Text of the determination
Case No: 229864 Determination Page 1 of 9
Case number: 229864
General Insurance - Domestic Insurance - Home Building - FSP Decision -
Denial of claim – Leaking Pipe – Ground Movement – Proximate Cause
20 July 2011
Background
1. The Applicant holds a home building and contents insurance policy issued by
the Financial Services Provider (FSP). The policy was renewed on an annual
basis, including the period of 16 September 2009 to 16 September 2010.
2. In April 2010, the Applicant noticed cracks in the walls of the building, which
prompted him to engage a building services company (CBS) to report on the
nature and cause of the cracks. Following receipt of the report, the Applicant
lodged a claim against the policy for the rectification work to the property.
3. At claim lodgement, the FSP appointed an external loss adjuster and an
engineer (FMG) to provide reports on the cause of the damage. Upon receipt of
the experts ’ reports, the FSP denied liability on the basis that the cracks were
caused by foundation soil movement, which is specifically excluded from co ver
by the policy.
4. The Applicant seeks review of the FSP’s decision as he believes the cracking
has been brought about directly as a result of the escaping water from the main
water pipe.
Summary of Applicant ’ s Position
5. The FSP is required to indemnify him for the cost of repair and all other
associated fees that he had incurred in disputing the decision.
6. His engineer’s (LBS) report indicates that the distress to the residence is
directly attributed to the escape of liquid from the main water pipe, this has
resulted in an outward/upward heaving action of moisture in the sub floor soil,
causing outward rotation of the strip footings under the north and south walls.
7. He is seeking reversal of the FSP’s decision on the basis that the damage was
brought about directly as a result of the escaping water from the leaking pipe,
which he was unaware of for an undetermined period of time.
Determination
Case No: 229864 Determination Page 2 of 9
Summary of FSP ’s Position
8. It is not in dispute that the Applicant was clearly informed in writing of the
relevant policy provisions. Alternatively, the Applicant knew, or a reasonable
person in the circumstances could be expected to have known, of the relevant
policy provisions.
9. The Applicant bears the onus of establishing the damage was caused by a risk
insured against. However, the FSP does not accept the Applicant had
established this on the available evidence.
10. The FSP ’s experts ’ reports indicated the damage was not caused by the
escape of liquid, but it was due to differential foundation movements, which is
specifically excluded from cover by the policy.
11. The Applicant’s engineer did not carry out his own investigation. Instead he
utilised the data supplied by FMG.
12. The FSP relies on the following policy exclusions:
“ The insured event you are covered for
1. …
10 Bursting, leaking, discharging or overflowing of fixed apparatus, fixed tanks, or
pipes used to carry liquid of any kind.
…
General Exclusions
These General Exclusions apply to all sections of the policy.
In addition to these General Exclusions, sections of this policy may be subject to
specific exclusions.
This policy does not cover:
…
erosion, subsidence, landslide, settling, shrinkage, expansion, underpinning,
washing away or any other earth movement except when loss or damage is
caused by:
o earthquake
o storm or rainwater
o explosion or
o escape of liquid
and occurring within 72 hours after the event
…
gradual deterioration,…
settling, seepage, shrinkage or expansion in buildings, walls, roofs, floors,
ceilings, foundations, pavements, roads and the like
…
Case No: 229864 Determination Page 3 of 9
trees or tree roots, the felling or lopping of tree(s) by you or by any person acting
on your behalf or with your consent, or the removal of tree(s) or branch(es) from
the site ” .
Issue
13. Whether the FSP is entitled to deny liability for the claimed loss.
Reasons for Decision
14. I am satisfied there has been a full exchange of material between the parties
and that each party has had the opportunity to respond to the issues raised.
15. The onus is on the Applicant to establish, on the balance of probabilities, that
he suffered a loss caused by a risk insured against. Therefore, the Applicant
must establish the water leak has caused the cracks and the timeframe in
which they have occurred.
16. The Applicant conceded that there had been leaking for an undetermined
period of time and he did not know the date of loss. However, he submits he
noticed internal distress in January 2010 and cracks in the wall in March 2010.
In support of his position, the Applicant provided a report from a Building
Surveyor (LBS) which reads in part the following:
“ Inspection
…I i nspected the dwelling on November 23, 2010, 187 days after the FMG
inspection & report.
Movement in attached garage is not related to the movement in the house due to
the distance from the trees on the adjoining allotment, to the house. The trees
have no influence on the house movement. The attached garage is a separate
building with a totally different form of construction to that of the house. The
ground movement observed has a minor effect on the garage structure itself.
This is also evident in the very minor cracking in the east wall of the garage.
There is no west wall to the garage and the roof frame is supported by roof
beams built into the external wall of the house. There is no visual distress on the
west wall of the house. The garage will continue to experience long term
settlement of the east wall and slab due to the higher brick wall load.
The concrete pathway on the east side of the garage has no structural bearing
on the garage other than its ability to retain the moisture content in the
foundation under the garage slab. The movement observed in the garage
reflects the standard of construction and has no bearing on the house damage.
At the time of my inspection, the subfloor soil was visually inspected. It was
observed and determined that the „drying out‟ process had commenced. The
colour of the soil surface has changed from dark to grey to a white grey colour.
The presence of efflorescence salt deposits is clearly observable on the soil
surface. 5mm under the surface, the soil is still damp. In boreholes 1 & 2, the
deeper soil is quite damp with 31 to 28% moisture content.
Case No: 229864 Determination Page 4 of 9
The wetting period between the start of the leaking and the repair of the pressure
pipe on April 7, 2010 has caused the foundation material to swell from a dry state
to a saturated state. Since April 7, 2010 the drying out process has proceeded.
At this time of the FMG‟s inspection on May 20, 2010, 43 days after the repair,
minimal drying had occurred.
The deep soil material at 1.7m indicates the residual base moisture present in
the foundation with an average 29% +/- 1% moisture variation. The unrelated
boreholes 3 & 4 indicate a range of 30 to 35% moisture variation at a depth of
1.2m which reflects the vertical passage of the recent heavy rainfall through the
various sub soil zones…
The floor system has domed (upheave) with the result of inducing tension stress
on the frame and interior lining. The central region has experienced the most
severe stress with vertical downward cracking in the kitchen.
Other movement is the outward rotation of the side brick walls (north & south)
with the timber frame (top plate) under tension, opposing the outward rotation
from the strip footing system. Evidence of brick tie separation is apparent in the
front brick wall between the two NE windows.
…
The central heaving action of the house foundation has clearly lifted the floor
system, and caused outward rotation of the strip footing over the north & south
walls. Progressive collapse action within the timber framework has induced
differential torsion and twisting racking forces are at play on the frame. Rotation
of the downpipe from the inward racking forces at ceiling level has resulted in a
twisting 90 degree bend fitting. The horizontal Stormwater drain would have
opposed the torsion affect.
Opinions & Recommendations
1. The escape of liquid from the pipes has caused the earth heaving movement
underneath the house.
2. The heaving earth movement caused the damage to the internal walls that
were partly repaired by the owner.
3. Recent rainfall events have increased the soil moisture level in the house
surrounds and garden.
4. The strip footing system has experienced outward rotation from the soil
heave movement.
5. The side brick wall has now stabilized due to the matching moisture content
as identified in the FMG report.
6. Racking forces in the ceiling and roof frame has induced inward movement of
the east timber wall frame. The force increased the gap between the wall
junction at the house frame and garage brick wall.
7. The torsion movement resulting from the house frame & brick wall has
twisted and probably cracked the 90 degrees bend fitting in the downpipe.
8. The extent of damage caused to the house wall frame and lining is clearly
observable.
9. The house damage is caused by the escape of high pressure liquid from the
mains water pipe”
Case No: 229864 Determination Page 5 of 9
17. The FSP engaged an expert engineer (FMG) who investigated and wrote a
report on 21 June 2010. In summary, he wrote:
“In summary, there is currently insufficient evidence to conclude that the
previously leaking water pipe, or possibly leaking storm water/sewer drains, have
caused any significant damage to this house.
Testing of the storm water and sewer drains, including CCTV surveys, should be
carried out immediately to determine the current defects in these services, and
any defects causing water leakage should be repaired immediately.
The extent to which the defective hydraulic services have caused abnormal
moisture conditions in the foundation soils is currently unknown, and soil testing
is recommended to make an assessment of this.
If the leaking services have caused local abnormal moisture conditions in the
foundation soils, a period of time (at least 6 to 8 months) should be allowed for
the soils to dry out naturally.
An accurate levels monitoring survey would be helpful in assessing the
percentage contribution of the leaks to the building distress, however this would
be a relatively expensive exercise. An alternative would be to re-inspection the
property after say 8 months, and, if necessary, carry out additional soil moisture
con tent testing to confirm the soil has dried out.”
18. After arranging testing by a hydraulic services specialist and a geo-technical
investigation in October 2010, a further report was provided to the FSP by its
expert and dated 9 November 2010.
19. The report from FMG, read in part as follows:
“ Distress to house
…
The distress to the house has generally been caused by differential foundation
movements, caused by differential changes in the moisture contents of the highly
reactive clay soils at this site.
The pattern and locations of internal and external wall distress were typical of
minor differential foundation movements. In this case, the floor levels survey
indentified a relative settlement of the internal region of the house of
approximately 10 m m…. This pattern of movement commonly occurs for strip
and stump footing systems, and is caused by long term drying of the soils within
the sub-floor space. It was evident that re-blocking has previously been carried
out, indicating that this type of movement has occurred previously. If this re-
blocking had not been carried out, the magnitude of the relative settlement of the
central region of the house would have been expected to be significantly higher
than 10 mm.
In the writer‟s opinion, there is no evid ence that the leak in the water pipe has
caused, or contributed to, any damage to this house. This statement is made for
the following reasons:-
i. The level contour diagram does not indicate any „typical‟ foundation
movements in the vicinity of the leak.
ii. The level of distress to the house in the vicinity of the leak is not
significantly higher.
iii. The distress to the house did not appear to be recent.
Case No: 229864 Determination Page 6 of 9
iv. It was evident that previous repairs have been carried out, and that
previously repaired cracks have re-opened.
v. There is no significant difference in the level of distress between FMG‟s
inspection on 20.05.2010 and 27.10.2010.
vi. The soil testing did not identify higher soil moisture content at BH1/FP1,
located nearest to the water leak. In fact, the average soil moisture
content was lowest at this location.
Distress to garage
The level survey indicated that there is a relative fall of the garage towards the
SE. The distress to the garage is consistent with this movement. In the writer‟s
opinion, the main causes of this movement are as follows:-
i. Soil drying on the eastern side of the garage due to the group of trees in
the adjoining eastern property
ii. The „drought‟ conditions in Melbourne in recent years
iii. Seasonal changes in soil moisture contents, which are amplified by the
trees.
iv. The highly reactive soils at this site.
In the writer‟s opinion, the defect in the top of the PVC storm water drain has not
caused, or contributed to, the distress to the garage for the following reasons:-
i. The level contour diagram does not indicate heave has occurred in the
NW corner of the garage.
ii. Only the top of the PVC pipe was observed to be damaged. This pipe
previously collected the overflow from the rainwater tank. The amount of
water leakage from this pipe resulting from water overflowing from the
tank would be expected to be minimal, if any, especially considering the
„drought‟ conditions in Melbourne in recent years, and the fact that the
defect was observed in the top of the pipe.
iii. No relative heave was measured in the NE corner of the ho use (kitchen)”
20. FMG also reviewed the report from the Applicant’s expert and made the
following points:
“…The subject site is classified as Class H (high reactivity) in accordance with
AS2870 Residential Slabs and Footings. Highly reactive clays experience
significant volumetric changes with changes in moisture contents. Highly reactive
clays with high moisture contents experience swelling, known as heaving, and
highly reactive clays with relatively low moisture contents experience shrinking or
relative settlement. The subject site is understood to have experienced a leaking
water supply pipe located near the NW corner of the lounge external wall and
this was repaired on 7 April 2010.
In general, the subject site highly reactive clays are subject to changes in
moisture contents as a result of the following possible influences:
(a) Leaking services can cause wetting of the clays, thereby causing relative
heave
(b) Trees cause soil desiccation, thereby causing relative settlement of the
clays
Case No: 229864 Determination Page 7 of 9
(c) Natural ventilation within the sub floor space causes long term drying of
the clays, particularly in the central region of the residence.
(d) Perimeter strip footings, in particular can be subject to foundation
movement as a result of seasonal changes in moisture contents and/or
drought conditions which Melbourne has experience3d over the last 12
years and/or recent heavy rains.
With the above understanding, FMG makes the following comments regarding
the LBS report:
… the contour levels show relative settlement of the central region of the subject
residence as a result of (c) above, ie internal drying of the sub floor space has
continued to occur since repacking of stumps. FMG also observed previously
repaired cracks had re-opened which is consistent with this ongoing relative
settlement.
… the garage will continue to experience relative settlement of the east wall …
this is attributed to the nearby trees located on the east side of the garage.
FMG‟s spot floor level survey confirms relative floor settlement in the direction of
these trees.
…
We note that soil testing results taken at borehole 1(BH1), ie location near
proximity of leaking water pipe was identified to have the relative driest moisture
contents when compared to the remaining boreholes taken during the
geotechnical investigation. The floor levels survey does not show any local
heave in the area of leak which is typical observed after such an event. The
founding material of the strip footing at BH1 location was identified to be
adequate having an allowable bearing capacity of 200KPa, this compares to the
founding material at the south side of the residence (ie BH2) which had an
allowable bearing capacity of 140KPa. Clearly the leaking water has not affected
the soil properties in proximity to the leak. In some circumstances, excessive
water can cause saturation of the clays and consequential loss of bearing/ and or
relative settlement.
…
FMG (concluded) there is no evidence that the leak in the copper pipe has
caused, or contributed to any damage to this house for the following reasons:
The levels contour diagram does not indicate any „atypical‟ foundation
movements in the vicinity of the leak
The level of distress to the house in the vicinity of the leak is not
significantly higher
The distress to the house did not appear to be recent
It was evident that previous repairs have been carried out, and that
previously repaired cracks have re-opened.
… FMG (noted it) made a number of attempts to obtain the water bills regarding
this investigation at the subject residence. However, this has been unsuccessful.
Should these become available, FMG would be happy to review, although it is
unlikely that these bills will alter the outcomes of the investigation.”
Case No: 229864 Determination Page 8 of 9
21. There is no response by LBS or the Applicant to this report.
22. As said earlier in this Determination, it is established insurance law that an
insured has the onus of proof to establish that loss or damage is from an
insured event. Accordingly, the Applicant has the onus to prove the loss and
damage to his house and garage is as a result of the leaking pipes.
23. The Applicant relies on a report from LBS who is a civil engineer and building
surveyor. The FSP relies on a report from FMG, signed by a structural engineer
and another engineer. FMG have also engaged two other experts: one who
investigated the plumbing line services and who said that the pipe leak and
broken pipe did not contribute to the damage; and another who did a technical
site investigation and said the existing footings of the house did not meet
current standards and that on a highly reactive site with drying and wetting over
the footings are likely to cause distress in the house.
24. The latter expert also thought the trees on the boundary near the garage are of
a size to cause drying and shrinkage under the footing. FMG also thoug ht the
trees were one of the possible causes of damage to the garage.
25. However, the Applicant and LBS contend that the trees from the adjoining
property have not contributed to the cracking in either the garage or the main
dwelling. The Applicant states that “ a qualified horticulturalist has advised that all
three tree types on the adjoining property are of shallow rooted and that, considering
their current size and distance from the garage and house, their roots systems would
have no effect on the foundations of either” .
26. The Applicant has not provided a report from the horticulturalist and I am
therefore not inclined to give much weight to unsubstantiated hearsay evidence
when considering this matter.
27. In any event, aside from the trees, other reasons are posited for the damage to
the house, aside from the leaking pipes.
28. The two engineers from FMG and the geotechnical analysis say there are other
reasons for the damage to the house – reasons which are not insured against.
29. The expert in the plumbing line services also says the lines did not contribute to
the damage to the house.
30. In all the circumstances, and having carefully considered all the expert material,
the relevant parts of which I have set out in full in this determination, I find the
preponderance of evidence supports the FSP’s contention that the damage to
the house and garage was not caused by an insured event and so I am not
satisfied that the Applicant has discharged the onus he has to establish his loss
and damage is related to a defined event under the policy.
Case No: 229864 Determination Page 9 of 9
Determination
31. I determine the FSP is entitled to deny indemnity for the claimed loss.