Home / Suncorp Group / Determination 12-00-1051892

Determination 12-00-1051892

Refusal to cover bathroom waterproofing and reinstatement after escape of liquid

FirmSuncorp Group
Decided2024-12-02
ProductGeneral Insurance · Business / commercial
OutcomeFor the complainant
Amount awarded$11,570
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The complainant's claim for escape of liquid damage from leaking bathroom pipes was partly accepted, but the insurer declined the bathroom waterproofing and reinstatement. AFCA found the insurer liable for those costs and ordered a further $11,569.80, less the $3,470 already paid.

Escape of liquid cover extends to reinstatement costs because demolition was needed to locate and access the leaking pipes, and the shower base was not the proximate cause.

Issues

Subjects and remedies

home or building damagepay claim

Related

All Suncorp Group determinations · Find similar determinations

Text of the determination

Determination | Case number | 12-00-1051892 | Financial firm | AAI Limited Case number: 12-00-1051892 29 November 2024 Determination overview Complaint The complainant holds a business insurance policy with the financial firm (insurer). On 30 May 2023, the complainant lodged a claim for property damage to the building caused by a leaking pipe. The complainant engaged a plumber who identified the cause of damage to be a split fitting to the shower head. The insurer partially accepted the claim and agreed to pay for damage to the downstairs ceiling and walls. After this, the complainant identified further leaks. The insurer said this was due to a leaking shower base which is excluded under the terms and conditions of the policy. The complainant engaged a builder to strip out the bathroom. He identified a further leaking pipe behind the wall in the bath. He said this was leaking down the wall underneath the tiles causing damage. The insurer has accepted resultant damage for the leaking pipes. However, it has declined to cover any repairs to the bathroom. The complainant says the bathroom had to be stripped out to identify the leaking pipes. Given that the bathroom was constructed before waterproofing was required, the bathroom now needs to be waterproofed to be reinstated. The insurer has declined this aspect of the claim. Issues and key findings Has the insurer met its policy obligations? No. The insurer is to pay the complainant a further $15,039.80 to meet its policy obligations. Why is the outcome fair? The outcome is fair because the complainant is covered for escape of liquid events. It is not in dispute that there were two leaking pipes in the bathroom that caused the damage. The complainant had to remove wall tiles to access one of the leaking pipes to be repaired. The bathroom cannot be repaired without it now being waterproofed. On that basis, it is only fair that the insurer is liable for the costs to repair the damage, which includes reinstating the bathroom. Determination This determination is substantially in favour of the complainant. Within 14 days of the complainant’s acceptance of this determination, the insurer is to pay the complainant $15,039.80 in settlement of the claim. Reasons for determination Has the insurer met its policy obligations? No. The insurer is to pay the complainant a further $15,039.80 to meet its policy obligations. Onus on complainant to establish a valid claim The complainant is required to show, on the balance of probabilities (that it is more likely than not), that there is a claimable loss under the policy. This means the complainant must prove the loss or damage was caused by a risk that is covered under the policy. Once the complainant proves there is a claimable loss, the insurer is liable for the loss unless it shows an exclusion or limiting condition applies. The insurer has the onus of proving, on the balance of probabilities, that the exclusion or condition applies. Policy covers water damage subject to exclusions ​The insurer’s policy consists of the policy schedule and product disclosure statement (PDS). It is not in dispute the insurer provided the policy documents to the complainant. The policy is an ‘insured events’ policy. This means not all loss and damage is automatically covered. Rather, only loss or damage caused by an insured event, and not subject to an exclusion, is covered. The insured events are set out in the PDS and includes cover for escape of liquid. The escape of liquid cover includes: We cover loss or damage caused directly or indirectly by: the discharge or leaking of water from any damaged pipe, water system (including a fire protection system such as a sprinkler system), tanks or drains installed in and servicing the building; The insurer accepts the complainant has made a valid claim for two leaking pipes in the bathroom. The insurer says it is liable solely for the damage from the leaking tee joint and that all other damage is excluded under the policy because it is: wear and tear gradual deterioration, or damage caused by a leaking shower base. It says these are maintenance issues and the responsibility of the complainant. There are several causes of the escape of liquid The tenants of the building notified the complainant’s property manager that water was leaking through the ceiling of a pizza restaurant from the unit above. A number of experts have been engaged to comment on the cause and extent of the damage. LP (a plumber) was engaged initially by the property manager to repair the damage. He identified that there was water dripping through the gyprock ceiling from the unit above (about one drop every 10 seconds). He located a deep crack in the concrete slab below the bathtub which allowed water to drip through to the premises below. He said the concrete slab was wet and chalky and crumbled easily. He conducted some tests, including a flood test of the shower base but said this made no difference to the water dripping through. Ultimately, he identified there was a split fitting in the pipework in the shower wall and repaired that damage. LP said that if the leak continued, it could be a waterproofing issue but was not definitive in his reasoning. The complainant lodged a claim and the insurer sent CB (builder) to inspect the damage. CB noted that water was still dripping through the ceiling from the unit above. He observed that there was no waterproofing in the bathroom above and said that based on LP’s report, the damage was caused by a waterproofing issue. He said that the damage was caused by a lack of maintenance, gradual deterioration or not adhering to Australian standards. CB arranged for PP, a plumber, to attend and conduct leak detection testing. PP said there was deteriorated grout and cracking in the shower base. His flood test of the shower base resulted in water leaking below. He also tested the pipes in the shower and they passed. He was not able to test the bath pipes because the spout could not be removed. The complainant then questioned this and the insurer agreed to send PP back to look at the bathroom taps. PP removed and replaced the taps and the spout in the bath and said it then passed a pressure test. After this, the claim was closed but the leaking continued. The complainant engaged a plumber, BP, who fixed another leaking pipe and a tiler, NS, to begin removing the tiles from the bathroom. This is because the insurer had raised maintenance issues. On 8 November 2023, the complainant emailed the insurer attaching a video of more leaking. On 27 November 2023, the complainant said that as NS was removing tiles, he followed a moisture leak to the bathroom taps. The insurer sent out its own builder, JG, who agreed with the complainant’s plumber that leaking water from the tee joint of the bath taps has allowed water to track behind the tiles and under the floor. This passed through penetrations in the ceiling below because there was no waterproofing present. The complainant’s tiler, NS, provided a report that says: A work order was received to explore the extent of damage to the walls resulting from leaking pipes within the wall of the shower which had reportedly been repaired, identify if there were any further leaks, and replace the tiles in the shower recess in Unit 1. The removal of the shower tiles identified that the wall beneath the tiles was completely water-logged, with the render coming away from the walls having lost its integrity. As the demolition work continued, the wall was increasingly saturated towards the bath taps where a persistent leak was identified in the breecher piece. This was causing water to drip inside the wall behind the tiles where it was able to get under the terrazzo floor. Work was ceased for repairs to be conducted by a plumber and a video of the damage to the wall and the dripping pipework was provided. After the pipes were repaired and the walls were given time to dry out, temporary repairs to only the shower recess were undertaken awaiting an assessment by the owner’s insurer. These repairs were conducted in accordance with Australian Standards, however the bathroom is not compliant due to the lack of waterproofing to the whole room as required of a second storey wet area. The structure was built prior to the requirement for waterproofing, so to complete the repair from the leaking pipe requires removal of all tiles and installation of a waterproof membrane. It is not in dispute that waterproofing was not required at the time the bathroom was constructed. The insurer says the damage to the bathroom is not covered The insurer says it has reviewed all reports provided by all parties and it is satisfied the proximate cause of damage to the downstairs ceiling is the deteriorated shower alcove flooring above and the lack of waterproofing. It says it is entitled to decline the claim because the policy does not respond to maintenance repairs. However, it agreed to cover the cost of the damage to the downstairs ceiling and cash settled this portion of the claim. The insurer notes that some damage may be attributed to the leaking pipes and has offered a further $5,000 cash settlement for that part of the damage. The complainant says the damage is covered The complainant says the leaking pipe could not be identified and repaired without his tiler, NS, removing tiles from the walls in the bathroom to locate the damage. The complainant has since had a plumber repair the pipes. To comply with Australian standards, the bathroom needs to be waterproofed. This cannot be done in sections, but needs to be a single membrane. The complainant has provided an itemised quote from his tiler for the works. The insurer is liable for the damage I have reviewed all of the information provided by both parties. I note the insurer argues the proximate cause of damage is the leaking shower base, based on PP’s report. I do not accept this. I consider the proximate cause of damage is the leaking pipes behind the shower and the bath. This is because LP, who initially inspected the bathroom, conducted a flood test of the shower and noted that it did not make any difference to the amount of water leaking below. Although PP conducted a flood test to the shower base and said that it failed, he did not provide any commentary about whether it made any difference to the leaking identified below. It is not in dispute there have been at least two leaking pipes behind the wall in the bathroom. The available information supports that these leaks have allowed water to continually run down the wall and underneath the bathroom floor causing damage. It is not in dispute the bathroom did not require waterproofing when it was constructed, but does require waterproofing now to be compliant. In my view, the insurer conducted a superficial inspection of the property. The complainant has had to continue to employ trades to attempt to ascertain the cause and the extent of the damage. This included removing tiles from the bathroom to access and repair the leaking pipes. Because of this, the bathroom needs to be waterproofed to be repaired. The insurer is liable for this because demolition works were required to locate and access the leaking pipe. This would be damage caused at least indirectly by the insured event. The complainant has provided a reasonable, itemised quote from his tiler to repair the damage. The quote is separated into works already conducted and for future works. The complainant should be cash settled for both quotes. This is because I do not accept that the shower base was the proximate cause of the damage. I note the complainant’s quote for future works includes a shower screen, which was not present before, and to respray the bath. I do not consider the insurer is liable for these items. These items should be removed and a 20% contingency should be applied to reflect the transfer of risk. This brings the total to $11,569.80. This amount is to be paid in addition to the $3,470 already paid by the complainant. Why is the outcome fair? The outcome is fair because the complainant is covered for escape of liquid events. It is not in dispute that there were two leaking pipes in the bathroom that caused the damage. The complainant had to remove wall tiles to access one of the leaking pipes to be repaired. The bathroom cannot be repaired without it now being waterproofed. On that basis, it is only fair that the insurer is liable for the costs to repair the damage, which included reinstating the bathroom. Supporting information 3.1 The AFCA process AFCA’s approach is based on fairness AFCA has determined this complaint based on what is fair in all the circumstances, having regard to: the legal principles applicable industry codes or guidance good industry practice previous decisions of AFCA or its predecessor schemes (which are not binding). The respective parties have completed a full exchange of the relevant information, and each party has had the opportunity to address any issues raised. We have reviewed and considered all of the information the parties have provided. While the parties have raised a number of issues in their submissions, we have restricted this determination to the issues that are relevant to the outcome. We assess complaints on available information and circumstances AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to require third parties to give evidence. When we assess complaints, we consider: available documents the recollections of the parties all relevant circumstances. We give more weight to documents created at the time the events occurred. If there are no relevant documents, we will decide what most likely occurred based on the available information. If there are conflicting recollections and these are evenly weighted, we may find that a claim cannot be established. Relevant terms of the policy Page 36: Policy Section 1 – Property damage About this Policy Section This Policy Section provides cover for loss of, or damage to, your property from Insured Events specified in this Policy Section, including but not limited to events such as fire, lightning and explosion. We do not cover the theft or breakdown of your property under this Policy Section. You can claim for loss of, or damage to, your property as described under ‘Insuring Clause – What we cover’ if: • ‘Property damage’ is shown as insured on your policy schedule; • the loss or damage occurs during the period of insurance; • the loss or damage is not excluded under ‘What we exclude’; and • the loss or damage is not excluded by any of the General Exclusions on pages 23 to 27. What we cover We cover loss or damage occurring during the period of insurance to buildings, contents, stock or specified items at the premises that is covered under an Insured Event clause 1 to 11 of this Policy Section. What we exclude This Policy Section (including the Extra Covers and Additional Benefits) does not cover: … 2. Maintenance or defects Loss or damage caused by or arising out of: rust or corrosion; inherent or structural defects; faulty design, materials or workmanship; or developing flaws, gradual deterioration, normal upkeep of property, or existing defects or lack of maintenance to property, unless you can show you did not know and could not reasonably have been expected to know about the flaw, deterioration, defect or lack of maintenance. You cannot claim for repairing the deterioration or defect or the maintenance. Page 38: Insured Events 6. Water damage What we cover We cover loss or damage caused directly or indirectly by: the discharge or leaking of water from any damaged pipe, water system (including a fire protection system such as a sprinkler system), tanks or drains installed in and servicing the building; or water from a damaged water main in the immediate vicinity of the building. We will also pay: up to a maximum of $25,000 in total for any one (1) period of insurance for all reasonable exploratory costs incurred in locating the source of the loss or damage, provided it is your responsibility to pay for these costs; the reasonable costs of removing water and any incidental cleaning operations; and if water is discharged from a fire protection system, any expenses incurred by you for the attendance of the fire brigade for the purpose of shutting off the water supply following an accidental discharge of water from a fire protection system. What we exclude We will not cover the cost of repair, replacement or rerouting of the defective part or parts of the pipe or water system that caused the loss of, or damage.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.