Home / Financial Firm (Unknown - Insurer) / Determination 212386
Determination 212386
Home insurance claim for swimming pool damage declined under hydrostatic pressure and faulty workmanship exclusions
Summary
The applicants claimed under their home and contents policy for swimming pool damage after storms and a leaking pipe. The FSP declined on hydrostatic pressure and faulty installation exclusions. AFCA accepted the consultant's report and found the FSP entitled to deny the claim.
Where damage has two proximate causes, one covered and one excluded, the exclusion applies to the whole loss, and hydrostatic pressure damage to pools is excluded.
Issues
- Claim denial primary · not upheld
“I conclude that the FSP has discharged the onus that rests with it to show the claim does not fall within the cover provided by the policy.”
- Inadequate claim investigation secondary · not upheld
“I am therefore satisfied that the report may be relied on for the purpose of this determination.”
Subjects and remedies
home or building damageno remedy
Text of the determination
212386 Determination 1 of 4
DETERMINATION
Case Number: 212386
Home Building – swimming pool – hydrostatic pressure - storm – broken pipe
SUMMARY OF FACTS
1. On 15 February 2010, the applicants lodged a claim under their home and
contents insurance policy for damage to their swimming pool.
2. The Financial Services Provider (FSP) denied liability for the claim on the
grounds that the damage was due to hydrostatic pressure, faulty installation of
the pool and lack of drainage all of which are excluded from cover provided by
the policy.
3. The applicants argue the damage was caused by severe storms in the area
and water escaping from broken pipes.
ISSUE IN DISPUTE
4. Whether the FSP was entitled to deny liability for the claim.
RELEVANT POLICY PROVISIONS
“ You are not covered for any loss or damage caused by or resulting from:
…
inherent defects, structural faults, faulty workmanship or faulty design;
…
damage to swimming pools, spas, septic tanks, water tanks (and other in ground
structures or their surrounds) caused by hydrostatic pressure;”
LAW INVOLVED
Section 46 of the Insurance Contracts Act 1984 (the Act) provides that if a claim is
made in respect of a loss that occurred in whole or in part as a result of a defect or
imperfection in a thing and the insured was not aware of the defect or a reasonable
person in the circumstances could not be expected to have been aware of the defect
or imperfection the insurer may not rely on an exc lusion clause that refers to the
condition of the thing before the contract was entered into.
REASONS FOR DECISION
5. I am satisfied that a full exchange of information has taken place between each
party and that each party has had the opportunity to address any issues raised.
The Applicant‟s Submission
6. Both assessors stated that the damage was caused by large volumes of water
dumped by a severe storm increasing the level of the groundwater to such a
degree the pool was pushed from the ground.
212386 Determination 2 of 4
7. The FSP denied the claim on the ground the damage was caused by
hydrostatic pressure. As a result of the denial, the applicants had the pool
repaired at a cost of $5,200.
8. However the same problem occurred less than one month later. It was since
established that broken pipes surrounding the pool were found. Water from the
broken pipes would cause the ground water to build up to such a degree that
the pressure would damage the pool.
9. They purchased the building in December 2009 and had building checks
carried out at the time.
The FSP ‟s Submission
10. A report obtained by it states that hydrostatic pressure caused the damage to
the pool but also cites ineffective support and drainage caused by faulty
installation.
11. The policy excludes damage caused by both these causes.
Cons ideration of each party’s submission
12. The FSP relies on clauses in the policy to deny liability for the claim and
therefore has the burden of establishing on the balance of probabilities that the
terms of the relevant clauses apply to defeat the claim.
13. The FSP relies substantially on a report commissioned by it from a consultant
to comment on the reason for the damage and actions taken by the applicant
regarding previous repairs and replacement of a hydrostatic valve.
14. The consultant‟s report dated 18 Ju ne 2010 contains the following relevant
information.
- The sub soil and surrounding drainage is not adequate and is contrary to
the requirements under AS/NZS Standard 1839:1992 Swimming Pools –
pre moulded fibre reinforced plastics – installation.
- The entire installation of the pool with regard to drainage is not in
accordance with the standard.
- The ease of lifting at the coping level also indicates that the concrete bond
beam has not been fixed to the pool shell to prevent separation as
required in the standard.
- The selective lifting and attempted floating of the pool on the western side
would indicate a pressure source greater tha n the reported leaks from the
solar piping. However, no such source is evident with the property being
well above the water table level and no obvious run off potential from the
adjacent property.
The report concluded;
“The damage is the result of hydrostatic pressure resulting from the combination
of leaking pipe work and extreme rain events causing a „surge‟ affect against th e
pool wall, the concrete bond beam not retaining to top of the pool and the
ineffective support and drainage caused by faulty installation”
212386 Determination 3 of 4
15. I am mindful of the applicants‟ complaint that the various assessments carried
out for the FSP were carried out by unqualified personnel. However, the report
on which the FSP relies was issued by a „Fibreglass consultant‟ and is thorough
with reasoned explanations for his findings. I am therefore satisfied that the
report may be relied on for the purpose of this determination.
16. Based on the consultant‟s report, I accept that damage to the pool was caused
by a number of factors arising from stormwater and a leaking pipe causing
pressure against the pool wall and incorrect installation techniques and
drainage.
17. The policy provides cover for loss or damage caused by storm and rainwater
and leaking or discharge from pipes. The applicant therefore has established a
prima facie claim under the policy.
18. However the policy does not cover any loss or damage caused by or resulting
from structural faults, faulty design or faulty workmanship.
19. It is a long standing principle of insurance law that where damage has two
proximate causes, one of which is covered by the policy and the other is
subject to a policy exclusion, the exclusion applies to the whole of the damage
and the FSP is not liable at all. ( Wayne Tank and Pump Co. Ltd. V Employers
Liability Assurance Corp Ltd [ 1974 ] QB 57.)
20. Section 46 of the Act, noted earlier in this determination, provides relief to
policyholders when the policyholder is not aware of the defect or imperfection
or a reasonable person could not be expected to be aware of the defect or
imperfection.
21. The applicants state that the house was purchased by them in December 2009
being about two months before the damage occurred and that an inspection
report was obtained by them before moving in.
22. In these circumstances, I am persuaded the applicants had no reason to be
aware of the structural defects or faulty workmanship and pursuant to section
46 of the Act, and are entitled to relief in relation to the application of the clause
relevant to structural defects and faulty workmanship
23. The policy further provides that loss or damage caused by or resulting from
damage to swimming pools caused by hydrostatic pressure is not covered.
24. The consultant concluded the damage was the result of hydrostatic pressure
resulting from a combination of leaking pipes and extreme rain events.
25. In these circumstances, I accept that hydrostatic pressure was one proximate
cause for the damage and the storm and leaking pipes were also a proximate
cause. As loss or damage caused by hydrostatic pressure is excluded from the
cover, the exclusion clause applies and the FSP is not liable for any of the
damage.
CONCLUSION
26. Based on this analysis, I conclude that the FSP has discharged the onus that
rests with it to show the claim does not fall within the cover provided by the
policy.
212386 Determination 4 of 4
27. Accordingly, I determine the FSP was entitled to deny liability for the claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.