Summary

The complainant sought full solar panel replacement and report costs after hail damage, after the insurer had cash settled the roof repairs. AFCA found in favour of the insurer, as hail damage to the panels was not established and there was no mishandling.

The complainant bore the onus to show hail damage to the panels, and her thermal and EL evidence was unreliable due to testing flaws and chain-of-custody gaps, while the insurer's testing found no damage.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All IAG determinations · Find similar determinations

Text of the determination

Determination | Case number | 12-25-201424 | Financial firm | Insurance Australia Limited Case number: 12-25-201424 20 February 2026 1 Determination overview 1.1 Complaint The complainant holds a home building insurance policy (policy) covering listed events and accidental damage with the financial firm (insurer). On 25 July 2023, a claim was lodged for hail damage resulting from a storm event on 26 May 2023. The insurer accepted the claim. Relying on its builder’s (AS) report finding no visible hail damage to the solar panels, it cash‑settled the complainant $77,436 for all hail‑related repairs, including removal and reinstatement of the undamaged panels. The complainant later sought a variation for full solar panel replacement ($12,456), which the insurer declined on the basis the panels were not hail‑damaged. The complainant disputes this, seeking the full variation amount (less what was already paid), reimbursement of her expert report costs ($7,582), and compensation for non‑financial loss (NFL). A representative has assisted the complainant. Any reference within this determination to the complainant will include a reference to the representative unless otherwise stated. 1.2 Issues and key findings Has the complainant established a valid variation claim? No. This is because the exchanged information does not show, on the balance of probabilities (that is, more likely than not), the solar panels have sustained damage from the hail event that occurred on 26 May 2023. Is the complainant entitled to report fees? No. This is because the complainant’s reports did not assist in resolving the complaint. Did the insurer mishandle the claim? No. This is because the exchanged information shows the insurer’s overall handling of the variation claim was reasonable. The complainant is not entitled to NFL. Why is the outcome fair? The outcome is fair because the evidence does not show the solar panels were hail‑damaged, and the complainant has not established a valid basis for the variation. Her expert report did not assist in resolving the dispute, so it would be unfair to require the insurer to reimburse this cost. The insurer did not mishandle the claim, and there is no basis for NFL. 1.3 Determination This determination is in favour of the insurer. The insurer is not required to take any further action. 2 Reasons for determination 2.1 Has the complainant established a valid variation claim? No. This is because the exchanged information does not show, on balance, the solar panels have sustained damage from the hail event that occurred on 26 May 2023. Complainant has onus to establish a valid claim It is accepted insurance law that the complainant carries the initial onus to establish, on balance, a loss which is covered by the terms and conditions of the policy. Only if the complainant can do this, will the onus shift to the insurer to show, on balance, it is entitled to decline cover in line with the policy wording or otherwise. Policy covers insured events and accidental damage The policy covers insured events. This means that not all loss and damage is automatically covered. Rather, only loss or damage caused by one or more of the insured events occurring during the period of insurance and not subject to the exclusions, is covered. One of the insured events listed under the policy is ‘storm’ including hail. Optional accidental damage cover was also purchased. However, damage covered under a listed event is excluded. ​On 25 July 2023, the complainant lodged a claim for storm (hail) damage. There is no dispute a hailstorm occurred which caused damage to the roof. However, the dispute is about whether hail damaged the solar panels. Complainant says solar panels are hail damaged The complainant seeks full replacement of the solar panel array, relying on her builder AB’s assessment the panels are hail‑damaged. She also cites an HP roof inspection report identifying severe hail damage to the corrugated roof. She says this supports the likelihood of impact damage to the solar system. The complainant relies on a solar report from SZ to support the variation claim. SZ attended the property on 30 January 2024. In its report dated 8 February 2024, SZ says: · thermal imaging identified multiple significant hotspots across several panels · hotspots were interpreted as micro‑fractures consistent with hail impact · roof shows confirmed hail damage, which logically aligns with alleged panel damage · technician holds ISO 18436‑7 Category 1 thermography certification and used a FLIR E96 high‑end thermal camera · hotspots pose fire risk, efficiency loss, and long‑term reliability issues · assessment consisted of visual inspection and thermal imaging only · no electrical testing was conducted · hail caused micro‑fractures in the solar panels · full system replacement is recommended due to number and spread of hotspots · compliance certificate cannot be issued while thermal anomalies remain. In addition, an electroluminescence (EL) test was performed by PV on three of 20 solar panels. Its report dated 13 August 2024 was also supplied by SZ. The testing report prepared by PV found: · one of the three modules showed critical microcracks, while the other two passed · it is possible the damage is consistent with hail · panels arrived not in original packaging; sampling was sent by client · modules analysed for microcracks only · testing performed off-site. Complainant says solar panels suffered performance loss The complainant says the solar panels have had a significant performance loss since the hail event. She cites quarterly electricity‑bill data for 2022–2024 to show changes in household energy costs. She says: · 2022 reflects normal solar performance, 2023 shows a small increase after the May 2023 hailstorm, and 2024 shows a large increase because the solar panels were removed in April 2024 and not reinstalled · the high April 2024 –July 2024 bill led them to buy new panels, which were installed in October 2024. · the next bill returned to around 2023 levels, which she says is proof the previous panels had reduced output Based on this, she believes the higher 2024 bills demonstrate the original panels were damaged by hail. Insurer says solar panels are not hail damaged As part of the initial claim assessment the insurer obtained a solar panel report from AS. AS did an inspection shortly after the hail event to determine if the solar system was damaged. Its report (27 July 2023) found: · inverter operating normally, producing expected output while inspector was onsite · no cracks, breaks, or visible damage to any of the panels during aerial/visual inspection · no system faults or error messages observed · no hail damage. On 11 December 2023 the parties agreed to finalise the claim by way of cash settlement for hail damage repairs to the roof. The settlement included the cost to remove the existing solar panels and replace them on completion of the roof repairs. Subsequently, the complainant lodged a variation claim for a full solar panel replacement on 9 April 2024. The insurer appointed YR to perform a secondary onsite assessment of the solar panels. YR inspected the panels on 25 July 2024. In its report dated 13 August 2024 it found: · thermal scan showed no hotspots or anomalies · electrical testing found: > short‑circuit current passed > insulation resistance passed > strings operating normally. · visual inspection found no cracks, impact marks or visible damage to any panel · roof hail impacts were minor and not in a pattern consistent with panel damage · hail marks were mainly on eastern elevations, with only minimal impacts on the northwest elevation where panels sit · the 30.8° panel pitch, facing the storm direction, makes direct hail impact unlikely due to deflection · SZ’s hotspots were identical on all panels, inconsistent with hail damage · these hotspots were possibly caused by incorrect testing methodology · states SZ thermal scan conditions were non‑compliant (improper angle, no irradiance data). Based on the above, YR concludes the system is operating normally with no evidence of storm damage to the solar panel array. It says SZ thermal anomalies are unreliable. The insurer denied the variation claim on 4 September 2024 citing damage is not consistent with a single insured event and falls within general exclusions. Complainant disputes YR’s findings, submits further EL report In response to YR’s findings, the complainant submits: · SZ thermal and EL testing showed internal anomalies consistent with damage · uniform hotspot patterns can still result from panels exposed to the same storm forces · wind‑driven hail can impact even at a steep roof pitch · microcracks may not be visible, and panels can still function despite internal damage. Overall, the complainant considers SZ’s assessment more reliable and supports full panel replacement. She also relies on a supplementary EL report dated 3 October 2025. The only substantive difference between the EL reports is the earlier version stated it was ‘possible’ the damage was consistent with hail. The later version revised this to state the damage ‘is consistent with hail,’ removing qualifying language in the result summary without altering any test data or findings. Parties exchange further submissions Both parties made further submissions revisiting the main areas of disagreement, particularly the reliability of the expert reports and the qualifications behind them. The complainant relies on SZ thermal findings and PV’s EL testing as evidence of hail‑related microcracking. She says YR has not provided the EL‑specific qualifications supporting its conclusions, especially compared with PV’s recognised EL expertise (Dr M). The insurer says no formal EL‑testing licence exists, that YR is adequately qualified, and relied on independent endorsement to support its methodology. The submissions continued to focus on the same disputes over the validity of the thermal anomalies, the weight of the EL results, and whether the defects could be attributed to the hail event. Relevantly, YR raised concerns about the reliability of the complainant’s evidence. It notes the solar panels were removed, moved, and stored while the claim was still under assessment, preventing any independent verification of their condition at the time of removal and creating a break in the chain of custody. Insurer’s concerns not adequately addressed I have carefully considered the exchanged information. I am not satisfied the complainant has adequately addressed YR’s concerns about the break in chain of custody or the non‑compliant thermal testing. YR confirms the panels were removed, moved and stored while under assessment, preventing verification of their condition at removal. In response, SZ says the modules were tested at the time of removal and then safely reinstated in their original positions, in a controlled manner consistent with standard diagnostic practice. However, I am not satisfied this response adequately addresses the chain‑of‑custody concern. This because it does not: · identify who handled the panels · how they were transported or stored · whether environmental or mechanical conditions were controlled or documented · if any independent verification confirmed that no damage occurred during movement. Without this detail, the possibility that cracks developed during removal, handling, or reinstatement remains untested. SZ does not provide irradiance measurements or demonstrates compliance with the required thermal‑imaging standard, despite YR identifying these omissions as critical defects in the testing methodology. As a result, its submissions do not resolve the evidentiary concerns. I consider the reliability of the complainant’s thermal, and EL evidence is significantly undermined. SZ findings are not persuasive I do not find SZ’s findings persuasive. This is because its thermal testing does not include irradiance measurements, and scanning was performed from an incorrect angle, making the reported hotspots unreliable. The hotspots also appear in identical patterns across all panels, which YR explains is inconsistent with hail. It says this is more consistent with incorrect testing methodology. SZ’s report acknowledges no physical damage was observed during inspection. Despite this, it concludes hail caused ‘micro‑fractures’ and ‘structural damage,’ even though the report is limited to visual and thermal imaging only and explicitly states it includes no electrical testing or analysis beyond what is visible. The thermal images lack irradiance and capture‑condition data, making the hotspot interpretation unreliable. The report claims fire risk, long‑term degradation, voided warranties, and inability to issue a compliance certificate, none of which can be supported without electrical testing, structural evidence, or compliance assessments. By contrast, YR’s thermal, electrical and visual testing found no anomalies or cracking. The PV test results do not corroborate SZ’s findings. For these reasons, I am not satisfied the SZ’s reports are persuasive in establishing hail damage. EL test results not conclusive on causation I have carefully considered the PV’s EL reports authored by Dr M, a highly qualified solar cell specialist with extensive experience in EL diagnostics. However, Dr M’s qualifications do not overcome the fundamental evidentiary weaknesses in the EL testing. PV confirms the modules tested were supplied by the client, the sampling method was set by the client, and the modules arrived not in original packaging. This means there is no verified chain of custody, and the condition of the panels at the time of removal from the roof is unknown. YR records the solar panels were removed while still under claim review, preventing any independent observation of the removal or handling process. I am satisfied EL imaging detected microcracks. I am not satisfied PV’s statement the cracks are ‘consistent with hail,’ provides a causal link between the hail storm event on 26 May 2023 and the damage. This is because the statement describes presence of the cracks, not what caused them. Arguably, cracks with a similar shape can also be created by lifting the panels, twisting them during removal, pressure during transport, or stress when the panels were stored or re‑installed. Because the panels were removed, handled, moved, and delivered to the laboratory before testing, and PV does not know what condition the panels were in when they were taken down, the presence of the cracks alone cannot establish that hail caused them. For this reason, a statement that cracking is ‘consistent with hail’ is not a finding hail caused the cracking. It cannot overcome the break in chain‑of‑custody or the absence of a causation analysis in the EL report. Electricity bill data does not prove reduced performance I am not satisfied the electricity‑bill data is a reliable indicator of reduced solar performance. This is because bills only show net usage and charges, not the actual solar generation output. They are influenced by numerous unrelated factors such as: · seasonal daylight variation · household consumption changes · appliance use · tariff differences. The complainant’s bill data mixes different time periods without accounting for these variables. There is no inverter or generation data showing a measurable drop in output. Two technical inspections found no solar panel damage. I am not persuaded general bill patterns can override expert evidence regarding system condition. On balance, complainant has not established solar panels are hail damaged I have carefully considered all the exchanged information. On balance, I am not satisfied the complainant has established a valid claim for hail damage to the solar panels. This is because all thermal, electrical, and visual testing conducted by YR and the insurer found no hotspots, no cracks, and no evidence of hail impact. The system was found to be operating as intended. In contrast, SZ’s findings are arguably not compliant with the required thermal‑imaging standard because: · they contain no irradiance measurements · were taken from an improper angle · show identical hotspot patterns inconsistent with natural hail distribution. Further, the complainant does not adequately address the break in chain of custody, with YR confirming the panels were removed, moved and stored during assessment. The complainant’s evidence is compromised by unreliable testing and unresolved custody issues. The insurer’s testing shows no hail‑related damage. On balance, I am not satisfied the complainant has demonstrated the panels were damaged by hail. A valid claim has not been established. The insurer is entitled to deny the variation claim. 2.2 Is the complainant entitled to report fees? No. This is because the complainant’s reports did not assist in resolving the complaint. AFCA’s approach to professional costs Under the AFCA Rules, we can require an insurer to contribute to legal costs, other professional costs, or travel costs a complainant incurred in making a complaint. AFCA cannot award professional costs of more than $5,000 unless there are special circumstances. When considering whether to require the insurer to make a costs contribution, we consider the complexity of the complaint and whether the complainant needed to incur the costs to understand or establish their claim. Complainant not entitled to report fees The complainant seeks reimbursement of the cost of the EL report in the amount of $7,582. I am not satisfied it is reasonable to require the insurer to reimburse this amount. This is because the EL report was obtained to dispute the variation claim denial. As the complainant was not successful in overturning the insurer’s declinature, it is not required to reimburse the complainant’s report fee. 2.3 Did the insurer mishandle the claim? No. This is because the exchanged information shows the insurer’s overall handling of the variation claim was reasonable. The complainant is not entitled to NFL. AFCA approach to non-financial loss ​Under the AFCA Rules, AFCA can award up to $6,300 compensation for non-financial loss. We will only award this type of compensation if a complainant suffers an unusual degree of stress, inconvenience, or delay because the insurer mishandled the claim. We recognise making a claim can be stressful and time-consuming, even if the insurer handles the claim correctly. We will not award compensation for the ordinary degree of inconvenience that comes with making a claim. We may reduce the amount of compensation we award if the loss was partially caused by the actions of the complainant, or by factors outside the insurer’s control. Insurer not required to pay NFL The complainant is seeking NFL compensation for undue delays and stress caused by the insurer’s claims handling. However, I am not satisfied she is entitled to NFL compensation. This is because the available evidence shows: · the insurer’s decision to deny the solar panel variation was reasonable, supported by its expert reports · the insurer actively managed the variation claim between April 2024 and October 2024, with documented steps showing continuous progress, timely referrals, expert engagement, and clear communication, rather than any unreasonable delay · the complainant materially contributed to delays, including: > failing to arrange scaffolding despite clear instruction and prior insurer‑funded payment for it > delaying coordination and ultimately refusing to organise the required scaffolding > removing solar panels before technical assessment, prejudicing evidentiary reliability > creating procedural delays through multiple complaint escalations and slow communication I am satisfied these actions impeded timely assessment and shifted the cause of delays away from the insurer. Given the insurer’s reasonable conduct, expert‑supported decision, and the complainant’s role in delays, the complainant is not entitled to NFL compensation, as no insurer error or unreasonable delay is established. Th insurer is not required to pay NFL compensation. 2.4 Why is the outcome fair? The outcome is fair because the evidence does not show the solar panels were hail‑damaged, and the complainant has not established a valid basis for the variation. Her expert report did not assist in resolving the dispute, so it would be unfair to require the insurer to reimburse this cost. The insurer did not mishandle the claim, and there is no basis for NFL. 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to: · the legal principles · applicable industry codes or guidance · good industry practice · previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider: · available documents · the recollections of the parties · all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.