Home / Financial Firm (Unknown - Insurer) / Determination 201346
Determination 201346
Storm damage to facade and floor and face tiles declined as gradual deterioration and building defects
Summary
The applicant claimed storm damage to a facade and to veranda tiles, and the FSP declined for gradual deterioration and building defects. AFCA ordered indemnity for the facade and rejected the tile claim, with quantum left to the parties.
The facade remained in place for 30 years and was damaged by the storm, but the tiles were dislodged by water entering through cracked grout from poor workmanship.
Subjects and remedies
pay claim
Text of the determination
201346 Determination 1 of 3
DETERMINATION
Case number: 201346
Home Building – gradual deterioration – structural defects
SUMMARY OF FACTS
1. On 8 October 2009 the applicant lodged a claim under his home insurance
policy for damage to the building that occurred during storms on 7 October
2009.
2. The Financial Services Provider (FSP) denied liability for the claim on the
grounds that the damage had been occurring over a number of years and was
due to wear, tear and ineffectual construction methods.
3. The dispute was considered by a case manager of the Service who issued a
Recommendation on or about 24 June 2010 in favour of the FSP on the ground
that he was satisfied that the claim was excluded from the cover provided by
the policy.
4. The Recommendation was not accepted by the applicant. Pursuant to clause
8.5(c) of the Terms of Reference of the Service, the applicant requested that
the dispute proceed to Determination.
ISSUES IN DISPUTE
5. Whether the damage was caused by a storm event, or by wear, tear and
ineffectual construction methods.
RELEVANT POLICY PROVISIONS
“You are not covered under any section of the policy for damage, loss, cost or liability
caused by or arising from or involving:
…
wear and tear, rust, deterioration or corrosion
mechanical, structural, electrical or other failure or breakdown, other than as provided for
under ‘Damage to electric motors’ on page 22.”
REASONS FOR DECISION
6. I am satisfied that a full exchange of information has taken place between each
party and that each party has had the opportunity to address any issues raised.
The Applicant’s Submission
7. The applicant states that his gutter is not faulty or rusted, nor was there any
defect in installation. As evidence he points out that it has been there for 30
years and was destroyed by the storm.
8. The applicant notes that any building will have a faulty structure. An ideal
building with perfect construction will not be found.
9. Therefore he considers that the FSP cannot rely on the excuse of a building
fault to deny the claim.
201346 Determination 2 of 3
10. Further, the metal cover on the gutter was ripped off and broken by the storm.
Tiles to the front balcony and back were also damaged by the storm.
11. The cover for the gutter had been in place for 30 years and the tiles were
renovated five years ago. This is a point stressed in the ap plicant’s further
submission when requesting a Determination.
The FSP’s Submission
12. The FSP relies on the assessor’s report.
13. The claim is for rectification of two defects, namely the gutter and the poorly
adhered tiles, for which there is no cover.
14. The damage had been occurring over a number of years and was not
consistent with a one-off storm occurrence. The damage had been occurring
prior to inception of the policy on 23 April 2009.
15. The claim for dislodgement of the façade and repair of the damage to the tiles
therefore falls outside the terms and conditions of the policy.
Consideration of each party’s submission
16. When making a claim under an insurance policy the responsibility rests with the
policyholder to show on the balance of probabilities that the cause of the
damage falls within the terms of cover. An insurer relying on terms in t he policy
to deny the claim has the responsibility to establish on the balance of
probabilities that the relevant terms apply to defeat the claim.
17. The FSP relies on the report provided by its assessor. The assessor has been
working in the home building industry for approximately 31 years as a qualified
carpenter and joiner, building supervisor, estimator and licensed self employed
builder. I am satisfied that he was appropriately qualified to examine and report
on the building damage.
18. The assessor inspected the applicant’s premises on 28 October 2009 and has
come to the conclusion that the resultant damage was due to building defects.
His report details the following:
- The f açade cladding is poorly installed. The manufacturer’s fixing clips
required to hold the façade cladding in place have not been used. Flat
head nails have been used instead.
- Floor and face tiles to the veranda have been installed over the existing
tiles and have no retaining trim as required to the edge.
- Prior cracking to the grout joints have allowed water entry and that water
spilling behind the tiles allowed the tiles to dislodge. The surrounding tiles
will continue to dislodge.
- Face tiles have fallen at the rear and damaged floor tiles surrounding the
pool area.
19. The assessor may well be correct in his view that the initial installation of the
facade 30 years ago was not carried out in the optimal manner. However, the
applicant is entitled to point to the fact that, once installed, the facade has
remained in place for 30 years. The FSP does not deny that the damage to the
facade occurred during the storm. In my opinion, it is somewhat harsh in these
circumstances to attribute the damage to the facade to the inadequate
201346 Determination 3 of 3
installation. On this aspect I have been influenced by the matters raised by the
applicant in his further submission.
20. Different considerations apply to the floor and face tiles, which appear to have
been inadequately laid some five years ago without retaining trim and in
circumstances in which the cracking to the grout joints has allowed water entry,
thus causing tiles to dislodge.
21. No acceptable evidence has been presented to me to contradict the findings of
the assessor regarding the floor and face tiles. In these circumstances I
consider the FSP was entitled to rely on the findings of the assessor’s report as
to the floor and face tiles.
22. In my opinion the evidence has established that the damage to the tiles claimed
by the applicant was the result of poor workmanship and defective building
practices. Dislodgement of the floor and face tiles occurred as a result of water
entering below the tiles through cracked grout joints. Significantly, the assessor
observed that the tiles would continue to dislodge which indicates that the
cause of the failure is ongoing and due to causes other that the storm event.
23. While the applicant informed the assessor that the damage occurred during
storms at about that time, I am satisfied the dominant cause of the damage to
the tiles was the building defects.
CONCLUSION
24. I have reviewed the policy wording and all the evidence and considered the
submissions.
25. On the basis of the above analysis, I determine that the FSP is obliged to
indemnify the applicant for the cost of rectification to the façade.
26. I further determine that the FSP is not liable for the damage claimed to the floor
and face tiles.
27. The available material does not permit me to make an assessment of quantum.
If, after consideration of this Determination, the parties cannot agree as to
quantum, either party may apply to this Service for a further Determination in
that regard.