Home / Auto & General / Determination 12-24-178767

Determination 12-24-178767

Insurer declined claim for bathroom water damage, attributing it to inadequate shower base fall and deteriorated grout and silicone rather than a leaking pipe

FirmAuto & General
Decided2025-11-06
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainants claimed for bathroom water damage which they said was caused by a leaking pipe. The insurer declined, and AFCA found the insurer entitled to decline because the complainants did not show an insured event caused the damage.

The complainants bore the initial onus to show the proximate cause was an insured escape of liquid, and the evidence favoured inadequate shower fall and deteriorated grout and silicone instead.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Auto & General determinations · Find similar determinations

Text of the determination

Determination | Case number | 12-24-178767 | Financial firm | Auto & General Services Pty Ltd Case number: 12-24-178767 6 November 2025 1 Determination overview 1.1 Complaint The complainants made a claim under their home insurance policy (policy) with the financial firm (insurer) for water damage in their bathroom. The insurer declined the claim because it says the damage was caused by inadequate fall in the shower base along with deteriorated grout and silicone. The complainants dispute that decision and say the damage was caused by a leaking pipe. 1.2 Issues and key findings Is the insurer entitled to decline the claim? Yes. The information does not show the damage was caused by the escape of liquid. Why is the outcome fair? The outcome is fair because it is consistent with the clear terms of the policy. 1.3 Determination This determination is substantially in favour of the insurer. The insurer is entitled to decline the claim. 2 Reasons for determination 2.1 Is the insurer entitled to decline the claim? Yes. The information does not show the damage was caused by the escape of liquid. Onus on complainants to show loss covered by terms of the policy The complainants carry the initial onus to show on the balance of probabilities they have suffered a loss caused by a risk insured under the policy. If the complainants establish they have suffered a loss covered by the policy, the onus shifts to the insurer to show an exclusion applies. Subject to its conditions and exclusions, the policy provides cover for loss or damage caused by the insured events listed in the Product Disclosure Statement (PDS), including escape of water. Relevant extracts of the policy’s PDS are set out in section 3.2 of this determination. Parties dispute the cause of damage On 22 July 2024, the complainants lodged a claim with the insurer for water damage. The insurer engaged a builder [FZ] to assess the damage. The insurer declined the claim because it said the damage was caused by inadequate fall in the shower base and deteriorated grout and silicone. FZ concludes in its 13 August 2024 report: Upon investigations, our leak detection provider has determined that the cause of damages to the affected area to be consistent with inadequate fall to the shower base and deteriorated grout and silicone. These are allowing water to escape resulting in the claimed damages. Pipes have been tested and no leaks or loss in pressure have been noted. In principle, the cause of damages that exist is a combination of factors including, installation, general deterioration, wear and tear over past years of service life. The insurer also engaged a plumber [AX] to undertake leak detection testing. Its report dated 13 August 2024 says: Leak detection investigation has determined the cause of damage to the affected area to be consistent with inadequate fall to the shower base and deteriorated grout and silicone. These are allowing water to escape resulting in the claimed damages. Areas of maintenance outlined above require rectification by the Insured, to ensure any potential future damages are mitigated. There were no further escape of liquids identified throughout our investigation, contributing to the claimed event on site at our time of attendance. The complainants say: We believe the entire issue began via a plumbing leak (within our walls) somewhere between 4th May 2022 and Jan 2024. They say they think a pipe leak (which was repaired) in the plumbing of the vanity basin caused the shower base to drop, which caused the leak to the hallway. They think the leak remained undetected for a considerable time, creating a flow on effect to the stumps and flooring which caused the shower to leak. They have provided a letter from [LX], a handyman who says he fixed this leak in 2023. His letter dated 30 August 2024 concludes: CONCLUSION : The shower base ‘corner’ could not have sunk 1cm or more due to any other cause than by water saturation of the flooring ,pooling in the shower was the end result of slow water leakage from the cold water pipe inlet behind the vanity ,which was repaired. LX has provided a detailed explanation of the steps he took to locate and repair the leak. The complainants have also provided an invoice from a plumber dated 4 May 2022 relating to a service call for a smell coming from under the house. The plumber did not locate a leak at this time. FZ says by email, in response to LX’s letter: The claim of a long-term leak approx. 2m away from the shower recess as claimed within the report is difficult to acknowledge as the definitive causation of shower flooring saturation causing deformation to the shower recess floor substrate. The property subfloor is stumps and bearers with structural floor and tiling. By way of physical laws of gravity, any claimed leak 2m away would saturate the immediate leakage zone and floor. We do not perceive that a water path of 2m could possibly cause structural floor to compress as stated by the insured’s plumber. The shower polymarble base would have had a slurry of concrete installed beneath to secure and make firm the base and prevent base fracture. FZ also says: Leak detection has confirmed via thermal imagery, that current leakage issues are emanating from the screen and base and located to the corner of the base that exhibits long term damages. The damages are consistent with long term Escape of Liquid from as advised by our leak detection professionals, “consistent with inadequate fall to the shower base and deteriorated grout and silicone.” The complainants provided a report from building consultant [AX] dated 3 September 2025. AX concludes: After inspecting the property, in my professional opinion I believe that the movement of the structural floor in this area was possibly caused by a significant amount of water. Significant damage was not caused by cracked grout or degraded silicon. There has been significant movement in this area of the property which was either caused by a significant pipe leak or structural movement of the house in this area. Access to the subfloor is required to determine if any structural damage was caused by a significant leak over a long period of time or general subsidence of the house in this area. Excess water can compromise the structural stability of stumps, as does high moisture and mouldy conditions. My previous experience in this field was waterproofing and tiling for a 35 year period and I have provided my professional opinion on this report. No insured event established It is possible the inadequate shower fall, grouting and silicon failures have not been the sole cause of the damage. This is because there appears to have been movement, which could be a result of the now fixed water leak. This is because: · photographs of the grouting failure appears consistent with the impact of ground movement · AX’s report supports this conclusion. However, the onus is on the complainants to show an insured event (i.e. escape of liquid) has in fact occurred. AX says it was possibly caused by a leak. There is evidence showing there was a significant leak (now repaired), which could have possibly caused ground movement. The insurer’s experts did not locate a leak because it had been previously repaired. However, the evidence does not establish this leak caused the claimed damage. On balance, I am not satisfied the information available shows the proximate cause of the damage was a leaking pipe. This is because the evidence shows the damage was caused by inadequate fall in the shower base and deteriorated grout and silicone. This is supported by leak testing, photographs and the insurer’s expert’s persuasive opinion. As the complainant has not satisfied the initial onus to show an insured event covered by the policy caused the damage, the insurer is entitled to decline the claim. 2.2 Why is the outcome fair? The outcome is fair because it is consistent with the clear terms of the policy. 3 Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to: · the legal principles · applicable industry codes or guidance · good industry practice · previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider: · available documents · the recollections of the parties · all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. 3.2 Relevant Policy Provisions | Product Disclosure Statement (Prepared on 1st March 2021) | Page 36 - 37 Escape of liquid You are covered for Loss or damage at the insured address caused by the sudden escape of liquid. You are also covered for damage from liquid that has escaped slowly over time that you couldn’t be reasonably aware of. The escape of liquid from the following things: • appliances: washing machines, dishwashers, refrigerators, freezers, and water collection trays inside refrigerators or freezers • fixed items: baths, sinks, toilets, basins, other fixed plumbing apparatus, pipes, taps, gutters, and drainpipes • fixed systems: drainage or sewage systems, heating or cooling systems, or sealed portable units or tanks • water-filled items: aquariums and waterbeds. Reasonable costs to investigate the escape of liquid if it is causing damage to your home or contents You may not know the source of the escape of liquid. If we accept your claim, we will pay reasonable costs to locate the source of the escaped liquid at the insured address using the most suitable method of investigation. This does not include repairs to any burst pipe or other leak source. We will repair the damage to your insured home and contents caused by necessary exploratory work. You are not covered for The cost of repair or replacement of the item that the liquid escaped from, nor the liquid itself. For example, we do not cover the cost of repairs or replacement of a leaking shower floor, base, walls, glass screening, doors, tiles, pipes, or grouting. Loss or damage: • caused by leaking shower floors or bases, shower and bath combinations, tiled roman baths, or shower recess walls .... | Page 58 – 62 General Exclusions: What this policy will never cover Some events and causes are never covered by this policy. These are known as ‘General Exclusions’ and apply to the whole policy. You are not covered for any loss, damage, or legal liability you incur resulting directly or indirectly from events and causes listed below. … Gradual deterioration You are not covered for loss or damage caused by rust, corrosion, rot, mould, rising damp, mildew, wear, tear, fading, or other gradual deterioration. … Poor condition You are not covered for loss or damage you incur because: • you have not done building work to the home requested by a relevant authority before the loss or damage occurred; or • you have not kept the home or contents in good condition and existing defects or faults contributed to or caused the loss or damage.