Home / Allianz Australia / Determination 12-26-349227

Determination 12-26-349227

Refusal to vary cash settlement to cover hail damage to solar panels and reimburse expert report costs

FirmAllianz Australia
Decided2026-07-10
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed$21,733
SourceAFCA PDF

Summary

The complainant sought a variation to a hail cash settlement to replace solar panels and recover expert report costs. AFCA found in favour of the insurer as damage to the panels from the hailstorm was not established.

The complainant bore the onus to show on the balance of probabilities that the hailstorm damaged the solar panels, and the EL testing did not exclude other causes of microcracking while the insurer's thermal testing showed no damage.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Allianz Australia determinations · Find similar determinations

Text of the determination

Determination | Case number | 12-26-349227 | Financial firm | Allianz Australia Insurance Limited Case number: 12-26-349227 10 July 2026 1 Determination overview 1.1 Complaint The complainant holds a home and contents policy with the financial firm (the insurer). On 22 April 2025, she lodged a claim for hail damage to her roof following a storm on 23 January 2025. The insurer accepted the claim, and cash settled her on 6 August 2025. The complainant now seeks a variation to the cash settlement, saying that there is hail damage to the solar panels. She seeks compensation in the amount of $21,732.78 for full solar panel replacement in the amount of $13,885.13 and electroluminescence (EL) testing report costs in the amount of $7,847.65, together with the costs of an expert report. The insurer disputes the claim for variation and says there is no evidence that the solar panels have suffered damage from the hail event. The complainant is represented by a paid representative. For ease of reference, the complainant and her representative will be referred to as ‘the complainant’. 1.2 Issues and key findings Can the insurer decline the solar panel variation? Yes. The complainant has not shown that the solar panels have been damaged by the insured event and require replacement. The complainant has therefore not established that a variation to the cash settlement is required. Is the complainant entitled to professional costs? No. The complainant’s expert reports have not assisted her in establishing a claim for a variation of the cash settlement for the solar panels. The insurer is not required to reimburse the complainant for these costs. Why is the outcome fair? The outcome is fair because the complainant has not shown that the hailstorm damaged the solar panels. It would not be fair to require the insurer to vary the cash settlement when the policy does not require it to do so. It is also fair that the insurer is not required to reimburse the complainant’s professional costs, because those reports did not establish her claim for a variation. 1.3 Determination This determination is in favour of the insurer. The insurer is not required to take any further action in relation to this complaint or claim. 2 Reasons for determination 2.1 Can the insurer decline the solar panel variation? Yes. The complainant has not shown that the solar panels have been damaged by the insured event and require replacement. The complainant has therefore not established that a variation to the cash settlement is required. Complainant bears the onus to establish a claimable loss The complainant is required to show, on the balance of probabilities (that is more likely than not), that she suffered a claimable loss under the policy. This means that she must show the loss was caused by a risk for which she is insured. Once the complainant, on balance, establishes a claimable loss, the insurer is liable for the loss unless it shows an exclusion or limiting condition applies. The insurer has the onus of proving, on balance, the application of the exclusion or condition. The policy provides cover for listed insured events, including ‘storm, cyclone, rainwater or run-off’. It also offers optional accidental damage cover. The relevant renewal certificate shows this optional cover was not taken. The insurer does not dispute that there was a hailstorm. The insurer accepted the complainant’s claim for hail damage to the main roof and granny flat on 25 June 2025 and cash settled the complainant for $55,880.72. However, the parties now dispute whether the hail damaged the solar panels. Complainant says solar panels are hail damaged The complainant seeks a full replacement of the solar panel array, relying on her builder AB’s assessment that the panels are hail damaged. AB has provided a quote for its replacement. The complainant has also obtained a number of solar reports and testing to support her claim. The complainant obtained a solar report from SE dated 4 August 2025. SE found: · the hailstorm impacted the property, requiring a full replacement of the Colorbond roof, confirming the severity of the event and the significant forces sustained · hidden damage does not necessarily present as visible external cracking or breakage, is unlikely to be detected on standard visual inspection or thermal imaging · visual inspection or thermal imaging cannot reliably identify latent defects that may compromise system performance, safety or longevity · manufacturer warranties for systems typically exclude damage from hail events · no external breakage was observed, however, there is a credible basis to suspect internal damage within the solar modules · recommended full system replacement, or specialist EL testing. SE noted that several system components require replacement to ensure ongoing compliance with current electrical and safety standards: · the existing racking system is no longer serviceable due to seized and deteriorated components and must be replaced to meet the structural and safety requirements of AS/NZ 5033:2021 · system cabling must be upgraded to comply with AS/NZS 3000:2018 and AS/NZS 5033:2021 requirements for proper support, protection and segregation · DC isolators must be replaced with compliant, weather-rated enclosures and installed in accordance with AS/NZS 5033:2021 requirements. SE says that without these upgrades and without confirmation of the integrity of the module following the hail event, the system cannot be reinstated in a safe manner that is compliant or insurable. The complainant says that the solar inspection report obtained by the insurer (LE) on 15 May 2025 was flawed and therefore unreliable as the testing was undertaken in overcast condition which she says leads to: · unreliable thermal imaging · inconsistent temperature readings · low panel temperatures. SE provided a further report dated 12 November 2025 following EL testing which was undertaken by PV on five of the 18 solar panels. SE also supplied PV’s report dated 12 November 2025. The testing report prepared by PV found: · five of five modules contained microcracks · three of five modules failed due to non-critical cracks which exceeded the allowable failure threshold · one module contained a critical microcrack · the damage is consistent with hail damage. SE says that the modules are unsuitable for reinstatement and pose serious risk, including: · progressive failure, such as accelerated degradation, arcing or fire · loss of manufacturer warranty due to physical damage exclusions · electrical hazards from the operation of compromised modules. SE says that it is not possible to replace the failed modules only as AS/NZS 5033 mandates similar electrical characteristics on the same MPPT input. SE says this is rarely achievable with discontinued or hail affected modules. SE provided a supplementary report dated 4 December 2025. SE said the testing of five panels showed storm related microcracks and should be taken to indicate that the whole array has been affected by the hail event to varying degrees. SE also said the modules have been superseded and no longer available. It said second hand or mismatched panels are not acceptable because AS/NZS 5033 and AS/NZS 3000 require the system to be treated as a whole. SE says that modules with different electrical characteristics cannot be used to replace damaged modules. Therefore, when modules are obsolete, to keep the installation compliant, the affected array should be replaced with a matched set of new modules. SE provided a further report dated 13 February 2026 in response to the use of EL testing. SE says that PV did not treat all microcracking as relevant damage. Rather, SE says that PV excluded damage associated with manufacturing defects from its assessment of whether the panels passed or failed the assessment. SE says that PV can distinguish the cracks based on the different patterns, orientations and distribution characteristics. SE says that the conclusions in the EL report are not drawn from the presence of microcracks alone. SE says that they reflect the application of defined criteria that exclude non-hail related features and only assesses internal cell damage consistent with hail impact. SE provided another report dated 24 March 2026. This report focuses on the use of EL testing and why this method is preferred and more reliable than thermal imaging or visual inspections. SE says: · the absence of a hotspot on thermal imaging is time and condition dependent · a hotspot can be influenced by the electrical conditions under which it is assessed including irradiance, inverter state, load conditions and the testing method adopted, including short circuit or other forced electrical conditions · EL testing is repeatable, module specific and capable of independent verification. SE says that the panels remained at the property and were stored in a stable and protected position prior to testing. SE says that the EL testing show a result which is consistent with the claim context. SE says that the result shows a material level of hidden cell damage within the tested sample which is consistent with the hail event that resulted in the roof claim for hail damage. SE says that PV confirmed that the damage was consistent with hail. The complainant obtained a report from GT, who specialises in thermal testing. The report is dated 25 March 2026. GT reviewed the report from LE and says that it cannot be used to support any findings as there are issues with its testing, including: · the angle of incidence, which is showing reflection rather than emission, and therefore the faults are unable to be seen · spatial resolution, as the camera used had a low pixel count which resulted in poor spatial resolution, and only one image per panel should have been taken to assess its condition · span control as the images were not thermally tuned to offer useful comparison or detail. The complainant says that GT’s report shows that LE’s report is technically inconclusive and cannot be relied on to exclude damage to the solar panels. The complainant has provided copies of her electricity accounts for the period December 2024 to March 2026. The complainant says that these accounts show a declining performance trend. She says that this is consistent with her claim that hidden internal module damage may exist and impar performance over time. Insurer obtained expert reports Before cash settling the claim, the insurer appointed LE, an electrician, to inspect the solar panels and provide a report. The report is dated 15 May 2025. LE says: · the system was estimated to be approximately five years old · the system/array has not been impacted by the event · the system was tested and inspected and thermal imaging conducted which found the system was functioning as intended · there was no physical evidence of event related damage to the system · no internal damage was found in the individual solar panels or the infra-red images · when the system was tested, the output was 1.7kw which was in the expected range of the size of the system and the time of day/year. LE noted that, if the solar system was to be removed and reinstated for remedial repairs for other trades, the DC isolator, DC cable, earthing and solar rail and clamps will need to be replaced as they are not reusable and replacement is required to meet AS/NZS 5033:2021. Insurer says that complainant has not shown the solar panels were damaged The insurer disputed that the testing conducted by LE was unreliable because it was overcast as claimed by the complainant. The insurer obtained a response from LE regarding the complainant’s concerns. LE responded that while overcast conditions can affect the overall measurement of output energy from the solar array, it provides a more accurate analysis of whether the solar panels have any affected cells present, as the thermal difference is much greater in comparison to normal conditions. The insurer relies on comments from LE regarding EL testing. LE says that it, and other solar contractors, do not consider EL testing accurately accounts for damage caused during manufacturing, transport or installation. However, the standard IR and IV testing provides a more accurate analysis of the overall performance of the solar panels. The insurer sought to obtain a further opinion regarding the EL testing from EP. However, the insurer reports that EP advised that EL testing and PV’s test report was not the industry standard and therefore it was unable to comment on it. The insurer declines the variation request because it says the complainant has not shown that the solar panels were damaged by the insured event. It relies on LE’s report which found that the solar panels were undamaged and were functioning properly. It says that SE found no physical damage to the solar panels and its report is inconclusive. The insurer says that EL testing is not industry standard and LE has advised that it is inaccurate. The insurer says that any claimed damage must be directly attributed to the insured event explicitly covered by the policy. It says that while the hail damage to the roof was accepted, it does not automatically extend coverage to the solar system under the same hail event. Complainant has not established solar panels were damaged by hailstorm The complainant relies on EL testing. She has not provided other testing, such as thermal imaging, to support her claim. GT criticised the thermal testing undertaken by LE, but I place limited weight on those comments. GT did not retest the panels or provide information showing that a different result would have been obtained using another method. The complainant says that EL testing can distinguish between cracks which occur from manufacturing, transport, handling or installation. The complainant says PV distinguished cracks based on their pattern, presentation and context, and found they were consistent with hail. However, the report from PV says: At the request of the client, these modules have been analysed only for microcracks only [sic]. Microcracks that are unlikely the result of storm damage and likely the result of manufacturing defects have been excluded from our markup and pass/fail assessment. Any other features, severe or otherwise are not marked. I am not persuaded based on PV’s comments, that microcracking from transport, handling or installation or removal can be excluded in this testing. PV says it excluded manufacturing defects only. It is possible that the microcracks arose from another cause, including the removal of the solar panels from the roof, despite the complainant’s claim that they were stored safely before testing. The complainant argues the entire solar panel system requires replacement because the EL testing showed a critical crack in one panel and microcracks in others. However, PV’s testing excluded manufacturing defects, severe or otherwise, from its reporting. Even if I accepted that a storm caused damage to one solar panel, I could not be satisfied on that basis alone, that the whole system required replacement. If there were other critical cracks or microcracks caused by manufacturing defects, based on the complainant’s own submissions, the solar panels would have required replacement before the storm event. The complainant says that the panels are damaged as there has been a physical alteration that impairs condition, value or usefulness. She says that the microcracking of the solar panels affects their condition and reliability and creates a materially increased risk of progressive deterioration if the system continues to operate for a time. In support, the complainant relies on electricity accounts which she says show a decreased performance since the insured event. I have reviewed the electricity accounts provided by the complainant. While I acknowledge that there are variations in usage from the previous year, I do not accept the complainant’s submission that these accounts show the declining performance of the solar panels. This is because usage, even across the seasons, varies from year to year. Usage is influenced by: · seasonal daylight variation · household consumption changes · appliance usage. I am not satisfied that there is information showing the solar panels are working less effectively, or that their usefulness has decreased. Any loss of value appears to relate to their age and compliance issues, rather than microcracking. While the complainant says that microcracking can compromise performance, safety and longevity, this is merely speculative. The complainant has not provided any information in support of such as a reduction in the performance of the system. I am not persuaded that the complainant has shown the storm caused the damage claimed. I am more persuaded by the thermal testing undertaken by LE. This was when the solar panels remained installed and no internal damage was found in the individual solar panels or the infra-red images. This is consistent with it being shown that there is no reduction in the performance of the system. I am not satisfied that the EL testing is definitive in establishing that the solar panels have been damaged by the hailstorm. It follows that the complainant has not established a claimable loss under the policy and the insurer is entitled to deny the variation claim. It is unnecessary to consider whether any policy exclusions apply. 2.2 Is the complainant entitled to professional costs? No. The complainant’s expert reports have not assisted her in establishing a claim for a variation of the cash settlement for the solar panels. The insurer is not required to reimburse the complainant for these costs. AFCA may require insurer to contribute to a complainant’s professional costs The AFCA Rules enable AFCA to require an insurer to contribute to the professional costs incurred by the complainant. These costs are, however, usually capped at a total of $5,000, unless special circumstances apply. When considering whether to require an insurer to make a costs contribution, AFCA takes into account the complexity of the complaint and whether the particular complainant needed to incur costs to understand or establish their claim. Insurer is not required to reimburse professional costs The complainant seeks reimbursement for the following reports: · $7,847.65 for AB’s invoice which includes EL testing for $6,539.71 undertaken by PV and a builder’s margin of 20% · $330 for a report from GT. As these reports have not assisted the complainant in substantiating her position, I am satisfied that the insurer is not required to reimburse her for these costs. 2.3 Why is the outcome fair? The outcome is fair because the complainant has not shown that the hailstorm damaged the solar panels. It would not be fair to require the insurer to vary the cash settlement when the policy does not require it to do so. It is also fair that the insurer is not required to reimburse the complainant’s professional costs, because those reports did not establish her claim for a variation. 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to: · the legal principles · applicable industry codes or guidance · good industry practice · previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. I have reviewed and considered all the information the parties have provided. While the parties have raised several issues in their submissions, I have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider: · available documents · the recollections of the parties · all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.