Home / Financial Firm (Unknown - Insurer) / Determination 222997

Determination 222997

Denial of balcony waterproof membrane replacement cost after storm

FirmFinancial Firm (Unknown - Insurer)
Decided2011-04-29
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The insured claimed balcony water damage after a March 2010 storm, and the FSP denied the cost of replacing the waterproof membrane but accepted internal damage. AFCA upheld the membrane denial but found hail-damaged tiles and grout covered and ordered them assessed and indemnified.

The membrane failed or deteriorated independently of the insured storm event, so the policy does not cover its replacement, but hail damage to tiles and grout is covered.

Issues

Subjects and remedies

home or building damagenatural disasterreassess claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 222997 Determination Page 1 of 5 Case number: 222997 General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim-Exclusion/Condition 13 April 2011 Background 1. The Applicant holds a defined events home building and contents insurance policy with the Financial Services Provider (FSP). The building was insured for $371,000 and contents were insured for $50,000, subject to a policy excess of $100. 2. A claim was lodged on the policy for storm damage on 6 March 2010. Upon receipt of the claim the FSP appointed a builder to report on the cause of damage. 3. The FSP ’s builder reported that the waterproof membrane to the balcony has failed, allowing rainwater to enter the property. 4. As the Applicant was unaware of the defect in the balcony’s waterproofing capabilities, the FSP accepted liability for the internal damage. However, it rejected liability for the cost of rectifying the defective waterproof membrane. 5. The Applicant disagreed with the FSP and she is seeking the cost of repair to the balcony, including the cost to replace the waterproof membrane. Summary of Applicant ’s Position 6. The Applicant considers the proximate cause was due to storm/rainwater seeping through the tiles and grouts. The waterproof membrane is only a secondary measure. 7. Initially, the FSP denied the claim on the basis the damage was due to maintenance, wear and tear. However, at a later stage it changed its reasoning and denied the claim on the basis the damage was due to a defective waterproof membrane. 8. The photos clearly show hail indentations on the tiles and grout. 9. She has been living at the property for five years, and during her occupancy she has not experienced any water damage, until the storm in March 2010. Determination Case No: 222997 Determination Page 2 of 5 10. If there is a defect in the waterproof membrane then there would have been signs of water damage from the beginning and not five years later. 11. The FSP should agree to repair the damaged grouts. However, in order for the leak to be properly repaired, a new waterproof membrane would have to be installed. Summary of FSP’s Position 12. The Applicant has failed to provide sufficient evidence to establish the balcony was damaged by an insured event. As such, the FSP believes that it is not required to cover this aspect of the Applicant’s claim. 13. The FSP’s builder’s report advised that the cause of the balcony damage was due to the failure of the waterproof membrane. 14. The FSP’s builder was able to point out the flaws in the Applicant’s plumber’s report and he has concluded that the damage occurred as a result of a defective membrane. 15. The FSP relies on the following policy provisions: “ What you are covered for Insured Events 1 to 12 When covered under this policy, your home and contents are insured for loss or damage at the insured address by any of the 12 insured events, if they happen in the period of insurance. Storm and Flood Some key points We cover Damage caused by rain, wind hail, storm (eg. Your roof is torn off during storm) and damage caused by flood from rivers, streets and canals. … What is not covered under any part of your policy We do not cover loss or damage (continued): … Failing to establish an insured incident Loss or Damage without you being able to reasonably establish an insured incident took place at a certain time and place. … Wear, tear, rust and mould Loss or damage caused by wear, tear, rust, fading, gradual deterioration, mould, rising damp, mildew, action of light, atmospheric or climatic conditions, corrosion or rot Unless this is covered under: Insured event 1 (storm and flood) Case No: 222997 Determination Page 3 of 5 Insured event 2 (burst pipes, leaks and overflows) We will not: – Fix a fault that existed before the loss or damage occurred.” Issues 16. Whether the loss is covered by the policy. Reasons for Decision 17. I am satisfied that a full exchange of information has taken place between each party and that each party has had the opportunity to address any issues raised. 18. In order to succeed in this matter, the Applicant must demonstrate that the leak in the balcony was created by an event covered by the policy. 19. The Applicant provided photos in support that the grout and tiles on the balcony were damaged by hail. She also submits that the FSP has agreed to rectify the damaged grout. I have reviewed the material and photographs and I am of the view the tiles and grout were damaged by the storm and hailstones. Accordingly, the FSP should accept liability for the damaged grout and/or tiles. 20. The other issue in dispute is whether the FSP is entitled to deny liability for the waterproof membrane. 21. The FSP arranged to engage a plumber to look at the balcony on 3 June 2010 and he reported: “RJL attended the above property on 3 r d June 2010 to inspect and report on water entry via balcony.  Provide water discharge to floor waste drain on balcony (only).  Water appears to discharge to kerb and channel with no foreseeable blockage.  Water test tiles on balcony.  Water pools approximately 1m from discharge grate and leaks through tiles and membrane within 15-20 minutes  Photo attached.” 22. F ollowing the FSP’s denial of the Applicant’s claim for the waterproof membrane, the Applicant engaged WS Tiling Services to provide a report on the cause of the damage. The report, dated 20 July 2010, provides in part the following: “All work seems to be carried out in all appropriate manner and all regulations followed. It seems that the balcony has been designed and built to allow for standard and normal storm rainfall flowing along the tiled area down the waste grate. From my discussions with [the Applicant] and my observations, all care had been taken to the finest details from the caulking to the internal corners, Case No: 222997 Determination Page 4 of 5 through to the water proofing (membrane) applied to the floor prior to screed and then again to the screed before tiling preceded. It seems that since the outrageous storm that was experienced in Melbourne through the month of March, the amount of water this balcony had to cope with was beyond its capacity. With golf ball size hail, from the report of the storm, it seemed to have damaged a section of the grout. This may have occurred in a number of ways, and one that seems obvious to me could have been the hail would have been piled on to the balcony and therefore possibly freezing and blocking the drainage, therefore allowing the water to pond and overflow beyond the water proofing, creating its own channel of drain underneath the membrane, weakening the screed and grout, and from then on, it will continually allow the water to seep through. The water then continues through the grout and finds a way out through the floor and permanently creating a constant water channel whenever it rains. It is known with water, once it creates a path, it will continually use this path until it is removed and re- run elsewhere”. 23. Upon receipt of the Applicant’s p lumber’s report the FSP’s builder responded in part as follows: “It is impossible for your insured’s plumber to state all care has been taken to the installation of the waterproof membrane and the screed, the existing floor tiles and or ceiling under would have to be removed to verify this. We agree that the finished floor is in good condition, including the sealed internal corners and cannot fault any of the work that we can see. The balcony seems to have been built with enough fall to the floor drain waste, however as in our plumbers supplied report the water is ponding approximately 1m out from the floor discharge waste. If the golf ball sized hail has damaged the grout, which is fair and reasonable to assume, however your insured or your insured’s brother did not point this damage out to us whilst on site at our original attendance and we did not notice any damage to the grout. It still doesn’t deter from the fact that there is an underlying issue that is causing the water to enter the property, even if the golf ball size hail did freeze and cause the drain to block and the water built up above the line of the skirting tiles, there should still be a water proof membrane that turns up against the wall and substrate, if this membrane is fixed to the wall properly and there are no reason as to why water has entered the pooling or staining in the timber floor, therefore we should be able to rule out that water has built up to the height of the balcony door sill and or above the height of the skirting tiles, flown under the door sill, 150mm up the wall, if this waterproof membrane is installed correctly. With reference to the below paragraph in your insured’s plumber’s supplied report. The water would have made its way through the tiles and beyond the water proofing, creating its own channel of drain underneath the membrane, weakening the screed and grout, and from then on, it will continually allow the water to seep through the floor and permanently creating a constant water channel whenever it rains. Your insured’s plumber has stated that the water is penetrating further than the water proof membrane, this backs up our statement that the waterproof membrane has a defect or some other underlying issue that is causing the water to enter the property. Case No: 222997 Determination Page 5 of 5 As per our original builder’s report it is our professional opinion that the waterproof membrane to the balcony has failed and is now allowing water to enter the property, there are no maintenance related iss ues with your insured’s property and it is in excellent condition” 24. On the basis of the evidence presented, I am not persuaded by the Applicant’s expert report. I prefer the FSP’s expert’s explanations which are more rational and persuasive. Also, it is not clear to me exactly what is the expertise of WS Tiling Services. 25. The purpose of the waterproof membrane is to prevent rainwater from penetrating into the material that sits beneath it. If rainwater can still penetrate despite a membrane being in place, it implies that the membrane material was either defective or improperly installed. 26. Another likely cause of the damage is that the membrane may have simply deteriorated over time which, in my view, is also a reasonable proposition given that the balcony floor is exposed to the elements on a daily basis. 27. There was nothing wrong with the drainage from the balcony as agreed by both experts, so the only way the water could have got to the room below was if the membrane permitted it. 28. In this instance, the Applicant has not persuasively demonstrated that the storm and/or rainwater or some other event covered by the policy had caused the failure of the waterproof membrane. Determination 29. Accordingly, I determine that the FSP is entitled to deny indemnity for the cost of rectifying the waterproof membrane. However, I also determine it cannot deny indemnity to the cost of rectifying the tiles and grouting on the balcony. The Applicant has already made it good so the FSP’s expert may not have noticed the hail damage. If hail damage remains, it should be assessed and the Applicant indemnified under the policy.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.