Claim declined under inherent defect and corrosion exclusions for sea water strainer bolt failure
Text of the determination
Case No: 236136 Determination Page 1 of 9
Case number: 236136
General Insurance – Marine Pleasure Craft – Accidental damage – policy
exclusions – Inherent defects, corrosion - Section 46 of the Insurance
Contracts Act
28 July 2011
Background
1. The Applicants insured their 2008 Montebello Power Cat under a Marine
Pleasure Craft Insurance policy against accidental loss or damage.
2. On 2 November 2010 the vessel was moored at a pier when it was found to be
listing to starboard. The Applicants were interstate at the time and a friend
arranged for the Fire Brigade to attend.
3. When the Fire Brigade arrived, they found the vessel partially submerged. The
Fire Brigade pumped the vessel dry, located the fault and shut the seawater
inlet cock off.
4. The Applicants‟ friend contacted a mari ne services firm to inspect the vessel
and whose (undated) report stated, in part,:
5 “On board I found that the sea water strainer was the cause of the problem.
The retaining bolt holding the cover plate on, corroded and broke off, causing the
vessel to sink. The water level had flooded over the deck on the stb side filling the
engine room with salt water.”
5. The Financial Services Provider (FSP) appointed a marine surveyor, “L”, to
inspect and report on the damage to the vessel and the cause. In his email
report dated 18 November 2010, “L” stated:
7 “ Cause
8 The bolt that is the hinge for the retaining bracket that locks the lid of the
strainer on the starboard side raw water strainer has parted under tension
allowing the seal to fail on the lid gasket with salt water flooding the engine room.
9 It would appear that the bolt in question is most likely not 316 stainless
steel and appears to have sustained corrosion eventually causing it to fail. In our
opinion this corrosion has most likely occurred due to unknown grades of
stainless steel being used in construction of the strainer. This may have occurred
at the supply source of the material or at the time of manufacture of the strainer
however where this occurred is unlikely to be determined.”
Determination
Case No: 236136 Determination Page 2 of 9
6. The cost of repairs to the Applicants‟ vessel has been estimated to be
$107,052.40.
7. Relying on “L‟s” report, the FSP denied indemnity t o the Applicants on the
ground that the cause of the damage to the insured vessel was corrosion
and/or an inherent defect of the bolt, which are excluded from the cover
provided by the policy.
8. The Applicants disputed the FSP‟s decision contending that there is no
conclusive proof that the offending bolt failed because of corrosion or inherent
defect. Further, the Applicants rely upon section 46 of the Insurance Contracts
Act 1984 (the Act) to defeat the effect of the policy exclusion.
Summary of Applicants ’ Position
The Applicants‟ submission has been prepared by their legal adviser who will be
referred to as the „Applicants‟.
9. The Applicants contend that the FSP‟s marine surveyor‟s report is speculating
as to the cause of the failure of the bolt. They state that the surveyor is unable
to definitively state, what appears to have been corrosion, and how this was
caused. The FSP deems the most likely cause of what appears to have been
corrosion to be an inherent defect.
10. The sea water strainer is a complete unit which includes the bolt which the FSP
states, appears to have corroded. The vessel was built in 2008, they purchased
it in early 2010, and they have endeavoured to maintain it in excellent condition.
Had any component of the vessel been the subject of any identifiable corrosion,
they would have repaired it.
11. The Applicants state that had there been any capacity to identify the potential
failure of the bolt as an inherent defect, it would have been replaced by them.
Further, it cannot be held that a bolt that „appears to have corroded‟, without
any possibility of identifying that corrosion was occurring, could be an inherent
defect.
12. There is no possibility that the Applicants could have been aware that the bolt
was likely to fail. There was no process which they could have undertaken to
enable them to anticipate and take preventative action against what occurred.
13. The FSP‟s marine surveyor‟s opinion that it would seem that the bolt appears to
have sustained corrosion eventually causing it to fail is manifestly incorrect. The
metallurgist appointed by the Applicants provided the only independent
scientific analysis of the bolt and reported that it failed by inter-granular attack
in the heat affected zone of a weld on the bolt end because the steel quality of
the bolt was poor.
14. Their metallurgist‟s report dated 12 January 2011, stated, in part:
„Visual Inspection
Case No: 236136 Determination Page 3 of 9
The stainless steel strainer cover assembly Fig 1 had been held in position on the
left-hand side as viewed, by a 9.5mm (3/8 inch) diameter stainless steel threaded
bolt that ran through the tube on the hold-down frame. The bolt had fractured inside
the tube at the bottom end. When it was removed, some surface corrosion was
evident to the fracture adjacent to the fracture and also some longitudinal grooving.,
Fig 2. None of this could have been seen while the bolt was in position inside the
tube. Fracture surface appearance was heavily oxidized, Fig 3.
...
Conclusions
1. The bolt was a grade of non-magnetic stainless steel.
2. It had failed by intergranular attack in the heat-affected zone of a weld on the bolt
end. The weld thermal cycle had sensitised the steel to attack.
3. Steel quality of the bolt was poor with heavy segregation bands and also grain
boundary carbide networks throughout the microstructure.‟
Section 46(2) of the Act supports their position that the FSP cannot rely on the policy
exclusion to deny indemnity. The A pplicants‟ claim is made in respect of a loss
that occurred as a result, in whole or in part, of a defect or imperfection in a
thing, namely, the bolt.
15. The steel quality of the bolt was poor, that is, imperfect. It failed by inter -
granular attack in the heat affected zone of a weld on the bolt end. The bolt was
both defective and imperfect.
16. They contend that the imperfection/defect in the bolt existed from the date of
manufacture of the sea water strainer. It was manufactured with an
imperfect/defective retaining bolt holding the cover plate on.
17. The imperfection/defect predated the date upon which the contract of insurance
was entered into and it is acknowledged that the Applicants were not aware of,
and a reasonable person in the circumstances could not be expected to have
been aware of the defect or imperfection.
18. Therefore, the FSP may not rely on a provision included in the contract that has
the effect of limiting or excluding the FSP‟s liability under the contract by
reference to the condition, at the time before the contract was entered into, of
the bolt.
19. The imperfection/defect obviously existed at a time before, and when, the
contract was entered into. The only condition upon which the FSP relies to
deny the claim is a condition which existed before the contract was entered
into.
20. Section 46 exists to protect people who insure their vessel in good faith without
the possibility of knowing that their vessel contains an inherent defect or
imperfection.
Case No: 236136 Determination Page 4 of 9
21. The Applicants contend that it would be grossly unfair if the FSP could decline
claims for damage to their vessel arising as a result of defects within the vessel
of which no reasonable person could be expected to have knowledge.
22. Further, it would be grossly unfair if the FSP could rely upon an obscure and
unduly restrictive interpretation of the intended meaning of section 46 of the Act
when it clearly exists for the purpose of protecting insured‟s in the predicament
in which the Applicants find themselves.
23. The Applicants contend that the FSP should indemnify them for the costs of
repairing their vessel.
Summary of FSP’s Position
24. The FSP contends that it is not in dispute that the defect that caused the bolt
failure was an inherent one.
25. Its policy of insurance excludes loss or damage caused by or resulting from, or
costs incurred from or of:
wear and tear or corrosion; and
inherent defects.
26. The policy does not define „corrosion‟ but the Concise Oxford English
Dictionary (eleventh edition, revised) states:
„ Corrosion n. the process of corroding or being corroded‟
„Corrode v. (with reference to metal or other hard material) destroy or be destroyed
slowly by chemical action. Gradually weaken or erode.‟
27. The FSP contends that its policy is written in plain language and is clear and
unambiguous. The policy clearly informs the Applicants that general exclusions
apply to all covers.
28. Its marine surveyor reported:
“Cause
The bolt that is the hinge for the retaining bracket that locks the lid of the strainer on
the starboard side raw water strainer has parted under tension allowing the seal to
fail on the lid gasket with salt water flooding the engine room.
It would appear that the bolt in question is most likely not 316 stainless steel and
appears to have sustained corrosion eventually causing it to fail. In our opinion this
corrosion has most likely occurred due to unknown grades of stainless steel being
used in construction of the strainer. This may have occurred at the supply source of
the material or at the time of manufacture of the strainer however where this occurred
is unlikely to be determined.”
29. The Applicants‟ metallurgist reported that:
Case No: 236136 Determination Page 5 of 9
the bolt was fractured inside the tube...When it was removed some
surface corrosion was evident;
the steel quality of the bolt was poor.
30. It is not disputed by the Applicants or the FSP that corrosion was evident or that
the inherent quality of the steel used in the manufacture of the bolt was
responsible for the damage.
31. Although the Applicants were not aware of the inherent defect of the bolt either
at the time of purchase of the vessel, or at inception of the policy, it remains a
fact that the bolt had corroded and the inferior metal used in its construction
was an inherent defect.
32. Therefore, the FSP contends that the general exclusions of „corrosion‟ and
„inherent defects‟ can be applied to the circumstances of the Applicants‟ claim.
Section 46 of the Insurance Contracts Act 1984 (the Act)
33. Section 46 of the Act provides:
“ that if a claim is made in respect of a loss that occurred in whole or in part as a result
of a defect or imperfection in a thing and the insured was not aware of the defect or a
reasonable person in the circumstances could not be expected to have been aware of
the defect or imperfection, the insurer may not rely on an exclusion clause that refers
to the condition of the thing before the contract was entered into. ”
34. The Applicants have sought relief from the policy exclusions by relying on
section 46 of the Act.
35. The FSP contends that there are two alternative reasons why section 46 of the
Act does not apply.
36. Firstly, the FSP refers to the decided case of Nelson v The Hollard Insurance
Company Pty Ltd [2010] NSWSC 199 (on appeal).
37. The Court held that section 46 of the Act does not apply to an exclusion of an
event which makes no reference to when the event occurs. That court has
determined that the application of section 46 has to take place in relation to the
wording of the policy and not the particular facts of the case.
38. Therefore, only those exclusions which refer to a condition existing before entry
into the contract are affected by section 46. The FSP also refers to Asteron Life
Limited v Zeiderman [2004] NSWCA 47.
39. The exclusion in the FSP‟s contract of insurance refers to „inherent defects‟
without reference to the inherent defects arising or existing prior to the contract
being entered into. Therefore, as the exclusion does not refer to a pre-
contractual condition, section 46 of the Act cannot be relied upon by the
Applicants.
40. Therefore, the FSP is entitled to rely on the exclusions contained within the
policy wording that excludes its liability.
Case No: 236136 Determination Page 6 of 9
41. The second alternative ground for section 46 not applying is that ‟corrosion‟ is
neither a defect nor an imperfection, but rather a process that is ongoing.
42. The Concise Oxford English Dictionary defines „corrosion‟ as:
“Defect n. a shortcoming, imperfection, or lack‟
Imperfection adj. Faulty or incomplete.”
43. What both of these definitions have in commo n is that they refer to a fixed state
of affairs or a final outcome, not a continuing process. It follows that the
„corrosion‟ exclusion, describing a process, falls outside of section 46 of the
Act.
44. The Applicants contend that the FSP‟s marine surveyor‟s opinion that corrosion
eventually caused the bolt to fail is manifestly incorrect. They submit that their
metallurgist stated that the bolt failed due to inter-granular attack.
45. The FSP refers to an extract from Perry‟s Chemical Engineers‟ Handbook by
Don W Green and James O Maloney 7 th ed., 1997, which states:
„ Intergranular corrosion (IGC), also known as intergranular attack (IGA), is a form of
corrosion where the boundaries of crystallites of the material are more susceptible to
corrosion than their insides, (Cf. Transgranular corrosion) ‟
46. Therefore, when the Applicants‟ metallurgist was referring to „inter -granular
attack‟ he was referring to what is also commonly known as „inter -granular
corrosion‟.
47. The Applicants have also stated that it would be grossly unfair for the FSP to
rely upon an obscure and unduly restrictive interpretation of the intended
meaning of section 46 of the Act, when it clearly exists for the purpose of
protecting insured‟s in the predicament the Applicants find themselves.
48. The FSP contends that it has relied upon the findings of the Supreme Court of
NSW in the Nelson (on appeal) and Asteron Life cases where the principle to
be applied by the Court has been the subject of detailed and thorough
submissions and arguments.
49. The FSP contends that based on all the available evidence, it submits it has
correctly applied the terms, conditions and exclusions of the policy to deny
indemnity to the Applicants for their claim.
50. Further, the FSP‟s final decision in this matter was made with full reg ard to
section 46 of the Act and the cited legal principles derived from case law.
51. The FSP relies on the following policy/contract provisions:
“General exclusions
Like most insurance policies, there are general exclusions that apply to all
covers.
You are not covered for any loss or damage caused by or resulting from, or the
costs incurred from or of:
Case No: 236136 Determination Page 7 of 9
...
wear and tear, mould, gradual deterioration, timber rot, delamination, vermin,
corrosion, electrolysis, osmosis or marine growth;
inherent defects, structural faults, faulty workmanship or faulty design;”
Issues
52. Whether the FSP is entitled to rely on the policy exclusions to deny indemnity to
the Applicants for their claim. The onus rests on the FSP to establish that, on
the balance of probabilities, the cause of the damage to the Applicants‟ vessel
was the result of an excluded event.
There has been an exchange of material which the parties rely on. Each party has
had access to the material on which the other party bases its case. As a
consequence, it is not necessary to go into all of this material in any great
detail.
Reasons for Decision
Application of Policy Exclusion
53. The FSP has relied upon two policy exclusions to deny indemnity to the
Applicants. Firstly, the damage to the ves sel was the result of an „inherent
defect‟ and secondly, „corrosion‟.
54. Where one, or both, causes of the loss fall within an exception or exclusion
clause in the contract, the insurer is not liable. Wayne Tank and Pump Co Ltd v
Employers Liability Assurance Corp Ltd (1973) 3 All ER 825.
Inherent Defect
55. The contract of insurance excludes loss or damage caused by or resulting from
an inherent defect.
The marine surveyor appointed by the FSP reported:
“ The bolt that is the hinge for the retaining bracket that locks the lid of the strainer on
the starboard side raw water strainer has parted under tension allowing the seal to
fail on the lid gasket with salt water flooding the engine room.
It would appear that the bolt in question is most likely not 316 stainless steel and
appears to have sustained corrosion eventually causing it to fail. In our opinion this
corrosion has most likely occurred due to unknown grades of stainless steel being
used in construction of the strainer. This may have occurred at the supply source of
the material or at the time of manufacture of the strainer however where this occurred
is unlikely to be determined.”
56. The Applicants appointed a metallurgist to investigate the cause of the bolt
failure. In a report dated 12 January 2011, he stated:
Case No: 236136 Determination Page 8 of 9
„Visual Inspection
The stainless steel strainer cover assembly Fig 1 had been held in position on
the left-hand side as viewed, by a 9.5mm (3/8 inch) diameter stainless steel
threaded bolt that ran through the tube on the hold-down frame. The bolt had
fractured inside the tube at the bottom end. When it was removed, some
surface corrosion was evident to the fracture adjacent to the fracture and also
some longitudinal grooving., Fig 2. None of this could have been seen while
the bolt was in position inside the tube. Fracture surface appearance was
heavily oxidized, Fig 3.
...
Cracks in the longitudinal section about 1mm behind the fracture were both
trans-granular – as occurs with stress corrosion – and intergranular – typical
of sensitization due to heating, see Fig. 5. Microstructure adjacent to the
fracture showed heavy intergranular attack and cracks, Fig. 6. Further away
from the fracture – beyond the weld HAZ, carbide grain boundary networks
were evident, Fig.7.
Grooves along the bolt, Figs. 2 and 4, were associated with heavy – dark
etching – bands of high impurity content, Fig. 8.
Conclusions
4. The bolt was a grade of non-magnetic stainless steel.
5. It had failed by intergranular attack in the heat-affected zone of a weld on
the bolt end. The weld thermal cycle had sensitised the steel to attack.
6. Steel quality of the bolt was poor with heavy segregation bands and also
grain boundary carbide networks throughout the microstructure.‟
57. Therefore, on the balance of probabilities, the bolt contained an inherent defect,
either through:
the bolt not being 316 stainless steel;
unknown grades of stainless steel being used in the construction of the
strainer;
the bolt was of a grade of non-magnetic stainless steel;
the bolt had failed by intergranular attack; or
the steel quality of the bolt was poor with heavy segregation bands and
also grain boundary carbide networks throughout the microstructure.
Insurance Contracts Act 1984
The Applicants have relied on section 46 of the Act to negate the effect of the policy
exclusions. They contend the fault in the bolt existed from the date of
manufacture of the sea water strainer.
In view of the imperfection/defect predating the commencement date of the contract
of insurance the Applicants contend that they can rely on section 46 of the Act
and the FSP cannot deny indemnity for their claim.
Case No: 236136 Determination Page 9 of 9
The policy exclusion relied upon by the FSP states:
“ You are not covered for any loss or damage caused by or resulting from, or the
costs incurred from or of:...”
There is no mention as to a time when the exclusion applies. The policy does
not state that the exclusion applies after the contract of insurance commenced.
The exclusion applies to an event that occurred at any time whether before or
after the commencement of the policy.
The decisions in the Nelson (on appeal) and Asteron cases have the effect of
determining when sections 46 and 47 of the Act apply. That is, section 46 does
not apply to an exclusion of an event which makes no reference to when an
event occurs. As stated above, the FSP‟s policy doe s not state when the
exclusion applies and consequently section 46 cannot provide the relief sought
by the Applicants from the effects of the FSP‟s policy exclusions.
Determination
58. Therefore, the Panel finds that the FSP is entitled to rely upon the „inher ent
defect‟ policy exclusion to deny liability for the Applicants‟ claim.
59. Although the Applicants were not aware of, and a reasonable person in the
circumstances could not be expected to be aware of, the defect or imperfection,
the Panel also finds that section 46 of the Act does not provide any relief to the
Applicants against the application of the policy exclusion.
60. Accordingly, the Panel determines the FSP is entitled to deny indemnity to the
Applicants for their claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.