Home / Financial Firm (Unknown - Insurer) / Determination 235877
Determination 235877
Storm water inundation claim denied for wear and tear and failure to maintain
Summary
The Applicants claimed for storm water inundation damage to their home and contents, which the FSP denied for wear and tear, design and maintenance reasons. AFCA found a covered storm and ordered the FSP to pay the claim, with no amount stated.
The FSP was aware of the property's floor and door design issues when it insured and repaired the property, so it waived reliance on the exclusions.
Issues
- Claim denial primary · upheld“The Panel considers the FSP has waived its right to rely on the relevant policy exclusions.”
Subjects and remedies
home or building damagenatural disasterpay claim
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Case No: 235877 Determination Page 1 of 8
Case number: 235877
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of claim
6 December 2011
Background
1. The Applicants held a Home Building and Contents Policy (the policy) with the
Financial Services Provider (FSP) covering a residential property.
2. On or about 4 September 2010 the Applicants‟ property was inundated with
water during severe weather events experienced in the region causing
extensive damage. The Applicants contacted the FSP and lodged a c laim
seeking indemnity under the policy for their loss.
3. The FSP denied the claim on the ground that the loss was as a result of wear
and tear and failure to maintain.
Summary of Applicants ’ Position
4. The Applicants own a 1/2acre block with a holiday weekender on it, which they
visit when time allows. The property was built in the 1960‟s and used as a
butcher shop until the Applicants‟ purchase in 2003 at which time it was used
solely as a residence.
5. The locale of the Applicants‟ property was subject to serio us storms. However,
the Applicants only became aware of the damage when a local informed them
of same.
6. The Applicants discovered that water had run through the building, causing
damage to the flooring (a timber floating floor) and damage to contents.
7. In the first instance the FSP accepted the claim but then reversed this decision
after a short time frame.
8. The Applicants note the property was previously flooded in 2007 and a claim
was lodged with the same FSP to repair the damage. The repairs included
laying the floor and replacing another door which the FSP now declares is not
up to standard.
Determination
Case No: 235877 Determination Page 2 of 8
9. The Applicants have enclosed email correspondence between them and the
FSP from the 2007 storm related damage. The Panel notes the following from
these emails:
The floorboards lifted and swelled.
The boards cracked open, the back door would not open and the front
door only opened enough to squeeze through.
The scope of works agreed upon by the parties was not satisfactorily
carried out. Further works were required to finish the items including the
re-finish of the floorboards which was below standard.
The front door was required to be repainted.
There was to be no paint left on the varnished door step.
10. The Applicants have enclosed the Contract Scope of Works from 2007 from
which the Panel notes:
The front and rear entry doors were to be removed and replaced.
Remove and replace floating floor to complete open plan area.
„Similar‟ to existing approx 38SQM (concrete slab)
11. The Applicants acknowledge and agree with the FSP‟s allegation that the
property was not watertight as required by the policy. This was because the
bottom of the door was at ground level which created an opening for water
entry and the timber flooring was exposed at the rear door.
12. In response, the Applicants note that the FSP actually performed the last works
to the rear door and is responsible for the exposed timber flooring at the rear
door.
13. The Applicants further submit that the floor quoted in the 2007 Scope of Works
was not in fact the floor that was f itted. This was despite the Applicants‟ verbal
objection at the time and the specific request that a floating floor be laid as
required by the Scope of Works.
14. The Applicants have spoken with experts but have had difficulty obtaining a
written report. However, the experts have indicated that had the Contract
Scope of Works been complied with at the time, the floorboards would not have
swelled and taken on water causing them to rise into peaks. Further, as the
skirting boards were nailed to the floorboards there was no expansion allowed
for in the event of water entering the building on the insured premise.
15. The Applicants deny the FSP‟s submission that they have not established a
storm (as defined by the policy) was the cause of the damage. The Applicants
have enclosed multiple articles regarding the storm occurrence.
16. The Applicants submit that the water entered not as a result of a storm created
opening but rather due to the poor workmanship previously carried out by the
FSP in 2007.
Case No: 235877 Determination Page 3 of 8
17. The Applicants seek payment for repairs to the damaged flooring and rear door
as well as replacement of contents damaged by the water inundation.
Summary of FSP’s Position
18. The FSP relies on the following policy terms and conditions:
“Storm
If your home or contents suffer loss or damage caused by
• a violent wind, cyclone or tornado
• thunderstorm or hail which may be accompanied by rain or snow, or
• a sudden, excessive run-off of water as a direct result of a storm in your local
area
we will under contents insurance
• replace or repair your damaged contents
we will under buildings insurance
• ebuild or repair that part of your home that was damaged
...
however under buildings insurance
• we will not cover loss or damage caused by storm to retaining walls, or when
water enters
through an opening that was not created by the storm.
What you are not covered for – general exclusions
We will NOT cover
- loss, damage, injury or death that occurs as a result of
...
• wear, tear, rust, corrosion, deterioration or erosion
...
Things that may put your claim or cover at risk
...
• do not maintain your home in good repair and condition. This means your
home must be
watertight, structurally sound, secure and well maintained
...
storm
is a violent wind, cyclone, tornado, thunderstorm or hail which may be accompanied by
rain or snow, or a sudden, excessive un-off of water as a direct result of a storm in
your local area. It does not include persistent rain by itself.”
Case No: 235877 Determination Page 4 of 8
19. The FSP relies on an assessment report, from which the Panel notes the
following:
The property is used as a weekender.
The point of water entry was the rear door.
The Applicants do not know what time the water entered the property as
they were not home.
The water came from the direction of the creek which runs at the front of
the property.
Freshwater entered the property.
The assessor was of the opinion that the water has run through the
property because of “poor and lack of drainage”. There is one drain pipe
to the dwelling which is not connected. Further the timber floor is exposed
at the rear door and the dwelling is sitting level.
Locals advised the assessor that the “canel” (sic) at the front of the
property did rise due to poor maintenance but did not rise above the
footpath.
20. The FSP relies on the hydrologist report, from which the Panel notes the
following:
The property is approximately 150m east of the Burnbank Creek.
A moderately large rainfall event was experienced in Landsborough on
Friday night and continued on through the early hours of Saturday with a
peak of 47.2mm recorded on Saturday morning.
The flooding in the Applicants‟ locale could be the result of either
Burnbank Creek overflow or local runoff as a result of heavy rainfall in the
local catchment and inadequate drainage infrastructure.
The hydrologist noted that catchment flows have traversed the area
behind the subject site and have been channelled through the yard
adjacent to the subject site‟s buildings back toward the Burnbank Creek.
Flows from the adjacent garage have also been channelled through this
area. Further, direct stormwater flows from the site buildings have not
been directed off site and may have pooled on site.
Annotated photographs are enclosed with the report showing catchment
flows from a site adjacent to the insured property and the pooling of
unmitigated downpipe run-off. The photograph of the downpipe indicates it
is not connected to a stormwater drainage system. The photographs
indicate the pooling would be to the side of the house which does not
contain either the front or rear door.
A review of data indicates that direct flooding from Burnbank Creek is
unlikely.
The hydrologist concludes that the inundation of the property was caused
by a combination of site runoff and catchment run-off.
Case No: 235877 Determination Page 5 of 8
21. The FSP relies on a building expert report from which the Panel notes the
following:
The FSP has informed the building expert that the Applicants disagreed
with the assessor and hydrologist that water ingress was due to
maintenance issues and insufficient drainage. The Panel notes that the
hydrologist provided no such opinion regarding maintenance and only
indicated the source of inundation. The photographs taken by the building
expert are annotated to indicate rotten timbers on the window, the
stormwater down pipe angled away from the building to a corrugated
sheet, rising timber flooring, the minimal difference between ground floor
level and the property‟s back door entry.
The building expert was of the opinion that the damage could have been
avoided if the insured property was constructed and maintained in
compliance with the Building Code of Australia, the Australian Standard
for residential slabs and footings and the CSIRO guide to home owners
on foundation maintenance and footing performance.
The building expert notes that the floor level of the residence is the same
height as the surrounding ground. There is no height difference as
required by the Building Code of Australia and Australian Standard
between the floor level and external surface height.
The site is not drained and to add to this the one down pipe on the
building discharges the rain water directly onto the ground adjacent to the
building.
The building expert concludes the residence was not constructed or
maintained in a manner to prevent storm water damage occurring.
22. The FSP submits that the Applicants ha ve not provided any evidence that a
storm, as defined by the policy, caused the damage or that the damage was the
result of the storm. The FSP notes that persistent rain by itself does not
constitute storm.
23. The FSP contends that the water did not enter the property through an opening
created by the storm. Further, that all three experts confirm the water entered
through design issues, maintenance issues and/or general wear and tear.
24. The FSP submits the policy excludes cover for loss or damage to buildings
caused when water enters a property through an opening that was not created
by the storm. A plain reading of this clause provides that there is no cover
where water has entered the property through a pre-existing opening and not
from storm damage.
25. The policy further excludes damage arising from wear and tear or deterioration
of the property. Further, the policy requires the Applicants to keep the property
watertight, structurally sound, secure and well maintained.
26. The FSP submits the Applicants failed to maintain the property because there
was no drainage at the property and the sole downpipe of the property did not
connect to a drainage system thereby resulting in pooling around the house.
Case No: 235877 Determination Page 6 of 8
Further the property was not watertight as required given that the bo ttom of the
door to the property was at ground level creating an opening for water entry
between the door and floor whereby the water could enter unimpeded. Further,
the timber floor was exposed at the rear door.
27. The FSP was informed by the Applicants that the downpipe used to discharge
into a rainwater tank which was stolen and not replaced.
28. The FSP further relies on the case of Wayne Tank and Pump Co Ltd v
Employers Liability Assurance Corporation Ltd [1974] QB 57 . This case stated
that if a loss has two or more proximate or effective causes and at least one
cause is excluded from cover the insurer is not liable.
29. The FSP contends that if the Panel accepts that the storm contributed to the
damage that the policy exclusion argued by the FSP would negate any liability
as the building issues and failure to maintain also contributed to the loss.
Issues
30. Whether the FSP has appropriately declined the Applicants‟ claim.
Reasons for Decision
31. There has been an exchange of material between each party, and the Panel is
satisfied each party has had an opportunity to reply to the issues raised.
32. The Panel has read each party‟s submissions and materials and will only refer
to the relevant submissions and materials raised.
33. First, the Panel does not consider the FSP‟s argument that there was no storm
as defined by the policy can be maintained in light of the e vidence. The
evidence includes the statement by the hydrologist that the “...low pressure
system brought with it high winds and heavy rainfall as it moved through
Victoria....The rainfall event began on 2 nd of September as severe storms
moved into Victoria ”. The Applicants have further produced multiple articles
regarding the storm event.
34. The Panel concludes that the storm event from which the water inundation and
resultant damage occurred included high winds and heavy rainfall. Accordingly,
the event meets the policy definition of storm.
35. The Panel further notes that the hydrologist and building experts‟ evidence
accepts that water inundation from the stormwater run-off, rather than riverine
flood water, entered the property and caused the damage. Accordingly, the
Applicants have established a prime facie claim for damage under the policy.
36. The Panel notes however that the policy is subject to exclusions and the FSP
has relied on these exclusions to cover to decline the claim.
Case No: 235877 Determination Page 7 of 8
37. The Applicants accept that the pr operty is not „watertight‟ as water has entered
through the opening at the bottom of the door which is at ground level and that
the timber flooring was exposed at the rear door.
38. However, the Applicants have argued and produced evidence that not only was
the FSP aware of this at the time of incepting the policy for the relevant period,
but also that it completed the works to the property including the rear door and
allowed the exposed timber flooring (despite alleged verbal complaints).
39. The Panel has read the previous scope of works and email correspondence
between the parties relating to the 2007 storm damage. The Panel further notes
this evidence has not been contested by the FSP.
40. The Panel therefore accepts that the FSP was not only aware of the property‟ s
contentious floor level, but also the exposed timber flooring. It is unclear when
the rainwater tank was stolen and if the FSP was aware of the uncontrolled
discharging water from the downpipe.
41. There is no information before the Panel regarding the largest contributing
factor to the inundation. The evidence from the hydrologist confirms that the
inundation was contributed to by both catchment run-off and site run-off.
Although there has been confirmation that there was a pooling affect caused by
the uncontrolled discharge of the downpipe, there has been no information
whether this would have joined with the flow of catchment and other site run-off
through the property.
42. This leaves the design issues and lack of drainage infrastructure to be
considered by the Panel and whether these issues constitute an exclusion of
cover under the policy.
43. The evidence and acknowledgement of the Applicants would appear to suggest
that the height of the floor and exposed floorboards did contribute to the
inundation. The Applicants have further added that had the floorboards been
constructed as a floating floor and the skirting board not nailed to the floor, then
the damage would not have occurred to the extent it did. The FSP has not
responded to this statement.
44. The Applicants have been critical of the FSP‟s reliance on design issues given
that the FSP performed the works noted as an issue by the builder; further, they
assert it was aware of the design issues due to a previous claim, which it
settled by repairing the property.
45. The question before the Panel then becomes has the FSP waived the right to
rely on the exclusions given it was aware of the design issues and performed
the work on the property which its building expert now suggests has contributed
to the damage.
46. The Panel considers that the FSP was aware of the particular design issues of
the property having had its agents attend to perform previous repairs at the site.
Further, the FSP has chosen to accept the risk presented by the property and
has been responsible for the state of the flooring and its unfinished nature.
Case No: 235877 Determination Page 8 of 8
47. The Panel also holds concerns that the FSP is attempting to rely on the building
not being maintained to the Building Code and Australian Standards, given that
the property was built well before the impleme ntation of the current Code and
Standards. The building itself was clearly built to different prevailing standards
and could not necessarily be maintained in accordance with newer standards.
In order to meet such standards large sections of the property wo uld need to be
rebuilt.
48. The hydrologist mentions „drainage infrastructure‟ as an issue, however it is
unclear whether the hydrologist refer to the site specifically or the general
drainage systems in the area. It is unclear to the Panel whether the relevant
authority has provided for appropriate drainage infrastructure, particularly the
comments about a poorly maintained channel off site.
49. The Panel considers the FSP has waived its right to rely on the relevant policy
exclusions. It was aware of the state of the property and chose to insure it
regardless. Further, the claimed building defects are only defects according to
the current code rather than the Codes/Standards under which it would have
been built. It seems somewhat improper to retrospectively apply the Code and
Standards to the building design and construction.
Determination
50. On the basis of the available information the Panel determines that the FSP
should attend to payment of the Applicants‟ claim for damage arising from the
storm event.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.