Home / Financial Firm (Unknown - Insurer) / Determination 229834
Determination 229834
Claim denial - bushfire heat damage to roof, gutters, windows and doors
Summary
The policyholder claimed bushfire heat damage to the roof, gutters, windows and doors after the 2009 Victorian bushfires. AFCA found the roof and guttering not damaged and ordered the FSP to pay 25% of the window and door quote, without interest.
Expert evidence supported some heat damage to the timber, but the property's pre-existing condition and unaffected vegetation made a partial settlement fair.
Subjects and remedies
home or building damagenatural disasterpay claim
Text of the determination
Case No: 229834 Determination Page 1 of 6
Case number: 229834
General Insurance - Domestic Insurance - Home Building - Service - Service
quality
20 April 2011
Background
1. The Applicant held a home building and contents policy with the Financial
Services Provider (FSP).
2. The Applicant’s property suffered damage following the Victorian Bushfires of
February 2009. The claim was assessed and the majority of the damage was
agreed upon and settled.
3. However, a dispute developed as to whether the roof, gutters, wooden windows
and doors were damaged by the heat during the fires. The FSP appointed an
engineer to inspect the property and reported the items were not damaged.
4. The FSP’s internal disputes resolution department reviewed the claim at the
request of the Applicant. It maintained the items were not damaged during the
event.
Summary of Applicant’s Position
5. He is mainly concerned with the wooden window frames and doors and is
willing to forgo the claim for the guttering and roof if those items are settled by
the FSP.
6. He provides a report from a timber expert, who reports the window frames and
doors have been affected by the heat from the bushfires.
7. The guttering was professionally installed in 2008. The FSP’s experts have
failed to mention there were two 40 metre Pine trees approximately 20 metres
from the eastern side of the home that burned intensively for three days. This
and debris and water caused the guttering to bow.
8. The FSP also fails to appreciate the timber in the property was recoated in
January 2009 and he provides evidence from the supplier of the materials that
this was the case.
9. He provides an estimate of $31,064 for the rectification of the window frames
and doors.
Determination
Case No: 229834 Determination Page 2 of 6
Summary of FSP’s Position
10. It has appointed assessors and an engineer, who report there was no damage
to the roof, gutters or wooden windows and doors at the property.
11. It is noted the area around the home was clear of fuel and therefore there was
minimal damage to the home itself. It has also been noted the heat around the
home was not sufficient to damage vegetation in the area or damage glass
window panes.
12. The property was also run down and in the process of being renovated at the
time of the loss.
13. With respect to the Applicant’s expert timber report, the FSP notes it was
conducted one and half years after the event, while its engineer inspected the
property within two weeks of the event. The report also notes the areas would
need to be sanded back to determine if there was weakening of the timber.
14. It has been very generous in its settlement of the other elements of the claim.
15. While it has agreed to the Financial Ombudsman Service (FOS) determining
the dispute now, it notes the dispute was originally lodged under the old Terms
of Reference and it could be excluded due to the time taken by the Applicant to
lodge. The Applicant has also signed a release discharging all claims; however,
it does not seek to rely on this in refusing the elements in dispute, nor FOS’
jurisdiction.
16. The FSP relies on the following policy provisions:
“ Insured events we will pay
…
4. Fire or smoke
(Applicable whether you have building and/or contents cover)
We will pay for loss or damage caused by fire or smoke. We will not pay for
damage:
a. which arises gradually out of repeated exposure to fire or smoke;
b. to any property as a result of its undergoing a process necessarily involving the
application of heat; or
c. to any property as a result of scorching and/or melting.
…
Parts A and B
When we will not pay a claim under your policy
1. This policy does not cover loss, liability, injury or damage:
…
f. Wear and tear
arising out of depreciation, gradual deterioration, wear and tear;
Case No: 229834 Determination Page 3 of 6
g. Inherent defects
caused directly or indirectly through inherent defects, faulty design, structural
defects or poo r workmanship;”
Issues
17. Whether the roof, guttering, windows and doors were damaged by an insured
event.
18. Whether the FSP is entitled to refuse indemnity under the terms and conditions
of the policy.
Reasons for Decision
19. There has been an exchange of information between the parties and the Panel
is satisfied each party has an opportunity to address the issues raised.
20. As advised to the parties, due to the nature of the dispute, FOS has considered
it appropriate to expedite this dispute directly to determination in accordance
with the Operational Guidelines to the FOS Terms of Reference.
21. The parties have provided a large body of evidence, much of which relates to
issues not currently in dispute. The Panel will only consider the matters
specifically in dispute, which include the roof, gutters, windows and doors.
Roof and Gutters
22. The Applicant submits the guttering which was installed in 2008 has bowed and
the roof has also suffered damage from extreme exposure to the heat from the
bushfires.
23. The FSP argues the guttering was poorly installed, the roof is aged and there is
no evidence of heat damage to either part of the property. The FSP provides a
building consultant’s report, dated 19 February 2009, which includes the
following information :
Box gutters looked to have been installed four to six months before the loss.
The guttering has not been installed in a tradesman like manner. Excessive areas
of silicone were noted, which might suggest leaking was present after the gutters
were installed.
On the west side of the property a tree the same height as the roof, located
approximately five metres away, which has not been affected by heat.
Timber beams in the floor area appeared to be rotted, which would indicate a
leaking issue has been present for a period of at least 12 months.
It appears the ground floor ceiling had recently been polished, although the work
was not of a good quality and patches are visible.
Case No: 229834 Determination Page 4 of 6
There is no evidence of heat damage to the guttering or roof.
24. The FS P also provides an engineer’s report, dated 19 June 2009, which
includes the following information :
The property was inspected on 23 February 2009.
The property is approximately 30 years old and the roof is advanced in its
serviceable life.
The guttering and flashing work that had been conducted before the fire was
done in an un-tradesman like manner.
A coating has been applied to the flashing, covering rust in some areas.
Generally the roof is in sound condition and leaks are unlikely. Brick facades also
shelter the roof somewhat.
Vegetation around the home shows no signs of damage from the heat, making
damage to the home from heat highly unlikely.
One window on the south side of the property is damaged, though this is thought
to have existed prior to the fire. No other window panes were damaged.
There is no evidence of damage to the roof or guttering as the result of the
bushfire.
25. The Applicant has not provided any specific evidence to support his submission
the roof and guttering was damaged by the fire.
26. The Panel has reviewed the photographs provided by the engineer and accepts
the guttering and flashing work on the roof has not been conducted in a
tradesman like manner. The Panel also finds there is no evidence in the
photographs to support the Appl icant’s submission the roof and guttering was
damaged during the bushfires.
27. Based on the evidence presented, the Panel is not satisfied the Applicant has
established the roof and guttering was damaged during the bushfires.
Windows and Doors
28. The Applicant submits the wooden window frames and doors have been
damaged by the extreme heat from the bushfires. He provides a report from a
timber expert, dated 07 July 2010, which includes the following information:
The property was inspected on 09 June 2010.
The wooden parts of the property have not been burnt, but are severely affected
by the heat and smoke.
The Applicant has advised the wood will not take polish or stain following the fire.
There was a large pine tree which burned within 20 metres of the home and due
to its size it would have burned close to the home. The fact a green Pine tree
burned is also testament to the extreme heat during the bushfires. This would
have added considerable radiant heat to the home.
Case No: 229834 Determination Page 5 of 6
The heat melted plastic spring covers and blackened the springs.
The window sills show a distinct bubbling effect, probably as the result of
chemicals being driven out due to the heat from the fire. The effects of heat on
timber are a very complex area and it is not known to what depth the timber has
sealed as a result of the fire.
The heat has more than likely affected the structural integrity of the timber,
although it is not possible to say to what depth from a visual inspection.
It is suggested some arrangement for the recovering of the surface should be
made, with the costs of sanding, scraping and recoating included.
The expert has also included information in relation to the properties of Western
Red Cedar timber.
29. The FSP’s Engineer’s report of 19 June 2009, included the following
information in relation to the wooden elements of the home:
The heat was not sufficient to crack a large glazed window.
The Applicant advised the house was in a somewhat rundown condition when it
was purchased in 2008 and he was in the process of renovating the home at the
time of the fire. The Applicant advised the timber frames were weathered and
had been let go by the previous owner.
A frame on the southern side had not been recoated at the time of the loss, yet
the Applicant is seeking to have it covered under the claim.
30. The FSP argues its engineer should be preferred to the Applicant’s expert
because the engineer attended within two weeks of the loss while the timber
expert’s inspection took place one and half years after the event.
31. In considering the evidence, the Panel notes the timber expert has provided an
extensive list of his qualifications and experience. Based on the evidence
provided, it would appear the timber expert is highly qualified. The Panel is also
persuaded by his report, that the heat from the fire has had at least some effect
on the wooden elements of the property, noting the evidence of the plastic
melting around the springs would indicate the property was subjected to heat.
32. However, at the same time, the Panel accepts the property was in a rundown
state at the time of the loss. The Panel also notes the vegetation around the
property does not appear to have been greatly affected by the heat from the
fires, although it accepts the area of the home in the location of the large burnt
pine tree was likely subject to more intense heat.
33. In considering the evidence as a whole, the Panel believes a fair and
r easonable outcome would be for the FSP to pay 25% of the Applicant’s quote.
It makes this decision, having regard for the fact there is expert evidence the
heat has likely damaged the wood, with evidence of the spring covers melting
while having regard for the fact not all the wood was in good condition and the
vegetation around the property does not appear to have been affected,
indicating it is unlikely the entire home was subjected to extreme heat.
Case No: 229834 Determination Page 6 of 6
Determination
34. On the basis of the available information, the Panel determines the FSP should
settle $7,766 (25% of $31,064) for the windows and doors of the home. In the
context of this determination, it would not be appropriate to award interest on
this payment.
35. The Panel determines the FSP may refuse indemnity for the roof and guttering.