Home / Financial Firm (Unknown - Insurer) / Determination 232823
Determination 232823
Machinery breakdown claim for refrigerator coil denied under corrosion exclusion
Summary
A business owner claimed under the machinery breakdown section of a business policy after a refrigerator coil leaked. The FSP denied the claim as caused by corrosion, which is excluded. AFCA accepted the FSP's qualified expert report and found the FSP was entitled to deny liability.
The insurer bears the onus of proving an exclusion, and the corrosion exclusion applies to any corrosion however caused, which the qualified expert evidence established.
Issues
- Claim denial primary · not upheld
“The policy clearly excludes claims arising from corrosion, however caused, and unfortunately for the Applicant, the exclusion applies to defeat the claim.”
- Inadequate claim investigation secondary · not upheld
“in the absence of any other expert opinion, I accept that report.”
Subjects and remedies
small businessno remedy
Text of the determination
Case No: 232823 Determination Page 1 of 3
Case number: 232823
General Insurance - Small Business/Farm Insurance - Machinery breakdown -
FSP Decision - Denial of claim – Corrosion
6 July 2011
Background
1. This is a review of a Recommendation by the Service dated 17 May 2011.
2. On 22 December 2010 the Applicant lodged a claim under the machinery
breakdown section of his business insurance policy for repairs to a refrigerator.
The repairer found the coil with internal fins was leaking. Repairs included
replacement of the coil, vacuum and regasing the system.
3. The Financial Services Provider (FSP) denied liability for the claim on the
ground that the cause of the leak was due to corrosion and excluded from
cover provided by the policy.
Summary of Applicant’s Position
4. The Applicant submits:
The FSP’s assessor was not independent and is paid by the FSP.
The assessor reported “ the damage was caused by corrosion from wear &
tear” but is not supported by evidence.
The assessor cannot arrive at a conclusion based on a guess which is
wrong.
Without acid during normal use, normal use cannot cause the evaporator
coil to corrode.
The evaporator coil is inside a plastic box, fixed to the ceiling of the
refrigerator and cannot be touched. No maintenance is required. Hence it
does not fall within the wear and tear exclusion.
There is a fan under the coil which runs 24 hours a day. It spins the
leaking gas which is green, back to the coil making part of the coil look
like corrosion.
5. He considers his claim should therefore be paid.
6. The Applicant states that the refrigerator was used for holding milk only and
there was no acid present. He says it follows from this that his ordinary use of
Determination
Case No: 232823 Determination Page 2 of 3
the fridge could not have caused the coil to corrode and if the corrosion was not
caused by ordinary use of the fridge then he says the claim should be paid.
Summary of FSP’s Position
7. Engineering assessors were appointed to assess the loss and confirm the
cause for the problem.
8. The assessor confirmed that the problem was due to wear and tear and
operating conditions. They also advised that the leak was due to corrosion
which occurred possibly due to food acid which builds up in the cabinet.
9. The FSP submits that the loss is not covered and that the following policy terms
apply.
“ Specific exclusions applicable to this section
We will not pay for
…
3. wasting or wearing away or wearing out of any part of an insured item caused
by or naturally resulting from ordinary use of working, gradual deterioration
including erosion, rust, corrosion, boilers, scale or oxidation (due to normal
atmospheric conditions or otherwise). …”
Issues
10. Whether corrosion of the coil is excluded from cover provided by the policy.
Reasons for Decision
11. I have carefully perused the file. I have had particular regard and submissions
of the parties and I note the Applicant’s further submission under cover of his
email dated 30 May 2011.
12. The FSP is relying upon an exclusion in the policy in respect of “corrosion” and
it has the burden of establishing on the balance of probabilities that the
exclusion applies.
13. It is not in dispute that the fridge coil was leaking. The repairer’s invoice for a
internal fin in the fridge does not explain the cause of the leak.
14. The FSP appointed a qualified expert and I accept that the person appointed
was qualified to give an expert opinion. Prior to preparing his report, the
assessor discussed the issues with the repairer. Save for his personal opinion,
the Applicant has not provided any expert e vidence.
15. The FSP’s assessor expressed the clear view that the leak was caused by
corrosion and offered the view that this may have been caused from food acid
Case No: 232823 Determination Page 3 of 3
which builds up in the cabinet through normal use. It is this last comment which
has drawn attention from the Applicant. It should be emphasised that the
possible cause of corrosion given by the assessor was simply a suggested
explanation.
16. Whilst there is not a definitive view as to the cause of the corrosion, it seems
clear to me that the resultant damage was caused by a corrosion and in the
absence of any other expert opinion, I accept that report.
17. The policy clearly excludes claims arising from corrosion, however caused, and
unfortunately for the Applicant, the exclusion applies to defeat the claim.
Determination
18. In my opinion, the FSP was entitled to deny liability for the claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.