The applicants claimed under business property insurance for storm damage to their restaurant roof, which the FSP denied on the basis of structural defects and pre-existing damage. AFCA determined the loss did not arise from an insured event, so the FSP could deny the claim.

The applicants did not establish that the storm loss occurred as an insured event, as pre-existing defects and damage were directly responsible for the water ingress.

Issues

Subjects and remedies

small businessno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Case No: 218905 Determination Page 1 of 5 Case number: 218905 General Insurance - Small Business Insurance - Storm Damage - Pre-existing Defect - FSP Decision - Denial of claim 22 February 2011 Background 1. The Applicants held business property insurance with the Financial Services Provider (FSP) from 22 October 2003 for their restaurant. The policy provided cover for $335,300, being for individually for building ($260,600), contents ($71,700) and stock ($3,000). 2. On 1 February 2010, the Applicants lodged a claim for storm damage caused to the roof of their property. An expert report was obtained to allege that the damage was caused as a result of a “torrential storm” . 3. The FSP appointed its own expert, who alleged that the damage was due to structural defects in the construction of the roof and pre-existing damage. The FSP denied the claim. 4. The Applicants reject the FSP’s position and seek cover for their loss, estimated at $10,472. Summary of Applicant’s Positi on 5. The Applicants say that their restaurant was damaged as a result of the heavy storm, which affected the roof of the property and caused water to come in through the ceiling. 6. They are reliant on an expert report that suggests the ingress of water occurred as a result of the separation of the expansion joints in the roof, caused by the heavy winds and rain. Summary of FSP’s Position 7. The FSP says that the roof was of defective construction, and relies upon the alleged concession from the male Applicant that it had leaked in the past. Determination Case No: 218905 Determination Page 2 of 5 8. Given that the construction was defective, the loss did not occur as a result of an insured event, and therefore the policy does not respond. 9. The FSP relies on the following provisions in support of its position: Pages 24-27 of the Product Disclosure Statement (PDS) “ Defined Events ... 8. Storm and/or Tempest, Water and Other Liquid ... (a) Rainwater Rainwater – Water in the form of rain falling from the sky on to the... building... (b) Run-off Run-off – Rainwater that has accumulated directly on and flowed across normally dry ground... (d) Storm and/or Tempest Storm and/or Tempest – a violent atmospheric disturbance accompanied by high wind, rain, snow or hail, but does not mean persistent bad weather, heavy rain or persistent rain by itself... Exclusions Applicable to Defined Event 8 1. We will not be liable for destruction or damage caused by: h. Water entering the Premises as a result of: i. structural defects; ii. faulty design; iii. faulty workmanship; or iv. lack of maintenance by You. ” Issues 10. Whether the Applicant’s loss was caused by an insured event. If so; 11. Whether the FSP is entitled to avoid cover based on exclusions in the policy. Reasons for Decision 12. As advised to the parties, FOS has considered it appropriate to expedite the dispute in accordance with the Operational Guidelines to the FOS Terms of Reference. This is because of the amount of the claim and the issues to be considered. This dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination. Case No: 218905 Determination Page 3 of 5 13. It is not in dispute that the loss was caused by the storm activity associated with a tropical cyclone, only as to whether the condition of the roof was sufficient to preclude attributing the loss to an insured event. 14. The policy provides cover for storm damage, although conditions apply to exclude cover for structural defects, faulty design, workmanship or a lack of maintenance. 15. The FSP does not accept the evidence of the Applicants’ expert, that the loss occurred simply as a result of the heavy wind and rain conditions causing a separation of the expansion joints in the roof, leaking water into the building. 16. It is instead reliant upon its own expert report, which suggests that there were two styles of roofing used, and an absence of flashings between the roof planes. There was evidence of attempts to unsuccessfully seal the leak with polycarbonate roof sheets and silicon sealant. The over tightening of roof screws had broken the bond in several areas, leaving several sheets of roof “flapping at the sheet ends”. 17. The Applicants do not deny the use of polycarbonate sheets and claim that this was undertaken at the suggestion of the FSP to protect the roof from further damage, as it would commit no one to look at the damage over the weekend. This is not disputed by the FSP. 18. The FSP’s expert said the male Applicant informed him that the home had been damaged three times in the previous seven years, although the exact cause of the alleged damage, its location and relevance to this claim was not explored. Whilst the Applicants did not dispute the allegation, I cannot lend any weight to it as evidence, as the significance of this concession was never explained. 19. The key issues will therefore be to determine if the absence of flashing was critical to the loss sustained by the Applicants , and/or if there were any other contributing factors. 20. I accept that the absence of flashing (to secure the roof against water penetration) should be considered a “structural defect” , despite the fact that the Applicants ’ expert raised no issue with the construction of the roof, nor did the report compiled prior to the purchase of the property. 21. It might have been preferable for the FSP to have better explained why the structure was defective, but I accept that proper water management on the roof requires flashings between the joins to avoid the type of problem incurred. 22. Whilst flashing should have been installed to ensure that the roof was properly protected, it is incumbent on the FSP to establish to what extent the absence of it was responsible the subsequent loss. 23. The Applicant’s expert suggested that the damage was: “ ... caused by the entry of large amounts of water breaking through the structural parts of the upper roof. This event took place due to intense volumes of water Case No: 218905 Determination Page 4 of 5 being released... with the combination of high winds made it impossible for the building to cope with this type of pressure.” 24. The claim notes provided by the FSP reveal that its expert suggested during a telephone call that: “... there is a possibility that strong winds could have lifted the roof sheet allowing water to enter as described by the [Applicants’]...” 25. Whilst the above explanations suggest that the storm and/or strong winds and rain associated with it caused the subsequent damage to the roof, this evidence needs to be considered in the context of the alleged structural defect and the prior work done by the Applicants. 26. I acknowledge that the Applicants provided a pre -purchase report that identified that no significant issues were present with the roof at the time of purchase. One area that was rectified was the repair and replacement of screw heads. This was attended to, but some replacement screws were apparently over tightened, as suggested by the FSP’s expert . This resulted in the stripping of the screws from the metal batten in some places on the roof. Some sheets were left “flapping” and this w as one of the causes of the water ingress. 27. Whilst I accept that the storm conditions likely caused the lifting of the roof and subsequent ingress of water, as suggested by the Applicant’s expert, the evidence suggests that this was due to the existing damage (broken screws) and the structural defect (absence of flashing). 28. The Applicants have supplied a further report from their roofing expert with an email dated 28 January 2011. However, that report does not assist the Applicants as it attributes the damage to the absence of flashing, between the main restaurant roof and its kitchen roof. 29. The burden of establishing that a claim occurred as a result of an insured event rests with the Applicants. They have provided a report which describes how the water has entered through the roof of the property (which I accept), however it is duly explained by the FSP’s expert that the water ingress was due to the absent flashing and broken screws. 30. The Applicants have not accounted for this, nor has their expert suggested an alternate cause for the loss or provided an explanation to debunk the opinion of the FSP’s expert . It is likely that the roof did lift, but this appears to have been a result of it not being secured properly, or being satisfactorily water proofed with the installation of flashing. 31. In consideration of this, I accept that the Applicants have not established that the loss occurred as a result of an insured event, as the roof was not in good enough condition prior to the event, and that the problems apparent were directly responsible for the subsequent loss. Case No: 218905 Determination Page 5 of 5 Determination 32. I determine that the FSP is entitled to deny the Applicants’ claim as the loss did not arise as a result of an insured event.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.