Home / Financial Firm (Unknown - Insurer) / Determination 213033

Determination 213033

Lift controller and lift motor damage claim denied under expendable items, controlling device and consequential loss exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2010-11-29
ProductGeneral Insurance · Strata
OutcomeFor the complainant
Amount awarded$62,125
Non-financial loss—
Amount claimed$62,125
SourceAFCA PDF

Summary

The owner of serviced apartments claimed under a residential strata machinery policy for a lift controller and motor failure, which the FSP denied under expendable item, controlling device and consequential loss exclusions. AFCA found the FSP had not proved the exclusions applied and that the motor damage was a direct result of the covered failure, so the FSP must indemnify both items, with labour to be added.

The insurer bears the onus of proving an exclusion applies, and the controller was not shown to be expendable while the motor damage was a direct result of the covered machinery failure.

Issues

Subjects and remedies

pay claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

213033 Determination 1 of 5 DETERMINATION Case number: 213033 Residential Strata – policy interpretation SUMMARY OF FACTS 1. The applicant is the owner and operator of serviced apartments. He held a Residential Strata Insurance Plan (the Plan) with the Financial Services Provider (FSP) which was current at the date of loss. 2. The applicant lodged a claim on the policy in relation to the breakdown of a lift at the premises of the serviced apartments. 3. The FSP investigated the claim and determined that the lift controller/processor unit was damaged and required replacement and the motor was badly damaged and needed to be rewound. 4. The FSP subsequently denied the claim on the basis that the lift controller/processor unit and the lift motor are excluded from cover under the Plan. 5. The applicant disputes the FSP's decision and maintains that the claim is covered by the terms of the policy. ISSUE IN DISPUTE 6. Whether the FSP‟s denial of the applicant‟s claim is in accordance with the terms and conditions of the policy. RELEVANT POLICY PROVISIONS “ Policy 1 – Insured property … We insure You up to the Sum Insured shown for Policy 1 in the Schedule, against ACCIDENTAL LOSS or DAMAGE to Your Insured Property which occurs during the Period of Insurance. … Special benefits … 5 Electric motors We will pay for the cost of repairing or replacing an electric motor forming part of Your Insured Property which has been burnt out by electric current. … We will not pay for: … b motors with an output in excess of five (5) kilowatts; … Exclusions – what we do not insure 1 We will not pay for loss or damage … e caused by overwinding, mechanical breakdown or derangement, electrical breakdown or derangement, or failure caused by electric current. 213033 Determination 2 of 5 However We will pay of the loss or damage is due to: i fusion of electric motors as covered under Special Benefit 5 ; ii lightning; iii power surge when such Event is confirmed by the supply authority; or iv if fire damage results. … Policy 7 – Machinery breakdown … Exclusions – what we do not insure … 2 Damage to: … f expendable items, including electrical and electronic glass bulbs, tubes, lamps, x- ray tubes, electrical contacts, fuses, heating elements, commutators, slip rings, conducting brushes, thermal expansion (TX) valves, thermostats, protective and controlling devices, over-loads, chains, belts, ropes, tyres, pressure switches, bearings, valves, valve plates, filters and dryers; … 3 Consequential loss of any kind other than that which is specifically stated.” REASONS FOR DECISION 7. The Panel is satisfied that a full exchange of information has taken place between the parties and that each party has had the opportunity to address any issues raised. 8. Whilst the Panel has reviewed and considered all the material provided by the parties, it will only discuss the matters of direct relevance to the issues in dispute and its final decision. The FSP‟s Submission 9. The FSP‟s position is that the damage was caused by an electrical breakdown of the lift controller. The FSP submits that an electrical breakdown is excluded from cover under Policy 1 of the Plan, except in limited circumstances which do not apply in this case. 10. Furthermore, the FSP submits that the lift controller is specifically excluded from cover under Policy 7 of the Plan, on the basis that it is a controlling device. 11. In relation to the damaged motor, the FSP submits that it is not covered by Policy 1 as that policy only covers fusion of motors with an output up to 5 kilowatts and the motor in question has an output of 17 kilowatts. 12. In the FSP‟s opinion, the damage to the motor is also not covered by Policy 7. The FSP submits that it was the lift contro ller which malfunctioned and the damage to the motor was a consequential loss, which is excluded from cover under Policy 7. The Applicant‟s Submission 13. The applicant disputes the FSP's interpretation of the damaged lift microprocessor/controller unit as an “expendable” item. 213033 Determination 3 of 5 14. He submits that the lift manufacturer/installer does not consider the microprocessor/controller unit to be an expendable item and has provided a report in which he states that the unit is a core component of the lift. He further state s that the microprocessor/controller unit is not a “protective and controlling device” but is the primary electronic component which manages the operation of the lift. Consideration of each party’s submission 15. This Determination will discuss the issues re lating to applicant‟s claim in two parts. Firstly, the issues relating to replacement and installation of the microprocessor/controller unit (the unit) at a cost of $49,068. Secondly, the issues relating to repair and rewind of the lift motor at a cost of $13,057 plus labour. Microprocessor/controller unit 16. The applicant submits that the unit is not an “expendable” item and it therefore does not come within the policy exclusion which the FSP relies on. The applicant notes that there is no definition of „expendable‟ in the policy documents. Accordingly, the applicant relies on the Oxford Dictionary definition of „expendable‟ which is: “of relatively little significance, and therefore able to be abandoned or destroyed” “(of an object) designed to be used only once and then abandoned or destroyed” 17. The applicant submits that the unit which was damaged is a major core component, which is integral to the operation of the lift. It is the entire lift management system which determines the operation of the lift. In the applicant‟s view, the unit is certainly not „an expendable‟ item, as defined in the Oxford Dictionary. He submits that this view is further supported by the high cost of the unit and the fact that a unit of this type is generally expected to service a lift for its typical life span of more than 25 years. 18. The applicant has provided a report from the director of the original manufacturer and installer of the lift. Relevantly, the report states: “.. [the unit] is an integral component o f the lift itself, not an item which would or should be considered in any way shape or form to be a general maintenance item nor an item of the likes detailed within [the insurer‟s] Exclusion 2f „expendable items‟ as describe [sic] above. The microprocesso r/controller unit is not a „protective and controlling device” it is the primary electronic component which manages the operation of the lift mechanism, not some ancillary fuse/relay type protective device which would typically be referred to as expendable. ... Clearly considering the cost of this integral component to an overall lift installation, the unit would not have a classification of „expendable item.” 19. The FSP maintains its position that the unit is a controlling device and therefore comes within the exclusion it relies on. It is not clear from the FSP's submissions whether it is denying the claim based solely on its view that the unit is a controlling device, or if its position is that the unit is both a controlling device and an expendable item. 20. The Panel notes that the relevant policy provision excludes cover for “expendable items including…. protective and controlling devices.” In the 213033 Determination 4 of 5 Panel‟s opinio n, a reasonable person would understand the provision to mean that protective and controlling devices which are expendable are excluded from cover. There may well be controlling devices which are expendable and others which are not, and therefore the exclusion cannot reasonably be relied on to exclude cover for all protective and controlling devices. In any event, in the applicant‟s expert‟s opinion, the unit is not a “protective and controlling device”. 21. The FSP has not provided any evidence to support its view that the unit is a controlling device and/or an expendable item. Interestingly, the FSP has not responded directly to the report from the applicant‟s expert, nor has it responded to the applicant submissions regarding the general nature of expendable items as compared to the unit in question. 22. In the absence of any evidence to the contrary, the Panel is persuaded by the expert opinion provided by the director of the lift manufacturer/installer who states that the unit is not an expendable item and furthermore is not a „protective and controlling device‟. 23. The Panel is also persuaded by the Oxford dictionary definition of the „expendable‟ provided by the applicant. That definition indicates that expendable items are those which are of relatively little significance and are typically designed to be used only once and then abandoned. That does not describe a $49,000 unit which is generally expected to operate successfully for more than 25 years as the core operating component of the lift. 24. As the FSP is relying on an exclusion in the policy, the onus is on the FSP to establish on the balance of probabilities that the claim falls within the exclusion. The Panel is not satisfied that the FSP has established its onus regarding this aspect of the claim. Lift motor 25. The Panel notes that Policy 1 does not cover mechanical or electrical breakdown or failure caused by electric current, except for fusion of motors with an output of 5 kilowatts or less. The motor in question had an output of 17 kilowatts and therefore, the Panel is satisfied that there is no cover under Policy 1 for the damage to the motor. 26. Policy 7 provides cover for machinery breakdown, provided the insured item is in the ordinary course of working at the time the damage occurred. 27. The FSP initia lly argued that the lift was not in the “ordinary course of working” at the time the damage to the motor occurred. That position was based on information which the FSP alleged was provided to its investigator by the property manager of the insured premises. The property manager subsequently provided a Statutory Declaration in which she denies making such statements. 28. In the FSP's Notice of Response it states that it is prepared to leave this matter the lift being „in ordinary working order‟ in abeyance and t herefore the Panel will not consider it any further. 29. The FSP has declined to cover the lift motor on the basis of the policy exclusion relating to consequential loss. The FSP submits that it was the lift controller which malfunctioned and in turn damaged the lift motor. Therefore, the damage 213033 Determination 5 of 5 to the lift motor is a consequential loss which is excluded from cover under the policy. 30. The Panel does not agree with the FSP's position in that regard. In the Panel‟s opinion the damage to the motor is a direct result of the failure of microprocessor/controller unit and is part of the overall damage to the lift which is covered by the terms of the machinery breakdown policy. That the damage to the motor resulted after the failure of the processor does not in itself sufficiently separate it from the event to consider it as a consequential loss, rather it should properly be considered a direct result of the event. CONCLUSION 31. The Panel determines that the FSP is liable to indemnify the applicant in relation to the damage to the microprocessor/controller unit and the damage to the lift motor.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.