Judging by the upstream catchment of Sandy Creek, water levels would be expected to respond quickly to intense rainfall (peaking within hours). This is consistent with the Applicant‟s recollection that the rise and fall of water in the property occurred within hours. The catchment that would have contributed to run-off and overland flow directed towards the low gully on the property would also have responded rapidly after the onset of intense local rainfall. Case No: 242780 Determination Page 6 of 12  It was unclear as to whether or not the run-off and overland flow mixed with the subsequent rising water from Sandy Creek. However, it is noted that the lowest portion of the bank in the vicinity of the property is 1 meter above the lowest point in the gully and therefore it is possible that the intense local rainfall led to the inundation of the ground floor unit and receded prior to the overflow of Sandy Creek. The overflow of Sandy Creek would have caused further damage to the ground floor unit and was subsequently the sole cause of damage to the elevated houses on the property.  The hydrologist has provided measurements of the waterline inside one of the properties which is just over 400mm. The hydrologist however opines that the rainfall and topographic data indicate the ground floor unit was inundated up to no more than 300mm from stormwater run-off.  The hydrologist concluded that run-off and overland flow are likely to have inundated the ground floor unit of the property to a sufficient depth to cause damage. However, the peak level of inundation which caused the over-floor flooding of the two elevated houses and submersion of the ground floor unit, are the direct result of the Sandy Creek over-flow. 15. The FSP relies on assessor report dated 5 February 2011 from which the Panel notes the following:  The assessor was informed the water came from the street in front of the house.  The property is at the base of a very high escarpment or bluff and the water from the town swept down to the area where the property is and then flowed to the north along the creek bed that is behind the property.  The property was subject to heavy rainfall on Monday 10 January 2011 and the rainfall did not stop until 11 January 2011.  The property was inundated on the evening of Monday 10 January 2011. However, the Applicant believed the water level in the property peaked in the afternoon on this same day.  At its peak the water inundated the main house 0.2m, the flat below up to the ceiling and the granny flat 0.5m.  The water came from the West.  The assessor concluded the water was deep enough and flowing fast enough to do significant damage to the home. The quotations for repairs received totalled $141,318.20. The assessor set a reserve on the contents of $75,000.  The assessor opined that the damage arose as a result of inundation of water from rain storm water run-off and recommended the policy respond. Case No: 242780 Determination Page 7 of 12 16. The FSP contends that whilst the Applicant is covered against Accidental Damage to her building and contents caused by storm and rainwater that this cover is subject to the flood exclusion. 17. The FSP states that it received notification from the Applicant of damage to her property first on 7 January 2011. The FSP notes that on 6 and 7 January 2011 that 17.4mm and 33.4mm fell respectively. At 10.15am on 10 January 2011 the Ap plicant informed the FSP that „water was entering her home now‟. The FSP then received a telephone call from the Applicant on 11 January 2011 stating there was further damage with water rising up the walls a „couple of feet‟. 18. The FSP notes that any inundation which occurred on 7 January 2011 would have been much less than 10 January 2011 inundation. 19. The FSP contends the hydrology information demonstrates that the stormwater run-off was insufficient to exceed 300mm of the ground floor unit inundation. Further that the water damage over that watermark and to the two elevated houses was caused by overflow from Sandy Creek. 20. There is no evidence that damage was caused by overflowing gutters, roof or stormwater run-off. 21. The FSP notes the Applicant has indicated backflow from stormwater drains at the front of the property. It is clear from hydrological evidence that many storm water drains exit into a river/creek system. In such a situation the river level rises above the storm water outlet and a backflow occurs in which the river water flows back up the stormwater drainage and discharges onto the property. 22. The FSP contends that the inundation was either river water or a mixture of river and stormwater. The FSP therefore contends that only when there is storm water, independent of flood water, that inundates the premise and causes damage will it be covered. However in circumstances where water inundates a premise along with flood waters, the damage arises from flood and is excluded from cover. The FSP relies on case law such as K Sika Plastics v Cornhill Insurance, Peterson v Union Des Assurances De Paris IARD and Wayne Tank and Pump Co Limited v Employers Liability Assurance Corp Limited. Issues 23. Whether the FSP has appropriately declined the balance of the Applicant‟ s claim for loss arising from the inundation of the property. Reasons for Decision 24. There has been an exchange of material between each party, and the Panel is satisfied each party has had an opportunity to reply to the issues raised. Case No: 242780 Determination Page 8 of 12 25. This Determination will be made by a Panel consisting of a Panel Chair Ombudsman, a representative with extensive experience in the insurance industry and a representative with extensive experience of consumer claims. 26. The Panel has read each party‟s submissions and materials a nd will only refer to the relevant submissions and materials raised. 27. The parties do not dispute that stormwater run-off, independent to the Sandy Creek source of water, has inundated the property up to 300mm. The issue for the Panel is the extent of damage caused by stormwater inundation and the level of that inundation. 28. The Panel notes the FSP has stated the Applicant made a claim for damage arising on 7 & 10 January 2011. However, there are no claim file records which demonstrate this occurred and the information provided all relates to 10 January 2011. 29. In view of the complexities associated with this dispute, a site inspection was conducted by the Panel Chair Ombudsman. Present at the inspection were the Applicant and representatives from the FSP. 30. A number of issues arose in the course of the site inspection. The FSP advised that they had arranged an engineer to inspect the property as they were still assessing the Applicant‟s claim with respect to the initial inundation and the extent of damage caused by the inundation to 300mm to the ground floor unit. A copy of the engineer‟s report was not available and it is unclear from the information provided why this assessment was arranged, given the dispute before the Financial Ombudsman Service relates to the level of inundation and consequent damage sustained. 31. The FSP suggested that this engineer‟s report followed the acceptance of the claim in March 2011 with respect to the damage to the ground floor flat. The FSP could not explain why it had taken the best part of nine months to arrange for this further assessment. 32. The Panel notes this was not raised by the FSP when providing the Notice of Response. The FSP‟s representative suggested that the further assessment was to determine the extent of the damage sustained by inundation by 300mm as a result of the Applicant providing a series of quotes. The Panel notes in the material exchanged, a loss schedule that had been prepared by the FSP‟s loss adjustor and a number of quotes dated 4 February 2011. These quotes were provided to the loss adjustor by the Applicant. 33. The Applicant advised that on inception of the policy she had specifically requested that cover be provided for her parents, her sister and her contents as there were three properties being insured under the one policy. The Applicant advised that she was informed by the FSP that neith er her parents‟ nor sister‟s contents were covered under the policy. This is not referred to in the material exchanged although the Applicant was adamant that this was raised with the FSP on a number of occasions and as recently as the day prior to the site inspection confirmed by the FSP. Case No: 242780 Determination Page 9 of 12 34. The FSP‟s representative confirmed that he had conduct of this dispute and confirmed that the policy did in fact cover the contents on the insured property owned by the Applicant, her sister and parents. 35. Finally, with respect to the initial acceptance letter, the Panel notes that letter refers to water having inundated the ground floor unit to 300mm. The Panel notes that the unit is built under the main residence. The main residence is elevated on wooden stumps. There was the significant amount of furniture and other items stored on the ground level beside the unit. In fact the ground floor unit took up an area which would less than 25 percent of the ground floor area under the main residence. 36. As identified by the FSP‟s assessor, the properties are at the base are of a very high escarpment or bluff and water from the town would have swept down to the area and flowed along the gully. Water would also have come from the street in front of the house which was much higher than the property. To the naked eye the crest of the road running at the front of the Applicant‟s property would be about 2 metres higher than the gully, possibly more. 37. The Applicant has given evidence that it rained substantially on the day of the inundation and that water was flowing in from the street and into her property. The water was ankle deep when the emergency services advised her to evacuate and then the water rose within minutes to 900mm deep at the time of evacuating. Sandy Creek had not over-topped the embankment at the time of evacuating. The Applicant then returned 2 hours later to discover the water had receded. 38. The Applicant explained that the water to the main dwelling caused limited if any damage above floor level. Inundation to the granny flat caused some damage with parts of the floor “popping”. Kitchen cupboards had swollen although they had not yet been replaced. There is also significant damage to the fenc es surrounding the property including a ‟cat barrier‟. 39. Within the material exchanged there is a quotation for repair of the external fencing. The FSP‟s representative indicated that the external fencing would be covered under the terms of the policy however, looking at the terms of the policy, the Panel notes there are certain restrictions with respect to this. The FSP does not appear to have addressed the question of damage to the fencing in the material exchanged. 40. The FSP agreed that inundation up to 300mm of the ground floor unit would have been stormwater run-off independent of any flood water. However, it has submitted that the balance of the damage was caused by flood water from Sandy Creek. The FSP bases its partial declinature on the hydrologist‟s re port. 41. Accordingly, the Panel accepts that a prima facie case for damage arising from stormwater damage has been established by the Applicant. Further, that the FSP has accepted this with a caveat that damage above 300mm was due to flood inundation which is excluded by the policy. Case No: 242780 Determination Page 10 of 12 42. The evidence before the Panel suggests that whilst the insured property is not within a noted watercourse that it does sit in an old „relic channel‟ of Sandy Creek. This gully naturally functions as a local drainage network that directs run- off into Sandy Creek via the Applicant‟s property. The Panel considers this would support the Applicant‟s observations that water was running down the street and into the property. In fact the video evidence provided to the Service also supports this observation from the Applicant. 43. The Panel notes the hydrologist‟s report does provide rainfall data but not for the local hourly rainfalls during the relevant period. 44. The Panel further notes that the hydrologist has not provided information regarding the river gauges and what times the Sandy Creek would have risen. The Sandy Creek (a tributary of Esk Creek) sits above the point of release for the Wivenhoe Dam but is within the catchment area of the Wivenhoe Dam. This suggests that the location would have received significant rainfall run-off but was not affected adversely by the releases into the Brisbane River. 45. The evidence provided by the hydrologist does not properly match the physical observations of the Applicant. The Applicant observed that the water rose in minutes rather than hours from ankle deep to 900mm in circumstances where the creek had not overtopped the embankment and then receded in 2 hours. This contradicts the hydrologist‟s statement that the water rose over hours due to the Sandy Creek over-topping its banks. 46. It is unclear to the Panel on what basis the hydrologist has determined the creek overtopped its banks and inundated the property at the same time as the stormwater run-off suddenly hit the property. There is simply no evidence as to the timing of any over-topping of the banks by the Sandy Creek or its peak levels during the relevant days and hours. 47. There is no evidence as to how or why the FSP has limited the acceptance of the claim to damage to 300mm in the granny flat alone. At the very least damage through that level would have impacted on the entire ground floor level of the main residence including the air conditioning and other furnishings stored in that area. It would have impacted upon the foundations of the main residence. 48. There is insufficient evidence as to when the Sandy Creek would have overtopped its banks and inundated the Applicant‟s property. There is simply no time based rainfall data or river gauge data which would assist in calculating the relevant peak and effect of each potential inundation source and the timing of same. Accordingly, it is difficult to determine the basis of the hydrologist‟s opinion that flood inundation occurred at the same time as the storm water run- off. 49. The Panel notes the loss adjustor, having viewed the direction of trees and other vegetation and debris, considered the water flowed from the highest part of the town to the Applicant‟s property and then to the north along the gully that is behind the property. The Panel notes the loss adjustor concluded the damage was a result of inundation of water from the rain and storm water run- Case No: 242780 Determination Page 11 of 12 off covered under the terms of the policy. The loss adjustor considered the water deep enough and flowing fast enough to do significant damage to the home, completely sweeping away the flat underneath the home destroying all of the walls, flooring, plumbing, fixtures and electrical systems. The Panel also notes the view of the hydrologist that the peak rainfall intensity would have been sufficient to overwhelm the local drainage system. 50. As this is an accidental damage policy, the FSP bears the onus of establishing the application of the exclusion, once the Applicant has established on balance the claim falls within the terms of the policy. The Panel is satisfied that the Applicant established this, but is not satisfied that the FSP has established the operation of the flood exclusion should apply to inundation above 300mm. 51. The Panel is satisfied following the site inspection that the inundation of the second level of the main residence would most likely be due to a combination of flood and stormwater and therefore excluded under the terms of the policy. The Panel is not satisfied the evidence is sufficient to establish the flood exclusion would apply to the balance of the claim, including the damage through the unit, ground floor level of the main residence, granny flat, fencing and air conditioning. 52. The Panel notes that there are reports regarding the structural damage to the insured buildings and the uncertain quantum regarding this damage. The Panel also notes there is some confusion as to the extent of cover and confirms that the FSP accepts that liability extends to cover not only damage to the buildings on the property, but also to the contents owned by the Applicant, her parents and sister that were damaged and/or lost as a result of the inundation of the property. Determination 53. On the basis of the available information, the Panel determines that the FSP is liable to pay the claim on the basis that the damage was caused by stormwater inundation, save for the damage to the second level of the main residence. 54. The FSP is directed to urgently complete an assessment of the damage and establish the extent of the loss. In this regard the Panel notes the FSP has recently had an engineer assess the property. 55. The FSP is to settle the claim subject to the terms of its policy. The Panel confirms the FSP accepts that the policy extends to cover the loss of contents owned by the Applicant, her sister and parents stored at the property. 56. Insofar as the FSP determines that it is to cash settle parts of this claim, the FSP is to pay interest in accordance with section 57 of the Insurance Contracts Act (1984) from 17 March 2011 to date of payment of this claim. Case No: 242780 Determination Page 12 of 12 57. In settling the claim, should there be dispute as to the extent of the contents lost; the parties are asked to work cooperatively to determine that loss.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.