Home / Financial Firm (Unknown - Insurer) / Determination 213033
Determination 213033
Lift controller and lift motor damage claim denied under expendable items, controlling device and consequential loss exclusions
Summary
The owner of serviced apartments claimed under a residential strata machinery policy for a lift controller and motor failure, which the FSP denied under expendable item, controlling device and consequential loss exclusions. AFCA found the FSP had not proved the exclusions applied and that the motor damage was a direct result of the covered failure, so the FSP must indemnify both items, with labour to be added.
The insurer bears the onus of proving an exclusion applies, and the controller was not shown to be expendable while the motor damage was a direct result of the covered machinery failure.
Issues
- Claim denial primary · upheld
“The Panel determines that the FSP is liable to indemnify the applicant in relation to the damage to the microprocessor/controller unit and the damage to the lift motor.”
- Product terms interpretation secondary · upheld
“a reasonable person would understand the provision to mean that protective and controlling devices which are expendable are excluded; the unit is not an expendable item.”
Subjects and remedies
pay claim
Text of the determination
213033 Determination 1 of 5
DETERMINATION
Case number: 213033
Residential Strata – policy interpretation
SUMMARY OF FACTS
1. The applicant is the owner and operator of serviced apartments. He held a
Residential Strata Insurance Plan (the Plan) with the Financial Services
Provider (FSP) which was current at the date of loss.
2. The applicant lodged a claim on the policy in relation to the breakdown of a lift
at the premises of the serviced apartments.
3. The FSP investigated the claim and determined that the lift controller/processor
unit was damaged and required replacement and the motor was badly
damaged and needed to be rewound.
4. The FSP subsequently denied the claim on the basis that the lift
controller/processor unit and the lift motor are excluded from cover under the
Plan.
5. The applicant disputes the FSP's decision and maintains that the claim is
covered by the terms of the policy.
ISSUE IN DISPUTE
6. Whether the FSP‟s denial of the applicant‟s claim is in accordance with the
terms and conditions of the policy.
RELEVANT POLICY PROVISIONS
“ Policy 1 – Insured property
…
We insure You up to the Sum Insured shown for Policy 1 in the Schedule, against
ACCIDENTAL LOSS or DAMAGE to Your Insured Property which occurs during the Period
of Insurance.
…
Special benefits
…
5 Electric motors
We will pay for the cost of repairing or replacing an electric motor forming part of Your
Insured Property which has been burnt out by electric current.
…
We will not pay for:
…
b motors with an output in excess of five (5) kilowatts;
…
Exclusions – what we do not insure
1 We will not pay for loss or damage
…
e caused by overwinding, mechanical breakdown or derangement, electrical
breakdown or derangement, or failure caused by electric current.
213033 Determination 2 of 5
However We will pay of the loss or damage is due to:
i fusion of electric motors as covered under Special Benefit 5 ;
ii lightning;
iii power surge when such Event is confirmed by the supply authority;
or
iv if fire damage results.
…
Policy 7 – Machinery breakdown
…
Exclusions – what we do not insure
…
2 Damage to:
…
f expendable items, including electrical and electronic glass bulbs, tubes, lamps, x-
ray tubes, electrical contacts, fuses, heating elements, commutators, slip rings,
conducting brushes, thermal expansion (TX) valves, thermostats, protective and
controlling devices, over-loads, chains, belts, ropes, tyres, pressure switches,
bearings, valves, valve plates, filters and dryers;
…
3 Consequential loss of any kind other than that which is specifically stated.”
REASONS FOR DECISION
7. The Panel is satisfied that a full exchange of information has taken place
between the parties and that each party has had the opportunity to address any
issues raised.
8. Whilst the Panel has reviewed and considered all the material provided by the
parties, it will only discuss the matters of direct relevance to the issues in
dispute and its final decision.
The FSP‟s Submission
9. The FSP‟s position is that the damage was caused by an electrical breakdown
of the lift controller. The FSP submits that an electrical breakdown is excluded
from cover under Policy 1 of the Plan, except in limited circumstances which do
not apply in this case.
10. Furthermore, the FSP submits that the lift controller is specifically excluded
from cover under Policy 7 of the Plan, on the basis that it is a controlling device.
11. In relation to the damaged motor, the FSP submits that it is not covered by
Policy 1 as that policy only covers fusion of motors with an output up to 5
kilowatts and the motor in question has an output of 17 kilowatts.
12. In the FSP‟s opinion, the damage to the motor is also not covered by Policy 7.
The FSP submits that it was the lift contro ller which malfunctioned and the
damage to the motor was a consequential loss, which is excluded from cover
under Policy 7.
The Applicant‟s Submission
13. The applicant disputes the FSP's interpretation of the damaged lift
microprocessor/controller unit as an “expendable” item.
213033 Determination 3 of 5
14. He submits that the lift manufacturer/installer does not consider the
microprocessor/controller unit to be an expendable item and has provided a
report in which he states that the unit is a core component of the lift. He further
state s that the microprocessor/controller unit is not a “protective and controlling
device” but is the primary electronic component which manages the operation
of the lift.
Consideration of each party’s submission
15. This Determination will discuss the issues re lating to applicant‟s claim in two
parts. Firstly, the issues relating to replacement and installation of the
microprocessor/controller unit (the unit) at a cost of $49,068. Secondly, the
issues relating to repair and rewind of the lift motor at a cost of $13,057 plus
labour.
Microprocessor/controller unit
16. The applicant submits that the unit is not an “expendable” item and it therefore
does not come within the policy exclusion which the FSP relies on. The
applicant notes that there is no definition of „expendable‟ in the policy
documents. Accordingly, the applicant relies on the Oxford Dictionary definition
of „expendable‟ which is:
“of relatively little significance, and therefore able to be abandoned or destroyed”
“(of an object) designed to be used only once and then abandoned or destroyed”
17. The applicant submits that the unit which was damaged is a major core
component, which is integral to the operation of the lift. It is the entire lift
management system which determines the operation of the lift. In the
applicant‟s view, the unit is certainly not „an expendable‟ item, as defined in the
Oxford Dictionary. He submits that this view is further supported by the high
cost of the unit and the fact that a unit of this type is generally expected to
service a lift for its typical life span of more than 25 years.
18. The applicant has provided a report from the director of the original
manufacturer and installer of the lift. Relevantly, the report states:
“.. [the unit] is an integral component o f the lift itself, not an item which would or
should be considered in any way shape or form to be a general maintenance
item nor an item of the likes detailed within [the insurer‟s] Exclusion 2f
„expendable items‟ as describe [sic] above. The microprocesso r/controller unit is
not a „protective and controlling device” it is the primary electronic component
which manages the operation of the lift mechanism, not some ancillary fuse/relay
type protective device which would typically be referred to as expendable.
...
Clearly considering the cost of this integral component to an overall lift
installation, the unit would not have a classification of „expendable item.”
19. The FSP maintains its position that the unit is a controlling device and therefore
comes within the exclusion it relies on. It is not clear from the FSP's
submissions whether it is denying the claim based solely on its view that the
unit is a controlling device, or if its position is that the unit is both a controlling
device and an expendable item.
20. The Panel notes that the relevant policy provision excludes cover for
“expendable items including…. protective and controlling devices.” In the
213033 Determination 4 of 5
Panel‟s opinio n, a reasonable person would understand the provision to mean
that protective and controlling devices which are expendable are excluded from
cover. There may well be controlling devices which are expendable and others
which are not, and therefore the exclusion cannot reasonably be relied on to
exclude cover for all protective and controlling devices. In any event, in the
applicant‟s expert‟s opinion, the unit is not a “protective and controlling device”.
21. The FSP has not provided any evidence to support its view that the unit is a
controlling device and/or an expendable item. Interestingly, the FSP has not
responded directly to the report from the applicant‟s expert, nor has it
responded to the applicant submissions regarding the general nature of
expendable items as compared to the unit in question.
22. In the absence of any evidence to the contrary, the Panel is persuaded by the
expert opinion provided by the director of the lift manufacturer/installer who
states that the unit is not an expendable item and furthermore is not a
„protective and controlling device‟.
23. The Panel is also persuaded by the Oxford dictionary definition of the
„expendable‟ provided by the applicant. That definition indicates that
expendable items are those which are of relatively little significance and are
typically designed to be used only once and then abandoned. That does not
describe a $49,000 unit which is generally expected to operate successfully for
more than 25 years as the core operating component of the lift.
24. As the FSP is relying on an exclusion in the policy, the onus is on the FSP to
establish on the balance of probabilities that the claim falls within the exclusion.
The Panel is not satisfied that the FSP has established its onus regarding this
aspect of the claim.
Lift motor
25. The Panel notes that Policy 1 does not cover mechanical or electrical
breakdown or failure caused by electric current, except for fusion of motors with
an output of 5 kilowatts or less. The motor in question had an output of 17
kilowatts and therefore, the Panel is satisfied that there is no cover under Policy
1 for the damage to the motor.
26. Policy 7 provides cover for machinery breakdown, provided the insured item is
in the ordinary course of working at the time the damage occurred.
27. The FSP initia lly argued that the lift was not in the “ordinary course of working”
at the time the damage to the motor occurred. That position was based on
information which the FSP alleged was provided to its investigator by the
property manager of the insured premises. The property manager subsequently
provided a Statutory Declaration in which she denies making such statements.
28. In the FSP's Notice of Response it states that it is prepared to leave this matter
the lift being „in ordinary working order‟ in abeyance and t herefore the Panel will
not consider it any further.
29. The FSP has declined to cover the lift motor on the basis of the policy exclusion
relating to consequential loss. The FSP submits that it was the lift controller
which malfunctioned and in turn damaged the lift motor. Therefore, the damage
213033 Determination 5 of 5
to the lift motor is a consequential loss which is excluded from cover under the
policy.
30. The Panel does not agree with the FSP's position in that regard. In the Panel‟s
opinion the damage to the motor is a direct result of the failure of
microprocessor/controller unit and is part of the overall damage to the lift which
is covered by the terms of the machinery breakdown policy. That the damage to
the motor resulted after the failure of the processor does not in itself sufficiently
separate it from the event to consider it as a consequential loss, rather it should
properly be considered a direct result of the event.
CONCLUSION
31. The Panel determines that the FSP is liable to indemnify the applicant in
relation to the damage to the microprocessor/controller unit and the damage to
the lift motor.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.