Home / Financial Firm (Unknown - Insurer) / Determination 229864

Determination 229864

Wall cracking claim denied under foundation movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2011-07-20
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The Applicant claimed for house and garage cracking he attributed to a leaking water pipe, and the FSP denied it as foundation soil movement, which the policy excludes. AFCA found the Applicant had not proved the damage was caused by an insured event, so no payment was ordered.

The preponderance of expert evidence showed the damage was caused by uninsured differential foundation movement, and the Applicant bore the onus of proving an insured cause.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 229864 Determination Page 1 of 9 Case number: 229864 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim – Leaking Pipe – Ground Movement – Proximate Cause 20 July 2011 Background 1. The Applicant holds a home building and contents insurance policy issued by the Financial Services Provider (FSP). The policy was renewed on an annual basis, including the period of 16 September 2009 to 16 September 2010. 2. In April 2010, the Applicant noticed cracks in the walls of the building, which prompted him to engage a building services company (CBS) to report on the nature and cause of the cracks. Following receipt of the report, the Applicant lodged a claim against the policy for the rectification work to the property. 3. At claim lodgement, the FSP appointed an external loss adjuster and an engineer (FMG) to provide reports on the cause of the damage. Upon receipt of the experts ’ reports, the FSP denied liability on the basis that the cracks were caused by foundation soil movement, which is specifically excluded from co ver by the policy. 4. The Applicant seeks review of the FSP’s decision as he believes the cracking has been brought about directly as a result of the escaping water from the main water pipe. Summary of Applicant ’ s Position 5. The FSP is required to indemnify him for the cost of repair and all other associated fees that he had incurred in disputing the decision. 6. His engineer’s (LBS) report indicates that the distress to the residence is directly attributed to the escape of liquid from the main water pipe, this has resulted in an outward/upward heaving action of moisture in the sub floor soil, causing outward rotation of the strip footings under the north and south walls. 7. He is seeking reversal of the FSP’s decision on the basis that the damage was brought about directly as a result of the escaping water from the leaking pipe, which he was unaware of for an undetermined period of time. Determination Case No: 229864 Determination Page 2 of 9 Summary of FSP ’s Position 8. It is not in dispute that the Applicant was clearly informed in writing of the relevant policy provisions. Alternatively, the Applicant knew, or a reasonable person in the circumstances could be expected to have known, of the relevant policy provisions. 9. The Applicant bears the onus of establishing the damage was caused by a risk insured against. However, the FSP does not accept the Applicant had established this on the available evidence. 10. The FSP ’s experts ’ reports indicated the damage was not caused by the escape of liquid, but it was due to differential foundation movements, which is specifically excluded from cover by the policy. 11. The Applicant’s engineer did not carry out his own investigation. Instead he utilised the data supplied by FMG. 12. The FSP relies on the following policy exclusions: “ The insured event you are covered for 1. … 10 Bursting, leaking, discharging or overflowing of fixed apparatus, fixed tanks, or pipes used to carry liquid of any kind. … General Exclusions These General Exclusions apply to all sections of the policy. In addition to these General Exclusions, sections of this policy may be subject to specific exclusions. This policy does not cover:  …  erosion, subsidence, landslide, settling, shrinkage, expansion, underpinning, washing away or any other earth movement except when loss or damage is caused by: o earthquake o storm or rainwater o explosion or o escape of liquid and occurring within 72 hours after the event …  gradual deterioration,…  settling, seepage, shrinkage or expansion in buildings, walls, roofs, floors, ceilings, foundations, pavements, roads and the like  … Case No: 229864 Determination Page 3 of 9  trees or tree roots, the felling or lopping of tree(s) by you or by any person acting on your behalf or with your consent, or the removal of tree(s) or branch(es) from the site ” . Issue 13. Whether the FSP is entitled to deny liability for the claimed loss. Reasons for Decision 14. I am satisfied there has been a full exchange of material between the parties and that each party has had the opportunity to respond to the issues raised. 15. The onus is on the Applicant to establish, on the balance of probabilities, that he suffered a loss caused by a risk insured against. Therefore, the Applicant must establish the water leak has caused the cracks and the timeframe in which they have occurred. 16. The Applicant conceded that there had been leaking for an undetermined period of time and he did not know the date of loss. However, he submits he noticed internal distress in January 2010 and cracks in the wall in March 2010. In support of his position, the Applicant provided a report from a Building Surveyor (LBS) which reads in part the following: “ Inspection …I i nspected the dwelling on November 23, 2010, 187 days after the FMG inspection & report. Movement in attached garage is not related to the movement in the house due to the distance from the trees on the adjoining allotment, to the house. The trees have no influence on the house movement. The attached garage is a separate building with a totally different form of construction to that of the house. The ground movement observed has a minor effect on the garage structure itself. This is also evident in the very minor cracking in the east wall of the garage. There is no west wall to the garage and the roof frame is supported by roof beams built into the external wall of the house. There is no visual distress on the west wall of the house. The garage will continue to experience long term settlement of the east wall and slab due to the higher brick wall load. The concrete pathway on the east side of the garage has no structural bearing on the garage other than its ability to retain the moisture content in the foundation under the garage slab. The movement observed in the garage reflects the standard of construction and has no bearing on the house damage. At the time of my inspection, the subfloor soil was visually inspected. It was observed and determined that the „drying out‟ process had commenced. The colour of the soil surface has changed from dark to grey to a white grey colour. The presence of efflorescence salt deposits is clearly observable on the soil surface. 5mm under the surface, the soil is still damp. In boreholes 1 & 2, the deeper soil is quite damp with 31 to 28% moisture content. Case No: 229864 Determination Page 4 of 9 The wetting period between the start of the leaking and the repair of the pressure pipe on April 7, 2010 has caused the foundation material to swell from a dry state to a saturated state. Since April 7, 2010 the drying out process has proceeded. At this time of the FMG‟s inspection on May 20, 2010, 43 days after the repair, minimal drying had occurred. The deep soil material at 1.7m indicates the residual base moisture present in the foundation with an average 29% +/- 1% moisture variation. The unrelated boreholes 3 & 4 indicate a range of 30 to 35% moisture variation at a depth of 1.2m which reflects the vertical passage of the recent heavy rainfall through the various sub soil zones… The floor system has domed (upheave) with the result of inducing tension stress on the frame and interior lining. The central region has experienced the most severe stress with vertical downward cracking in the kitchen. Other movement is the outward rotation of the side brick walls (north & south) with the timber frame (top plate) under tension, opposing the outward rotation from the strip footing system. Evidence of brick tie separation is apparent in the front brick wall between the two NE windows. … The central heaving action of the house foundation has clearly lifted the floor system, and caused outward rotation of the strip footing over the north & south walls. Progressive collapse action within the timber framework has induced differential torsion and twisting racking forces are at play on the frame. Rotation of the downpipe from the inward racking forces at ceiling level has resulted in a twisting 90 degree bend fitting. The horizontal Stormwater drain would have opposed the torsion affect. Opinions & Recommendations 1. The escape of liquid from the pipes has caused the earth heaving movement underneath the house. 2. The heaving earth movement caused the damage to the internal walls that were partly repaired by the owner. 3. Recent rainfall events have increased the soil moisture level in the house surrounds and garden. 4. The strip footing system has experienced outward rotation from the soil heave movement. 5. The side brick wall has now stabilized due to the matching moisture content as identified in the FMG report. 6. Racking forces in the ceiling and roof frame has induced inward movement of the east timber wall frame. The force increased the gap between the wall junction at the house frame and garage brick wall. 7. The torsion movement resulting from the house frame & brick wall has twisted and probably cracked the 90 degrees bend fitting in the downpipe. 8. The extent of damage caused to the house wall frame and lining is clearly observable. 9. The house damage is caused by the escape of high pressure liquid from the mains water pipe” Case No: 229864 Determination Page 5 of 9 17. The FSP engaged an expert engineer (FMG) who investigated and wrote a report on 21 June 2010. In summary, he wrote: “In summary, there is currently insufficient evidence to conclude that the previously leaking water pipe, or possibly leaking storm water/sewer drains, have caused any significant damage to this house. Testing of the storm water and sewer drains, including CCTV surveys, should be carried out immediately to determine the current defects in these services, and any defects causing water leakage should be repaired immediately. The extent to which the defective hydraulic services have caused abnormal moisture conditions in the foundation soils is currently unknown, and soil testing is recommended to make an assessment of this. If the leaking services have caused local abnormal moisture conditions in the foundation soils, a period of time (at least 6 to 8 months) should be allowed for the soils to dry out naturally. An accurate levels monitoring survey would be helpful in assessing the percentage contribution of the leaks to the building distress, however this would be a relatively expensive exercise. An alternative would be to re-inspection the property after say 8 months, and, if necessary, carry out additional soil moisture con tent testing to confirm the soil has dried out.” 18. After arranging testing by a hydraulic services specialist and a geo-technical investigation in October 2010, a further report was provided to the FSP by its expert and dated 9 November 2010. 19. The report from FMG, read in part as follows: “ Distress to house … The distress to the house has generally been caused by differential foundation movements, caused by differential changes in the moisture contents of the highly reactive clay soils at this site. The pattern and locations of internal and external wall distress were typical of minor differential foundation movements. In this case, the floor levels survey indentified a relative settlement of the internal region of the house of approximately 10 m m…. This pattern of movement commonly occurs for strip and stump footing systems, and is caused by long term drying of the soils within the sub-floor space. It was evident that re-blocking has previously been carried out, indicating that this type of movement has occurred previously. If this re- blocking had not been carried out, the magnitude of the relative settlement of the central region of the house would have been expected to be significantly higher than 10 mm. In the writer‟s opinion, there is no evid ence that the leak in the water pipe has caused, or contributed to, any damage to this house. This statement is made for the following reasons:- i. The level contour diagram does not indicate any „typical‟ foundation movements in the vicinity of the leak. ii. The level of distress to the house in the vicinity of the leak is not significantly higher. iii. The distress to the house did not appear to be recent. Case No: 229864 Determination Page 6 of 9 iv. It was evident that previous repairs have been carried out, and that previously repaired cracks have re-opened. v. There is no significant difference in the level of distress between FMG‟s inspection on 20.05.2010 and 27.10.2010. vi. The soil testing did not identify higher soil moisture content at BH1/FP1, located nearest to the water leak. In fact, the average soil moisture content was lowest at this location. Distress to garage The level survey indicated that there is a relative fall of the garage towards the SE. The distress to the garage is consistent with this movement. In the writer‟s opinion, the main causes of this movement are as follows:- i. Soil drying on the eastern side of the garage due to the group of trees in the adjoining eastern property ii. The „drought‟ conditions in Melbourne in recent years iii. Seasonal changes in soil moisture contents, which are amplified by the trees. iv. The highly reactive soils at this site. In the writer‟s opinion, the defect in the top of the PVC storm water drain has not caused, or contributed to, the distress to the garage for the following reasons:- i. The level contour diagram does not indicate heave has occurred in the NW corner of the garage. ii. Only the top of the PVC pipe was observed to be damaged. This pipe previously collected the overflow from the rainwater tank. The amount of water leakage from this pipe resulting from water overflowing from the tank would be expected to be minimal, if any, especially considering the „drought‟ conditions in Melbourne in recent years, and the fact that the defect was observed in the top of the pipe. iii. No relative heave was measured in the NE corner of the ho use (kitchen)” 20. FMG also reviewed the report from the Applicant’s expert and made the following points: “…The subject site is classified as Class H (high reactivity) in accordance with AS2870 Residential Slabs and Footings. Highly reactive clays experience significant volumetric changes with changes in moisture contents. Highly reactive clays with high moisture contents experience swelling, known as heaving, and highly reactive clays with relatively low moisture contents experience shrinking or relative settlement. The subject site is understood to have experienced a leaking water supply pipe located near the NW corner of the lounge external wall and this was repaired on 7 April 2010. In general, the subject site highly reactive clays are subject to changes in moisture contents as a result of the following possible influences: (a) Leaking services can cause wetting of the clays, thereby causing relative heave (b) Trees cause soil desiccation, thereby causing relative settlement of the clays Case No: 229864 Determination Page 7 of 9 (c) Natural ventilation within the sub floor space causes long term drying of the clays, particularly in the central region of the residence. (d) Perimeter strip footings, in particular can be subject to foundation movement as a result of seasonal changes in moisture contents and/or drought conditions which Melbourne has experience3d over the last 12 years and/or recent heavy rains. With the above understanding, FMG makes the following comments regarding the LBS report: … the contour levels show relative settlement of the central region of the subject residence as a result of (c) above, ie internal drying of the sub floor space has continued to occur since repacking of stumps. FMG also observed previously repaired cracks had re-opened which is consistent with this ongoing relative settlement. … the garage will continue to experience relative settlement of the east wall … this is attributed to the nearby trees located on the east side of the garage. FMG‟s spot floor level survey confirms relative floor settlement in the direction of these trees. … We note that soil testing results taken at borehole 1(BH1), ie location near proximity of leaking water pipe was identified to have the relative driest moisture contents when compared to the remaining boreholes taken during the geotechnical investigation. The floor levels survey does not show any local heave in the area of leak which is typical observed after such an event. The founding material of the strip footing at BH1 location was identified to be adequate having an allowable bearing capacity of 200KPa, this compares to the founding material at the south side of the residence (ie BH2) which had an allowable bearing capacity of 140KPa. Clearly the leaking water has not affected the soil properties in proximity to the leak. In some circumstances, excessive water can cause saturation of the clays and consequential loss of bearing/ and or relative settlement. … FMG (concluded) there is no evidence that the leak in the copper pipe has caused, or contributed to any damage to this house for the following reasons:  The levels contour diagram does not indicate any „atypical‟ foundation movements in the vicinity of the leak  The level of distress to the house in the vicinity of the leak is not significantly higher  The distress to the house did not appear to be recent  It was evident that previous repairs have been carried out, and that previously repaired cracks have re-opened. … FMG (noted it) made a number of attempts to obtain the water bills regarding this investigation at the subject residence. However, this has been unsuccessful. Should these become available, FMG would be happy to review, although it is unlikely that these bills will alter the outcomes of the investigation.” Case No: 229864 Determination Page 8 of 9 21. There is no response by LBS or the Applicant to this report. 22. As said earlier in this Determination, it is established insurance law that an insured has the onus of proof to establish that loss or damage is from an insured event. Accordingly, the Applicant has the onus to prove the loss and damage to his house and garage is as a result of the leaking pipes. 23. The Applicant relies on a report from LBS who is a civil engineer and building surveyor. The FSP relies on a report from FMG, signed by a structural engineer and another engineer. FMG have also engaged two other experts: one who investigated the plumbing line services and who said that the pipe leak and broken pipe did not contribute to the damage; and another who did a technical site investigation and said the existing footings of the house did not meet current standards and that on a highly reactive site with drying and wetting over the footings are likely to cause distress in the house. 24. The latter expert also thought the trees on the boundary near the garage are of a size to cause drying and shrinkage under the footing. FMG also thoug ht the trees were one of the possible causes of damage to the garage. 25. However, the Applicant and LBS contend that the trees from the adjoining property have not contributed to the cracking in either the garage or the main dwelling. The Applicant states that “ a qualified horticulturalist has advised that all three tree types on the adjoining property are of shallow rooted and that, considering their current size and distance from the garage and house, their roots systems would have no effect on the foundations of either” . 26. The Applicant has not provided a report from the horticulturalist and I am therefore not inclined to give much weight to unsubstantiated hearsay evidence when considering this matter. 27. In any event, aside from the trees, other reasons are posited for the damage to the house, aside from the leaking pipes. 28. The two engineers from FMG and the geotechnical analysis say there are other reasons for the damage to the house – reasons which are not insured against. 29. The expert in the plumbing line services also says the lines did not contribute to the damage to the house. 30. In all the circumstances, and having carefully considered all the expert material, the relevant parts of which I have set out in full in this determination, I find the preponderance of evidence supports the FSP’s contention that the damage to the house and garage was not caused by an insured event and so I am not satisfied that the Applicant has discharged the onus he has to establish his loss and damage is related to a defined event under the policy. Case No: 229864 Determination Page 9 of 9 Determination 31. I determine the FSP is entitled to deny indemnity for the claimed loss.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.