Home / Financial Firm (Unknown - Insurer) / Determination 238748

Determination 238748

Hail storm damage: claim partly declined under gradual deterioration exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2011-11-22
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

Hail storm damaged the applicant's home and the FSP denied part of the claim. AFCA ordered the FSP to pay for repairs to the laundry wall and rear access door but not the rotten timber piers.

Once the applicant shows a prima facie insured loss, the insurer must prove an exclusion; the rot in the piers was gradual deterioration, while the storm caused the wall failure.

Issues

Subjects and remedies

home or building damagenatural disasterpay claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 238748 Determination Page 1 of 8 Case Number: 238748 General Insurance – Home Building and Contents Insurance – Hail storm damage – Policy exclusions – Wear, tear and gradual deterioration 15 November 2011 Background 1. The Applicant insured his home building and contents for $479,000 and $154,500 respectively, against loss or damage caused by insured events. The policy was current for the period 10 December 2009 and 10 December 2010. 2. On the 6 March 2010, the Applicant ‟s property was severely damaged during a hail storm. The Applicant states that damage was caused to a laundry wall, ceilings, carpets, underlay, furniture, and laserlite roof sheets. He also contends that a rear door has also „dropped‟. 3. The Financial Services Provider (FSP) accepted liability for the majority of the damage but denied indemnity for damage to timber floor stumps, laundry wall and rear door on the grounds that the damage was caused by wear, tear and gradual deterioration. 4. The Applicant contends that water had flooded under his house causing damage to the stumps and the weight of the hail on the flat skillion roof also caused damage to the building. Summary of Applicant ’s Position 5. The FSP has refused to accept liability for the cost of repairs to a laundr y wall. There was a hairline crack before the hail storm, however, after the storm the crack was approximately 3mm wide and the rear door had dropped. 6. The FSP commissioned two independent reports . One report stated that damage was related to the storm. The other report stated that whilst there appeared to be pre-existing rot on one stump, the storm probably was the „straw that broke the camel‟s back‟. 7. The writer of the second report was of the opinion that he suspected rot was in a number of stumps and this was the cause of the damage to his house and not the storm. Determination Case No: 238748 Determination Page 2 of 8 8. The Applicant had a detailed assessment undertaken by a qualified civil and structural engineer who reported:  A soil analysis supports the view that minor „hairline‟ cracking would be expected in his property on the basis of moisture variability over time;  In respect to the crack over the laundry door being caused by settlement or deterioration of nearby stumps, there is no evidence of any vertical movement in any wall or joinery surfaces;  One of the walls associated with the area of the crack over the laundry door has a very large tiled surface and there is no evidence of any cracking in the tiles, which would be expected if one „side‟ of the wall had dropped due to stump settlement;  The 3mm crack in the wall is the same amount that the wall is displaced horizontally; the engineer‟s assessment is that the crack is consistent with horizontal movement and not vertical movement;  The crack is caused by horizontal movement due to the swelling of the ti mber associated with the „top plate‟ of the wall frame; o This is consistent with the excessive rainwater that entered the ceiling cavity at this location; o Damage caused to the plasterboard ceiling at this location has already been accepted as storm related damage by the FSP; 9. While the Applicant accepts there is most likely stump deterioration as identified by the FSP‟s engineer, with the benefit of an additional structural assessment this would appear to be a „red - herring‟. The crux of the matter is whether the crack over the laundry door is due to horizontal or vertical movement. 10. In the Applicant ‟s opinion, based on an examination of both engineering reports, and a physical examination of the area, there is no doubt that the cracking is horizontal. 11. This conclusion is supported by the fact there is a lack of cracking of any of the tiled wall associated with where the FSP‟s engineer‟s report claims the settlement is due to stump deterioration. 12. The Applicant ‟s structural engineer reported:  The soils at this location fit with a “Newer Volcanic” profile which is reactive to different moisture conditions. These soils do not react immediately to surface water, but with time, depending upon the seasons or alternatively wet or dry periods.  The changes in soil moisture impact on structure by swelling or shrinking moisture change. This causes structure supported in the soil to move and the result shows up as minor cracking within the building.  This is evident in the Applicant ‟s building. Case No: 238748 Determination Page 3 of 8  The kitchen corner and associated displacement of wall/plaster cracking is not associated with soil moisture change, nor does it appear to be due to settlement of sub-floor framing.  There is no obvious indication of movement in any wall or joinery surfaces, which would be expected with framing settlement.  It was his opinion that moisture in the skillion roof area ceiling/wall/roof framing is the source of the Applicant ‟s concerns and that in some way swelling of timbers has caused the horizontal displacement that is so obviously evident.  The roof interface between tiles and metal sheeting is deficient and has potentially been a source of moisture entry since the day it was constructed.  This interface needs to be correctly flashed and timber roof/wall members investigated for moisture/water damage/rot.  He believes the area of concern has been a long term issue and there is every chance that is has been exacerbated by significant water ingress into the skillion roof area during the storm event. 13. In attempting to resolve this dispute, based on his engineer‟s a ssessment, he contends that in conjunction with the FSP‟s agreed position of repairing/replacing the water damaged ceiling and cornice in this area, as part of this work the associated top plate be inspected and repaired as required. Once this is done the ceiling/wall/ cornice plaster work can then be completed. 14. In a later submission the Applicant stated that “I‟m not at any stage making a claim against (FSP) for any of the pre- existing “hairline cracks that I have in various parts of the house”. He accepts these are a result of a decade of semi - drought in a weather bound house supported mainly by timber stumps. Summary of FSP’s Position 15. The FSP‟s external loss assessor appointed a builder to attend the storm damaged property and provide quotations to rectify the damage. The builder authorised to carry out repairs advised that he did not believe the cracking to the walls to have been caused by the storm. 16. As a result, building consultant “S” was appointed to attend the property and determine the cause of the damage. S advised in their report that they believed the damage to have been caused by the storm. In a report dated 13 July 2010, S stated in his summary: “I am of the opinion that the cracking to the wall lining over the laundry door, and the rear sliding access door not being able to shut correctly is the result of pier movement to the under floor space. I consider the movement to have resulted from substantial stormwater flowing under the residence soaking the ground around the piers, which in recent years have not been affected by such water ingress. Therefore I consider this to be the result of storm activity on the 6 th March 2010. Case No: 238748 Determination Page 4 of 8 It is my recommendation that for the repair of the damage the piers should be packed below the doors to the laundry and the rear entrance to allow them to shut correctly. When this is carried out patching, preparation and painting of the affected walls will rectify the damage.” 17. However, the report provided by S had been prepared by a building consultant and not a structural engineer. Therefore, the FSP appointed a structural engineer, “M” to inspect and report on the cause of the internal cracking to the building. 18. The structural engineer‟s report dated 19 August 2010, stated:  The laundry area and the external wall containing the rear access door are supported on timber stumps. The damage has been caused by the settling under the damaged areas.  The floor frame is partially supported on timber stumps and partially on a concrete slab that may or may not be correctly engineered. This variation in supporting structure can cause problems as each reacts differently to changes in foundation soil conditions.  An inspection under the house revealed that the soil is very dry in most areas including the majority of the stump positions. This indicates that water did not flood under the entire house.  He accessed the timber stumps under the kitchen/family room area. The corner is supported on one stump which is rotten 100mm below ground level. Inspection of other stumps found some in similar condition. He believes these stumps were not replaced 25 years ago, when restumping had occurred, due to access difficulties.  He could not access the stumps under the rear access door but assumed they would be in need of replacing based on the damage to the door opening.  He noted that the Applicant had informed him that pre-existing cracks became worse after the storm. He believed this was due to the ability of the wall structure to span over the damaged stumps under regular loading conditions.  However, he considered the hail storm would have added extra load from the hail build-up on the flat skillion roof.  The damaged wall carries the load from the skillion roof and also part of the pitched roof of the original section of the house. That area was also damaged by the ingress of water from the build-up of ice.  Even though the damage could be perceived as being exacerbated by the extra load from the storm, it really was just the „straw that broke the camel‟s back‟. Case No: 238748 Determination Page 5 of 8  The rotten stump is the cause of the damage.  The engineer recommended that an experienced re-blocker be appointed to inspect all stumps and replace those that are rotten and re- level the house. 19. The FSP states that its policy of insurance is a defined events policy. The finding of the structural engineer is that the proximate cause of the cracking is due to the rotting of the stumps which is not a defined event under the terms and conditions of the policy. 20. The proximate cause determined by the structural engineer would justify a general exclusion under the policy. Accordingly, the FSP does not accept the Applicant ‟s requested resolution to repair the crack and share in the cost of replacing the rotting stumps. 21. The FSP relies on the following policy/contract provisions: “What you are not covered for Like most insurance policies, there are general exclusions that apply to all covers. You are not covered for any loss or damage caused by or resulting from: ...  gradual deterioration, including wear and tear, rust, corrosion, depreciation, fading or deterioration from exposure to light;  mould or mildew, wet or dry rot, rising damp or dampness;  inherent defects, structural faults, faulty workmanship or faulty design;  poor maintenance and failure to maintain the property in good repair;  ....” Issue 22. Whether the damage to the Applicant ‟s property w as caused by an insured event within the policy of insurance. 23. Whether the FSP is entitled to rely on a policy exclusion to deny indemnity for the Applicant ‟s claim. Reasons for Decision The onus of proof is on the Applicant to establish, on the balance of probabilities, that he has suffered a loss caused by a risk insured against. Once the Case No: 238748 Determination Page 6 of 8 Applicant has established that the loss was prima facie caused by a risk insured against, the onus shifts to the FSP to show, on the balance of probabilities that the loss falls within an exclusion in the contract of insurance. There has been an exchange of material which the parties rely on. Each party has had access to the material on which the other party bases its case. As a consequence, it is not necessary to go into all of this material in any great detail. 24. The two areas subject to this dispute are repairs to the cracked laundry wall and the dropped rear access door and repairs/replacement of damaged timber stumps under the affected laundry and rear access door. 25. Initially, the FSP appointed a building consultant, “S” to inspect and report on the damage to the insured house. S reported on the 13 July 2010 that the cracking to the wall lining over the laundry door and the rear sliding access door was the result of pier movement under the floor space. 26. He considered the movement resulted from the substa ntial stormwater flowing under the house soaking the ground around the piers. 27. The FSP followed up this opinion within a report from a structural engineer “M” . In his report dated the 19 August 2010, he found that the damage to the insured building was caused by the settling of the stumps under the damaged areas. 28. M inspected under the floor space and reported that the soil was very dry in most areas including the majority of the stump locations. It must be borne in mind that his inspection was nearly six/seven months after the storm. 29. The Applicant appointed a structural engineer to inspect and report on the damage. In an undated report, the engineer stated:  the damage was not associated with soil moisture change nor did it appear to be due to settlement of sub-floor framing;  it was his opinion that moisture in the skillion roof area is the source of the damage that in some way swelling of timbers has caused the horizontal displacement that is evident;  the roof interface between tiles and metal sheeting is deficient and has potentially been a source of moisture since the day it was constructed;  he believed the area of concern „ has been a long term issue and there is every chance that it has been exacerbated by significant water ingress into your skillion roof area during the storm event...’ (my emphasis) 30. If I accept the Applicant ‟s engineer‟s opinion , I would have to consider the effect of the policy general exclusion as to damage caused by gradual deterioration. Further, there is no evidence that the engineer inspected the floor space under the house to ensure there was no damage to any timber piers. Case No: 238748 Determination Page 7 of 8 31. Building consultant S stated that the damage to the house was caused by pier movement under the house as the result of stormwater flowing under the house. However, it appears that S also did not carry out a thorough inspection of the piers as to whether there was any rotting to the piers. 32. S‟s recommendation to repair the damage to the piers was to pack the p iers below the door to the laundry and the rear access door. 33. Structural engineer M dug around some of the timber piers and discovered that they had been affected by rot. I accept that he was not able to access all the relevant timber piers. I also accept that by the time of M‟s inspection the soil may have dried out. It is possible that both S and M are correct. 34. The Applicant accepts that there is most likely stump deterioration, however, he contends that engineer M‟s assessment was a „red - herring‟. 35. A critical aspect is that the Applicant has stated that the crack in the laundry wall was minor until the storm event when the crack increased in width. Engineer M was of the opinion that the pre-existing cracks were minor because of the ability of the wall structure to span over the damaged stumps under regular loading conditions. 36. However, the build up of hail from the storm on the 6 March 2010 added extra load on the skillion roof. The Applicant has estimated that the additional weight would have been approximately 2.7 tonnes of additional roof loading that the house was not designed to carry. The un-contradicted evidence as to the connection in time between the storm and the damage to the laundry wall is a strong factor in support of this claim. 37. The Applicant considers that the additional weight plus the significant water under the house during the storm had been enough to cause the damage. However, the Applicant ‟s structural engineer was of the opinion that the cracking to the plaster was not associated with any soil moisture change. 38. On the evidence submitted, I am persuaded that some of the timber piers suffered rot which occurred over a long period of time and their condition was a factor in causing the damage to the laundry wall and rear access door. 39. Engineer M has stated that before the hail storm occurred, the ability of the wall structure to span over the damaged stumps prevented major damage to occur. It was only the weight of the hail that caused the wall structure to fail. 40. This means that one proximate cause was followed by another so that they were consecutive not concurrent. Case No: 238748 Determination Page 8 of 8 Determination 41. Therefore, I find that the Applicant suffered a loss due to the storm which falls within the cover provided by the policy of insurance. 42. However, I also find that the damage which falls with the policy cover is limited to the laundry wall and rear access door. The Applicant has not persuaded me that the damage to the timber piers was not the result of gradual deterioration which is excluded from the cover provided by the policy. 43. Accordingly, I determine that the FSP is entitled to deny liability for the replacement of the timber piers, but is liable for the cost of repairs to the laundry wall and rear access door.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.