Home / Chubb / Determination 1017601
Determination 1017601
Denial of storm damage claim for retaining walls on basis of wear and tear, deterioration and poor construction exclusions
Summary
The insurer denied storm damage to two retaining walls, relying on wear and tear and construction exclusions. AFCA upheld the denial but required the insurer to honour its 10% repair cost offer and reimburse the $1,500 expert report.
Expert evidence showed the proximate cause was excluded long-term deterioration and erosion, but it was fair to honour the 10% offer and reimburse the reasonably obtained engineer report.
Issues
- Claim denial primary · not upheld“insurer has established it is more likely than not the proximate cause of the damage to the retaining walls are excluded factors”
- Inadequate claim investigation secondary · upheld“somewhat speculative language the insurer used in initially declining; it was reasonable for complainants to obtain CS's report”
Subjects and remedies
broker or intermediaryhome or building damagenatural disastersmall businesspay claimpay compensation
Related
Text of the determination
Determination
Case number 1017601
Financial firm Chubb Insurance Australia Limited
Determination | Case number: 1017601 Page 1 of 7
Case number: 1017601 3 April 2024
1 Determination overview
1.1 Complaint
The complainants hold industrial special risks insurance with the financial firm (insurer),
covering their commercial property. They lodged a claim for damage caused by significant
storm activity on 26 and 27 February 2022.
The insurer denied coverag e for damage to the property’s norther n and southern retaining
walls. It said the proximate cause of the damage was wear and tear, gradual deterioration
and poor construction. Damage from those causes is excluded under the policy terms.
The complainants maintain that the retaining walls collapsed due to the extraordinary volume
of rainfall that fell during the storm event. They want the insurer to reimburse them
$118,777.64, comprising $117,277.64 for repair costs and $1,500 for expert report costs.
1.2 Issues and key findings
Is the insurer entitled to deny the retaining walls damage?
Yes. Based on the exchanged information, the insurer has established it is more likely than
not the proximate cause of the damage to the retaining walls are excluded factors. However,
it is fair to require the insurer to honour its offer to reimburse 10% of the repair costs.
Is the insurer required to reimburse expert costs?
Yes. The insurer initially denied the claim based on an external loss adjuster’s report. Given
the complexity of the issues and as two retaining walls, constructed of different materials and
located far apart, were damaged it was reasonable for the complainants to obtain a report
from engineer CS. The insurer is to reimburse the compla inants the cost of CS’s report.
Why is the outcome fair?
The insurer has established the damage to the retaining walls was proximately caused by
excluded factors. It would be unfair to require the insurer to pay more than its offered 10%
contribution, when the policy does not respond. However, it is fair that the insurer reimburses
the cost of CS’s report as it was reasonable for the complainants to have obtained it.
1.3 Determination
This determination is substantially in favour of the insurer.
If the complainants provide it with written notice they accept this determination, the insurer is
required to pay within 14 days of receiving supporting invoices or other proof of payment:
10% of the proven cost of repairs to the retaining walls
$1,500, being the cost of CS’s report .
The insurer is not required to take any other action in relation to the matter the subject of this
determination.
Determination | Case number: 1017601 Page 2 of 7
2 Reasons for determination
The complainants are represented by their insurance broker, DT. The complainants and DT
are referred to as ‘the complainants’ in this determination, unless conte xt requires otherwise.
2.1 Is the insurer entitled to deny the retaining walls damage?
Yes. Based on the exchanged information, the insurer has established it is more likely than
not the proximate cause of the damage to the retaining walls are excluded factors. However,
it is fair to require the insurer to honour its offer to reimburse 10% of the repair costs.
Complainants have established a claimable loss under the policy terms
The complainants are required to show, on the balance of probabilities (that it is more likely
than not), that they suffered a claimable loss under the policy. This means they must show
the loss was caused by a risk for which they are insured.
Subject to the terms and conditions set out in the policy wording, the policy indemnifies the
complainant for physical loss, destruction or damage to the property insured.
On 27 April 2022, the complainants notified the insurer that on or about 26 to 27 February
2022, the property had sustained storm damage. The damage included the partial collaps e of
a paling fence and concrete crib retaining wall on the northern boundary (retaining wall one)
and of a section of a timber retaining wall on the southern boundary (retaining wall two).
It is not in dispute that the storm event occurred or that the retaining walls were damaged. In
the circumstances, I am satisfied that the complainants have established a claimable loss
under the policy.
Once the complainants prove the existence of a claimable loss, the insurer is liable for the
loss unless it shows an exclusion or limiting condition applies. The insurer has the onus of
proving on the balance of probabilities the application of the exclusion or condition.
Relevantly, the policy excludes cover for:
4) Physical loss, destruction or damage occasioned by or happening through:
…
(b) wear and tear, fading, scratching or marring, gradual deterioration or
developing flaws, normal upkeep or making good…
(c) error or omission in design, plan or specification or failure of design
…
(e) faulty materials or faulty workmanship
Proximate cause must be determined
In a general insurance claim, the term ‘proximate cause’ is used to describe whether an event
is the cause of the loss or damage. The proximate cause of a loss is the dominant, effective
or operative cause. It does not have to be the first, the last or the only cause.
If there are several causes, each should be examined to determine whether it is a dominant,
effective or operative cause of the loss. For example, if one cause would have caused the
loss on its own, and the other cause would not have caused the loss without the first, then the
first is the proximate cause.
Determination | Case number: 1017601 Page 3 of 7
If there are multiple proximate causes (equally contributing to the loss), and one of those
causes is excluded under the policy terms, an insurer is entitled under the Wayne Tank
principle to deny the entire claim.
Parties disagree on cause of the damage
The complainants rely on a report dated 21 September 2022 by engineer CS. After inspecting
the property on 23 August 2022, CS advised that:
both retaining walls were severely damaged
t he damage most likely happened due to ‘foundation and ground movements, as a result
of a sudden changing condition, which consequently caused the walls to collapse’
e ven though there were aging signs, the walls’ damage ‘most likely occurred due to
experiencing severe weather conditions and changing to the surrounding that caused
immediate failure to the structure…’
the damage to retaining wall one was most likely due to a major stormwater overflow from
an adjacent open stormwater trench at the side of the carpark above. This created
substantial water paths through the retained soil, and overloaded the wall’s capacity
the damage to retaining wall two was most likely and mainly due to stormwater streaming
from the roadside, and the stormwater remaining there, causing major damage to the
timber sleepers and overall structure
despite the overall deteriorated condition of the retaining walls, they would have survived
for a longer service life in normal weather conditions, however, the storm had significantly
reduced or ended the wall s’ functionality and their service life.
The insurer relies on a report dated 28 November 2022 by engineer IT. Following an
inspection of the property on 21 October 2022, IT reported that:
satellite images of retaining wall one showed:
> what appeared to be significant erosion of backfill materials in October 2021, at the
same point where the wall subsequently collapsed during the February 2022 storm
> the area between the wall and the boundary fences for the houses below was covered
with vegetation in November 2015, including a large tree at the area of later damage
the main cause of damage to retaining wall one was long term erosion of backfill materials
from behind the wall over time
the removal of the vegetation and large tree sometime between November 2015 and
October 2021 would have resulted in loss of root systems which would have previously
protected the retained soil from erosion by water flow
the carpark directs significant water volumes to the area of damage to retaining wall one.
The stormwater trench/kerb would have overspilled during heavy rainfall periods over time
while the heavy rains of January/February 2022 would have caused overspilling of the
kerb, leading to worsening of the damage, the damage was not the result of a single storm
retaining wall two had collapsed due to failure of the posts
the failed posts were significantly decayed where they were in contact with the ground
the decay and deterioration would have occurred over retaining wall two ’s 20 -year lifespan
the decay would have been accelerated by lack of adequate surface and subsoil drainage
the decay significantly compromised retaining wall two ’s structural capacity to resist
applied loads, leading to failure and progressive failure of the sleepers
the January/February 2022 rains were the ‘straw that broke the camel’s back’ as they
increased hydrostatic pressure, b ut the underlying reason for retaining wall two’s failure
was the decay and reaching the end of its serviceable life, making failure inevitable.
The complainants have provided brief statements from a neighbour whose home is below
retaining wall one, and from their major tenant. The neighbour and tenant both say that the
Determination | Case number: 1017601 Page 4 of 7
retaining walls were in good working condition prior to the storm event. The neighbour
unequivocally states retaining wall one was damaged by stormwater runoff in February 2022.
Due to the contradictory opinions of CS and IT, the insurer obtained a further engineering
opinion from SW. As the complainants had attended to repairs by the time SW was engaged,
its report was prepared on a desktop basis. In that report, dated 20 October 2023, SW:
included data from a Bureau of Meteorology weather station 6km from the property. That
data shows rainfall of 224mm on 26 February 2022, and 193mm the next day
retaining wall one’s failure was consistent with water overflowing the stormwater drain, and
eroding the backfill. The drain’s overflow was indicative of insufficient drainage provi sions
to service the carpark
satellite images showed the boundary fence above the relevant section of retaining wall
one was already deformed in November 2021 and January 2022. Accordingly, movement
due to stormwater overflow had already occurred before the subject storm event
the underlying cause of retaining wall one’s failure was long term erosion due to episodic
overflow from the stormwater drain. The subject storm was the trigger for the wall’s
collapse, but not its cause
noting other sections of retaining wall one were unaffected, if there had been no prior
backfill erosion, the section that did fail would not have done so
10% of retaining wall one’s failure was attributable to the storm
Photos in the reports of CS and IT confirmed the presence of rot to the collapsed
sleepers/posts of retaining wall two
the rot was the result of long term timber degradation over years
t he deterioration reduced retaining wall two’s structural capacity and integrity
built-up hydrostatic pressure during the storm in the absence of sufficient drainage
provisions triggered the collapse of the structurally compromised retaining wall two
if retaining wall two had been in a structurally adequate condition with adequate drainage
provisions, it would have been able to withstand hydrostatic pressure caused by the storm
t he underlying cause of retaining wall two’s failure was long term deterioration in
combination with lack of surface/subsoil drainage provisions
10% of retaining wall two’s failure was attributable to the storm.
The insurer says it is therefore entitled to deny the claim based on one or more of the
component parts of exclusion 4 set out on page two above. It says either the proximate cause
of the retaining walls’ damage was an excluded factor, or, if there were multiple proximate
causes (the storm and one or more excluded factors), the Wayne Tank principle applies.
Nevertheless, the insurer has offered to reimburse to the complainants 10% of the cost of
repairs to the retaining walls.
The complainants disagree with the insurer because:
there are two (2) retaining wall locations with different design and build materials
that were impacted by the storm activity...The retaining walls were deemed sound
and in good order prior to the storm event and this is further supported by the [CS]
report provided.
They say that they would be willing to resolve the dispute on the basis the insurer reimburses
them 75% of the repair costs they paid.
Determination | Case number: 1017601 Page 5 of 7
Insurer is entitled to deny the retaining wall damage
Based on the exchanged information, I am satisfied the insurer has established it is more
likely than not that the proximate cause of the damage to the retaining walls are excluded
factors. This is because:
the satellite images IT and SW have provided show there were clear signs of erosion and
damage in the section of retaining wall one that subsequently collapsed in the storm
photos contained in the reports of CS and IT show retaining wall two’s sleepers and posts
were affected by long term rot/deterioration
while the findings in the reports of CS and IT are contradictory, having reviewed both of
them, SW persuasively supports IT’s conclusions
the analysis and conclusions of IT and SW are supported by the fact that only sections of
the retaining walls collapsed in the storm. If the storm had been the proximate cause of the
damage, one would expect the damage to each wall to be more widespread
CS has acknowledged the retaining walls were already aged/deteriorated before the storm
I am satisfied that the engineers are better qualified to comment on causation than the
complainants’ neighbour and tenant, particularly because some of the factors involve d
were not readily observable.
However, noting the insurer has on several occasions offered to reimburse 10% of the proven
repair costs, it is fair and reasonable to require it to do so.
2.2 Is the insurer required to reimburse expert costs?
Yes. The insurer initially denied the claim based on an external loss adjuster’s report. Given
the complexity of the issues and as two retaining walls, constructed of different materials and
located far apart, were damaged it was reasonable for the complainants to obtain a report
from engineer CS. The insurer is to reimburse the complainants the cost of CS’s report.
AFCA may require insurer to contribute to a complainant’s pro fessional costs
The AFCA Rules enable AFCA to require an insurer to contribute to the professional costs
incurred by the complainant. These costs are, however, usually capped at a total of $5,000,
unless special circumstances apply.
When considering whether to require an insurer to make a costs contribution, AFCA
considers matters such as the complexity of the complaint and whether the particular
complainant needed to incur costs to understand or establish their claim.
Insurer is required to reimburse cos t of CS’s report
On 23 June 2022, the insurer advised the complainants it would be declining the damage to
the retaining walls ‘as the damage was unlikely to be related to the storm on the basis that all
the evidence indicated that the damage related to a gradual operating cause (possibly
contributed to by design and construction defects)’.
The insurer’s posi tion was based on its external loss adjusters ’ report dated 7 June 2022.
The complainants then engaged CS to provide a causation report. It was only after they
provided CS’s report to the insurer that it engaged IT.
Taking into account:
the somewhat speculative language the insurer used in initially declining to accept the
damage to the retaining walls
Determination | Case number: 1017601 Page 6 of 7
the fact that two retaining walls, constructed of different materials and located far apart,
had been damaged
the complexity of the causation factors potentially involved,
I am satisfied that it was reasonable for the complainants to obtain CS’s report to help them
understand their claim and in seeking to establish it.
Therefore, even though CS’s report did not ultimately assist them in establishing the claim, it
is reasonable to require the insurer to reimburse the complainants the $1,500 they paid for
the report (upon provision of proof of payment).
2.3 Why is the outcome fair?
The insurer has established the damage to the retaining walls was proximately caused by
excluded factors. It would be unfair to require the insurer to pay more than its offered 10%
contribution, when the policy does not respond. However, it is fair that the insurer reimburses
the cost of CS’s report as it was reasonable for the complainants to have obtained it.
Determination | Case number: 1017601 Page 7 of 7
3 Supporting information
3.1 The AFCA process
AFCA’s approach is based on fairness
AFCA has determined this complaint based on what is fair in all the circumstances, having
regard to:
the legal principles
applicable industry codes or guidance
good industry practice
previous decisions of AFCA or its predecessor schemes (which are not binding).
The respective parties have completed a full exchange of the relevant information, and each
party has had the opportunity to address any issues raised. I have reviewed and considered
all the information the parties have provided.
While the parties have raised several issues in their submissions, I have restricted this
determination to the issues that are relevant to the outcome.
We assess complaints on available information and circumstances
AFCA is not a court of law. We do not have the power to take or test evidence on oath, or to
require third parties to give evidence.
When we assess complaints, we consider:
available documents
the recollections of the parties
all relevant circumstances.
We give more weight to documents created at the time the events occurred. If there are no
relevant documents, we will decide what most likely occurred based on the available
information.
If there are conflicting recollections and these are evenly weighted, we may find that a claim
cannot be established.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.