Claim declined under inherent defect and corrosion exclusions for sea water strainer bolt failure

FirmFinancial Firm (Unknown - Insurer)
Decided2011-07-28
ProductGeneral Insurance · Boat
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$107,052
SourceAFCA PDF

Summary

The applicants claimed for repair costs of a power catamaran that sank after a corroded and defective strainer bolt failed. AFCA found the insurer could rely on the inherent defect exclusion and that section 46 of the Insurance Contracts Act did not override it, so nothing was ordered.

Section 46 of the Insurance Contracts Act does not displace an exclusion that does not refer to the condition of the thing before the contract was entered into.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 236136 Determination Page 1 of 9 Case number: 236136 General Insurance – Marine Pleasure Craft – Accidental damage – policy exclusions – Inherent defects, corrosion - Section 46 of the Insurance Contracts Act 28 July 2011 Background 1. The Applicants insured their 2008 Montebello Power Cat under a Marine Pleasure Craft Insurance policy against accidental loss or damage. 2. On 2 November 2010 the vessel was moored at a pier when it was found to be listing to starboard. The Applicants were interstate at the time and a friend arranged for the Fire Brigade to attend. 3. When the Fire Brigade arrived, they found the vessel partially submerged. The Fire Brigade pumped the vessel dry, located the fault and shut the seawater inlet cock off. 4. The Applicants‟ friend contacted a mari ne services firm to inspect the vessel and whose (undated) report stated, in part,: 5 “On board I found that the sea water strainer was the cause of the problem. The retaining bolt holding the cover plate on, corroded and broke off, causing the vessel to sink. The water level had flooded over the deck on the stb side filling the engine room with salt water.” 5. The Financial Services Provider (FSP) appointed a marine surveyor, “L”, to inspect and report on the damage to the vessel and the cause. In his email report dated 18 November 2010, “L” stated: 7 “ Cause 8 The bolt that is the hinge for the retaining bracket that locks the lid of the strainer on the starboard side raw water strainer has parted under tension allowing the seal to fail on the lid gasket with salt water flooding the engine room. 9 It would appear that the bolt in question is most likely not 316 stainless steel and appears to have sustained corrosion eventually causing it to fail. In our opinion this corrosion has most likely occurred due to unknown grades of stainless steel being used in construction of the strainer. This may have occurred at the supply source of the material or at the time of manufacture of the strainer however where this occurred is unlikely to be determined.” Determination Case No: 236136 Determination Page 2 of 9 6. The cost of repairs to the Applicants‟ vessel has been estimated to be $107,052.40. 7. Relying on “L‟s” report, the FSP denied indemnity t o the Applicants on the ground that the cause of the damage to the insured vessel was corrosion and/or an inherent defect of the bolt, which are excluded from the cover provided by the policy. 8. The Applicants disputed the FSP‟s decision contending that there is no conclusive proof that the offending bolt failed because of corrosion or inherent defect. Further, the Applicants rely upon section 46 of the Insurance Contracts Act 1984 (the Act) to defeat the effect of the policy exclusion. Summary of Applicants ’ Position The Applicants‟ submission has been prepared by their legal adviser who will be referred to as the „Applicants‟. 9. The Applicants contend that the FSP‟s marine surveyor‟s report is speculating as to the cause of the failure of the bolt. They state that the surveyor is unable to definitively state, what appears to have been corrosion, and how this was caused. The FSP deems the most likely cause of what appears to have been corrosion to be an inherent defect. 10. The sea water strainer is a complete unit which includes the bolt which the FSP states, appears to have corroded. The vessel was built in 2008, they purchased it in early 2010, and they have endeavoured to maintain it in excellent condition. Had any component of the vessel been the subject of any identifiable corrosion, they would have repaired it. 11. The Applicants state that had there been any capacity to identify the potential failure of the bolt as an inherent defect, it would have been replaced by them. Further, it cannot be held that a bolt that „appears to have corroded‟, without any possibility of identifying that corrosion was occurring, could be an inherent defect. 12. There is no possibility that the Applicants could have been aware that the bolt was likely to fail. There was no process which they could have undertaken to enable them to anticipate and take preventative action against what occurred. 13. The FSP‟s marine surveyor‟s opinion that it would seem that the bolt appears to have sustained corrosion eventually causing it to fail is manifestly incorrect. The metallurgist appointed by the Applicants provided the only independent scientific analysis of the bolt and reported that it failed by inter-granular attack in the heat affected zone of a weld on the bolt end because the steel quality of the bolt was poor. 14. Their metallurgist‟s report dated 12 January 2011, stated, in part: „Visual Inspection Case No: 236136 Determination Page 3 of 9 The stainless steel strainer cover assembly Fig 1 had been held in position on the left-hand side as viewed, by a 9.5mm (3/8 inch) diameter stainless steel threaded bolt that ran through the tube on the hold-down frame. The bolt had fractured inside the tube at the bottom end. When it was removed, some surface corrosion was evident to the fracture adjacent to the fracture and also some longitudinal grooving., Fig 2. None of this could have been seen while the bolt was in position inside the tube. Fracture surface appearance was heavily oxidized, Fig 3. ... Conclusions 1. The bolt was a grade of non-magnetic stainless steel. 2. It had failed by intergranular attack in the heat-affected zone of a weld on the bolt end. The weld thermal cycle had sensitised the steel to attack. 3. Steel quality of the bolt was poor with heavy segregation bands and also grain boundary carbide networks throughout the microstructure.‟ Section 46(2) of the Act supports their position that the FSP cannot rely on the policy exclusion to deny indemnity. The A pplicants‟ claim is made in respect of a loss that occurred as a result, in whole or in part, of a defect or imperfection in a thing, namely, the bolt. 15. The steel quality of the bolt was poor, that is, imperfect. It failed by inter - granular attack in the heat affected zone of a weld on the bolt end. The bolt was both defective and imperfect. 16. They contend that the imperfection/defect in the bolt existed from the date of manufacture of the sea water strainer. It was manufactured with an imperfect/defective retaining bolt holding the cover plate on. 17. The imperfection/defect predated the date upon which the contract of insurance was entered into and it is acknowledged that the Applicants were not aware of, and a reasonable person in the circumstances could not be expected to have been aware of the defect or imperfection. 18. Therefore, the FSP may not rely on a provision included in the contract that has the effect of limiting or excluding the FSP‟s liability under the contract by reference to the condition, at the time before the contract was entered into, of the bolt. 19. The imperfection/defect obviously existed at a time before, and when, the contract was entered into. The only condition upon which the FSP relies to deny the claim is a condition which existed before the contract was entered into. 20. Section 46 exists to protect people who insure their vessel in good faith without the possibility of knowing that their vessel contains an inherent defect or imperfection. Case No: 236136 Determination Page 4 of 9 21. The Applicants contend that it would be grossly unfair if the FSP could decline claims for damage to their vessel arising as a result of defects within the vessel of which no reasonable person could be expected to have knowledge. 22. Further, it would be grossly unfair if the FSP could rely upon an obscure and unduly restrictive interpretation of the intended meaning of section 46 of the Act when it clearly exists for the purpose of protecting insured‟s in the predicament in which the Applicants find themselves. 23. The Applicants contend that the FSP should indemnify them for the costs of repairing their vessel. Summary of FSP’s Position 24. The FSP contends that it is not in dispute that the defect that caused the bolt failure was an inherent one. 25. Its policy of insurance excludes loss or damage caused by or resulting from, or costs incurred from or of:  wear and tear or corrosion; and  inherent defects. 26. The policy does not define „corrosion‟ but the Concise Oxford English Dictionary (eleventh edition, revised) states: „ Corrosion n. the process of corroding or being corroded‟ „Corrode v. (with reference to metal or other hard material) destroy or be destroyed slowly by chemical action. Gradually weaken or erode.‟ 27. The FSP contends that its policy is written in plain language and is clear and unambiguous. The policy clearly informs the Applicants that general exclusions apply to all covers. 28. Its marine surveyor reported: “Cause The bolt that is the hinge for the retaining bracket that locks the lid of the strainer on the starboard side raw water strainer has parted under tension allowing the seal to fail on the lid gasket with salt water flooding the engine room. It would appear that the bolt in question is most likely not 316 stainless steel and appears to have sustained corrosion eventually causing it to fail. In our opinion this corrosion has most likely occurred due to unknown grades of stainless steel being used in construction of the strainer. This may have occurred at the supply source of the material or at the time of manufacture of the strainer however where this occurred is unlikely to be determined.” 29. The Applicants‟ metallurgist reported that: Case No: 236136 Determination Page 5 of 9  the bolt was fractured inside the tube...When it was removed some surface corrosion was evident;  the steel quality of the bolt was poor. 30. It is not disputed by the Applicants or the FSP that corrosion was evident or that the inherent quality of the steel used in the manufacture of the bolt was responsible for the damage. 31. Although the Applicants were not aware of the inherent defect of the bolt either at the time of purchase of the vessel, or at inception of the policy, it remains a fact that the bolt had corroded and the inferior metal used in its construction was an inherent defect. 32. Therefore, the FSP contends that the general exclusions of „corrosion‟ and „inherent defects‟ can be applied to the circumstances of the Applicants‟ claim. Section 46 of the Insurance Contracts Act 1984 (the Act) 33. Section 46 of the Act provides: “ that if a claim is made in respect of a loss that occurred in whole or in part as a result of a defect or imperfection in a thing and the insured was not aware of the defect or a reasonable person in the circumstances could not be expected to have been aware of the defect or imperfection, the insurer may not rely on an exclusion clause that refers to the condition of the thing before the contract was entered into. ” 34. The Applicants have sought relief from the policy exclusions by relying on section 46 of the Act. 35. The FSP contends that there are two alternative reasons why section 46 of the Act does not apply. 36. Firstly, the FSP refers to the decided case of Nelson v The Hollard Insurance Company Pty Ltd [2010] NSWSC 199 (on appeal). 37. The Court held that section 46 of the Act does not apply to an exclusion of an event which makes no reference to when the event occurs. That court has determined that the application of section 46 has to take place in relation to the wording of the policy and not the particular facts of the case. 38. Therefore, only those exclusions which refer to a condition existing before entry into the contract are affected by section 46. The FSP also refers to Asteron Life Limited v Zeiderman [2004] NSWCA 47. 39. The exclusion in the FSP‟s contract of insurance refers to „inherent defects‟ without reference to the inherent defects arising or existing prior to the contract being entered into. Therefore, as the exclusion does not refer to a pre- contractual condition, section 46 of the Act cannot be relied upon by the Applicants. 40. Therefore, the FSP is entitled to rely on the exclusions contained within the policy wording that excludes its liability. Case No: 236136 Determination Page 6 of 9 41. The second alternative ground for section 46 not applying is that ‟corrosion‟ is neither a defect nor an imperfection, but rather a process that is ongoing. 42. The Concise Oxford English Dictionary defines „corrosion‟ as:  “Defect n. a shortcoming, imperfection, or lack‟  Imperfection adj. Faulty or incomplete.” 43. What both of these definitions have in commo n is that they refer to a fixed state of affairs or a final outcome, not a continuing process. It follows that the „corrosion‟ exclusion, describing a process, falls outside of section 46 of the Act. 44. The Applicants contend that the FSP‟s marine surveyor‟s opinion that corrosion eventually caused the bolt to fail is manifestly incorrect. They submit that their metallurgist stated that the bolt failed due to inter-granular attack. 45. The FSP refers to an extract from Perry‟s Chemical Engineers‟ Handbook by Don W Green and James O Maloney 7 th ed., 1997, which states: „ Intergranular corrosion (IGC), also known as intergranular attack (IGA), is a form of corrosion where the boundaries of crystallites of the material are more susceptible to corrosion than their insides, (Cf. Transgranular corrosion) ‟ 46. Therefore, when the Applicants‟ metallurgist was referring to „inter -granular attack‟ he was referring to what is also commonly known as „inter -granular corrosion‟. 47. The Applicants have also stated that it would be grossly unfair for the FSP to rely upon an obscure and unduly restrictive interpretation of the intended meaning of section 46 of the Act, when it clearly exists for the purpose of protecting insured‟s in the predicament the Applicants find themselves. 48. The FSP contends that it has relied upon the findings of the Supreme Court of NSW in the Nelson (on appeal) and Asteron Life cases where the principle to be applied by the Court has been the subject of detailed and thorough submissions and arguments. 49. The FSP contends that based on all the available evidence, it submits it has correctly applied the terms, conditions and exclusions of the policy to deny indemnity to the Applicants for their claim. 50. Further, the FSP‟s final decision in this matter was made with full reg ard to section 46 of the Act and the cited legal principles derived from case law. 51. The FSP relies on the following policy/contract provisions: “General exclusions Like most insurance policies, there are general exclusions that apply to all covers. You are not covered for any loss or damage caused by or resulting from, or the costs incurred from or of: Case No: 236136 Determination Page 7 of 9  ...  wear and tear, mould, gradual deterioration, timber rot, delamination, vermin, corrosion, electrolysis, osmosis or marine growth;  inherent defects, structural faults, faulty workmanship or faulty design;” Issues 52. Whether the FSP is entitled to rely on the policy exclusions to deny indemnity to the Applicants for their claim. The onus rests on the FSP to establish that, on the balance of probabilities, the cause of the damage to the Applicants‟ vessel was the result of an excluded event. There has been an exchange of material which the parties rely on. Each party has had access to the material on which the other party bases its case. As a consequence, it is not necessary to go into all of this material in any great detail. Reasons for Decision Application of Policy Exclusion 53. The FSP has relied upon two policy exclusions to deny indemnity to the Applicants. Firstly, the damage to the ves sel was the result of an „inherent defect‟ and secondly, „corrosion‟. 54. Where one, or both, causes of the loss fall within an exception or exclusion clause in the contract, the insurer is not liable. Wayne Tank and Pump Co Ltd v Employers Liability Assurance Corp Ltd (1973) 3 All ER 825. Inherent Defect 55. The contract of insurance excludes loss or damage caused by or resulting from an inherent defect. The marine surveyor appointed by the FSP reported: “ The bolt that is the hinge for the retaining bracket that locks the lid of the strainer on the starboard side raw water strainer has parted under tension allowing the seal to fail on the lid gasket with salt water flooding the engine room. It would appear that the bolt in question is most likely not 316 stainless steel and appears to have sustained corrosion eventually causing it to fail. In our opinion this corrosion has most likely occurred due to unknown grades of stainless steel being used in construction of the strainer. This may have occurred at the supply source of the material or at the time of manufacture of the strainer however where this occurred is unlikely to be determined.” 56. The Applicants appointed a metallurgist to investigate the cause of the bolt failure. In a report dated 12 January 2011, he stated: Case No: 236136 Determination Page 8 of 9 „Visual Inspection The stainless steel strainer cover assembly Fig 1 had been held in position on the left-hand side as viewed, by a 9.5mm (3/8 inch) diameter stainless steel threaded bolt that ran through the tube on the hold-down frame. The bolt had fractured inside the tube at the bottom end. When it was removed, some surface corrosion was evident to the fracture adjacent to the fracture and also some longitudinal grooving., Fig 2. None of this could have been seen while the bolt was in position inside the tube. Fracture surface appearance was heavily oxidized, Fig 3. ... Cracks in the longitudinal section about 1mm behind the fracture were both trans-granular – as occurs with stress corrosion – and intergranular – typical of sensitization due to heating, see Fig. 5. Microstructure adjacent to the fracture showed heavy intergranular attack and cracks, Fig. 6. Further away from the fracture – beyond the weld HAZ, carbide grain boundary networks were evident, Fig.7. Grooves along the bolt, Figs. 2 and 4, were associated with heavy – dark etching – bands of high impurity content, Fig. 8. Conclusions 4. The bolt was a grade of non-magnetic stainless steel. 5. It had failed by intergranular attack in the heat-affected zone of a weld on the bolt end. The weld thermal cycle had sensitised the steel to attack. 6. Steel quality of the bolt was poor with heavy segregation bands and also grain boundary carbide networks throughout the microstructure.‟ 57. Therefore, on the balance of probabilities, the bolt contained an inherent defect, either through:  the bolt not being 316 stainless steel;  unknown grades of stainless steel being used in the construction of the strainer;  the bolt was of a grade of non-magnetic stainless steel;  the bolt had failed by intergranular attack; or  the steel quality of the bolt was poor with heavy segregation bands and also grain boundary carbide networks throughout the microstructure. Insurance Contracts Act 1984 The Applicants have relied on section 46 of the Act to negate the effect of the policy exclusions. They contend the fault in the bolt existed from the date of manufacture of the sea water strainer. In view of the imperfection/defect predating the commencement date of the contract of insurance the Applicants contend that they can rely on section 46 of the Act and the FSP cannot deny indemnity for their claim. Case No: 236136 Determination Page 9 of 9 The policy exclusion relied upon by the FSP states: “ You are not covered for any loss or damage caused by or resulting from, or the costs incurred from or of:...” There is no mention as to a time when the exclusion applies. The policy does not state that the exclusion applies after the contract of insurance commenced. The exclusion applies to an event that occurred at any time whether before or after the commencement of the policy. The decisions in the Nelson (on appeal) and Asteron cases have the effect of determining when sections 46 and 47 of the Act apply. That is, section 46 does not apply to an exclusion of an event which makes no reference to when an event occurs. As stated above, the FSP‟s policy doe s not state when the exclusion applies and consequently section 46 cannot provide the relief sought by the Applicants from the effects of the FSP‟s policy exclusions. Determination 58. Therefore, the Panel finds that the FSP is entitled to rely upon the „inher ent defect‟ policy exclusion to deny liability for the Applicants‟ claim. 59. Although the Applicants were not aware of, and a reasonable person in the circumstances could not be expected to be aware of, the defect or imperfection, the Panel also finds that section 46 of the Act does not provide any relief to the Applicants against the application of the policy exclusion. 60. Accordingly, the Panel determines the FSP is entitled to deny indemnity to the Applicants for their claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.